11.07.2015 Views

Open Frame

Open Frame

Open Frame

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Charger1 0 8 ~ 3 0 0 W Power Supply or B a t t e r y C h a r g e r108W Desktop Power Supply or ChargerCASE: 909150x 140x 75 mm• AC input range selectable by switch• Protections: Short circuit / Overload /Over voltage / Over temp.• 3 color LED loading indicator• Battery under / over voltage andpolarity protection (ESC only)• Cooling by free air convection• Fixed switching frequency at 25kHz• 2 years warrantyAC input voltage range ..... 88~132VAC / 176~264VAC selectable by switchAC inrush current ............. Cold start, 40A at 230VACDC adjustment range ........ 13.5V: 12~15V, 27V: 24~30V, 54V: 48~56VOverload protection .......... 105%~135% fold back current limiting, autorecoveryOver voltage protection ..... 115%~135% rated output voltageSetup, rise, hold up time ... 200ms, 100ms, 36ms at full load and 230VACWithstand voltage ............ I/P-O/P: 3kVAC, I/P-FG:1.5kVAC, 1minuteWorking temperature ........ 0~35 O C@100%, -10 O C@80%, 60 O C@60% loadSafety standards .............. CSA 61010-1 approvedEMC standards ................. EN55022 class B, EN61000-3-2,3EN61000-4-2,3,4Packing ........................... 1.38kg ; 8pcs / 12.0kg / 1.1CUFTModel No. Output Tol. R&N Effi.ESC-120-13.5 13.5V, 0~8A ±2% 120mV 81%ESC-120-27 27V, 0~4A ±1% 150mV 83%ESC-120-54 54V, 0~2A ±1% 400mV 84%ESP-120-13.5 13.5V, 0~8A ±2% 120mV 81%ESP-120-27 27V, 0~4A ±1% 150mV 83%ESP-120-54 54V, 0~2A ±1% 400mV 84%216W Desktop Power Supply or ChargerCASE: 909150x 140x 75 mm• AC input range selectable by switch• Protections: Short circuit / Overload /Over voltage / Over temp.• 3 color LED loading indicator• Battery under / over voltage andpolarity protection (ESC only)• Built-in DC fan with fan ON/OFF autocontrol at 50 O C• Fixed switching frequency at 25kHz• 2 years warrantyAC input voltage range ..... 88~132VAC / 176~264VAC selectable by switchAC inrush current ............. Cold start, 40A at 230VACDC adjustment range ........ 13.5V: 12~15V, 27V: 24~30V, 54V: 48~56VOverload protection .......... 105%~135% fold back current limiting, autorecoveryOver voltage protection .... 115%~135% rated output voltageSetup, rise, hold up time ... 200ms, 100ms, 30ms at full load and 230VACWithstand voltage ............ I/P-O/P: 3kVAC, I/P-FG:1.5kVAC, 1minuteWorking temperature ........ 0~40 O C@100%, -10 O C@80%, 60 O C@60% loadSafety standards .............. CSA 61010-1 approvedEMC standards ................ EN55022 class B, EN61000-3-2,3EN61000-4-2,3,4Packing ........................... 1.5kg ; 8pcs / 13.0kg / 1.1CUFTModel No. Output Tol. R&N Effi.ESC-240-13.5 13.5V, 0~16A ±2% 120mV 81%ESC-240-27 27V, 0~8A ±1% 150mV 84%ESC-240-54 54V, 0~4A ±1% 400mV 85%ESP-240-13.5 13.5V, 0~16A ±2% 120mV 81%ESP-240-27 27V, 0~8A ±1% 150mV 84%ESP-240-54 54V, 0~4A ±1% 400mV 85%230W Single Output Battery Charger(PB-230-xxAD1)• 3 stage charging• Universal AC input / Full range• Built-in active PFC function, PF>0.95• Protections:Short circuit / Over voltage /Over temperature• 2 color LED loading indicator• Built-in remote ON-OFF control• Fan ON/OFF control• Low cost, high realiability• 2 years warranty300W Single Output Battery ChargerCASE: 801B190x 96x 49 mmAC input voltage range ..... 90~264VAC; 127~370VDCAC inrush current (max.) .. Cold start, 50A at 230VACOver voltage protection .... 102%~125% shut off, re-power on to recoverWithstand voltage ............ I/P-O/P: 3kVAC, I/P-FG: 1.5kVAC, O/P-FG:0.5kVACWorking temperature ........ -20 O C~+50 O C ( refer to output derating curve )Safety standards ............. UL1012(PB-230xx-AD1 only), EN60950-1 approvedEMC standards ................ EN55022 class B, EN61000-4-2,3,4,5,6,8,11,EN61000-3-2,3Packing .......................... 1.21Kg ; 12pcs / 15.5Kg / 1.29CUFTModel No. Output Effi.PB-230-12□ 14.4V, 0~16A 81.5%PB-230-24□ 28.8V, 0~8A 85.5%PB-230-48□ 57.6V, 0~4A 86.0%□= Blank, AD1; Blank= 4 pin power din, AD1= Anderson connector(except for 48V) (P type only)253x 135x 48.5 mm• Optimal 3 stage charging characteristic• AC input range selectable by switch• Passive PFC compliance toEN61000-3-2 class A (option)• Protections:Reverse polarity / Short circuit /Over voltage / Over temperature• Charger for lead-acid batteries• Built-in ON/OFF power switch• 3 poles AC inlet (IEC 320-C14)• 2 color LED loading indicator• Built-in remote ON/OFF control• Cooling by free air convection• 3 years warrantyAC input voltage range ..... 90~132VAC / 180~264VAC selectable by switchAC inrush current (max.) .. Cold start, 60A at 230VACOver voltage protection ..... 108%~125% rated output voltageWithstand voltage ............ I/P-O/P: 3kVAC, I/P-FG: 1.5kVAC, 1 minuteWorking temperature ........ -10 O C~+50 O C ( refer to output derating curve )Safety standards ............. IEC60335-2-29 CB approval by TUV(except for 48V), UL60950-1 approvedEMC standards ................ EN55022 class B, EN61000-4-2,3,4,5,6,8,11,EN61000-3-2,3 (P type)Packing ........................... 1.45kg ; 6pcs / 9.7kg / 0.95CUFTModel No. Output (20 min.) / (Continuous at 25 o C) Effi.PB-300□-12 14.4V, 20.85A / 12.5A 85%PB-300□-24 28.8V, 10.50A / 6.25A 86%PB-300□-48 57.6V, 5.3A / 3.20A 88%□ = P: with PFC; N: non PFC44

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!