11.07.2015 Views

Agilent 1290 Infinity LC System - T.E.A.M.

Agilent 1290 Infinity LC System - T.E.A.M.

Agilent 1290 Infinity LC System - T.E.A.M.

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Agilent</strong> <strong>1290</strong> <strong>Infinity</strong> Thermostatted Column Compartment G1316CPhysical specifications Type Specifications Comments7Weight11.2 kg (24.7 lbs)Dimensions140 x 345 x 435 mm(height x width x depth)(5.5 x 13.5 x 17 inches)Line voltage 100 – 240 VAC, ± 10 % Wide-ranging capabilityLine frequency 50 or 60 Hz, ± 5 %Power consumption 320 VA / 150W / 512 BTU MaximumAmbient operating temperature 0–55 °C (32–131 °F)Ambient non-operating temperature -40–70 °C (-40–158 °F)Humidity< 95 %, at 25–40 °C (77–104 °F) Non-condensingOperating AltitudeUp to 2000 m (6562 ft)Non-operating altitude Up to 4600 m (15091 ft) For storing the moduleSafety standards: IEC, CSA, UL Installation Category II, For indoor use only.Pollution Degree 2Research Use Only.Not for use in DiagnosticProcedures.Performance specifications Type Specifications CommentsTemperature range10 °C below ambient to80 °C (5 mL/min)10 °C below ambient to100 °C (2.5 mL/min)Temperature stability ± 0.05 °CTemperature accuracy ± 0.8 °C± 0.5 °C With calibrationColumn capacity • 2 columns of 300 mm length Up to three <strong>1290</strong> <strong>Infinity</strong>with individual solvent heating TCCs can be clustered• 3 columns of 300 mm length in a system. These willin seriesappear with a single joint• 4 columns of 100 mm length user interface in thewith opt. Low dispersion control software.*heat exchanger• 6 columns (max. 300 mm)with triple-TCC clustering andcolumn selection valves• 8 columns (max. 100 mm)with dual-TCC clustering andcolumn selection valvesWarm-up/cool-down time 5 min from ambient to 40 °C10 min from 40 – 20 °CTemperature zones• 2 (single TCC)• 4 (dual-TCC cluster)• 6 (triple-TCC cluster)Individual standby temperaturesdefinable for cluster configurations.Dead volume • 1.6 µL low dispersion heat The use of low dispersionexchangerheat exchangers is rec-• 3 µL left heat exchanger ommended. 3 µL and 6 µL• 6 µL right heat exchanger heat exchanges areavailable for backwardscompatibility.Available valves • 8 position / 9 port, 8x column The optional valve driveselection valve, min. (G1316C #058) needs to be2 <strong>1290</strong> <strong>Infinity</strong> TCCs required, present. Valve kits have to(G4230A 400 bar,be ordered as separate(G4230B 1200 bar)products.• 2 position / 6 port (G4231B),1200 bar• 2 position /10 port (G4232B),1200 bar

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!