9. Secure the Velcro hose-tie-downs to the hoses asnear to the CCBA as possible. Pictures below showone correct and one incorrect method. Notice thatthe incorrect method reduces hose length and willcause face piece seal to be lost when moving yourhead side to side.INCORRECTMinimal hose lengthfrom adapter to tiedownCORRECTMaximum hoselength from adapterto tie down10. POSITIVE AND NEGATIVE PRESSURE TESTBEFORE leaving the fresh-air base conduct a properPOSITIVE and NEGATIVE Pressure Test. This test MUSTbe performed WITH the Oxygen cylinder turned on. Verifythat a good face seal and proper check valve operation hasbeen achieved. Face mask seal and check valve operationis verified as follows: