11.07.2015 Views

Corrugated Wood Composite Panels For Structural Decking

Corrugated Wood Composite Panels For Structural Decking

Corrugated Wood Composite Panels For Structural Decking

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Figure 72: Test results of bare corrugated panel single-span test for nominal (a) 24" and(b) 32" nominal spans. ............................................................................................ 121Figure 73: Test assembly for two-span continuous strong axis static bending test........ 123Figure 74: Typical finite element model for 2’ wide two-span continuous bending test.................................................................................................................................. 124Figure 75: Test results of bare corrugated panel double-span test for nominal (a) 24" and(b) 32" nominal spans. ............................................................................................ 126Figure 76: 1 / 4 " bead adhesive on corrugated panel. ........................................................ 128Figure 77: Single-span composite deck test specimen. .................................................. 128Figure 78: <strong>Composite</strong> deck single-span bending test assembly...................................... 129Figure 79: Typical finite element model for 2’ wide single-span partial compositebending test. ............................................................................................................ 130Figure 80: Load-to-deflection versus adhesive shear modulus plots of the (a) 24” and (b)32” single-span FE and beam models..................................................................... 135Figure 81: <strong>Composite</strong> deck two-span bending test assembly ......................................... 137Figure 82: Typical finite element model for 2’ wide two-span partial composite bendingtest........................................................................................................................... 140Figure 83: Load-to-deflection versus adhesive shear modulus plots of the (a) 24” and (b)32” double-span FE and beam models.................................................................... 141Figure 84: Assembly of double-T-beam......................................................................... 144Figure 85: <strong>Composite</strong> T-beam test with two equal loads symmetrically placed. ........... 145Figure 86: Cross sectional view of prefabricated wood I-joist....................................... 147Figure 87: Cross sectional view of composite T-beam: (a) end view and (b) side view.149Figure 88: Finite element model of partial composite T-beam; (a) isometric view, (b) sideview, and (c) I-joist model. ..................................................................................... 152Figure 89: Load-to-deflection versus adhesive shear modulus of the partial composite T-beam........................................................................................................................ 154Figure 90: Schematic of the composite corrugated floor system; (a) top view, (b) sideview, and (c) front view. ......................................................................................... 159Figure 91: Mock-up floor construction; four I-joists at 32" spacing. ............................. 160Figure 92: Mock-up floor construction; ¼” diameter AFG-01 adhesive on I-joist........ 161xi

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!