TITLE: <strong>QB50</strong> m-NLP Science Unit Interface Control <strong>Document</strong>Doc. No. MSSL-<strong>QB50</strong>-ID-12001-DRAFT a4.9 Command Error HandlingACK and NACK TBD4.10 EMC requirementsTBI4.11 Power BudgetThe power budget is shown in Table 4-2. These numbers are preliminary and are TBDand TBC.Mode Power at +5V (mW) Power at +3.3V (mW)Orbit average(Duty cycleaveraged)Maximum duringUnit operationsOrbit average(Duty cycleaveraged)Maximum duringUnit operationsStandby 10 300 2 100CONT/BURSTStateBoomdeploymentTBD 500 TBD 200N/A (only runonce, 4x3secTBC)1500 0 0Table 4-2 - Power BudgetPage 11 of 27