11.07.2015 Views

KMD-901MRH - Hoshizaki America, Inc.

KMD-901MRH - Hoshizaki America, Inc.

KMD-901MRH - Hoshizaki America, Inc.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

IV. Service DiagnosisA. 10-Minute Diagnostic ProcedureThe 10 minute check out procedure is basically a sequence check which can be usedat unit start-up or for system diagnosis. Using this check out procedure will allow youto diagnose electrical system and component failures in approximately 10 minutesunder normal operating conditions of 70°F (21°C) or warmer air and 50°F (10°C) orwarmer water temperatures. Before conducting a 10 minute checkout, check for correctinstallation, proper voltage per unit nameplate, and adequate water supply. Checkthe S4 dip switch settings to assure that #3, 4, 7, 8, 9, & 10 are in the factory defaultposition. Switches 1, 2, 5, & 6 are cleaning adjustments and the settings are flexible.Check the S5 dip switch settings to assure that they are in the factory default positions.For factory defaults, see "II.C.3.a) Default Dip Switch Settings." As you go through theprocedure, check to assure the components energize and de-energize correctly. If not,those components and controls are suspect. Check for voltage at the 10‐pin connector.1) Turn power off and access the control box.2) Turn power on and place the control switch in the "ICE" position. A 5 second delayoccurs. The red "POWER OK" LED and the green "BC CLOSED" LED on the controlboard come on.3) One Minute Fill Cycle – LED 4 is on. The inlet water valve is energized. After 1 minute,the control board checks the float switch. If the float switch is closed, the unit cyclesto harvest. If closed, continue to step 4. If the float switch is open, the unit repeatsthe 1 minute fill cycle until water enters and the float switch closes (low water safetyprotection during initial start up and at the end of each harvest). Diagnosis: If the inletwater valve does not open, check for no supply voltage at water valve terminals, badcoil, or plugged screen or external filter (no water flow). If unit fails to start harvest,check for open float switch or bad 1 minute timer in control board.4) Initial Harvest Cycle – LEDs 1, 4, and 2 are on. The inlet water valve remainsenergized, the contactor coil energizes to start the compressor (and fan motor on aremote condenser unit), and the hot gas valve energizes. The inlet water valve is openduring harvest for a maximum of 6 minutes or the length of harvest minus 50 seconds,whichever is shorter. The pump motor energizes and runs for the last 50 seconds ofharvest. The evaporator warms and the thermistor senses 48°F (9°C). The controlboard then receives the thermistor's 3.9 kΩ signal and turns operation of harvest overto the harvest timer. The timer has settings of 60, 90, 120, and 180 seconds (S4 dipswitch 1 & 2). The last 50 seconds of the harvest timer countdown, the inlet water valvede‐energizes and the water pump energizes, (LED 4 goes off and LED 3 comes on).When the harvest timer countdown is complete, the freeze cycle starts. Diagnosis:Check if compressor is running, hot gas valve is open, inlet water valve still open.Average harvest cycle at factory setting is 2 to 3 minutes. How long does initial harvestlast? 1.5 minutes after initial harvest begins, touch the compressor discharge line. Isit hot? If not, check refrigerant pressures and compressor operation. If it is hot, touchthe inlet line to the evaporator. Is it hot? If it is hot and the freeze cycle is not starting,check the harvest timer adjustment, the thermistor for open circuit, the discharge linetemperature, compressor efficiency, and if the hot gas valve is fully open.33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!