11.07.2015 Views

Read Report - ccemc

Read Report - ccemc

Read Report - ccemc

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1000 TPD CO 2 CAPTURE PLANT FEED STUDYDEVON JACKFISH 1 OILSANDS OPERATIONSFEED STUDY REPORTDEV-JA-03-001-1 (R1)The selected system comprises a “Fogger” followed by a water cooled heat exchanger. The Foggerconsists of system to spray water into the hot exhaust gas providing evaporative cooling. The watercooled exchanger then provides further cooling down to the desired Absorber inlet temperature andcondensed water is separated from the cooled exhaust gas in a two-phase separator. Heat transferredto the closed loop cooling water system is rejected to atmosphere in an air-cooled exchanger.Alternatively, flue gas cooling can be achieved by a Direct Contact Cooler (DCC) packed bed columnwhere hot exhaust gas is directly contacted with circulating water and heat transfer takes place from gasphase to liquid phase. The hot circulating water is then cooled via air-cooled heat exchanger. The initialevaluation favoured the Fogger/exchanger system over the DCC system.HTC PURENERGYPage15 (19)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!