<strong>Series</strong> <strong>4030</strong><br />
<strong>Long</strong> <strong>Coupled</strong> <strong>End</strong> <strong>Suction</strong> <strong>Pumps</strong><br />
LEAFLET NO: K4.110<br />
DATE: March 1998<br />
SUPERSEDES: K3.1<br />
DATE: Sept. 1995
SERIES SERIES <strong>4030</strong><br />
ARMSTRONG PUMPS - HALLMARK OF QUALITY<br />
TRADITIONAL FEATURES:<br />
❑ Back Pull Out Design<br />
❑ One Piece Baseplate<br />
❑ Armstrong - Manufacturer of pumps since 1934<br />
❑ Base mounted pump designs continuously updated<br />
❑ Traditional features combined with cutting edge concepts<br />
❑ Base Supported Radially Split Casing<br />
❑ Flexible Coupling, with Guard<br />
❑ Drain and Gauge Connections<br />
❑ Cast Iron Housing, Bronze Fitted Construction<br />
❑ All Iron and Ductile Iron Construction available<br />
❑ Designed, Manufactured, and<br />
Tested to Exacting Standards<br />
CURRENT DESIGN CONCEPTS:<br />
❑ Centerline Discharge Casing<br />
❑ Large Flow Range<br />
❑ DIN Flanged Casing<br />
❑ Pre-Lubricated and Sealed Ball Bearings<br />
❑ Confined Casing Gasket<br />
❑ Mechanical Seal with O-Ring Mounted Seat<br />
❑ Stainless Steel Shaft Sleeve
Pressure<br />
BASE MOUNTED CENTRIFUGAL PUMPS<br />
Coupling Guard<br />
Provided on all pumping units<br />
Drilled and Tapped connections<br />
for Gauges and Drain<br />
DIN flanges<br />
Radially Split Casing provides Pull Out design<br />
Allows removal of bearing assembly and<br />
impeller without disturbing pipe connections<br />
Top centerline discharge<br />
casing, self-venting to<br />
eliminate pump vapor lock<br />
Gasket, non-asbestos, confined<br />
Cast Bronze or Iron Impeller<br />
Dynamically Balanced<br />
Stainless Steel Shaft Sleeve<br />
Bearing Assembly<br />
Two anti-friction bearings,<br />
permanently lubricated, carry design<br />
loads with minimum maintenance<br />
(Oil Lube on larger sizes) Base supported casing.<br />
Eliminates need to support casing<br />
when bearing assembly is removed<br />
A heavy fabricated steel baseplate, rigidly constructed,<br />
provides for proper alignment of pump and motor<br />
Single spring Mechanical Seal<br />
leak-proof operation throughout pump range<br />
SERIES <strong>4030</strong> – SIMPLY THE BEST BASE MOUNTED PUMP<br />
DESIGN IN TODAY’S HVAC INDUSTRY!<br />
PRESSURE ➁ /TEMPERATURE CHART ➀ SERIES <strong>4030</strong><br />
250<br />
psig<br />
200<br />
psig<br />
150<br />
psig<br />
100<br />
psig<br />
50<br />
psig<br />
-18°C 10°C 38°C 66°C 93°C 121°C<br />
1724<br />
kPa<br />
B<br />
A<br />
0°F 50°F 100°F 150°F 200°F 250°F<br />
Temperature<br />
1380<br />
kPa<br />
1034<br />
kPa<br />
690<br />
kPa<br />
345<br />
kPa<br />
A - CAST IRON - PN16 flanges<br />
Standard Seal<br />
B - DUCTILE IRON - PN16 flanges to 1600 kPa<br />
PN25 1600-2500 kPa<br />
➀ - All values are based on clear, clean water<br />
Values may change with other liquids.<br />
➁ - Hydrostatic test pressure at ambient temperature<br />
is 150% maximum working pressure.
SERIES SERIES <strong>4030</strong><br />
NEED TO REDUCE SPACE REQUIREMENTS AND INSTALLATION COSTS?<br />
Base mounted pump with <strong>Suction</strong> Vertical In-Line with <strong>Suction</strong> dualArm Vertical In-Line<br />
Guide and Flo-Trex valve. Guide and Flo-Trex Valve. Incorporates two pumps in a casing with<br />
Eliminates cost and space of: Eliminates cost and space of: single inlet and outlet connections. Enables<br />
<strong>Suction</strong>: Y-Strainer All the items listed under base standby or parallel operation with only one<br />
<strong>Long</strong> Radius Elbow mounted pump, also saves: set of piping. Casing design and port valves<br />
Min. Straight Pipe Run Inertia Base with spring mounts allow one pump to be removed for service<br />
Discharge: <strong>Long</strong> Radius Elbow Flexible Pipe Connectors with the second pump still operating.<br />
Check Valve Grouting When installed with <strong>Suction</strong> Guide and<br />
Isolating Valve Field Alignment Flo-Trex valve the dualArm represents<br />
Throttling Valve Split Couplings available for ease the greatest Life Cycle Value in today’s<br />
of mechanical seal replacement commercial HVAC market.<br />
Armstrong <strong>Pumps</strong> Limited S.A. Armstrong Limited Armstrong <strong>Pumps</strong> Inc. Armstrong Darling Inc.<br />
Peartree Road, Stanway 23 Bertrand Avenue 93 East Avenue 2200 Place Transcanadienne<br />
Colchester, Essex Toronto, Ontario Buffalo, New York Montreal, Quebec<br />
United Kingdom, C03 5JX Canada, M1L 2P3 U.S.A., 14120-6594 Canada, H9P 2X5<br />
Tel.: 01206-579491 Tel.: (416) 755-2291 Tel.: (716) 693-8813 Tel.: (514) 421-2424<br />
Fax: 01206-760532 Fax: (416) 759-9101 Fax: (716) 693-8970 Fax: (514) 421-2436<br />
AP960<br />
BASE MOUNTED PUMPS<br />
TYPICAL SPECIFICATION:<br />
1.1 CIRCULATING PUMPS<br />
.1 Furnish and install, as indicated on the plans and specifications, Armstrong <strong>Series</strong> <strong>4030</strong> base mounted<br />
centrifugal pumps.<br />
.2 The pump shall be single, end suction type with radially split, top center-line discharge, self-venting casing.<br />
The casing-to-cover gasket shall be confined on the atmospheric side to prevent blow-out possibility.<br />
.3 Pump construction shall be cast iron, bronze fitted (all iron, all bronze, ductile iron) and shall be fitted with<br />
a long-life, self lubricating, drip-tight mechanical seal, with O-ring seat retainer, designed for the specified<br />
maximum temperature and pressure.<br />
.4 The shaft shall be fitted with a Stainless Steel shaft sleeve and be supported by two heavy duty ball<br />
bearings. The design shall allow Back Pull Out servicing, enabling the complete rotating assembly to be<br />
removed without disturbing the casing piping connections.<br />
.5 The pump shall be mounted on a rigid, single piece baseplate, with grouting hole, and connected by flexible<br />
coupling, with guard, to a __kW, __Hz, _ph, __volts, __rpm, __enclosure squirrel cage, induction type<br />
motor of standard (premium, __%) efficiency and suitable for direct on line/star delta starting.<br />
.6 The housing shall be hydrostatically tested to 150% maximum working pressure.<br />
.7 The unit shall be suitable for the conditions shown on the pump schedule.<br />
Armstrong SG<br />
<strong>Suction</strong><br />
Guide<br />
with<br />
Strainer<br />
ARMSTRONG ARMSTRONGER ARMSTRONGEST<br />
Armstrong FTV-S<br />
Flo-Trex<br />
Combination<br />
Valve<br />
Armstrong SG<br />
<strong>Suction</strong><br />
Guide<br />
with<br />
Strainer<br />
Armstrong FTV-A<br />
Flo-Trex<br />
Combination<br />
Valve<br />
Armstrong SG<br />
<strong>Suction</strong><br />
Guide<br />
with<br />
Strainer<br />
Our policy is one of continuous improvement and we reserve the right to alter our dimensions, designs and specifications without notice.<br />
© S.A. Armstrong Limited, 1995,1998.<br />
Armstrong FTV-A<br />
Flo-Trex<br />
Combination<br />
Valve<br />
Armstrong<br />
dualArm<br />
Vertical<br />
in-Line<br />
Pump