11.07.2015 Views

EXFO/FTB-5700-angHR MHz 12-07.pdf - Mega Hertz

EXFO/FTB-5700-angHR MHz 12-07.pdf - Mega Hertz

EXFO/FTB-5700-angHR MHz 12-07.pdf - Mega Hertz

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SINGLE-ENDED DISPERSION ANALYZER<strong>FTB</strong>-<strong>5700</strong>NETWORK TESTING—OPTICALThe ultimate CD/PMD characterization solutionSingle-ended PMD and CD measurementsThe advantage of one: complete dispersion analysis witha single module, a single connector and a one-step test setupUnparalleled software user-friendliness: all automatedTesting range: up to <strong>12</strong>0 kmPlatform Compatibility<strong>FTB</strong>-400 Universal Test System<strong>FTB</strong>-200 Compact PlatformTelecom Test and Measurement


<strong>FTB</strong>-<strong>5700</strong>Single-Ended Dispersion AnalyzerThe Only Combined CD and PMD Test Moduleon the MarketBuilding on <strong>EXFO</strong>’s market-proven dispersion testing expertise, the <strong>FTB</strong>-<strong>5700</strong> Single-Ended Dispersion Analyzer combines chromaticdispersion and polarization mode dispersion measurement into a single, highly automated, high-efficiency test solution. It offersthe true advantage of one—one-ended testing using one module, one connector and a one-step test setup and delivering onecombined results file—dramatically reducing the cost of ownership and speeding up the learning curve, the test cycles as well asthe reporting.Housed in either of <strong>EXFO</strong>’s multimodular portable platforms, the <strong>FTB</strong>-200 Compact Platform and the <strong>FTB</strong>-400 Universal Test System, the<strong>FTB</strong>-<strong>5700</strong> delivers straightforward, yet advanced CD and PMD characterization in a single affordable instrument optimized for both entryleveland seasoned technicians.CD and PMD TestingCombo─The BenefitsOne, lightweight unit that:Provides exclusive single-ended testingtechnologyEnables one technician to test both CDand PMDRequires only one training sessionMinimizes manual interventions, for failsaferesultsReduces required connections to just oneSaves valuable processing time─oneGUI, one results file, one report* High reflection (4% or more) required at far end, using an unterminated UPC connector or reflector connector.


<strong>FTB</strong>-<strong>5700</strong>Single-Ended Dispersion AnalyzerCharacterize CD in a SnapThe ongoing race to develop high-speed transmissionsystems and to increase available bandwidth isfacing certain limitations. Chromatic dispersion (CD)measurements are becoming more and more critical forcarriers and service providers looking to upgrade theirsystems to faster transmission rates, such as 10 Gbit/s(OC-192/STM-64), and longer routes, thanks to theadvent of reconfigurable optical add/drop multiplexers(ROADMs).What’s more, since the eight test points areconfigurable, the <strong>FTB</strong>-<strong>5700</strong> never “loses” test pointsdue to high attenuation. Whatever the link, testparameters are automatically optimized.The <strong>FTB</strong>-<strong>5700</strong> features a highly intuitive user interface presenting straightforward pass/fail results.ITU Common Name Default Test Wavelengths Range*G.652 Standard Fiber 1475 - 1626 nmG.653G.654G.655G.656Dispersion-Shifted Fiber (DSF)Cut-off Shifted FiberNon-Zero Dispersion-Shifted Fiber (NZDSF)Wideband Non-Zero Dispersion Fiber1475 - 1626 nm1530 - 1626 nm1475 - 1626 nm1475 - 1626 nm* Being configurable, the <strong>FTB</strong>-<strong>5700</strong> automatically selects the proper test wavelength accordingto fiber type.Key CD Testing FeaturesGroundbreaking single-ended testing technologyLink-length measurementNetwork recognition: automatically adopts the proper parameter setupsComplies with ITU G.65X fiber testing standards


<strong>FTB</strong>-<strong>5700</strong>Single-Ended Dispersion AnalyzerThe Only Single-Ended PMD Analyzeron the MarketPMD is a real threat to both legacy and newly deployed networks. And as high-speed services—namely 10 Gbit/s—are being massivelydeployed, PMD awareness continues to grow. Whether you need to assess the PMD level of legacy fiber or perform networkmaintenance, <strong>EXFO</strong>’s <strong>FTB</strong>-<strong>5700</strong> PMD Analyzer <strong>FTB</strong>-<strong>5700</strong> is fast, reliable and ready to go.Key PMD Testing FeaturesThe only single-ended PMD analyzer on the market: reduced both the testing time and operational expenses (OPEX)Random SOP scrambling: robust technology for aerial fibersBased on TIA FOTP-<strong>12</strong>4A and IEC 6<strong>12</strong>82-9PMD is an average of delay values over a given wavelength range and state of polarization. The <strong>FTB</strong>-<strong>5700</strong> being tunable, over 200wavelength pairs are acquired, all at different states of polarization. Each pair provides a delay point.For even higher accuracy, you can launch multiple scans and perform an averaging of all test results.ApplicationUltra-Long HaulLong-HaulMetro2.5 GbitAcceptance10 GbitAcceptance40 GbitAcceptanceAccuracy<strong>FTB</strong>-<strong>5700</strong><strong>FTB</strong>-5500/<strong>FTB</strong>-5800


<strong>FTB</strong>-<strong>5700</strong>Single-Ended Dispersion AnalyzerA Highly Intuitive User Interfacewith No Setup RequiredFeaturing easy-to-read pass/fail results and providing a view of all key parameters and values on one screen, the <strong>FTB</strong>-<strong>5700</strong>’s userinterface is all about field testing simplicity and efficiency.Key pass/fail measurementsSingle press:start all testsSave or discardSelect testto performFiber Auto-namingCritical info on selected testCritical info on selected test


<strong>FTB</strong>-<strong>5700</strong>Single-Ended Dispersion AnalyzerFast-Track Data Post-Processingwith FastReporter SoftwareThe optional FastReporter software packageprovides you with the postprocessing tools andfunctionalities you need to optimize your testcycles, whatever the application. Designed foroff-line analysis of field-acquired data,FastReporter offers a truly intuitive graphical userinterface, which contributes to boostingproductivity.Flexible ReportingChoose from various report templates, includingPMD, CD and fiber characterization. Generatecomprehensive cable reports in PDF, Excel orHTML format.<strong>EXFO</strong>’s Dispersion AnalyzerSeries: Applications ChartFor extreme accuracy and ultra-long-haul networkapplications, <strong>EXFO</strong> also offers the <strong>FTB</strong>-5800 CDAnalyzer and <strong>FTB</strong>-5500B PMD Analyzer. Thischart shows the list of applications for each of<strong>EXFO</strong>’s dispersion analyzer series.10 Gbit/sShort reachLong reachUltra-long reachAmplified linkCompensationShort reachLong reachUltra-long reachAmplified linkCompensation<strong>FTB</strong>-<strong>5700</strong> Single-EndedDispersion Analyzer<strong>FTB</strong>-5500B PMD Analyzer<strong>FTB</strong>-5800 CD Analyzer40 Gbit/s


<strong>FTB</strong>-<strong>5700</strong>Single-Ended Dispersion AnalyzerSPECIFICATIONS (PRELIMINARY) aMeasured wavelength range (nm) 1475 to 1626Maximum measurement distance (km)≥<strong>12</strong>0Distance uncertainty (km)± (0.01 + 1 % x distance)Chromatic dispersion bNumber of test points 8CD uncertainty (ps/nm) ± <strong>12</strong>Test time (s) 40PMD cPMD range (ps) 0.5 to 15Test time (s) 180GENERAL SPECIFICATIONSTemperatureOperating 0 °C to 50 °C (32 °F to <strong>12</strong>2 °F)Storage —40 °C to 70 °C (—40 °F to 158 °F)Relative humidity0 % to 93 % non-condensingSize (H x W x D) 96 mm x 50 mm x 281 mm (3 3 /4 in x 2 in x 11 in)Weight 1.3 kg (2.8 lb)Notesa. Typical.b. At 1550 nm, on 50 km of G.652 singlemode fiber.c. For a fiber length ≥ 100 m.ORDERING INFORMATION<strong>FTB</strong>-<strong>5700</strong>-XX-XXModel<strong>FTB</strong>-<strong>5700</strong>-CD-PMD = Single-ended CD and PMD analyzer<strong>FTB</strong>-<strong>5700</strong>-PMD = Single-ended PMD analyzer<strong>FTB</strong>-<strong>5700</strong>-CD = Single-ended CD analyzerExample: <strong>FTB</strong>-<strong>5700</strong>-CD-PMD-EI-EUI-89ConnectorEI-EUI-28 = UPC/DIN 47256EI-EUI-76 = UPC/HMS-10/AGEI-EUI-89 = UPC/FC narrow keyEI-EUI-90 = UPC/STEI-EUI-91 = UPC/SCEI-EUI-95 = UPC/E-2000EA-EUI-28 = APC/DIN 47256EA-EUI-89 = APC/FC narrow keyEA-EUI-91 = APC/SCEA-EUI-95 = APC/E-2000For extreme accuracy and ultra-long-haul network applications, <strong>EXFO</strong> also offers the <strong>FTB</strong>-5800 CD Analyzer and <strong>FTB</strong>-5500B PMD Analyzer.For these modules, the above connector choice applies, but the FLS-5834A light source is required.D istributed by: <strong>Mega</strong> <strong>Hertz</strong>8 00-883-8839 sales@go2mhz.com www.go2mhz.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!