4) Attach a compressed air or carbon dioxide supply to the condenser water supply linedrain valve.5) Open the water regulating valve by using a screwdriver to pry up on the spring retainerunderneath the spring. While holding the valve open, blow out the condenser using thecompressed air or carbon dioxide supply until water stops coming out.6) Recover the refrigerant and store it in an approved container.7) Disconnect the capillary tube at the condenser outlet.8) Disconnect the flare-connections of the valve.9) Remove the screws and the valve from the bracket.10) Install the new valve.11) Remove the drier, then place the new drier in position.12) Braze all fittings while purging with nitrogen gas flowing at a pressure of 3 to 4 PSIG.13) Use an electronic leak detector or soap bubbles to check for leaks. Add a trace ofrefrigerant to the system (if using an electronic leak detector), and then raise thepressure using nitrogen gas (140 PSIG). DO NOT use R-404A as a mixture withpressurized air for leak testing.14) Evacuate the system, and charge it with refrigerant. See the nameplate for the requiredrefrigerant charge.15) Connect the flare-connections.16) Close the condenser water supply line drain valve, then open the condenser watersupply line shut-off valve.17) Check for water leaks.18) Replace the panels in their correct positions.19) Turn on the power supply.G. Adjustment of Water Regulating Valve - Water-Cooled Model OnlyThe water regulating valve (also called "water regulator") is factory-adjusted. Noadjustment is required under normal use. Adjust the water regulator, if necessary, usingthe following procedures.1) Prepare a thermometer to check the condenser drain temperature. Attach a pressuregauge to the high-side line of the system.2) Five minutes after a freeze cycle starts,confirm that the thermometer reads 104°Fto 115°F (40°C to 46°C). If it does not,rotate the adjustment screw by using a flatblade screwdriver until the temperature Top Viewis in the proper range. See Fig. 1. Next,check that the reference pressure is in therange indicated in the Head Pressure tablein the Performance Data section. If it is not Fig. 1in the proper range, verify the refrigerantcharge.3) Check that the condenser drain temperature is stable.47AdjustmentScrewCW – HigherCCW – Lower

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!