Panelboards<strong>Type</strong> <strong>P5</strong> PanelboardsFeaturesThe <strong>P5</strong> panel is the largest footprintdistribution panel in the <strong>Siemens</strong> panelfamily. Even though it is our largestpanel type, the <strong>P5</strong> panel is still a spacesaver with it’s 38" width and 12.75"depth. With even higher main ratingsto fit the application that require more orlarger branch devices. This panel offers awide array of factory assembled optionsand has the ability to mix breaker framesin unit space up to 1200 amps andfusible switches up to 1200 amps.Bussing options for the <strong>P5</strong> vary from thestandard temperature rated aluminum totemperature rated copper and 750 A/SIaluminum and 1000A/Si copper designs.All aluminum bussing in the <strong>P5</strong> panel istin-plated as a standard. Silver-plated isoffered as the default for copper bus andtin as an option. Integrated time clocks,bus mounted contactors as mains orsubmains, split bus and subfeed lugs(up to 600 amps) are just a few of theoptions of this flexible panel.The <strong>P5</strong> panel configurations defined bythe unit space allowed for a givenamperage, main device and box height.The <strong>P5</strong> panel starts with a 60" high box.All of the branch devices are unit spacemounted. Breakers and switches can bemixed and matched to meet customerrequirements.Main Lug / Main Breaker / MainSwitchEnclosure – Standard <strong>Type</strong> 1 enclosureis 38" wide x 12.75" deep. X Box Heightis determined by main device and unitspace. See charts for box height.Voltage – 600V AC max.250V DC max.Amperage – 800-1200 amp Mainbreaker, 800-1200 amp MLO (checkavailability of 1600 amp with factory),400-1200 amp Main switch.Short Circuit Rating – 200 Kaic max.symmetrical or equal to the lowest rateddevice installed unless a series rating isindicated. Panels with subfeed orfeed-thru lugs without a main device,circuit breaker or fusible unit, are limitedto a three-cycle rating. The three-cyclerating for the <strong>P5</strong> panel is limited to 42Kaic. Note that the main device may bemounted remote from the panel.Bussing – The <strong>P5</strong> panel has moreoptions to meet market requirements.The standard bussing is temperaturerated aluminum. The rating is per therequirements of UL 67 – the standard forpanelboards. All aluminum bussing istin-plated. Optional bussing for the <strong>P5</strong>panel is: 750 A/si aluminum, temperaturerated copper, and 1000 A/si copper.The copper bus option for this panel istin-plated.Weight – ApproximateTotal panelboard weight when filledwith a normal quantity of breakers andaccessories is about 10 lbs. (1 kg) perinch (54g per mm) of box height.Main Lugs AmpereConnectors Suitable forRatingCopper or Aluminum800 (3) - #3/0 AWG-500 Kcmil1000 (4) - #3/0 AWG-500 Kcmil1200 (4) - #3/0 AWB-500 Kcmil Alternate lugs for 750 kcmil cable are available, butresult in significant loss of branch unit mounting space.Consult <strong>Siemens</strong>.Gauge Steel of Boxes Fronts, Surfaceand FlushDimensions ininches (mm) Gauge SteelWidth Height Box Fronts38" 60 - 75 - 90 #16 #14 (1 piece trim)(965) (1524, 1905, #14 Ga. (4 piece2286) trim) 16 gauge side panels, 12 gauge back support.General10 PANELBOARDS<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 10-55


PanelboardsPower and DistributionEnclosure Selection Selection/DimensionsEnclosure Dimension in Inches (mm)Available Unit Space in Inches (mm)H W D Main Lug Main Breaker Main Switch<strong>Type</strong> 1, 3R/12 <strong>Type</strong> 1, 3R/12 <strong>Type</strong> 1 <strong>Type</strong> 3R/12 800 / 1200A 800 / 1200A 800 / 1200A60 (1524) 38 (965) 12.75 (324) 14.25 (362) 30 (762) 20 (508) —75 (1905) 38 (965) 12.75 (324) 14.25 (362) 45 (1143) 35 (889) 35 (889)90 (2286) 38 (965) 12.75 (324) 14.25 (362) 60 (1524) 50 (1270) 50 (1270)Main Breaker Unit Space DimensionsDimensions in Inches (mm)AmpereNeutralRating Breaker <strong>Type</strong> A BLXD6, LMXD6, LMD6, MXD6, MD6, HMD6 13.00 (330)800CMD6, SCMD6, SHMD6, SMD6 10.42 (265) 13.125 (333)1200 NXD6, ND6, HND6, CND6, SND6, SHND6 13.00 (330)Main SwitchMaximumAmpere Rating A B400A/600A VB 9.3 13.125800A/1200A HCP 10.3 13.125Main Switch ConnectorsAmpere Connectors suitable forRating Copper or Aluminum400(1) #3/0 AWG-500 kcmil(2) #3/0 AWG-250 kcmil600 (2) #3/0 AWG-500 kcmil800 (3) #3/0 AWG-500 kcmil1200 (4) #3/0 AWG-500 kcmilMain Lugs Only Wire Bending SpaceDimensions in inches (mm)Main LugNeutral800A 1000A 1200A 800ALugs C D E GMain Breaker Wire Bending SpaceDimensions & Main SwitchStandard 15.969 (406) 15.969 (406) 15.969 (406) 13.125 (333)Oversize 25.969 (660) 25.969 (660) 25.969 (660) 23.125 (587)Crimp 18.687 (475) 18.250 (464) 18.250 (464) 15.937 (405)Standard withSubfeed— — — 13.125 (333)Standard withFeed-thru— — — 13.125 (333)Main Lugs Only Wire Bending SpacePANELBOARDS10 Standard trim is for space without door. Surface flushone piece trim is available for 32" (813mm) wide circuitbreaker panel.10-56<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog


PanelboardsPower and Distribution<strong>Type</strong> <strong>P5</strong>Shown with Standard Mains, Top Fedand Surface TrimCatalog number is for aluminum mainbus. For optional copper main buschange “A” in position 11 to “C”.Panels are top feed, surface mounted.For bottom feed, change “T” in position12 to “B”. For flush mounting,change “S” in position 13 to “F”.SelectionReplace fifth and sixth positionin panelboard catalog number,with alternate main breaker code.Use price adders from main breakersection table. Horizontally mounted.Main Lugs Only — shown with aluminum bus, top fed, and surface trims.MaximumUnit208Y/120V 240/120V 120/240V or 250 Vdc MaxPanel Space 3-Phase, 4-Wire List 3-Phase, 4-Wire List 1-Phase, 3-Wire ListAmpere Rating (inches) Catalog Number Price $ Catalog Number Price $ Catalog Number Price $30 <strong>P5</strong>C60ML800ATS 2020.00 <strong>P5</strong>B60ML800ATS 2020.00 <strong>P5</strong>A60ML800ATS 2020.00800 45 <strong>P5</strong>C75ML800ATS 2130.00 <strong>P5</strong>B75ML800ATS 2130.00 <strong>P5</strong>A75ML800ATS 2130.0060 <strong>P5</strong>C90ML800ATS 2260.00 <strong>P5</strong>B90ML800ATS 2260.00 <strong>P5</strong>A90ML800ATS 2260.0030 <strong>P5</strong>C60ML101ATS 2460.00 <strong>P5</strong>B60ML101ATS 2460.00 <strong>P5</strong>A60ML101ATS 2460.001000 45 <strong>P5</strong>C75ML101ATS 2610.00 <strong>P5</strong>B75ML101ATS 2610.00 <strong>P5</strong>A75ML101ATS 2610.0060 <strong>P5</strong>C90ML101ATS 2750.00 <strong>P5</strong>B90ML101ATS 2750.00 <strong>P5</strong>A90ML101ATS 2750.0030 <strong>P5</strong>C60ML120ATS 2900.00 <strong>P5</strong>B60ML120ATS 2900.00 <strong>P5</strong>A60ML120ATS 2900.001200 45 <strong>P5</strong>C75ML120ATS 3070.00 <strong>P5</strong>B75ML120ATS 3070.00 <strong>P5</strong>A75ML120ATS 3070.0060 <strong>P5</strong>C90ML120ATS 3230.00 <strong>P5</strong>B90ML120ATS 3230.00 <strong>P5</strong>A90ML120ATS 3230.00MaximumUnit240 480Y/277V 480V Panel Space 3-Phase, 3-Wire List 3-Phase, 4-Wire List 1-Phase, 3-Wire ListAmpere Rating (inches) Catalog Number Price $ Catalog Number Price $ Catalog Number Price $30 <strong>P5</strong>D60ML800ATS 1610.00 <strong>P5</strong>E60ML800ATS 2020.00 <strong>P5</strong>F60ML800ATS 1610.00800 45 <strong>P5</strong>D75ML800ATS 1720.00 <strong>P5</strong>E75ML800ATS 2130.00 <strong>P5</strong>F75ML800ATS 1720.0060 <strong>P5</strong>D90ML800ATS 1800.00 <strong>P5</strong>E90ML800ATS 2260.00 <strong>P5</strong>F90ML800ATS 1800.0030 <strong>P5</strong>D60ML101ATS 1960.00 <strong>P5</strong>E60ML101ATS 2460.00 <strong>P5</strong>F60ML101ATS 1960.001000 45 <strong>P5</strong>D75ML101ATS 2070.00 <strong>P5</strong>E75ML101ATS 2610.00 <strong>P5</strong>F75ML101ATS 2070.0060 <strong>P5</strong>D90ML101ATS 2150.00 <strong>P5</strong>E90ML101ATS 2750.00 <strong>P5</strong>F90ML101ATS 2150.0030 <strong>P5</strong>D60ML120ATS 2300.00 <strong>P5</strong>E60ML120ATS 2900.00 <strong>P5</strong>F60ML120ATS 2300.001200 45 <strong>P5</strong>D75ML120ATS 2430.00 <strong>P5</strong>E75ML120ATS 3070.00 <strong>P5</strong>F75ML120ATS 2430.0060 <strong>P5</strong>D90ML120ATS 2550.00 <strong>P5</strong>E90ML120ATS 3230.00 <strong>P5</strong>F90ML120ATS 2550.00Main Circuit Breaker — shown with aluminum bus, top fed, and surface trims.MaximumUnit208Y/120V 240/120V 120/240V or 250 Vdc MaxPanel Space 3-Phase, 4-Wire List 3-Phase, 4-Wire List 1-Phase, 3-Wire ListAmpere Rating (inches) Catalog Number Price $ Catalog Number Price $ Catalog Number Price $21.25 <strong>P5</strong>C60M1800ATS 8140.00 <strong>P5</strong>B60M1800ATS 8140.00 <strong>P5</strong>A60M1800ATS 6820.00800 36.25 <strong>P5</strong>C75M1800ATS 8590.00 <strong>P5</strong>B75M1800ATS 8590.00 <strong>P5</strong>A75M1800ATS 7190.0051.25 <strong>P5</strong>C90M1800ATS 9040.00 <strong>P5</strong>B90M1800ATS 9040.00 <strong>P5</strong>A90M1800ATS 7570.0020 <strong>P5</strong>C60N1120ATS 12900.00 <strong>P5</strong>B60N1120ATS 12900.00 <strong>P5</strong>A60N1120ATS 11590.001200 35 <strong>P5</strong>C75N1120ATS 13620.00 <strong>P5</strong>B75N1120ATS 13620.00 <strong>P5</strong>A75N1120ATS 12230.0050 <strong>P5</strong>C90N1120ATS 14350.00 <strong>P5</strong>B90N1120ATS 14350.00 <strong>P5</strong>A90N1120ATS 12880.00MaximumUnit240 480Y/277V 480V Panel Space 3-Phase, 4-Wire List 3-Phase, 4-Wire List 1-Phase, 3-Wire ListAmpere Rating (inches) Catalog Number Price $ Catalog Number Price $ Catalog Number Price $21.25 <strong>P5</strong>D60M1800ATS 7720.00 <strong>P5</strong>E60M1800ATS 8140.00 <strong>P5</strong>F60M1800ATS 7720.00800 36.25 <strong>P5</strong>D75M1800ATS 8160.00 <strong>P5</strong>E75M1800ATS 8590.00 <strong>P5</strong>F75M1800ATS 8160.0051.25 <strong>P5</strong>D90M1800ATS 8590.00 <strong>P5</strong>E90M1800ATS 9040.00 <strong>P5</strong>F90M1800ATS 8590.0020 <strong>P5</strong>D60N1120ATS 12310.00 <strong>P5</strong>E60N1120ATS 12900.00 <strong>P5</strong>F60N1120ATS 12310.001200 35 <strong>P5</strong>D75N1120ATS 13010.00 <strong>P5</strong>E75N1120ATS 13620.00 <strong>P5</strong>F75N1120ATS 13010.0050 <strong>P5</strong>D90N1120ATS 13680.00 <strong>P5</strong>E90N1120ATS 14350.00 <strong>P5</strong>F90N1120ATS 13680.00For inches / millimeters conversion, see Application Datasection. For 600V, change “F” in position 3 to “G”. Price onlybranch breakers with 600V ratings. Alternate main breaker requires additional 1.25" unitspace.10 PANELBOARDSDiscount Schedule PBSB <strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 10-57


PanelboardsPower and DistributionAlternate Main Breaker Selection SelectionMain Fusible Switch (fuses not included)MaximumUnit208Y/120V 240/120V 120/240VPanel Space 3-Phase, 4-Wire List 3-Phase, 4-Wire List 1-Phase, 3-Wire ListAmpere Rating (inches) Catalog Number Price $ Catalog Number Price $ Catalog Number Price $4002040<strong>P5</strong>C75MS400ATS<strong>P5</strong>C90MS400ATS3480.003660.00<strong>P5</strong>B75MS400ATS<strong>P5</strong>B90MS400ATS3480.003660.00<strong>P5</strong>A75MS400ATS<strong>P5</strong>A90MS400ATS2790.002940.006002540<strong>P5</strong>C75MS600ATS<strong>P5</strong>C90MS600ATS4920.005170.00<strong>P5</strong>B75MS600ATS<strong>P5</strong>B90MS600ATS4920.005170.00<strong>P5</strong>A75MS600ATS<strong>P5</strong>A90MS600ATS4170.004380.00800 28.7543.75<strong>P5</strong>C75MS800ATS<strong>P5</strong>C90MS800ATS7640.008030.00<strong>P5</strong>B75MS800ATS<strong>P5</strong>B90MS800ATS7640.008030.00<strong>P5</strong>A75MS800ATS<strong>P5</strong>A90MS800ATS6290.006610.001200 28.7543.75<strong>P5</strong>C75MS120ATS<strong>P5</strong>C90MS120ATS9770.0010290.00<strong>P5</strong>B75MS120ATS<strong>P5</strong>B90MS120ATS9770.0010290.00<strong>P5</strong>A75MS120ATS<strong>P5</strong>A90MS120ATS8070.008500.00MaximumUnit240V 480Y/277V 480V Panel Space 3-Phase, 3-Wire List 3-Phase, 4-Wire List 3-Phase, 3-Wire ListAmpere Rating (inches) Catalog Number Price $ Catalog Number Price $ Catalog Number Price $4002540<strong>P5</strong>D75MS400ATS<strong>P5</strong>D90MS400ATS3480.003660.00<strong>P5</strong>E75MS400ATS<strong>P5</strong>E90MS400ATS4650.004900.00<strong>P5</strong>F75MS400ATS<strong>P5</strong>F90MS400ATS3890.004100.006002540<strong>P5</strong>D75MS600ATS<strong>P5</strong>D90MS600ATS4920.005170.00<strong>P5</strong>E75MS600ATS<strong>P5</strong>E90MS600ATS5190.005480.00<strong>P5</strong>F75MS600ATS<strong>P5</strong>F90MS600ATS4920.005180.00800 28.7543.75<strong>P5</strong>D75MS800ATS<strong>P5</strong>D90MS800ATS7640.008030.00<strong>P5</strong>E75MS800ATS<strong>P5</strong>E90MS800ATS7650.008050.00<strong>P5</strong>F75MS800ATS<strong>P5</strong>F90MS800ATS7250.007620.001200 28.7543.75<strong>P5</strong>D75MS120ATS<strong>P5</strong>D90MS120ATS9770.0010290.00<strong>P5</strong>E75MS120ATS<strong>P5</strong>E90MS120ATS9770.0010290.00<strong>P5</strong>F75MS120ATS<strong>P5</strong>F90MS120ATS9240.009730.00Maximum IR (KA)Ampere Breaker CatalogSymmetrical AmperesListRating <strong>Type</strong> Number 240V AC 480V AC 600V AC Price $ Available Trip ValuesNMX M1 65 35 25 STD 600, 700, 800800 HMX M2 100 65 50 1130. 600, 700, 800LMX M3 200 100 65 3260. 600, 700, 800LMD6 LMXD6 65 50 25 590. 500, 600, 700, 800HLMD6 HD 100 65 50 1870. 500, 600, 700, 800MD6 M6 65 50 25 1710. 500, 600, 700, 800800HMD6 HM 100 65 50 2370. 500, 600, 700, 800CMD6 CM 200 100 50 4370. 500, 600, 700, 800SMD6 SM 65 50 25 5860. 600, 700, 800SHMD6 S8 100 65 50 3540. 600, 700, 800SCMD6 C8 200 100 65 5860. 500, 600, 800NNX N1 65 35 25 STD 800, 900, 1000, 12001200 HNX N2 100 65 50 1130. 800, 900, 1000, 1200LNX N3 200 100 65 2500. 800, 900, 1000, 1200ND6 N6 65 50 25 1190. 800, 900, 1000, 1200HND6 HN 100 65 50 2370. 800, 900, 1000, 12001200CND6 CN 200 100 50 2500. 900, 1000, 1200SND6 SN 65 50 25 2440. 900, 1000, 1200SHND6 SI 100 65 50 4080. 800, 900, 1000, 1200SCND6 CI 200 100 65 5080. 800, 900, 1000, 1200PANELBOARDS10For inches / millimeters conversion, see ApplicationData section. For 600V, change “F” in position 3 to “G”. Price onlybranch breakers with 600V ratings. For ground fault, see page 10-62. Replace “MB” in catalog number with code letter.Use adders from this table. 800 and 1200 ampere switches have “L” class fuseprovisions (<strong>Type</strong> HCP).10-58<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule PBSB


PanelboardsPower and Distribution<strong>Type</strong> <strong>P5</strong>Branch Circuit Breakers Space price covers cost of housing frame plate withblank cover plate. Provision price includes all necessarymounting hardware, less circuit breaker, and includeshousing frame cover plate with breaker handle opening. 1 to 6 poles may be mounted in 3.75" of unit space. Accessories such as shunt trips on three pole breakersrequire 6.25" of unit space. HED4 1-pole 15–30A = 65,000 IR35–100A = 25,000 IRSelectionAvailableProvisionsMounting Height Maximum Interrupting RatingBreaker Trip ValueList Price Installed $Space for(inches)(KA)<strong>Type</strong> Ampere Ratings 1-Pole 2-Pole 3-Pole $ Future $ Twin Single 120V 120/240V 240V 277V 480Y/277 480V 600V 250V DCBL15, 20, 30, 40, 50, 60 100. 170. 250. 35. 55. — — 10 — — — — — —70 160. 190. 290. 35. 55. 3.75 — — 10 — — — — — —80, 90, 100 — 230. 330. 35. 55. — — 10 — — — — — —BL (HID) 15, 20, 30 110. 190. — 35. 55. 3.75 — — 10 — — — — — —BAF (arc fault) 15, 20 220. 380. — 35. 55. 3.75 — 10 10 — — — — — —BAFH(arc fault) 15, 20 280. 450. — 35. 55. 3.75 — 22 22 — — — — — —BLF (GFCI)15, 20, 3040, 50, 60220.—250.290.——35.35.55.55. 3.75 ————1010————————————BLE (EQ GFI) 15, 20, 30 200. 250. — 35. 55. 3.75 — — 10 — — — — — —BLEH15, 20, 3040, 50, 60420.—530.530.——35.35.55.55.3.75 3.75 ————1010————————————BGL (SWN) 15, 20, 30 — 180. 230. 35. 55. 3.75 — — 10 — — — — — —BL (240V)R15, 20, 30, 40, 50, 60, 7070, 80, 90, 100——210.310.——35.35.55.55. 3.75 ——————1010——————————BLH (120V)15, 20, 30, 40, 50, 60 130. 240. 340. 35. 55. 3.75 — — 22 — — — — — —70 — 340. 380. 35. 55. 3.75 — — 22 — — — — — —80, 90, 100 225. 280. 480. 35. 55. — — 22 — — — — — —BLHF (GFCI)15, 20, 3040, 50, 60250.—340.———35.35.55.55. 3.75 ————2222————————————HBL15, 20, 30, 40, 50, 6070, 80, 90, 100130.—320.420.400.540.35.35.5555. 3.75 ————2222————————————BQD15, 20, 30, 40, 50, 6070, 80, 90, 100130.200.320.420.400.540.35.35.55.55. 3.75 ——————6565——1414————1414NGB15—60 140. 460. 510. 35. 50. 100 100 100 25 25 25 — 1470—100 210. 500. 660. 35. 50. 3.75 — 100 100 100 25 25 25 — 14110—125 — 820. 1190. 35. 50. 100 100 100 25 25 25 — 14NEB15—60 270. 450. 590. 35. 50. 85 85 85 35 35 35 — 3570—100 300. 510. 670. 35. 50. 3.75 — 85 85 85 35 35 35 — 35110—125 730.= 1290. 1440. 35. 50. 85 85 85 35 35 35 — 35HEB15—60 390. 690. 910. 35. 50. 100 100 100 65 65 65 — 4270—100 430. 760. 990. 35. 50. 3.75 — 100 100 100 65 65 65 — 42110—125 1220.= 2150. 2280. 35. 50. 100 100 100 65 65 65 — 42ED4 15, 20, 30, 40, 50, 60 175. 570. 630. 75. 110. — — — 65 — 18 18 — 3070, 80, 90, 100 260. 620. 820. 75. 110. 3.75 — — — 65 — 18 18 — 30110, 125 — 1010. 1470. 75. 110. — — — 65 — 18 18 — 30HED4 15, 20, 30, 40, 50, 60 490. 850. 1120. 75. 110. — — — 100 25 42 — 3070, 80, 90, 100 490. 950. 1220. 75. 110. 3.75 — — — 100 — 25 42 — 30110, 125 — 2660. 2830. 75. 110. — — — 100 — 42 42 — 30HHED615, 20, 30, 40, 50, 60 — 940. 1250. 75. 110. — — — 100 — — 65 25 —70, 80, 90, 100 — 1060. 1360. 75. 110. 3.75 — — — 100 — — 65 25 —110, 125 — 2970. 3130. 75. 110. — — — 100 — — 65 25 —CED615, 20, 30, 40, 50, 60, 70, 80, 90, 100110, 125——1970.3160.2410.3980.75.75.110.110.3.75 ———————200—————200———30—QJ2 60, 70, 80, 90, 100, 125, 150, 175, 200, 225 — 720. 940. 75. 150. 5 5 — — 10 — — — — —QJH2 60, 70, 80, 90, 100, 125, 150, 175, 200, 225 — 740. 1250. 75. 150. 5 5 — — 22 — — — — —QJ2H 60, 70, 80, 90, 100, 125, 150, 175, 200, 225 — 1030. 1540. 75. 150. 5 5 — — 42 — — — — —FXD6 70, 80, 90, 100, 125, 150, 175, 200, 225 — 1250. 1590. 75. 320. 5 5 — — 65 — — 35 — 30HFD6 70, 80, 90, 100, 125, 150, 175, 200, 225 — 2750. 3350. 75. 320. 5 5 — — 100 — — 65 — 30CFD6 70, 80, 90, 100, 125, 150, 175, 200, 225 — 3500. 4470. 75. 320. — 5 — — 200 — — 200 — 30FXD6 250 — 2190. 2700. 75. 320. 5 5 — — 65 — — 35 — 30HFD6 250 — 3940. 4240. 75. 320. 5 5 — — 100 — — 65 — 30CFD6 250 — 4590. 5580. 75. 320. — 5 — — 200 — — 200 — 30JXD2 200, 225, 250, 300, 350, 400 — 2150. 2350. 130. 350. 8.75 8.75 — — 65 — — — — 30JXD6 200, 225, 250, 300, 350, 400 — 2230. 2750. 130. 350. 8.75 8.75 — — — — — 35 25 30HJD6 200, 225, 250, 300, 350, 400 — 3690. 4380. 130. 350. 8.75 8.75 — — 100 — — 65 35 30CJD6 200, 225, 250, 300, 350, 400 — 4910. 6310. 130. 350. — 8.75 — — 200 — — 150 100 30SJD6 200, 225, 250, 300, 350, 400 — — 5960. 130. 350. — 8.75 — — 65 — — 35 25 —SHJD6 200, 300, 400 — — 6610. 130. 350. — 8.75 — — 100 — — 65 35 —LXD6 450, 500, 600 — 3540. 4580. 140. 640. — — — — 65 — — 35 25 30HLD6 250, 300, 350, 400, 450, 500, 600 — 4280. 5360. 140. 640. — 8.75 — — 100 — — 65 35 30CLD6 450, 500, 600 — 6600. 9720. 140. 640. — — — — 200 — — 150 100 30SLD6 300, 400, 500, 600 — — 6600. 140. 640. — — — — 65 — — 35 25 —SHLD6 300, 400, 500, 600 — — 6680. 140. 640. — 8.75 — — 100 — — 65 35 —LMD6 500, 600, 700, 800 — 5060. 6520. 210. 1380. — 8.75 — — 65 — — 50 25 30HLMD6 500, 600, 700, 800 — 6510. 8060. 210. 1380. — 8.75 — — 100 — — 65 50 30MD6 500, 600, 700, 800 — 7450. 9500. 210. 1380. — — — — 65 — — 35 25 30HMD6 500, 600, 700, 800 — 9320. 10870. 210. 1380. — 10 — — 100 — — 65 35 30CMD6 500, 600, 700, 800 — 8010. 12160. 210. 1380. — — — — 200 — — 150 100 30SMD6 600, 700, 800 — — 10260. 210. 1380. — — — — 65 — — 35 25 —SHMD6 600, 700, 800 — — 11030. 210. 1380. — 10 — — 100 — — 65 50 —ND6 800, 900, 1000, 1200 — — 13040. 220. 1560. — — — — 65 — — 50 25 30HND6 800, 900, 1000, 1200 — — 13670. 220. 1560. — 10 — — 100 — — 65 35 30CND6 800, 900, 1000, 1200 — — 17690. 220. 1560. — — — — 200 — — 150 100 30SND6 900, 1000, 1200 — — 13030. 220. 1560. — — — — 65 — — 35 25 —SHND6 800, 1000, 1200 — — 13900. 220. 1560. — 10 — — 100 — — 65 50 —NMX 600, 700, 800 — 4590. 5930. 210. 1720. — 8.75 — — 65 — — 35 25 30HMX 600, 700, 800 — 5910. 7320. 210. 1720. — 8.75 — — 100 — — 65 50 30LMX 600, 700, 800 — 7280. 11060. 210. 1720. — 8.75 — — 200 — — 100 65 30NNX 800, 900, 1000, 1200 — 8910. 11850. 210. 1720. — 10 — — 65 — — 35 25 30HNX 800, 900, 1000, 1200 — 10490. 12430. 210. 1720. — 10 — — 100 — — 65 50 30LNX 800, 900, 1000, 1200 — 15430. 17690. 210. 1720. — 10 — — 200 — — 100 65 30For inches / millimeters conversion, see Application Data For 600V applications, ED6 available at same list price.section. Ground fault is not available on branchSensitrip breakers. HED4 3-Pole = 42,000 IRDiscount Schedule PBSB <strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 10-5910 PANELBOARDS


Sentron ® PanelboardsModifications and Additions<strong>Type</strong> <strong>P5</strong>When required, special constructionsor additions to standard panelboardsmay be specified for all factoryassembledPower and DistributionPanelboards. Below and on the nextpage are listed many of those availablefor <strong>Type</strong> S5 panelboards. In no casedo these apply to Narrow (Column)Width Lighting Panelboards orUnassembled Panelboards.List Price $Unit SpacePhases 800A 1200A (Additional inches)1-Phase 570. 700. 1.253-Phase 655. 740. 1.257. MLO Compression Lugs —Aluminum Lugs for Use WithCopper or Aluminum CableAvailable as main lugs and neutral lug.Price includes required aluminumcompression lugs. See page 10-64.6. Split Bus Ampere List Price $ List Price $ List Price $Rating Class J Class R Class T8. Compression Lugs For CircuitBreakers — See Section 6.9. Circuit Breaker Main — With1. <strong>Type</strong> 3R/12Vacu-Break Branch PanelboardsList Price appropriate main breaker panel,Price $ then add list prices of desired vacu-breakDescription 38" branches and accessories.Panelboard Construction: Single Door . . . 1485.10. Vacu-Break Main — With CircuitComplete enclosure does not requireBreaker Branch Panelboardsa trim.Price appropriate main switch panel, thenadd list price of desired circuit breaker2. Painted Finish see page 10-72. branches and accessories.11. Grounding of Panelboards3. Miscellaneous AccessoriesNon-Insulated Equipment Ground BusListPrice $ Including Ground Lug . . . . . . .StandardAll Insulated Equipment Ground BusDescriptionPanels Including Ground Lug . . .$15. per panelNameplate — laminated, engraved . . . . 50.Tamper-Resistant Screws – per panel . . 70.List4. Devices Mounted on Gutter Cover— Includes Device, Mounting —Wired or Unwired see page 10-72DescriptionST W/CPTBFI — Blown FusePrice $2240.1200.5. Feed-Thru Lugs BFI/BFT — Blown Fuse/Blown Fuse Trip 3180.GF/BFT — Ground Fault & 10810.(One Set Per Panel)Blown Fuse TripUnit SpaceBFT — Blown Fuse Trip 1985.AmpereList Price $ (Additional inches)GF w/Test Panel 10810.Rating 3-Phase 1-Phase MLO400 245. 245. 10600 455. 455. 1013. Fuse Clip Provisions800 615. 615. 17.5(Add to 250 Volts or 600 Volts Unit1200 765. 765. 17.5Prices Per Switch)30 55. 55. N/A60 55. 55. N/A100 85. 85. 160.200 85. 85. 180.400, 600 85. 85. 285.Selection10PANELBOARDSFor inches / millimeters conversion, see ApplicationData section. For use on main lug, main breaker or main switchpanels without subfeed breakers. For increase in panelboard height — Consult localsales office. Price includes increased enclosure heightif required. Ground bar not installed in box. For factory installation,add $100. List Price per panel. Price 600 Volt 7 1 /2" high units. At 250 Volts — available on 5" unit only. Class “J” clips not required on 600V twin 200A switch.Class “R” and “T” clips not available on this switch.10-62<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule PBSB


Sentron ® PanelboardsModifications and Additions<strong>Type</strong> <strong>P5</strong>14. Remote Control SwitchesSwitch <strong>Type</strong> Modification920 TAKES 20.0 unit space911≤ 800A 25" to unit space≥ 800A 30" unit spaceLEN≤ 60 AMPS 10" unit space> 60 AMPS 15" unit space15. Ground Fault on Main BreakerAmpere ListDescription Rating Price $Conventional Ground Fault includes:Ground Fault Relay, GroundSensor, CPT and Shunt Trip 800-1200 7330.Test and Monitor Panel 1070.Ground Fault add to SensitripIII breaker price (takes 5" ofunit space) 800-1200 2500.16. Time Clocks Sangamo, Tork or Paragon time clockcan be supplied, mounted in panelboardcabinet. For required increase inenclosure dimensions, consult local salesoffice. Price appropriate panelboard, thenadd list price below.19. Main BusStandard main bus and ground bus aretin plated aluminum. For copper mainbus, neutral bus and ground bus addfrom the table for each panel. CopperNeutral Bar $115. List Price.Catalog 800–1200Main Bus Number Ampere $Silver Plated Copper E 1220.1000A per sq. in. Copper D 1070.750A per sq. in. Aluminum B 645.20. Copper Lugs —For Main Lug Only PanelsStandard main lugs and neutral lugs aretin plated aluminum, UL listed for usewith aluminum/copper cables. Pricebelow is for one panel and includescopper lugs for main lugs and neutral lugs,and must be used with copper cables.Main BusListAmpere Rating Price $800-1200 225.21. Shunt Trip on Main and Branches See Breaker Section for list price on this option.SelectionListDescription Price $Time Clock (one or two pole, single ordouble throw contacts; three pole,single throw) 277V maximum withplain dial 1070.Add for —Astronomical dial 210.An omitting device 75.Reserve power or carryover 2450.Space and mounting provisions only 540.17. Circuit Breaker AccessoriesHandle Blocking DeviceBlocks handle in either the “ON” or“OFF” position — See page 10-73Padlocking Device — Padlocks in“OFF” position — See page 10-7318. Ground Fault Sensing Relay KitEquipment Protection ED Frames(30 ma) — See page 10-7322. Spanner Wrenches(for Vacu-Break Switches)ListAmpere Rating Price $30-250 460.23. Alternate LugsAmperage Box Height PriceStyle Rating Alternate Connectors Addition Addition $Deduct 5.0"800 (3)#3/0 AWG - 750 Kcmil Cu or AlUnit Spacefrom availableunit spaceDeduct 7.5"MLO 1000 (4)#3/0 AWG - 750 Kcmil Cu or AlUnit Spacefrom availableunit spaceDeduct 7.5"1200 (4)#3/0 AWG - 750 Kcmil Cu or AlUnit Spacefrom availableunit spaceMain Deduct 3.75"Switch(1)#3/0 AWG - 750 Kcmil Cu or Al or Unit Space400Vacu- (2)#3/0 AWG 250 Kcmil Cu or Al from availableBreakunit space390.510.510.125. Available in 90" high enclosure only. Unit space is42 1 /2" with Test and Monitor Panel; 45" without Testand Monitor Panel. Not available on Sensitrip III. For required unit space — consult local sales office.Price includes increased enclosure height if required. Replace ”A” in position 11 of catalog number. Shunt Trip on 100A frame breakers increases mountingheight to 6.25" for twin mounting. Must price “D” or “B” from item #19 above. See section (6) circuit breakers for 100% rated circuitbreaker requirements.10 PANELBOARDSDiscount Schedule PBSB <strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 10-63


PanelboardsModifications and Additions24. Compression Lugs<strong>Type</strong> 1 Enclosure Modifications and AdditionsSelectionStyle Amp Rating Breaker <strong>Type</strong> Compression Connectors Box Height Addition Price Addition $800 N/A (3)#3/0 AWG - 500 Kcmil Cu or AlMLO 1000 N/A (4)#3/0 AWG - 500 Kcmil Cu or Al1200 N/A (4)#3/0 AWG - 500 Kcmil Cu or Al• Revised •12/21/20073-Phase 4-Wire = $255Deduct 5.0" Unit Space 3-Phase 3-Wire = $190from available unit space 1-Phase 3-Wire = $1902-Wire = $1903-Phase 4-Wire = $350Deduct 5.0" Unit Space 3-Phase 3-Wire = $255from available unit space 1-Phase 3-Wire = $2552-Wire = $2553-Phase 4-Wire = $350Deduct 5.0" Unit Space 3-Phase 3-Wire = $255from available unit space 1-Phase 3-Wire = $2552-Wire = $255MD6, 3-Phase 4-Wire = $305HMD6, CMD6,3-Phase 3-Wire = $235800(3)#2/0 AWG - 500 Kcmil Cu or Al 0MainSMD6, SHMD6, 1-Phase 3-Wire = $235BreakerSCMD6 2-Wire = $235(S5 Only) ND6, HND6, 3-Phase 4-Wire = $3051200CND6, SND6,(4)#250 - 500 Kcmil Cu or Al 03-Phase 3-Wire = $235SHND6,1-Phase 3-Wire = $235SCND6 2-Wire = $23510PANELBOARDSPanel After Market<strong>P5</strong> Description Adder $ Price $BoxesPB860 <strong>P5</strong> box 38 W X 12.75 Dp X 60 Ht. Standard 595.PB875 <strong>P5</strong> box 38 W X 12.75 Dp X 75 Ht. Standard 595.PB890 <strong>P5</strong> box 38 W X 12.75 Dp X 90 Ht. Standard 595.PBD860 <strong>P5</strong> box 38 W X 14.50 Dp X 60 Ht. 615.PBD875 <strong>P5</strong> box 38 W X 14.50 Dp X 75 Ht. 615.PBD890 <strong>P5</strong> box 38 W X 14.50 Dp X 90 Ht. 615.Trims<strong>P5</strong>60V <strong>P5</strong> Std (4 piece trim) vented 60" Standard 615.<strong>P5</strong>75V <strong>P5</strong> Std (4 piece trim) vented 75" Standard 645.<strong>P5</strong>90V <strong>P5</strong> Std (4 piece trim) vented 90" Standard 670.<strong>P5</strong>60NV <strong>P5</strong> Std (4 piece trim) unvented 60" 615.<strong>P5</strong>75NV <strong>P5</strong> Std (4 piece trim) unvented 75" 645.<strong>P5</strong>90NV <strong>P5</strong> Std (4 piece trim) unvented 90" 670.<strong>P5</strong>60VHG <strong>P5</strong> Std (4 piece trim) vented 60" w/Hinged gutter covers 290. 910.<strong>P5</strong>75VHG <strong>P5</strong> Std (4 piece trim) vented 75" w/Hinged gutter covers 290. 935.<strong>P5</strong>90VHG <strong>P5</strong> Std (4 piece trim) vented 90" w/Hinged gutter covers 290. 965.<strong>P5</strong>60NVHG <strong>P5</strong> Std (4 piece trim) unvented 60" w/ Hinged gutter covers 290. 910.<strong>P5</strong>75NVHG <strong>P5</strong> Std (4 piece trim) unvented 75" w/Hinged gutter covers 290. 935.<strong>P5</strong>90NVHG <strong>P5</strong> Std (4 piece trim) unvented 90" w/Hinged gutter covers 290. 965.<strong>P5</strong>60VD <strong>P5</strong> Std (1 PC. Door) vented 60" Use 14.5" deep box 170. 730.<strong>P5</strong>75VD <strong>P5</strong> Std (1 PC. Door) vented 75" Use 14.5" deep box 170. 760.<strong>P5</strong>90VD <strong>P5</strong> Std (1 PC. Door) vented 90" Use 14.5" deep box 170. 785.<strong>P5</strong>60NVD <strong>P5</strong> Std (1 PC. Door) unvented 60" Use 14.5" deep box 170. 730.<strong>P5</strong>75NVD <strong>P5</strong> Std (1 PC. Door) unvented 75" Use 14.5" deep box 170. 760.<strong>P5</strong>90NVD <strong>P5</strong> Std (1 PC. Door) unvented 90" Use 14.5" deep box 170. 785.<strong>P5</strong>60VDD <strong>P5</strong> Std (1 PC. Door in door) vented 60" Use 14.5" deep box 360. 1090.<strong>P5</strong>75VDD <strong>P5</strong> Std (1 PC. Door in door) vented 75" Use 14.5" deep box 360. 1115.<strong>P5</strong>90VDD <strong>P5</strong> Std (1 PC. Door in door) vented 90" Use 14.5" deep box 360. 1140.<strong>P5</strong>60NVDD <strong>P5</strong> Std (1 PC. Door in door) unvented 60" Use 14.5" deep box 360. 1090.<strong>P5</strong>75NVDD <strong>P5</strong> Std (1 PC. Door in door) unvented 75" Use 14.5" deep box 360. 1115.<strong>P5</strong>90NVDD <strong>P5</strong> Std (1 PC. Door in door) unvented 90" Use 14.5" deep box 360. 1140.Flush Mounting KitsF860 Flush kit for <strong>P5</strong> 60" Ht. 140.F875 Flush kit for <strong>P5</strong> 75" Ht. 140.F890 Flush kit for <strong>P5</strong> 90" Ht. 140.<strong>Type</strong> 3R/12WP860 <strong>P5</strong> 3R/12 60" — 140.WP875 <strong>P5</strong> 3R/12 75" — 140.WP890 <strong>P5</strong> 3R/12 90" — 140. Required with door over breaker handles. Un-vented trims require amps per square inch bussing. Requires 14.5 deep box. No adder if ordered at time of order entry.10-64<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule PBSB


Panelboards<strong>Type</strong> <strong>P5</strong> Panelboards<strong>Type</strong> 1 BoxBox is symmetricalBox To WallMounting Holes4.375 in.[ 111 ]Dimensions10.0 in.[ 254 ]Recommended Conduit Area6.635 in.[ 169 ]36.0 in.[ 914 ]Interior To BoxMountingStubs60 in.,[ 1524 ]75 in.,[ 1905 ]90 in.[ 2286 ]6.635 in.[ 169 ]24 in.[ 610 ]30 in.[ 762 ]38 in.[ 965 ]4.375 in.[ 111 ]12.75 in.[ 324<strong>Type</strong> 3R and 3R/12 Box15.88 in.[ 403 ].375 in.[ 10 ]15.81 in.[ 402 ]MountingBracket60 in.,[ 1524 ]75 in.,[ 1905 ]90 in.[ 2286 ].375 in.[ 10 ]15.81 in.[ 402 ]38 in.[ 965 ]40 in.[ 1016 ]42 in.[ 1067 ] Dimensions are interior of the box. Add 5/8" to width for absolutedimension. Add 1/8" to height for absolute dimension.Dimensions shown in inches and millimeters [ ]..87 in.[ 22 ]14.25 in.[ 362 ]10 PANELBOARDS<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 10-65