32 •<br />
Eliocad TM hospital signalling systems<br />
control units, mounting accessories and configuration accessories<br />
782 17<br />
Pack Cat. No. Main control units<br />
Main control unit for Call programme<br />
or Call + Nurse Present programme<br />
1 782 16 2 configurations can be programmed<br />
- Department control unit: used to group all<br />
calls from the department and those of 3 other<br />
departments via call forwarding<br />
- Centralisation control unit: used to permanently<br />
centralise all the establishment's calls<br />
Display of room numbers via seven 4-digit LED<br />
displays<br />
Display of calls in order of arrival and priority<br />
(emergency call, bathroom call, biomedical alarm,<br />
normal call, patient reassured and staff present)<br />
Indicator lights denoting call, reassurance and staff<br />
present<br />
Call signal buzzer<br />
Up to 128 rooms per control unit<br />
Automatic test to ensure correct operation every<br />
15 minutes<br />
Data stored in memory in the event of power failures<br />
Materials resistant to usual hospital cleaning agents<br />
Supplied with base for tilted mounting on a desk Can<br />
be wall-mounted with plate Cat. No. 782 76<br />
To be connected to the 230 V supply (Mosaic 2P+E<br />
socket Cat. No. 771 11) and to the computer network<br />
(RJ 45 - UTP socket,<br />
2 modules Cat. No. 786 51)<br />
Main control unit for Interphone programme<br />
1 782 17 Specifications identical to control unit<br />
Cat. No. 782 16 with the addition of an automatic<br />
switching interphone system for speaking with a<br />
room, either in confidential mode using the handset,<br />
or in hands-free mode<br />
Depending on the type of call, the interphone can be<br />
used to cancel the call, reassure the patient before<br />
staff attend to them To be connected to the 230 V<br />
supply (Mosaic 2P+E socket Cat. No. 771 11)<br />
and to the computer network (RJ 45 - UTP socket,<br />
2 modules Cat. No. 786 51)<br />
1 782 20<br />
Secondary control units<br />
Secondary control unit without interphone<br />
Wall-mounted<br />
Used in conjunction with the main control unit in<br />
another room or in a corridor<br />
Secondary control unit for Interphone<br />
programme<br />
1 782 21 Wall-mounted<br />
Specifications identical to control unit<br />
Cat. No. 782 20 with the addition of interphone<br />
equipment with handset and hands-free system for<br />
calling the room<br />
782 20 782 93<br />
782 85<br />
+<br />
Pack Cat. No. Mounting accessories for control units<br />
Flush-mounting kit for secondary control units<br />
and interphone door unit<br />
1 782 75 Used to flush-mount control units<br />
Cat. Nos. 782 20/21 and interphone door unit<br />
vertically Includes a flush-mounting box and<br />
mounting accessories<br />
Wall-mounting plate for main control unit<br />
1 782 76 Used to wall-mount main control units<br />
Cat. Nos. 782 16/17<br />
Power supply possible via DLP trunking,<br />
cross-section 50 x 150 mm<br />
1 782 93<br />
Power supply<br />
Konnex modular supply for control units<br />
230 V/29 V - 640 mA<br />
Supplied with rail and connection accessory<br />
7 modules<br />
For optimum safety and continuity of<br />
service, use a UPS<br />
Coupler and accessories<br />
For coupling several Konnex power supplies<br />
1 035 06 Coupler - 1 module<br />
5 485 50 Rail for coupler<br />
1 035 10 Connection accessory (1 module)<br />
1 782 85<br />
Configuration tool<br />
Infrared configuration tool<br />
Infrared parameter setting of interfaces, display<br />
units and control units (room nos. for interfaces,<br />
group nos. for control units)