TITLE: <strong>QB50</strong> m-NLP Science Unit Interface Control <strong>Document</strong>Doc. No. MSSL-<strong>QB50</strong>-ID-12001-DRAFT a5.3.5 OBC_SU_OFF (0xF0)This SCRIPT command is ONLY read & interpreted by the OBC to turn the OFF SU attime given by “@t”.5.3.6 OBC_SU_END (0xFF)This SCRIPT command is ONLY read & interpreted by the OBC to stop runningSCRIPT at time given by “@t”.5.3.7 SU_STDBY (0x02)This command is sent to the SU to put the SU into the STANDBY state at time given by“@t”.CMD_IDLEN= 0x02= 0x00 number of BYTES to followThe HV line is turned OFF when going to STDBY state5.3.8 SU_RSP (0x03)This command is sent to the SU to request the science response packet (after runningSU_FULL or SU_BURST command), when the RDY signal is asserted at time given by“@t”.CMD_IDLEN= 0x03= 0x00 number of BYTES to followResponse packet format is:RSP_IDLEN:Bn= 0x03= one BYTE value representing the number of 16-bit WORDS tofollow the LEN parameter= packet data in BYTESPage 15 of 27