VERSATILE LIMITSWITCHC O N T R O L S , I N C .


VERSATILE LIMITSWITCH<strong>DXLW</strong>-<strong>AF</strong> Weather Proof Limit Switch AS-I Protocol<strong>DXLW</strong>-<strong>AF</strong>D-Weather Proof Limit Switch-AS-I Protocol, <strong>Dribble</strong> <strong>control</strong>• Weather proof type “W” limit switch box has been designed toovercome lengthy wiring. It is easy to operate, maintain and<strong>control</strong>.• The limit switch box is configured to exchange data throughfield bus using AS-I protocol.• Field bus connectivity is achieved by using one or two cablesdepending on wiring system.• Solenoid termination inside enclosure is standard.COMMUNICATION CHARACTERISTICSProtocol : AS-I Interface using V2.1 profile 4140 simple addressingTransmission : AS-I cable flat type 2 wire, need 2 pair, or 5 wire cableBus Structure : Line or tree using repeatersMax # of Slaves : 31Input/output per Box : 2 Outputs / 2 InputsBus Cable Length : 100m, 300m with repeatersField Communication : Hand held infra-red <strong>control</strong>lerELECTRICAL CHARACTERISTICSSupply Voltage : 24 V DC +/- 10% with max 15% rippleBus Consumption :


VERSATILE LIMITSWITCHDNLF-<strong>AF</strong> Explosion Proof Limit Switch AS-I ProtocolDNLF-<strong>AF</strong>D-Explosion Proof Limit Switch-AS-I Protocol, <strong>Dribble</strong> <strong>control</strong>• Explosion proof type 'F' limit switch box has been designed toovercome lengthy wiring. It is easy to operate, maintain and <strong>control</strong>.• The limit switch box is configured to exchange data through field bususing AS-I protocol.• Field bus connectivity is achieved by using one or two cablesdepending on wiring system.• Solenoid termination inside enclosure is standard.COMMUNICATION CHARACTERISTICSProtocol: AS-I Interface using V2.1 profile 4140 simple addressingTransmission: AS-I cable flat type 2 wire, need 2 pair, or 5 wire cableBus Structure: Line or tree using repeatersMax # of Slaves : 31Input/output per Box : 2 Outputs / 2 InputsBus Cable Length : 100m, 300m with repeatersField Communication : Hand held infra-red <strong>control</strong>lerELECTRICAL CHARACTERISTICSSupply Voltage: 24 V DC +/- 10% with max 15% rippleBus Consumption:


21 Sullivan Parkway,Fort Edward, NY 12828LI SW - 01 - 13 - M1 DESIGN : Media Inc. Ph. +91-265-2422835INFINITY ACTUATORSTel : (888) 813 - 9772Fax : (866) 478 - 9620www.rotex<strong>control</strong>s.com