11.07.2015 Views

Instruction Bulletin Square D Power Pack SLSPP1277 - Cazbah

Instruction Bulletin Square D Power Pack SLSPP1277 - Cazbah

Instruction Bulletin Square D Power Pack SLSPP1277 - Cazbah

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Instruction</strong> <strong>Bulletin</strong>63249-420-247A203/2007La Vergne, TN USA<strong>Square</strong> D ® <strong>Power</strong> <strong>Pack</strong> <strong>SLSPP1277</strong>Retain for future use.GENERAL INFORMATIONThe <strong>Square</strong> D ® <strong>Power</strong> <strong>Pack</strong> has a line input of 120 or 277 Vac, and asingle-pole, single-throw, relay output for the load. A full wave rectifierconverts the AC line voltage to 24 Vdc to power a low-voltage sensor viaClass 2, plenum-rated leads. The power pack can be mounted inside oroutside of an electrical junction box.FEATURES • 100 mA power output can supply up to three sensors• Single-pole, normally open relay• Rated for plenum use• Relay rated for maximum 15 A tungsten and 20 A ballast loads• Mounts to a standard 4-in. x 4-in. junction box using a 1/2-in., threadedEMT nippleINSTALLATION INSTRUCTIONSDANGERHAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH• The power pack must be installed and serviced only by qualifiedelectrical personnel.• Turn off power at the circuit breaker before beginning installation.• Always use a properly rated voltage sensing device to confirm power is off.Failure to follow these instructions will result in death or seriousinjury.Mounting ExamplesLine voltage1. Provide separate overcurrent protection in accordance with the NationalElectrical Code ® and applicable local codes.2. Use copper wire only.3. Confirm that the device rating is proper for your application.4. Set the voltage selector on the front of the unit to either 120 or 277 V,depending on your application. The unit is shipped with the selector setto 277 V.5. Mount the power pack to a suitable junction box using the 1/2-in.,threaded nipple and lock. The power pack is plenum-rated, and can bemounted to the inside or the outside of a junction box or fixture in aceiling plenum.6. Connect the power pack as shown on page 2. Use approved wire nutsfor electrical connections.TosensorLine voltage277V120VInsideTosensor277V120VOutside1


<strong>Square</strong> D ® <strong>Power</strong> <strong>Pack</strong> <strong>SLSPP1277</strong> 63249-420-247A2<strong>Instruction</strong> <strong>Bulletin</strong> 03/2007Schematic DiagramSystem DiagramHotLine voltage120/277 VacNeutralLoadBlackWhiteRelayRedVoltage selectorTransformerControlRed(+24 Vdc)Black(Common)Blue(Control)HotLine voltage120/277 VacNeutralVoltage selectorLoadBlackWhiteRedOverride OFF120V277V+24 VdcCommonControl inputBlue Blk RedSensorSpecificationsStorage TemperatureOperating TemperatureMaximum HumidityAC <strong>Power</strong> InputOutput VoltageOutput CurrentHorsepower RatingSwitching Capacity-20 °F to 150 °F (-29 °C to 65 °C)32 °F to 104 °F (0 °C to 40 °C)90% non-condensing120 or 277 Vac ± 10%, 60 Hz24 Vdc100 mA nominal1 hp @ 120 V120 Vac, 60 Hz15 A tungsten 1800 W20 A ballast277 Vac, 60 Hz20 A ballastSchneider Electric USA295 Tech Park DriveLa Vergne, TN 370861-888-<strong>Square</strong>D (1-888-778-2733)www.<strong>Square</strong>DLightingControl.comElectrical equipment should be installed, operated, serviced, and maintained only byqualified personnel. No responsibility is assumed by Schneider Electric for anyconsequences arising out of the use of this material.© 2007 Schneider Electric All Rights Reserved

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!