c. CFA fittings for tanksconnect <strong>to</strong> tanks. There needs <strong>to</strong>be at least one 64 mm, 3 thread /25 mm x 50 British Standard Piperound male coupling (CFA MaleEnd, Pt. No. SE.03.074).Consider using a ‘tee’ <strong>to</strong> allowthe CFA fi tting on one side of thebranch and personal fi refi ghtingfi ttings on the other side of thepipe, as shown in Figure 24.Tank Outlet <strong>to</strong> have 2 inch (50.8 mm)BSP (Female) (Minimum Size)Connect <strong>to</strong>Pump UnitGalv, Hex, Nipple2 inch (50.8 mm) BSPGalv. Screwed Tee2 inch (50.8 mm) BSP (Female)Connect <strong>to</strong>CFA TankerCFA Male End(Pt. No. SE.03.074)Bell or Gate Valve2 inch (50.8 mm) BSP (Male)Bell or Gate Valve2 inch (50.8 mm) BSP (Male)Figure 24: Tank fittings <strong>to</strong> connect <strong>to</strong> CFA tankersSection 3 AdviceOn the Land: <strong>Agricultural</strong> <strong>Fire</strong> <strong>Management</strong> <strong><strong>Guide</strong>lines</strong>53