LocationsMelbourne (National Office)Tel +61 (0)3 9773 3200Fax +61 (0)3 9773 38112/63 Wells RoadChelsea HeightsVictoria 3196SydneyTel +61 (0)2 4647 8066Fax +61(0)2 4647 806918/151 Hartley RoadSmeaton GrangeNew South Wales 2567BrisbaneTel +61 (0)7 3219 4222Fax +61 (0)7 3219 21334/579 Kessels RoadMacGregorQueensland 4109CairnsTel +61(0)435 790 704Tel +61 (0)7 3219 4222Fax +61 (0)7 3219 213311-12 / 92 Anderson StreetManunda (Cairns)Queensland 4870AdelaideTel +61 (0)8 8350 9377Fax +61 (0)8 8350 938811/601 Anzac HwyGlenelgSouth Australia 5045PerthTel +61 (0)8 9354 9599Fax +61 (0)8 9354 956016 Gympie WayWillettonWestern Australia 6155AucklandTel +64 (0)9 414 7344Fax +64 (0)9 414 58664c Piermark DriveNorth HarbourNew ZealandWellingtonTel +64 (0)4 973 0657Fax +64(0)4 973 0658261 Waiwhetu RoadLower HuttNew ZealandFor the locations of regional distributors, visit our website:www.fansdirect.com.au / www.fansdirect.co.nzThe words <strong>Fans</strong> <strong>Direct</strong> and the impeller device logo are trade marks of <strong>Fans</strong> <strong>Direct</strong> Pty Ltd ACN 087 430 715. The entire contents of thiscatalogue are protected by copyright; no text, image, numerical or graphical data may be reproduced for any purpose without thewritten consent of <strong>Fans</strong> <strong>Direct</strong>. The MacroAir logo and written word including the words ‘THE ORIGINAL BIG FANS’ are trade marks ofMacroAir Technologies LLC. and are used under license in Australia and New Zealand by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd. The Chicago Blower logo andwritten words are trade marks of Chicago Blower Corp. and are used under license in Australia and New Zealand by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.While every effort has been made to accurately present specifications and data in this catalogue, <strong>Fans</strong> <strong>Direct</strong> accepts no liability for lossesarising from errors or omissions contained herein. As a result of continuous product development, all data and specifications are subject tochange without notice.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 1


FANSCATALOGUEContentsMacroAir – HVLS 6<strong>Fans</strong> <strong>Direct</strong> Energy SaverSeries8Chicago Blower 20Light Commercialand Residential Ventilation42Roof Mounted Centrifugal 74Roof Mounted Axial 88Duct Mounted Axial 104Duct Mounted Centrifugal &Mixed Flow2502 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


ContentsWall Mounted <strong>Fans</strong> 266Air Relief Cowls 276Smoke Spill <strong>Fans</strong> 282Bushfire Code Compliant<strong>Fans</strong> and Cowls286Sound AttenuationProducts296Car Park Ventilation 304Guide for SelectingKitchen <strong>Fans</strong>308Ancillaries, SpeedControllers & Switches312Guides and Advice 333Warranty and SaleConditions352© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 3


Interactive ToolsFan Selection At Your FingertipsWe have made the task of selecting the right fan simpler than it’s ever beenbefore by developing class leading software and making it available toindustry as a free <strong>download</strong>. <strong>Fans</strong>Select for HVAC and Chicago Select forheavy duty Chicago blowers are easy to use but very powerful tools forcontractors and design engineers.Features¨ Simple to use but fully featured for professional use¨ Displays fan cost relativities to see the budget effect of selections*¨ Shows fan output dynamically under speed control conditions*¨ Web based interface for automatic updates¨ Displays BCA compliance for selected fans*¨ Allows selection of attenuators to achieve designed sound levels*¨ Selection filters allow precise targeting of suitable fans¨ Clickable headings to sort results table*¨ Full project schedule and datasheet functions¨ Data can be exported to commonly used applications*¨ Customising options to suit user preferences*Both applications are available for <strong>download</strong> at www.fansdirect.com.au orwww.fansdirect.co.nz* Features specific to <strong>Fans</strong>Select only© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 5


FANSCATALOGUEOne overhead that won’t cost the earth.MacroAir ® brings a whole new concept in creatingcomfortable climates in big industrial spaces toAustralia and New Zealand. Until now, designing ormanaging large, high ceiling internal spaces hasmeant very expensive cooling and heating plantthat costs the earth to run. But now, all you needare some really big overhead fans.Up to seven metres in diameter, these fans aredesigned from advanced technology, but theireffect is simple. In hot weather they can move upto 10,000 cubic metres of air per minute as a gentlebreeze that cools the apparent temperature by 4to 6ºC.In winter, they move the layer of warm air at ceilinglevel, bringing it down to increase the temperaturefor people below.Ongoing running costs are a tiny fraction of anyother heating or cooling solution which also meansthe creation of harmful greenhouse gases issignificantly less too. When retrofitted alongsideexisting air conditioning systems, savings in runningcosts of up to 15% can be achieved with noreduction in people’s comfort. So whether it’s aretail space, a factory, a showroom or adistribution centre, these almost silent fans will bringcomfort to workers, shoppers and visitors alike.66 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


MacroAir - High Volume Low SpeedHVLS Fan Technology.Ranging in size up to 7.2m in diameter, HVLS fans solve air quality andimprove comfort levels in high volume buildings by seamlessly moving largeair masses at low speed. HVLS stands for High Volume, Low Speed and as afan and ventilation concept was invented by the founder of MacroAir ®Technologies, Mr. Walter Boyd. The design, mechanics, and size of HVLS fansproduces unique advantages that no other air movement technology canmatch.· Fully Encompassing Air Circulation· Creates Perceived Cooling Effect in HotWeather· De-stratifies Heat Layers for Winter Comfort· Outstanding Coverage Without Drafts· Keeps Wet, Moist Areas Drier· Long Life Mechanical Efficiencies· Reduces Heat Stress· Deters Birds and Flying Insects· Increases Worker Comfort and Productivity inFactories / WarehousesHighly Energy EfficientA large column of air "travels" further than a small one. The friction betweenmoving and stationary air occurs at the edge of the moving column. Theperimeter of a column varies directly with the diameter. And while the crosssectionalarea varies with the square of the diameter, the large column hasproportionately less periphery, and therefore, less "drag." The air column froma 900mm diameter fan has more than 6 times as much "friction interface" perM 3 as a the air column from a 6M fan.As a result of this far-reaching effect, large low-speed fans, properlyarranged, are capable of establishing continuously circulating air currentsthat transport vastly more air than smaller high-speed fans of equivalentdisplacement. The power to drive a fan increases roughly with the cube ofthe average air speed through the fan so a fan delivering air at 30 km/hrequires about 64 times as much power as one the same size delivering air at8 km/h! MacroAir HVLS fans move large volumes of air efficientlyat 2-6km/h.Diameter Motor Size Air FlowSizes and PerformanceEffectiveCoveragePowerConsumptionRPMWeight2.4m 0.75 kW 21,090 L/s 372m 2 .554 kW 172 57.2kg3.6m 0.75 kW 38,243 L/s 650m 2 .678 kW 100 71.7kg4.2m 0.75 kW 50,345 L/s 743m 2 .697 kW 86 73.5kg5.4m 0.75 kW 70,405 L/s 1394m 2 .687 kW 60 86.2kg7.2m 0.75 kW 108,427 L/s 1672m 2 .694 kW 41 94.3kgSuggested SpecificationHigh Volume Low Speed fans shallbe of the MacroAir Series suppliedby <strong>Fans</strong> <strong>Direct</strong>.High performance aerofoil designaxial impellers shall be driven byAC motors matched with heavyduty reduction gearboxes for longlife.All models to provide adjustablespeed output through VSD controland for silent running, drivesequipped with sinusoidal filters.Design Green With MacroAir ®HVLS fans create the greatest effect on internal air spaces for the lowest costand consumption of resources. Because of their inherently efficient designprinciple, costs to run works out to be about 20 cents per hour per fan. Highspeed fans, air conditioning systems (evaporative or refrigerated), allconsume vastly more energy and material resources which meanssignificantly higher Greenhouse Gas Emissions. Even where existing HVACsystems are in place, retrofitting MacroAir ® fans can greatly reduce energyconsumption.Applications for MacroAir ® HVLS Fan Systems include:· Factories and Assembly Plants· Shopping Centres· Warehouses and Distribution Centres· Produce Packing Sheds· Automotive Workshops· Sports Centres· Aircraft Hangers· School Halls”· Atriums and Foyers© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 7


FANSCATALOGUE<strong>Fans</strong> <strong>Direct</strong> Energy SaverSeries8 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


<strong>Fans</strong> <strong>Direct</strong> has been at the forefront of fan efficiency developments inAustralia and New Zealand and was the first HVAC fan supplier to offer fansequipped with EC (Electronically Commutated) motors. In 2006, <strong>Fans</strong> <strong>Direct</strong>launched the ‘Simple Control’ range to provide designers with options forhighly efficient fans with capacity for external feedback for output control.Since 2006 we have continued to develop efficient design with an expandedEC range, frequency drive controls for ultra efficient MacroAir fans and morerecently, centrifugal and axial ranges delivered with onboard speed controlmodules.Key PrinciplesThe ability to control the speed at which fans operate in response to real timeventilation demands is the basis of our energy saver range. Fan powerconsumption changes to the cube of speed reduction while air flowreduction stays proportional to reduced speed. This means that tailoring fanspeed to meet exact air flow requirements has the potential to greatlyreduce energy consumption through the removal of redundant capacity.Energy Saver AxialSensor feedback to fans equipped with frequency drives or EC motors allowsautomatic adjustment to fan output thereby minimising power used. Evenwhen installed as stand alone fans, EC and frequency drive models can bespeed balanced to provide the lowest operating costs while meetingrequired demand.Integrating ’smart fans’ with Building Management Systems (BMS) deliversunmatched flexibility for designers striving to reduce overall building energyconsumption.BenefitsEnergy SaverCentrifugal¨¨¨¨Reduced Energy Consumption / Running CostsFaster and simpler system commissioningReduced ventilation system noise<strong>Fans</strong> interface with the Building Management Systems (BMS)Ranges AvailableEnergy Saver Axial Series315Ø400Ø500Ø560Ø630ØEnergy Saver Centrifugal Series315Ø355Ø450Ø630Ø710ØEnergy Saver Centrifugal (EC-SCDQ) Series315Ø355Ø500Ø630ØThe following pages catalogue each range in detail. Selections can also bemade using our electronic selection software <strong>Fans</strong>Select <strong>download</strong>able atwww.fansdirect.com.au© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 9


FANSCATALOGUEEnergy Saver Axial SeriesEnergy Saver AxialThe Energy Saver Axial series of duct mounted axial flow fans incorporates ACmotors with on board variable speed control. Supply input can be either240V single phase or 415V three phase for maximum application flexibility.<strong>Fans</strong> can be manually speed controlled via an external on-board keypad orlinked to feedback sensors as part of existing Building Management Systems(BMS).Energy Saver AxialThe ability to control the speed at which the fan operates in response to realtime ventilation demands is the basis of our energy saver range. Fan powerconsumption changes to the cube of speed reduction while air flowreduction stays proportional to reduced speed. This means that tailoring fanspeed to meet exact air flow requirements has the potential to greatlyreduce energy consumption through the removal redundant fan capacity.ConstructionCasings for all models are of hot dipped galvanised steel to AS1650 with rollformed or fully welded flanges. Highly efficient aerofoil impellers arefabricated from pressure die cast aluminium. Impellers are balanced toISO1940 Grade G6.3. All hubs are pressure die cast aluminium alloy.TestingRated fan performance has been determined by testing to BS848 Pt1 (1998).Fan sound data has been determined by testing to AMCA 300.Wiring DiagramsRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is a condition of our warranty that all equipment supplied is installedaccording to the requirements of AS/NZS3000:2007 Australian/New Zealandwiring rules.ApplicationAll units are suitable for internal or external operation at any installed angle.The maximum ambient temperature of the fan operating environment shouldnot exceed 40°C.SelectionThe quick selection graph below indicates the range of duties available foreach fan diameter from zero to maximum speed. Each curve plots peak fanefficiency for the range of speeds available. The following pages provideadditional performance data for each fan diameter at defined speedsettings.500Energy Saver Axial SeriesSuggested SpecificationThe axial fans shall be of the EnergySaver Axial Series manufactured by<strong>Fans</strong> <strong>Direct</strong> Pty LtdHigh performance aerofoil designaxial impellers shall be driven by ACmotors incorporating on-boardvariable speed control.All models shall be performancetested to BS848 Pt1 (1998) for air flowand AMCA 300 for sound.Static Pressure (Pa)25010050251052.5630 Ø560 Ø500 Ø400 Ø315 Ø10.01 0.05 0.1 0.25 0.5 1 2.5 5Air Flow (m 3 /s)10 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Energy Saver Axial Series315 Ø400 Ø120200100180160Static Pressure (Pa)8060402016 rps12 rps19 rps24 rpsStatic Pressure (Pa)1401201008060402019 rps16 rps12 rps24 rps00.0 0.2 0.4 0.6Air Flow (m 3 /s)00.0 0.5 1.0 1.5Air Flow (m 3 /s)500 Ø560 Ø250300200250Static Pressure (Pa)1501005012 rps16 rps19 rps24 rpsStatic Pressure (Pa)2001501005012 rps16 rps19 rps24 rps00.0 1.0 2.0 3.0Air Flow (m 3 /s)00.0 1.0 2.0 3.0 4.0Air Flow (m 3 /s)630 Ø350300Static Pressure (Pa)25020015010016 rps19 rps24 rps5012 rps00.0 2.0 4.0 6.0Air Flow (m 3 /s)ModelMotor FrameSizeA B C D E F G H J KAX31DB25P - 315Ø 71 315 379 400 320 320 8 9.5 356 220 270 15AX40DB25P - 400Ø 71 400 464 400 330 320 12 10 438 290 340 18AX50DB25P - 500Ø 80 500 564 400 340 320 12 10 541 380 430 35AX56DB25P - 560Ø 90 560 644 400 370 320 16 10 605 420 470 46AX63DB25P - 630Ø 90 630 714 400 430 320 16 10 674 500 550 57Nom.Weight© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 11


FANSCATALOGUEEnergy Saver Axial SeriesFan SizeShaft Revs /secAbsorbed.kWMax. Full LoadAmpsdB(A)@ 3mSPL dB referred to 10 -12 W Type D: ducted inlet/outlet (LW)63 125 250 500 1K 2K 4K 8K24 rps 0.10953 71 70 74 68 68 67 61 52315 Ø19 rps 0.056 47 66 65 69 63 63 62 56 471.0316 rps 0.016 43 61 60 64 58 58 57 51 4212 rps 0.002 36 54 53 57 51 51 50 44 3524 rps 0.17758 76 75 80 74 73 72 66 57400 Ø19 rps 0.090 53 71 70 75 69 68 67 61 521.0316 rps 0.027 48 66 65 70 64 63 62 56 4712 rps 0.003 42 59 58 63 57 56 55 49 4024 rps 0.61860 72 73 84 77 75 72 68 61500 Ø19 rps 0.315 55 67 68 79 72 70 67 63 561.716 rps 0.093 51 62 63 74 67 65 62 58 5112 rps 0.012 44 55 56 67 60 58 55 51 4424 rps 1.02363 75 76 87 79 77 75 70 63560 Ø19 rps 0.521 57 70 71 82 74 72 70 65 582.3716 rps 0.154 53 65 66 77 69 67 65 60 5312 rps 0.019 46 58 59 70 62 60 58 53 4624 rps 1.803 65 77 78 89 82 80 77 73 66630 Ø19 rps 0.918 60 72 73 84 77 75 72 68 613.1916 rps 0.272 56 67 68 79 72 70 67 63 5612 rps 0.034 49 60 61 72 65 63 60 56 49NotesMax. Full Load Amps are shown for maximum speed.Ancillaries12 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Energy Saver Centrifugal SeriesEnergy Saver CentrifugalThe Energy Saver Centrifugal series of duct mounted centrifugal flow fansincorporates AC motors with on board variable speed control. Supply inputcan be either 240V single phase or 415V three phase for maximumapplication flexibility. <strong>Fans</strong> can be manually speed controlled via an externalon-board keypad or linked to feedback sensors as part of existing BuildingManagement Systems (BMS).Energy SaverCentrifugalThe ability to control the speed at which the fan operates in response to realtime ventilation demands is the basis of our energy saver range. Fan powerconsumption changes to the cube of speed reduction while air flowreduction stays proportional to reduced speed. This means that tailoring fanspeed to meet exact air flow requirements has the potential to greatlyreduce energy consumption through the removal redundant fan capacity.ConstructionCasings for all models are of galvanised sheet steel. Highly efficientbackward curved centrifugal impellers are matched with TEFC AC motorswith sealed for life bearings.TestingRated fan performance has been determined by testing to BS848 Pt1 (1998).Fan sound data has been determined by testing to AMCA 300.Wiring DiagramsRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is a condition of our warranty that all equipment supplied is installedaccording to the requirements of AS/NZS3000:2007 Australian/New Zealandwiring rules.ApplicationAll units are suitable for internal or external operation at any installed angle.The maximum ambient temperature of the fan operating environment shouldnot exceed 40°C.SelectionThe quick selection graph below indicates the range of duties available foreach fan diameter from zero to maximum speed. Each curve plots peak fanefficiency for the range of speeds available. The following pages provideadditional performance data for each fan diameter at defined speedsettings.Energy Saver Centrifugal SeriesSuggested SpecificationThe centrifugal fans shall be of theEnergy Saver Centrifugal Seriesmanufactured by <strong>Fans</strong> <strong>Direct</strong> PtyLtdHigh performance backwardcurved centrifugal impellers shall bedriven by AC motors incorporatingon-board variable speed control.All models shall be performancetested to BS848 Pt1 (1998) for airflow and AMCA 300 for sound.Static Pressure (Pa)100050025010050251052.5710 Ø630 Ø450 Ø355 Ø315 Ø10.01 0.05 0.1 0.25 0.5 1 2.5 5 10Air Flow (m 3 /s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 13


Energy Saver Centrifugal SeriesFANSCATALOGUE315 Ø355 Ø300350250300Static Pressure (Pa)2001501005012 rps16 rps19 rps24 rpsStatic Pressure (Pa)2502001501005012 rps16 rps19 rps24 rps00 0.2 0.4 0.6Air Flow (m 3 /s)00.0 0.3 0.5 0.8 1.0Air Flow (m 3 /s)600500450 Ø12001000630 ØStatic Pressure (Pa)40030020010024 rps19 rps16 rps12 rpsStatic Pressure (Pa)80060040020012 rps16 rps19 rps24 rps00.0 0.5 1.0 1.5 2.0Air Flow (m 3 /s)00.0 1.0 2.0 3.0 4.0 5.0Air Flow (m 3 /s)710 Ø700600Static Pressure (Pa)5004003002001009 rps12 rps16 rps00.0 1.0 2.0 3.0 4.0 5.0Air Flow (m 3 /sSize A B C kg315 500 410 445 28.8355 550 450 485 34.1450 600 550 585 45.9630 800 800 835 95.7710 850 900 935 112.414 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Energy Saver Centrifugal SeriesFan ModelShaft Revs /secAbsorbed.kWMax. Full LoadAmpsdB(A)@ 3mSPL dB referred to 10 -12 W Type D: ducted inlet/outlet (LW)63 125 250 500 1K 2K 4K 8K24 rps 0.10947 77 75 69 66 59 55 55 51315 Ø19 rps 0.056 42 72 70 64 61 54 50 50 461.816 rps 0.016 37 67 65 59 56 49 45 45 4112 rps 0.002 30 60 58 52 49 42 38 38 3424 rps 0.17751 75 78 72 71 61 63 59 52355 Ø19 rps 0.090 46 70 73 67 66 56 58 54 471.816 rps 0.027 42 65 68 62 61 51 53 49 4212 rps 0.003 35 58 61 55 54 44 46 42 3524 rps 0.61857 78 81 77 75 69 69 67 63450 Ø19 rps 0.315 51 73 76 72 70 64 64 62 583.416 rps 0.093 47 68 71 67 65 59 59 57 5312 rps 0.012 40 61 64 60 58 52 52 50 4624 rps 2.99769 90 97 90 83 83 81 80 75630 Ø19 rps 1.526 64 85 92 85 78 78 76 75 707.716 rps 0.452 59 80 87 80 73 73 71 70 6512 rps 0.057 52 73 80 73 66 66 64 63 58710 Ø16 rps 1.883 61 85 90 86 75 73 71 70 6812 rps 0.795 4.854 78 83 79 68 66 64 63 619 rps 0.126 47 70 75 71 60 58 56 55 53NotesMax. Full Load Amps are shown for maximum speed.Ancillaries© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 15


Energy Saver Centrifugal (EC-SCDQ) SeriesFANSCATALOGUEEnergy Saver Centrifugal (EC-SCDQ)The Energy Saver Centrifugal (EC-SCDQ) series of duct mounted fansincorporates very high efficiency electronically commutated DC motors withon board infinitely variable control modules. These fans are AC powered withcontrol and power conversion electronics integrated into the motor. Motorspeeds can be controlled with 0-10V input signal or 10K potentiometer.Energy SaverCentrifugal EC-SCDQThe ability to control the speed at which the fan operates in response to realtime ventilation demands is the basis of our energy saver range. Fan powerconsumption changes to the cube of speed reduction while air flowreduction stays proportional to reduced speed. This means that tailoring fanspeed to meet exact air flow requirements has the potential to greatlyreduce energy consumption through the removal redundant fan capacity.ConstructionCasings for all models are of galvanised sheet steel. Backward curvedcentrifugal impellers are matched with very high efficiency DC external rotormotors incorporating sealed for life bearings.TestingRated fan performance has been determined by testing to BS848 Pt1 (1998).Fan sound data has been determined by testing to DIN 24163 (1998).Wiring DiagramsRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is a condition of our warranty that all equipment supplied is installedaccording to the requirements of AS/NZS3000:2007 Australian/New Zealandwiring rules.ApplicationAll units are suitable for internal or external operation at any installed angle.SelectionThe quick selection graph below indicates the range of duties available foreach fan diameter from zero to maximum speed. Each curve plots peak fanefficiency for the range of speeds available. The following pages provideadditional performance data for each fan diameter at selected speedsettings. The data provides a guide to performance only as fan speed isinfinitely variable.Suggested SpecificationThe centrifugal fans shall be of theEnergy Saver Centrifugal (EC-SCDQ)Series manufactured by <strong>Fans</strong> <strong>Direct</strong>Pty Ltd.1000500Energy Saver Centrifugal (EC-SCDQ) SeriesHigh performance backward curvedcentrifugal impellers shall be driven byelectronically commutated DCmotors with on board infinitelyvariable control modules.All models shall be performancetested to BS848 Pt1 (1998) for air flowand DIN 24163 (1998) for sound.Static Pressure (Pa)25010050251052.5630 Ø500 Ø355 Ø315 Ø10.01 0.05 0.1 0.25 0.5 1 2.5 5Air Flow (m 3 /s)16 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Energy Saver Centrifugal (EC-SCDQ) Series315 Ø355 Ø700800600700Static Pressure (Pa)50040030020010037 rps31 rps26 rps20 rpsStatic Pressure (Pa)60050040030020010018 rps23 rps28 rps33 rps00.1 0.3 0.5 0.7Air Flow (m 3 /s)00 0.2 0.4 0.6 0.8 1 1.2Air Flow (m 3 /s)Static Pressure (Pa)500 Ø100090080070060025 rps50021 rps40017 rps30014 rps20010000.0 1.0 2.0 3.0Air Flow (m 3 /s)Static Pressure (Pa)9008007006005004003002001000630 Ø20 rps17 rps14 rps11 rps0 1.5 3 4.5Air Flow (m 3 /s)Size A B C D kg315 Ø 480 410 445 350 35355 Ø 520 450 485 410 40500 Ø 720 650 685 525 50630 Ø 870 800 835 545 60© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 17


Energy Saver Centrifugal (EC-SCDQ) SeriesFANSCATALOGUEFan ModelShaft Revs /secAbsorbed.kWMax. Full LoadAmpsdB(A)@ 3mSPL dB referred to 10 -12 W Type D: ducted inlet/outlet (LW)63 125 250 500 1K 2K 4K 8K37 rps 2.9457 - 69 76 75 70 67 72 38315 Ø †31 rps 1.81 53 - 66 72 71 66 63 68 640.526 rps 1.01 49 - 61 68 66 62 59 63 5920 rps 0.49 43 - 55 62 60 56 53 58 5433 rps 0.4758 - 63 70 74 75 71 62 57355 Ø †28 rps 0.29 54 - 59 66 70 71 67 58 530.523 rps 0.16 49 - 54 61 65 66 62 53 4818 rps 0.08 44 - 49 56 60 61 57 48 4325 rps 2.6562 - 71 78 77 77 73 76 66500 Ø ‡21 rps 1.63 58 - 67 74 73 73 69 72 634.1718 rps 0.91 54 - 63 69 68 69 65 67 6814 rps 0.44 47 - 57 63 63 63 59 61 5220 rps 2.7559 75 87 85 75 72 68 64 63630 Ø ‡17 rps 1.69 57 73 85 83 73 70 66 62 614.3314 rps 0.94 53 68 80 78 68 65 61 57 5611 rps 0.46 45 60 72 70 60 57 53 49 48NotesSound and Electrical Data is based on peak power at each speed.† 240V single phase input‡ 415V three phase inputAncillaries18 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 19


FANSCATALOGUE20 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Chicago Blower: Overview 22Design 51 - SWSI & DWDI CentrifugalBlowers24Design 51 - SWSI Block Dimensions andWeights26Drive Arrangements, Rotation andDischarge28D90 - Centrifugal Plug <strong>Fans</strong> 30D10 - Backward Inclined Centrifugal Blower 32IRT - Industrial Radial Tip <strong>Fans</strong> 33IAF - Industrial Aerofoil <strong>Fans</strong> 34AF/BC - Custom Heavy Duty <strong>Fans</strong>35D53 - Single Stage Pressure Blower36D2300 - Pressure Air <strong>Fans</strong>37FRP - Centrifugal <strong>Fans</strong> 38FRP - Tube Axial <strong>Fans</strong>39D47 - Adjustable Pitch Vane Axial 40© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 21


Chicago Blower: OverviewFANSCATALOGUE<strong>Fans</strong> <strong>Direct</strong> has partnered with Chicago Blower Corp. (U.S.) to offer a fullrange of high performance centrifugal and axial fans / blowers throughoutAustralasia. With access to over 50 years of Chicago Blower’s extensiveengineering experience and AMCA certified designs, <strong>Fans</strong> <strong>Direct</strong> is equippedto offer world class fans and blowers to satisfy almost any requirement.All drafting and fabrication is handled in-house by a team of engineers andproduction specialists with decades of experience on projects throughoutour region.We offer fans and air movement solutions for:¨¨¨¨¨¨HVAC industryIndustrial processingHeavy duty processingFood industryMaterials handling industryPollution controlWe also offer the following services:¨¨¨¨Selection, design and manufacture of fansRepair / retro fit existing fansOnsite installation adviceCustomised solutions to unique requirements.Range of applications:Clean Air - Featuring our Design 51, backward inclined aerofoil and laminarbladed fans These fans are mainly used in the HVAC industry for supply orexhaust air applications.Dirty Air - This range includes Backward Inclined, Radial Tip and RadialBladed fans. The fans are constructed from rugged steel, making them idealfor dust conveying or other industrial airstreams, erosive installations, andmaterial handling applications.Process <strong>Fans</strong> - Designed for process applications such as boilers, incinerators,pollution control and high pressure systems. Various blade types are matchedto application requirements.High Pressure <strong>Fans</strong> - Designed for combustion air, pneumatic conveying, andother higher pressure applications. A wide range of sizes and configurationsassure a selection for every need.Highly Corrosive Applications - Fibreglass Reinforced Plastic (FRP) <strong>Fans</strong> resistsevere corrosives. Centrifugal blade types and vane-axial are available tosuit any airstream or installation.Axial Bladed <strong>Fans</strong> - Vane-axial fans are generally used in variable HVACsystems and in light industrial applications such as fume exhaust.Fan Components – for OEM requirements, airfoil and backwardly inclinedimpellers, inlet cones, inlet vane controls, housings and axial airfoil impellersare available for packaged equipment applications.22 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


General Construction and TestingUnless otherwise stated, fans are constructed according to the following;Backward inclined centrifugal impellers of laminar or aerofoil blade profile.Cases are fabricated from hot rolled steel plate and are fully welded incompliance with AS1594-1992.<strong>Fans</strong> are finished with an anti-corrosive primer with a wide range ofspecialised finishes readily available.Impellers are dynamically balanced in-house to grade G6.3.Each fan shaft is machined from CS1030 bright steel in compliance withAS1443-1983.Rated fan performance has been tested in accordance with therequirements of AMCA Standard 210.Rated fan sound performance has been tested in accordance with therequirements of AMCA Standard 300.General Ancillary Equipment¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨Access panelOutlet damperVariable Speed DriveFlanged Inlet and/or outletMatching inlet and/or outlet flangeInlet screenInlet boxShaft sealShaft cooling wheelHousing drainSplit housingSpark resistant constructionVibration isolatorsStainless steel or aluminium constructionAttenuatorsProduct SelectionThe following section (Design 51 SWSI & DWDI) includes reference data toassist with general blower selections. For SWSI and DWDI blower needs inHVAC applications, <strong>Fans</strong> <strong>Direct</strong> offers sophisticated selection software whichis simple to use and provides comprehensive blower selection functionality.<strong>Fans</strong>Select is available for free, instant <strong>download</strong> at www.fansdirect.com.auFor the full range of Chicago fans and blowers to suit all applications, <strong>Fans</strong><strong>Direct</strong> also offers a specialised software package, Chicago Select, which canalso be <strong>download</strong>ed instantly through our website, www.fansdirect.com.au.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 23


Design 51 - SWSI & DWDI Centrifugal BlowersFANSCATALOGUEproductD51 - SWSI & DWDI BlowersImpeller mm336 - 2000Duty SWSIup to, 105 m 3 /sup to, 5.0 kPaup to, 450° CDuty DWDIup to, 200 m 3 /sup to, 5.0 kPaup to, 65° CapplicationClean air applications including HVACDescriptionDesign 51 SWSI and DWDI, Aerofoil and Laminar impellers have idealcharacteristics for variable air volume systems. With a smooth, steep pressurecurve (graph below), changes in pressure cause only minor changes involume. The broad, high, efficiency curve offers a wide range of selectionsfrom each fan size along with a wide operating range. The smooth stable airflow over the entire performance range is the result of Chicago’s Deeplyspun inlet cones, impeller cones and aerofoil blades.100D51 Performance Characteristics100Drive ArrangementsSWSIArrangement 1Arrangement 3Arrangement 4Arrangement 7Arrangement 8Arrangement 9Ancillary Equipment¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨DWDIArrangement 3Arrangement 7Access panelOutlet damperVariable Speed DriveFlanged Inlet and/or outletMatching inlet and/or outletflangeInlet screenInlet boxShaft sealShaft cooling wheelHousing drainSplit housingSpark resistant constructionVibration isolatorsStainless steel or aluminiumconstructionSpecial paint and coatingsAttenuators% Pressure8060402000 20 40 60 80 100% VolumeConstructionImpellers are fully welded from heavy gauge steel to deliver structuralintegrity and operational longevity. Material gauges for each impeller sizehave been modelled using finite element analysis. Spun steel impeller conesoptimise air flow while precision balancing assures dependable vibration freeoperation. Fan housings are of continuously seam welded steel constructionwith steel bearing supports. Stiffening braces at close intervals eliminate casedistortion due to variations in air pressure and flow. Precision shafts are ofmachined, ground and polished SAE 1040 to 1045 Steel. Heavy duty SKF orsimilar self aligning ball or roller type bearings are used as standard.TestingRated fan performance has been tested in accordance with therequirements of AMCA Standard 210. Rated fan sound performance hasbeen tested in accordance with the requirements of AMCA Standard 300.SelectionThe quick selection charts opposite, enable the selection of the most efficientfan for a given duty. To determine the most efficient fan size, locate theintersection of the required volume (m 3 /s) and static pressure (Pascals) on theappropriate graph. The size to the right of this point is the correct selection.806040200% Efficiency and PowerStatic PressureEfficiencyPower24 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


36003000D51 - SWSI2000Static Pressure (Pa)10008004002000.3 0.5 0.8 1.0 1.5 2.0 2.5 5.0 10.0 25.0 50.0Volume (m 3 /s)36003000D51 - DWDI2000Static Pressure (Pa)10008004002001000.4 0.8 1.6 3.2 4.0 8.0 16.0 32.0 80Volume (m 3 /s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 25


FANSCATALOGUEDesign 51 - SWSI Block Dimensions and WeightsCW.0CW.45CW.90CW.135 CW.180 CW.225CW.270Drive ArrangementModelImpellerØA AA B C CB CC CD D E F FF G H J135 336 359 332 277 370 490 370 420 260 311 527 590 282 332 236150 370 403 365 304 390 530 390 440 286 343 565 641 310 365 260165 411 437 405 338 415 550 415 465 317 380 611 984 344 406 288182 452 486 446 371 445 590 445 495 349 418 661 741 379 446 316200 500 527 493 409 475 640 475 525 386 462 715 810 418 493 350222 548 595 539 447 505 700 505 555 422 506 769 885 458 540 383245 610 649 600 498 545 750 545 595 470 563 841 963 510 600 426270 672 716 661 547 595 810 595 645 517 620 919 1049 561 661 469300 740 806 727 603 650 900 650 700 569 682 1012 1159 618 728 516330 822 873 808 670 695 930 695 745 632 758 1101 1237 686 808 573365 903 973 887 736 715 1020 715 765 694 832 1171 1357 753 887 629402 1000 1067 982 812 800 1160 800 850 768 921 1316 1523 834 982 697445 1103 1185 1085 905 875 1210 875 925 849 1018 1443 1631 921 1085 770490 1219 1301 1198 999 935 1320 935 985 938 1124 1566 1789 1018 1199 850542 1343 1447 1320 1099 1020 1450 1020 1070 1033 1238 1712 1967 1121 1320 936600 1486 1599 1460 1215 1115 1590 1115 1165 1142 1369 1878 2165 1240 1460 1036660 1645 1745 1615 1345 1225 1740 1225 1275 1264 1515 2066 2382 1372 1616 1146730 1808 1942 1776 1479 1325 1920 1325 1375 1389 1666 2251 2622 1508 1777 1260807 2000 2148 1964 1634 1470 2150 1470 1520 1536 1842 2486 2918 1668 1965 1393ModelImpellerØL M N P Q R S T W X Y Z ZA Weight*135 336 43 80 43 271 43 25 410 311 400 406 362 311 430 100150 370 43 80 43 298 43 25 410 337 450 438 394 337 470 110165 411 43 80 43 332 43 25 410 368 475 480 432 368 515 120182 452 43 80 43 365 43 25 475 400 500 520 470 400 560 140200 500 43 100 43 403 43 25 475 411 525 543 487 411 635 160222 548 53 100 43 441 53 25 475 448 575 590 532 448 690 200245 610 53 100 43 492 53 25 510 495 600 650 587 495 770 230270 672 53 120 43 541 53 25 510 543 650 710 654 543 845 260300 740 53 130 53 597 53 25 510 594 725 780 708 594 905 310330 822 53 130 53 664 53 25 560 657 750 860 783 657 975 390365 903 53 130 53 730 53 25 610 721 825 940 857 721 1070 480402 1000 53 130 79 806 53 25 635 794 925 1058 946 794 1150 580445 1103 70 140 79 897 70 25 710 872 975 1157 1040 872 1250 800490 1219 70 160 79 991 70 25 735 959 1050 1271 1146 959 1400 900542 1343 70 200 79 1091 70 25 750 1057 1200 1394 1262 1057 1560 1120600 1486 70 200 79 1207 70 25 750 1172 1275 1534 1394 1172 1736 1430660 1645 70 200 79 1337 70 25 800 1300 1375 1688 1565 1300 1935 1790730 1808 71 200 79 1471 71 25 850 1443 1550 1850 1716 1443 2145 2410807 2000 81 200 79 1626 81 25 900 1615 1725 2062 1916 1615 2435 3000* Weight for Arrangement 9 Fan, excluding motorK42046050055060465271378085894010251134124213621482150816891842202626 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Design 51 - DWDI Block Dimensions and WeightsCW.0CW.45CW.90CW.135 CW.180 CW.225CW.270Drive ArrangementModelImpellerØA AA B C CB CC CD D E F FF G H135 336 359 332 490 255 490 370 370 260 311 527 590 282 332150 370 403 365 541 277 530 390 392 286 343 565 641 310 365165 411 437 405 601 303 550 415 418 317 380 611 984 344 406182 452 486 446 662 328 590 445 443 349 418 661 741 379 446200 500 527 493 731 359 640 475 499 386 462 715 810 418 493222 548 595 539 801 389 700 505 529 422 506 769 885 458 540245 610 649 600 890 428 750 545 568 470 563 841 963 510 600270 672 716 661 979 467 810 595 607 517 620 919 1049 561 661300 740 806 727 1081 520 900 650 685 569 682 1012 1159 618 728330 822 873 808 1200 672 930 695 837 632 758 1101 1237 686 808365 903 973 887 1318 723 1020 715 913 694 832 1171 1357 753 887402 1000 1067 982 1460 860 1160 800 1050 768 921 1316 1523 834 982445 1103 1185 1085 1615 927 1210 875 1147 849 1018 1443 1631 921 1085490 1219 1301 1198 1785 1000 1320 935 1240 938 1124 1566 1789 1018 1199542 1343 1447 1320 1966 1078 1450 1020 1318 1033 1238 1712 1967 1121 1320600 1486 1599 1460 2174 1169 1590 1115 1409 1142 1369 1878 2165 1240 1460660 1645 1745 1615 2404 1269 1740 1225 1539 1264 1515 2066 2382 1372 1616730 1808 1942 1776 2647 1373 1920 1325 1663 1389 1666 2251 2622 1508 1777807 2000 2148 1964 2927 1494 2150 1470 1834 1536 1842 2486 2918 1668 1965ModelImpellerØJ K L M Q R W X Y Z ZA Weight*135 336 236 420 424 344 75 25 400 406 362 311 510 150150 370 260 460 470 370 75 25 450 438 394 337 550 170165 411 288 500 530 400 75 25 475 480 432 368 595 180182 452 316 550 563 433 75 25 500 520 470 400 640 210200 500 350 604 600 470 100 25 525 543 487 411 715 240222 548 383 652 650 520 100 25 575 590 532 448 770 310245 610 426 713 694 564 100 25 600 650 587 495 850 350270 672 469 780 751 621 100 25 650 710 654 543 925 430300 740 516 858 835 675 125 25 725 780 708 594 1005 470330 822 573 940 904 744 125 25 750 860 783 657 1075 550365 903 629 1025 963 803 150 25 825 940 857 721 1170 640402 1000 697 1134 1037 877 150 25 925 1058 946 794 1300 910445 1103 770 1242 1114 954 180 25 975 1157 1040 872 1400 1100490 1219 850 1362 1249 1059 200 25 1050 1271 1146 959 1550 1310542 1343 936 1482 1360 1170 200 25 1200 1394 1262 1057 1710 1520600 1486 1036 1508 1471 1281 200 25 1275 1534 1394 1172 1886 1930660 1645 1146 1689 1587 1397 230 25 1375 1688 1565 1300 2085 2520730 1808 1260 1842 1715 1525 250 25 1550 1850 1716 1443 2295 3100807 2000 1393 2026 1860 1670 300 25 1725 2062 1916 1615 2585 3860* Weight for Arrangement 3 Fan and Base, excluding motor© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 27


FANSCATALOGUEDrive Arrangements, Rotation, Discharge and Motor PositionsArrangements of Drive<strong>Direct</strong>ion of Rotation andDischargeCW.0ACW.0Arrangement 1. SWSIFor belt or direct driveconnection. Wheeloverhung. Two bearings onbase.Arrangement 2. SWSIFor belt or direct driveconnection. Wheeloverhung. Bearings inbracket supported by fanhousing.Arrangement 3. SWSIFor belt or direct driveconnection. Wheeloverhung. One bearing oneach side and supportedby fan housing. Notrecommended for wheelsizes of 672mm or smaller.CW.45ACW.45CW.90ACW.90Arrangement 3. DWDIFor belt or direct driveconnection. Wheeloverhung. Onebearing on each sideand supported by fanhousing.Arrangement 4. SWSIFor direct drive. Wheeloverhung on primemover shaft. Nobearings on fan. Baseor equivalent for primemover.Arrangement 7. SWSIFor belt or direct driveconnection.Arrangement 3 plusbase for prime mover.Not recommended forwheel sizes of 672mmCW.135ACW.135CW.180ACW.180Arrangement 7. DWDIFor belt or direct driveconnection.Arrangement 3 plusbase for prime mover.Arrangement 8. SWSIFor belt or direct driveconnection.Arrangement 1 plusbase for prime mover.Arrangement 9. SWSIFor belt drive.Arrangement 1 designedfor mounting primemover on side of base.CW.225ACW.225Motor Position, Belt DriveCW.270ACW.270Location of motor is determined by facing the drive side ofthe fan and designating the motor position by letters W, X,Y or Z as required.<strong>Direct</strong>ion of Rotation is determinedfrom the drive side for either SWSI orDWDI fans. The driving side of asingle inlet fan is considered to bethe side opposite the inlet regardlessof the actual location of the drive.For fans inverted for ceilingsuspension, <strong>Direct</strong>ion of Rotationand Discharge is determined whenthe fan is resting on the floor.28 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 29


D90 - Centrifugal Plug <strong>Fans</strong>FANSCATALOGUEproductD90 - Centrifugal Plug <strong>Fans</strong>Impeller mm355 - 1486dutyup to, 48 m 3 /sup to, 2.3 kPaup to, 65° CapplicationClean air applications including HVAC, Air Handling UnitsDescriptionThe D90 range of Plug <strong>Fans</strong>, offer a practical and economical designalternative for air handling and conditioning systems. They feature an unhousedimpeller that installs directly within a plenum, thereby eliminating thedownstream discharge. The fan can be installed either horizontally orvertically. Without the conventional scroll, the Plug Fan provides the requiredperformance in less space. It is ideal for use in built-up units and factory builtair handling units. They are also ideal for retro fit applications where thesystem performance needs to be expanded and additional space is notavailable. The impeller is a specialized European design and includes arotating diffuser which improves the efficiency of the fan while reducing noiselevels.Drive ArrangementThe D90 Plug Fan range is available in Drive Arrangement 4Please refer to our standard designation sheet for further explanation of theabove arrangement.ConstructionImpellers are fully welded to deliver structural integrity and operationallongevity. Material gauges for each impeller size have been modelled usingfinite element analysis. Spun steel impeller cones optimise air flow whileprecision balancing assures dependable vibration free operation. Precisionshafts are of machined, ground and polished SAE 1040 to 1045 Steel. Heavyduty SKF or similar self aligning ball or roller type bearings are used asstandard. <strong>Fans</strong> are supplied with powder coat finish as standard.TestingRated fan performance has been tested in accordance with therequirements of AMCA Standard 210. Rated fan sound performance hasbeen tested in accordance with the requirements of AMCA Standard 300.SelectionThe quick selection chart (opposite page) enable the selection of the mostefficient fan for a given duty. To determine the most efficient fan size, locatethe intersection of the required volume (m 3 /s) and static pressure (Pascals) onthe graph. The size to the right of this point is the correct selection.Ancillary Equipment¨¨¨¨¨¨Variable Speed DriveInlet guardSpark resistant constructionVibration isolatorsStainless steel or aluminium constructionSpecial paint and coatings30 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


D90 - Plug <strong>Fans</strong>360030002000Static Pressure (Pa)10008004002001000.5 1.0 1.5 2.5 5.0 10.0 25.0 50.0 90.0Volume (m 3 /s)D90 - Pedestal MountD90 - Flange MountDrive Side ViewEnd ViewTop ViewSide ViewModel Impeller Ø A B C Min C Max D E WeightD90-13 355 550 550 568 593 230 275 90D90-15 400 550 550 593 633 255 275 105D90-16 450 675 675 628 758 280 338 170D90-20 500 675 675 663 793 315 338 190D90-22 560 750 850 698 903 350 425 250D90-24 630 750 850 738 998 390 425 305D90-27 710 1075 1075 813 1048 440 538 345D90-30 800 1075 1075 888 1178 490 538 450D90-36 900 1350 1350 1048 1248 560 675 565D90-40 1000 1350 1350 1183 1338 620 675 720D90-44 1103 1450 1450 1600 1710 880 725 1030D90-49 1219 1550 1550 1700 1885 950 775 1290D90-54 1343 1700 1700 1825 2060 1075 850 1950D90-60 1486 1850 1850 1915 2250 1120 925 2575© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 31


D10 - Backward Inclined Centrifugal BlowerFANSCATALOGUEproductDesign 10 Backward Inclined Centrifugal BlowerImpeller mm565 - 1850Dutyup to, 60 m 3 /sup to, 7.5 kPaup to, 450° CapplicationDirty and /or corrosive air applicationsDescriptionDesign 10 is a rugged multi-purpose centrifugal fan equipped with BackwardInclined impellers suited for harsh duty applications. With heavier blades toresist erosion and corrosion, the Design 10 fan provides reliable operation incontaminated air with minimal maintenance.ApplicationThe backward inclined blades are designed to handle corrosive or dustyairstreams. Typical applications include oven circulators, dust collectors, fumeexhausters and emission control systems. The Design 10 is also suited for hightemperature application of up to 450°C. The solid steel blades are ideal forcustom applied corrosion resistant coatings.ConstructionImpellers are fully welded to deliver structural integrity and operationallongevity. Spun steel impeller cones optimise air flow while precisionbalancing assures dependable vibration free operation. Fan housings are ofcontinuously seam welded steel construction with steel bearing supports.Stiffening braces at close intervals eliminate case distortion due to variationsin air pressure and flow. Shafts are of machined, ground and polished SAE1040 to 1045 Steel. Heavy duty SKF or similar self aligning ball or roller typebearings are used as standard.Features¨ Backward inclined impeller with heavy flat blades that resist corrosion¨ Smooth steep pressure curve¨ Non-overloading power characteristic¨ Spun steel impeller cone optimizes air flow¨ Continuously welded heavy steel plate construction¨ Packaged fans with motor and accessories are run tested andshipped ready to installTestingRated fan performance has been tested in accordance with therequirements of AMCA Standard 210. Rated fan sound performance hasbeen tested in accordance with the requirements of AMCA Standard 300.Selection and SpecificationFor the full range of Chicago fans and blowers to suit all applications, <strong>Fans</strong><strong>Direct</strong> offers a specialised software package, Chicago Select, which can be<strong>download</strong>ed instantly through our website, www.fansdirect.com.au. Forspecialist technical advice contact the Chicago Blower Division of <strong>Fans</strong><strong>Direct</strong> - Australia 1300 733 833 NZ 0800 100 32632 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


IRT - Industrial Radial Tip <strong>Fans</strong>productIRT - Industrial Radial Tip <strong>Fans</strong>Impeller mmAbove 750Dutyup to, 160 m 3 /sup to, 21 kPaup to, 450° CapplicationDirty and /or corrosive air applicationsDescriptionIndustrial Radial Tip (IRT) fan offers exceptional efficiency, performance,reliability and versatility with a choice of belt drive or direct drivearrangements.ApplicationIndustrial <strong>Fans</strong> with radial tip impellers are designed for handling dusty, dirtyairstreams while providing excellent operating efficiencies. To maintainoptimum performance over a wide range of volume and pressure, differentimpeller designs are needed. To fulfil this need, RT Radial Tip fans are offeredin a family of five impeller designs with overlapping performance envelopes.ConstructionImpellers are fully welded to deliver structural integrity and operationallongevity. Spun steel impeller cones optimise air flow while precisionbalancing assures dependable vibration free operation. Fan housings are ofcontinuously seam welded steel construction with steel bearing supports.Stiffening braces at close intervals eliminate case distortion due to variationsin air pressure and flow. Shafts are of machined, ground and polished SAE1040 to 1045 Steel. Heavy duty SKF or similar self aligning ball or roller typebearings are used as standard.Features¨ Five standard impeller designs with overlapping performanceenvelopes to match specific volume and pressure demands¨ Wide range of fan arrangements to suit installation requirements andmotor size¨ Rugged, continuously welded heavy steel plate construction¨ Custom design, construction and options built to customerspecificationsTestingRated fan performance has been tested in accordance with therequirements of AMCA Standard 210. Rated fan sound performance hasbeen tested in accordance with the requirements of AMCA Standard 300.Selection and SpecificationFor the full range of Chicago fans and blowers to suit all applications, <strong>Fans</strong><strong>Direct</strong> offers a specialised software package, Chicago Select, which can be<strong>download</strong>ed instantly through our website, www.fansdirect.com.au. Forspecialist technical advice contact the Chicago Blower Division of <strong>Fans</strong><strong>Direct</strong> - Australia 1300 733 833 NZ 0800 100 326© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 33


IAF - Industrial Aerofoil <strong>Fans</strong>FANSCATALOGUEproductIAF - Industrial Aerofoil <strong>Fans</strong>Impeller mm685 - 1680Dutyup to, 60 m 3 /sup to, 7.5 kPaup to, 450° CapplicationDirty and /or corrosive air applicationsDescriptionThe IAF is recognised for heavy duty construction. Housings are stronglybraced to resist high pressure movement. Shafts and bearings are sized forbelt drive duty and provide years of uninterrupted life. Split pillow block rollerbearings are standard on all IAF fans. Impellers are dynamically balanced forsmoother running. Deep spun inlet cones guide the air into the impeller andover its hollow aerofoil shaped blades, providing maximum efficiency andminimum sound levels. Static efficiencies exceed 80%, reducing the energyneeded to move each cubic metre of air.ApplicationThe IAF is a Industrial Aerofoil Fan with proven performance and provenreliability through twenty years and hundreds of installations. Engineers andusers specify the IAF for many high pressure applications, such as supply air,combustion air, product cooling and drying.ConstructionImpellers are fully welded to deliver structural integrity and operationallongevity. Spun steel impeller cones optimise air flow while precisionbalancing assures dependable vibration free operation. Fan housings are ofcontinuously seam welded steel construction with steel bearing supports.Stiffening braces at close intervals eliminate case distortion due to variationsin air pressure and flow. Shafts are of machined, ground and polished SAE1040 to 1045 Steel. Heavy duty SKF or similar self aligning ball or roller typebearings are used as standard.Features¨ Streamlined inlet¨ Flanged outlet¨ Welded steel housing¨ Oversized shaft and bearingsTestingRated fan performance has been tested in accordance with therequirements of AMCA Standard 210. Rated fan sound performance hasbeen tested in accordance with the requirements of AMCA Standard 300.Selection and SpecificationFor the full range of Chicago fans and blowers to suit all applications, <strong>Fans</strong><strong>Direct</strong> offers a specialised software package, Chicago Select, which can be<strong>download</strong>ed instantly through our website, www.fansdirect.com.au. Forspecialist technical advice contact the Chicago Blower Division of <strong>Fans</strong><strong>Direct</strong> - Australia 1300 733 833 NZ 0800 100 32634 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


AF/BC - Custom Heavy Duty <strong>Fans</strong>productAF/BC - Custom Heavy Duty <strong>Fans</strong>Impeller mmOn applicationDutyup to required m 3 /sup to required kPaup to required °CapplicationClean air - Dirty and /or corrosive air applicationsDescriptionThe two most important criteria when specifying a custom heavy-duty fanare efficiency and reliability. Air handling systems are increasing in complexitywith the addition of more restrictive emission controls and air cleaningdevices. While the results have been a cleaner environment, system pressurerequirements have risen significantly. As these requirements increase, greaterlevels of energy are needed to force the air or gas through the system.Operating efficiency of the fan has become much more critical. Every dollarsaved on the purchase of a less efficient fan will be consumed in additionaloperating costs. Maximum fan efficiency will not only have a positive impacton the bottom line, it will have a positive impact on the environment. Greaterfan efficiency results in lower power requirements and fewer naturalresources consumed. Efficiency also influences sound levels. A more efficientfan will run quieter than the less efficient fan. The quieter fan will need lesssound insulating materials, or none at all.ApplicationTo cover the widest range of system requirements, we offer a full family ofaerofoil and backward curved fan designs with overlapping performanceenvelopes. To maintain high efficiency and maximum economy, the system’spressure and flow requirements are matched to one of eleven impellerdesigns with varying rotor widths and diameters. The selected fan is then sizedto exact duty requirements. Impellers are available with either, proven hollowaerofoil blades for clean air, or solid backward curved or backward inclinedblades for dusty, dirty applications. With eleven rotor designs, custom sizingand duty matching blades, <strong>Fans</strong> <strong>Direct</strong> will build the fan to meet exactsystem performance specifications.Features¨ All aerofoil and backward inclined impellers are available as DWDI¨ Individually computer engineered and sized¨ Precise performance at maximum efficiency¨ Reliability through quality assuranceTestingRated fan performance has been tested in accordance with therequirements of AMCA Standard 210. Rated fan sound performance hasbeen tested in accordance with the requirements of AMCA Standard 300.Selection and SpecificationFor specialist technical advice contact the Chicago Blower Division of <strong>Fans</strong><strong>Direct</strong> - Australia 1300 733 833 NZ 0800 100 326© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 35


D53 - Single Stage Pressure BlowerFANSCATALOGUEproductD53 - Single Stage Pressure BlowerOutlet mm100 - 350Dutyup to, 8.5 m 3 /sup to, 23 kPaup to, 450° CapplicationClean air high pressure applicationsDescriptionAn extremely wide performance range is provided by 54 impeller andhousing combinations. The Design 53 is available in four arrangements andeight discharge positions to suit almost every application. In addition to directdrive, the Design 53 is also available in belt drive arrangements.ApplicationDesign 53 single stage pressure blower is designed for combustion air, fluidbed aeration, cooling, drying and many process system applications. It is alsocommonly used in pneumatic conveying systems.ConstructionImpellers are fully welded to deliver structural integrity and operationallongevity. Precision impeller balancing assures dependable vibration freeoperation. Impeller housings are of continuously seam welded steelconstruction machined, ground and polished SAE 1040 to 1045 Steel. Heavyduty SKF or similar self aligning ball or roller type bearings are used asstandard.Features¨ Efficient "constant velocity" impeller design provides smooth stable airflow¨ Wide performance range afforded by 54 impeller and housingcombinations¨ Heavy gauge housings and pedestals rigidly braced for strenuous duty¨ Available in four arrangements and eight discharge positions; beltdrive or direct driveTestingRated fan performance has been tested in accordance with therequirements of AMCA Standard 210. Rated fan sound performance hasbeen tested in accordance with the requirements of AMCA Standard 300.Selection and SpecificationFor the full range of Chicago fans and blowers to suit all applications, <strong>Fans</strong><strong>Direct</strong> offers a specialised software package, Chicago Select, which can be<strong>download</strong>ed instantly through our website, www.fansdirect.com.au. Forspecialist technical advice contact the Chicago Blower Division of <strong>Fans</strong><strong>Direct</strong> - Australia 1300 733 833 NZ 0800 100 32636 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


D2300 - Pressure Air <strong>Fans</strong>productD2300 Pressure Air <strong>Fans</strong>Impeller mm500 - 2500Dutyup to, 210 m 3 /sup to, 27 kPaup to, 550° CapplicationClean air - Dirty and /or corrosive air - high pressure applicationsDescriptionTo meet specific applications, Pressure Air (PA) fans can be built with stainlesssteel or alloy construction. Split housings facilitate impeller removal withoutdisturbing connecting ductwork. Integral inlet boxes, pre-spun inlet dampersand opposed-blade outlet dampers all control air flow. Belt guards and shaftcoolers are also common options, in addition to the various housing andimpeller liners. Our engineers are available to design and build the pressurefan that meets your exact requirements.ApplicationPA <strong>Fans</strong> are at work in many diverse applications here in Australia and inlocations throughout the world. Clean air applications include combustionair, air drying, primary air ejectors, and product cooling. This fan can alsohandle pneumatic conveying systems. The PA fan is ideal for corrosiveexhaust, air pollution systems and chemical processing. By adding ceramictile or chromium carbide impeller and housing liners, PA fans easily handleabrasive materials. In particular, fans with ceramic tile liners are extremelyeffective in pulverized coal applications, handling up to 8750 grains percubic metre of air. For corrosive gases, a stainless steel impeller and housingis available, or a lower cost rubber-lined, mild steel housing will often fulfil therequirements.Features¨ Designed to meet specific customer performance and mechanicalrequirements¨ Available in arrangements 1, 3, 4, 7, 8, and 9¨ All housings are standard with welded construction throughout¨ <strong>Fans</strong> are equipped with flanged inlet and outlet, access door, drain,shaft seal, guards for shaft, bearing and couplings, and extended lubelinesTestingRated fan performance has been tested in accordance with therequirements of AMCA Standard 210. Rated fan sound performance hasbeen tested in accordance with the requirements of AMCA Standard 300.Selection and SpecificationFor the full range of Chicago fans and blowers to suit all applications, <strong>Fans</strong><strong>Direct</strong> offers a specialised software package, Chicago Select, which can be<strong>download</strong>ed instantly through our website, www.fansdirect.com.au. Forspecialist technical advice contact the Chicago Blower Division of <strong>Fans</strong><strong>Direct</strong> - Australia 1300 733 833 NZ 0800 100 326© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 37


FANSCATALOGUEFRP - Centrifugal <strong>Fans</strong>productFRP - Centrifugal <strong>Fans</strong>Impeller mm225 - 1800Dutyup to, 49 m 3 /sup to, 7 kPaup to, 85° CapplicationHighly Corrosive applicationsDescriptionThe versatile Fibreglass Reinforced Plastic (FRP) fan is offered in three impellerdesigns and in sizes to fit all commonly used duct diameters. Whilearrangement 9 is considered standard, arrangements 1,4, and 8 areavailable on most series and sizes to better suit the specific installation. Inaddition to a multitude of standard models, custom fans can be fabricatedto meet unique requirements, including alternate plastic resin formulationsand exotic metal high-pressure impellers.ApplicationFrom steel mills to chemical processing to emissions control, industrial airmoving and exhausting systems must withstand a growing variety of severecorrosives. Fibreglass Reinforced Plastic (FRP) fans are built to handle theseharsh fumes, vapours, and gases. This fibreglass polyester composition is alsoimpervious to extreme outside environments. Exterior steel components areprotected by a special vinyl phenolic coating.Features¨ Centrifugal fans offer backward inclined, radial blade and radial tipimpeller designs¨ Smooth FRP resin reduces friction and minimizes solids build-up¨ Fibreglass polyester composition impervious to extreme outsideenvironmentsTestingRated fan performance has been tested in accordance with therequirements of AMCA Standard 210. Rated fan sound performance hasbeen tested in accordance with the requirements of AMCA Standard 300.Selection and SpecificationFor the full range of Chicago fans and blowers to suit all applications, <strong>Fans</strong><strong>Direct</strong> offers a specialised software package, Chicago Select, which can be<strong>download</strong>ed instantly through our website, www.fansdirect.com.au. Forspecialist technical advice contact the Chicago Blower Division of <strong>Fans</strong><strong>Direct</strong> - Australia 1300 733 833 NZ 0800 100 32638 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


FRP - Tube Axial <strong>Fans</strong>productFRP - Tube Axial <strong>Fans</strong>Impeller mm150 - 1500Dutyup to, 32 m 3 /sup to, 0.75 kPaup to, 85° CapplicationHighly Corrosive applicationsDescriptionThis versatile FRP tube axial fan is offered in belt or direct drive with sizes to fitall commonly used duct diameters. While belt driven, arrangement 9, isconsidered standard, direct drive, arrangement 4, is available on most sizesto better suit the specific installation. In addition to a multitude of standardmodels, custom Chicago fans can be fabricated to meet uniquerequirements, including alternate plastic resin formulations and exotic metalhigh-pressure impellers.ApplicationFrom steel mills to chemical processing to emissions control, industrial airmoving and exhausting systems must withstand a growing variety of severecorrosives. Fibreglass Reinforced Plastic (FRP) fans are built to handle theseharsh fumes, vapours, and gases. This fibreglass polyester composition is alsoimpervious to extreme outside environments. Exterior steel components areprotected by a special vinyl phenolic coating.Features¨ Axial fans offer direct drive and belt drive¨ Smooth FRP resin reduces friction and minimizes solids build-up¨ Fibreglass polyester composition impervious to extreme outsideenvironmentsTestingRated fan performance has been tested in accordance with therequirements of AMCA Standard 210. Rated fan sound performance hasbeen tested in accordance with the requirements of AMCA Standard 300.Selection and SpecificationFor the full range of Chicago fans and blowers to suit all applications, <strong>Fans</strong><strong>Direct</strong> offers a specialised software package, Chicago Select, which can be<strong>download</strong>ed instantly through our website, www.fansdirect.com.au. Forspecialist technical advice contact the Chicago Blower Division of <strong>Fans</strong><strong>Direct</strong> - Australia 1300 733 833 NZ 0800 100 326© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 39


D47 - Adjustable Pitch Vane AxialFANSCATALOGUEproductD47 - Adjustable Pitch Vane AxialImpeller mm400 - 2000Dutyup to, 117 m 3 /sup to, 3.7 kPaup to, 65° CapplicationClean Air applicationsDescriptionDesign 47 Vane Axial Adjustable Pitch <strong>Fans</strong> are used in applications wheredemands vary with system or seasonal change. Blade pitch is manually set toincrease or decrease performance. Blades are easily adjustable externally atthe hub. Available in compact direct drive models.ConstructionFan cases are fabricated from heavy gauge sheet steel with roll formedflanges on inlet and outlet. Cases include not less than 9 stationary guidevanes. Impeller blades and hubs are of pressure die cast A356-T51aluminiumalloy. Blades are of aerofoil design shaped for maximum efficiency andtwisted from hub to tip to obtain equal air distribution along the blade.Features¨ Vary volume and pressure by manually resetting blade angle¨ Stable air flow over entire performance range¨ Compact direct drive configuration¨ Horizontal or vertical installation¨ High Efficiency aerofoil bladed impeller¨ Efficiencies over 80%¨ Rugged industrial strength construction¨ AMCA Certified for air and sound performanceTestingRated fan performance has been tested in accordance with therequirements of AMCA Standard 210. Rated fan sound performance hasbeen tested in accordance with the requirements of AMCA Standard 300.Selection and SpecificationFor the full range of Chicago fans and blowers to suit all applications, <strong>Fans</strong><strong>Direct</strong> offers a specialised software package, Chicago Select, which can be<strong>download</strong>ed instantly through our website, www.fansdirect.com.au. Forspecialist technical advice contact the Chicago Blower Division of <strong>Fans</strong><strong>Direct</strong> - Australia 1300 733 833 NZ 0800 100 32640 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 41


FANSCATALOGUELight Commercial andResidential Ventilation42 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


MFP - MixJet Series inline mixed flow44MFP - Kit Series 50SBD - low profile centrifugal52ICP - FloMaster Series inline centrifugal54ICM - TurboMax Series inline centrifugal56K/KV - centrifugal duct and wall fans58KS Series - inline axial60AxJet Series - light duty axial61AxJet AXP150 - mini vane-axial62CEA - ceiling extractor axial63AxJet Series AXC150 ceiling and wall axial 64CEC - ceiling extractor centrifugal65Derby Ventilator 66GAW Series - wall and window axial 67RPA Series - ring plate axial 68RCR Series - roof centrifugal 70Pedestal and wall fans 71CEL - ceiling circulator 72ACC - air circulator centrifugal 73© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 43


MFP MixJet Series inline mixed flowFANSCATALOGUEMFP SeriesIn line duct type fans using a mixed flow impeller design with two speedmotors as standard and exceptionally low noise levels. Motor cases unclipfrom duct connections for easy servicing. The ideal solution for mediumdemand ventilation in commercial and residential systems. Suitable for roomto room air transfer and supply or exhaust ventilation.ConstructionThe range is fitted with mixed flow impellers driven by long life motors withsealed for life bearings. Cases are made from injection moulded polymer.FeaturesHigh or Low speed operation.Speed controllable with VA controller (on high fan speed setting only).Can be installed in parallel or series configuration for higher pressures or flows.Easy motor/impeller dismount system.Fits into tight spaces.<strong>Fans</strong> can be mounted at any angleTestingRated fan performance has been tested in accordance with therequirements of ISO 5801. <strong>Fans</strong> sound data has been determined by testingto ISO 3744/3745.Wiring<strong>Fans</strong> are fitted with flex leads and plugs.Suggested SpecificationThe mixed flow type fans shall be of theMFP Series with two speed motorssupplied by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Mixed flow impellers shall be driven bylong life motors with sealed for lifebearings.Cases shall incorporate fast releasemechanisms to permit maintenanceaccess.All fans shall be fully tested inaccordance with the requirements ofISO 5801 for air flow and ISO 3744/3745for sound.Fan Model D D1 L H Weight, kgMFP 100 96 126 246 190 1.50MFP 125 123 136 246 190 1.40MFP 150 148 185 295 250 3.30MFP 200 197 209 296 261 6.50MFP 250 247 256 383 320 7.50MFP 315 310 323 445 408 8.60Fan ModelSpeedMax. FlowL/sdB(A) @ 3mFan SpeedRPMPower,WCurrent,AMotorProtectionSuits DuctDiameter VoltageMFP 100MFP 125MFP 150MFP 200MFP 250MFP 315High 51.9 35 2500 25 0.2Low 40.3 28 2450 15 0.12High 77.8 36 2500 38 0.26Low 61.1 29 2400 28 0.19High 153.3 44 2450 63 0.27Low 129.7 33 2350 40 0.17High 288.9 52 2510 125 0.55Low 230.6 45 2055 90 0.4High 375 55 2690 188 0.92Low 322.2 47 2360 140 0.63High 653 58 2660 330 1.43Low 488 49 1980 225 0.98IPX4 100mm 230IPX4 125mm 230IPX4 150mm 230IPX4 200mm 230IPX4 250mm 230IPX4 300mm* 230* May be used with reducing adapters44 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


MixJet - single installationAncillariesMFP 100MFP 125150150125125100100Pа75HPа75H50L50L252500 10 20 30 40 50 60L/s00 10 20 30 40 50 60 70 80 90L/s350MFP 150350MFP 200300300250250Pа200150100LHPа200150100LH505000 30 60 90 120 150 180L/s00 50 100 150 200 250 300L/sMFP 250MFP 315500700400600500300PаHPа400H200300100L200L10000 100 200 300 400L/s00 100 200 300 400 500 600 700L/s© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 45


FANSCATALOGUEMixJet - parallel installation150MFP 100 Parallel125100Pа75HLo HidB(A)@3M 32 40Watts 42 66Amps .24 .4Max. Flow L/s 80 10450L2500 20 40 60 80 100 120L/sHz 63 125 250 500 1000 2000 4000 8000 TotalInlet L wA 34 28 48 55 57 55 49 36 62Outlet L wA 35 33 51 56 60 52 52 36 63150MFP 125 Parallel125100Pа75HLo HidB(A)@3M 34 41Watts 46 74Amps .38 .52Max. Flow L/s 122 15550L2500 20 40 60 80 100 120 140 160L/sHz 63 125 250 500 1000 2000 4000 8000 TotalInlet L wA 32 29 48 57 58 57 46 39 59Outlet L wA 26 29 33 38 46 40 34 26 46350MFP 150 Parallel300250Lo HidB(A)@3M 39 49Watts 60 120Amps .34 .54Max. Flow L/s 260 307Pа200H150L1005000 40 80 120 160 200 240 280 320L/sHz 63 125 250 500 1000 2000 4000 8000 TotalInlet L wA 44 47 64 66 65 77 59 51 76Outlet L wA 49 48 62 69 69 71 61 51 7446 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


MixJet - parallel installationMFP 200 Parallel350300250Lo HidB(A)@3M 51 57Watts 180 250Amps .8 1.1Max. Flow L/s 461 577Pа200H150L1005000 100 200 300 400 500 600L/sHz 63 125 250 500 1000 2000 4000 8000 TotalInlet L wA 53 56 64 72 73 81 71 60 77Outlet L wA 55 63 64 72 74 76 69 61 80500MFP 250 Parallel400300PаHLo HidB(A)@3M 54 61Watts 250 354Amps 1.1 1.6Max. Flow L/s 617 778200L10000 100 200 300 400 500 600 700 800L/sHz 63 125 250 500 1000 2000 4000 8000 TotalInlet L wA 53 66 69 76 77 79 68 60 84Outlet L wA 58 57 68 76 79 77 69 57 82700MFP 315 Parallel600500Pа400300HLo HidB(A)@3M 55 65Watts 450 660Amps 1.9 2.8Max. Flow L/s 978 1305200L10000 200 400 600 800 1000 1200 1400L/sHz 63 125 250 500 1000 2000 4000 8000 TotalInlet L wA 60 55 69 79 86 85 71 60 87Outlet L wA 62 60 71 83 85 82 69 59 89© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 47


FANSCATALOGUEMixJet - series installation250MFP 100 Series225200175150Lo HidB(A)@3M 32 40Watts 42 66Amps .24 .4Max. Flow L/s 40.3 52Pа 125100HL75502500 10 20 30 40 50 60L/sHz 63 125 250 500 1000 2000 4000 8000 TotalInlet L wA 31 31 48 53 57 55 50 37 63Outlet L wA 32 32 53 56 60 49 50 36 65MFP 125 Series250225200175Lo HidB(A)@3M 34 41Watts 46 74Amps .38 .52Max. Flow L/s 61 78Pа150125H10075L502500 10 20 30 40 50 60 70 80L/sHz 63 125 250 500 1000 2000 4000 8000 TotalInlet L wA 30 30 47 55 56 59 46 39 62Outlet L wA 30 34 49 52 58 55 50 41 63600MFP 150 Series550500450400Pа350300250LHLo HidB(A)@3M 39 49Watts 60 120Amps .34 .54Max. Flow L/s 130 1532001501005000 20 40 60 80 100 120 140 160L/sHz 63 125 250 500 1000 2000 4000 8000 TotalInlet L wA 44 45 63 65 65 74 60 51 77Outlet L wA 46 50 62 67 70 71 62 51 7548 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


MixJet - series installationMFP 200 Series600500Lo HidB(A)@3M 51 57Watts 180 250Amps .8 1.1Max. Flow L/s 230 289Pа400H300L20010000 50 100 150 200 250 300L/sHz 63 125 250 500 1000 2000 4000 8000 TotalInlet L wA 56 53 63 73 74 79 69 61 78Outlet L wA 58 61 65 69 71 75 71 59 78900MFP 250 Series800700600Pа500400HLo HidB(A)@3M 54 61Watts 250 354Amps 1.08 1.58Max. Flow L/s 308 389300L20010000 50 100 150 200 250 300 350 400 450L/sHz 63 125 250 500 1000 2000 4000 8000 TotalInlet L wA 53 64 67 73 79 80 66 58 83Outlet L wA 58 54 66 74 78 76 66 59 801200MFP 315 Series1000800Pа600HLo HidB(A)@3M 55 65Watts 450 660Amps 1.96 2.86Max. Flow L/s 489 653400L20000 100 200 300 400 500 600 700 800L/sHz 63 125 250 500 1000 2000 4000 8000 TotalInlet L wA 58 58 69 79 86 84 72 60 85Outlet L wA 59 63 74 80 84 83 71 60 87© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 49


FANSCATALOGUEMFP - Kit SeriesMFP Kit SeriesThe MFP Kit series takes the class leading performance of the economicalmixed flow fan series and adds the attenuation performance of theLFS - Lightweight Flexible Silencers. All components of the kits have beendesigned to be as light as possible for fast installation and safe handling intight spaces.Construction<strong>Fans</strong> are fitted with mixed flow impellers driven by long life motors with sealedfor life bearings. Cases are made from injection moulded polymer.Silencers are manufactured from spun aluminium (spigots), metallisedpolyester with helical steel support (outer case) and high performanceacoustic lining / absorbing material.FeaturesHi or Lo speed operation with built in two speed switch.Speed controllable with VA controller (on high fan speed setting only).Easy motor/impeller dismount system.Fits into tight spaces.TestingRated fan performance has been tested in accordance with therequirements of ISO 5801. <strong>Fans</strong> sound data has been determined by testingto ISO 3744/3745.Wiring<strong>Fans</strong> are fitted with flex leads and plugs.Note: Kits should be installed with the L-model silencer on the outlet side of the fan or facing thedirection requiring highest attenuation.KitSize A B C D kgMFP150-KIT 150 265 817 817 5.6MFP200-KIT 200 320 818 1218 12.2MFP250-KIT 250 365 861 1261 13.5MFP315-KIT 315 415 1382 1882 19.1Fan Model Speed Max. Flow L/sFan SpeedRPM Power, W Current, AMFP 150MFP 200MFP 250MFP 315High 153.3 2450 63 0.27Low 129.7 2350 40 0.17High 288.9 2510 125 0.55Low 230.6 2055 90 0.4High 375 2690 188 0.92Low 322.2 2360 140 0.63High 653 2660 330 1.43Low 488 1980 225 0.9850 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


350MFP150-KITMFP 150350MFP200-KITMFP 200300300250250Pа200150100LHPа200150100LH505000 30 60 90 120 150 180L/s00 50 100 150 200 250 300L/sMFP250-KITMFP 250MFP315-KITMFP 315500700400600Suggested SpecificationThe installation shall be the MFP-KITSeries manufactured by <strong>Fans</strong> <strong>Direct</strong>Pty Ltd.<strong>Fans</strong> shall be the MFP MixJet Seriessupplied by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd inconjunction with LFS-SeriesLightweight Flexible Silencers.300HPа200L10000 100 200 300 400Pа500400H300200L10000 100 200 300 400 500 600 700L/sL/sKITSpeedMax. FlowL/sSPL dB referred to 10Kit Ave-12 W Type D: ducted inlet/outlet (LW)dB(A) @ 3m 63 125 250 500 1K 2K 4K 8KHi Outlet 26 29 28 39 23 16 18 25 18MFP150-KITHi Inlet 26 25 24 38 21 11 23 25 18Lo Outlet 19 28 27 38 22 15 17 24 17Lo Inlet 19 24 23 37 20 10 22 24 17Hi Outlet 34 45 47 42 41 25 44 45 37MFP200-KITHi Inlet 30 38 37 42 41 16 35 40 37Lo Outlet 24 40 42 37 36 20 39 40 32Lo Inlet 19 33 32 37 36 11 30 35 32Hi Outlet 38 48 46 53 53 43 55 48 41MFP250-KITHi Inlet 36 43 53 49 47 28 49 49 40Lo Outlet 36 45 43 50 50 40 52 45 38Lo Inlet 30 40 50 46 44 25 46 46 37Hi Outlet 43 47 47 52 51 36 55 53 41MFP315-KITHi Inlet 38 43 40 43 35 30 50 47 34Lo Outlet 39 40 40 45 44 29 48 46 34Lo Inlet 35 36 33 36 28 23 43 40 27© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 51


FANSCATALOGUESBD - low profile centrifugalSBD SeriesThe SBD series is a low profile high performance centrifugal fan designed foruse in ducted ventilation systems. Ideal for commercial, residential andapartment ventilation where cavity space is limited. All fans includeintegrated non-return dampers as standard.ConstructionThe range is fitted with backward curved centrifugal impellers driven byexternal rotor motors with sealed for life bearings. Cases are made frominjection moulded polymer.FeaturesWide range of speed control options.Non-return dampers built in.Long spigots for easy duct connection.Fits into tight spaces.<strong>Fans</strong> can be mounted at any angleTestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to AMCA300Wiring<strong>Fans</strong> are fitted with flex leads and plugs.Fan Model A ØB C D E F G kgAll 150 models 360 150 350 205 75 404 140 3All 200 models 380 200 385 255 83 426 148 3.5Fan ModelL/sAve. dB(A)@ 3mRPM Watts AmpsSPL dB referred to 10 -12 W Type D: ducted inlet/outlet (LW)63 125 250 500 1K 2K 4K 8KSBD150-A 120 46 2520 62 0.27 59 65 59 62 62 63 56 43SBD150-A3High 119 46 2520 62 0.27 59 65 59 62 62 63 56 43Med 94 40 1860 56 0.24 61 55 51 54 55 58 46 33Low 72 30 1440 50 0.22 54 48 41 46 45 47 41 29SBD150-A-SC 120 46 2520 62 0.27 59 65 59 62 62 63 56 43SBD200-A 143 45 2460 62 0.27 51 58 58 61 61 59 57 43SBD200-A3High 143 45 2460 62 0.27 51 58 58 61 61 59 57 43Med 101 35 1860 55 0.24 42 51 47 49 50 52 44 29Low 84 27 1440 50 0.22 42 47 38 41 40 46 27 26SBD200-B 182 47 2580 80 0.34 53 54 55 67 62 59 56 43SBD200-B3High 222 50 2580 80 0.34 55 57 58 70 65 62 59 46Med 180 42 1920 60 0.27 48 49 50 62 58 54 51 38Low 150 35 1440 40 0.2 41 43 43 56 51 48 44 32SBD200-B-SC 182 47 2580 80 0.34 53 54 55 67 62 59 56 43SBD200-C 270 54 2700 135 0.6 55 62 77 69 70 68 60 51SBD200-C3High 222 52 2700 135 0.6 56 62 71 68 70 67 59 49Med 159 46 1920 110 0.5 52 57 58 62 63 61 52 41Low 125 39 1440 65 0.4 45 50 50 55 56 54 45 3452 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


SBD - low profile centrifugalAncillaries350SBD150-A & SBD150-A-SC350SBD150-A3300300Pressure (Pa)250200150100Pressure (Pa)250200150100MH5050L00 25 50 75 100 125 150Air Flow (L/s)00 25 50 75 100 125Air Flow (L/s)300SBD200-A300SBD200-A3250250Pressure (Pa)200150100Pressure (Pa)200150100MH5000 25 50 75 100 125 150 175Air Flow (L/s)50L00 25 50 75 100 125 150 175Air Flow (L/s)350SBD200-B400SBD200-B3300350Suggested SpecificationLow profile centrifugal type fans shallbe of the SBD Series manufacturedby <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Backward curved impellers shall bedriven by external rotor motors withsealed for life bearings.The fans shall incorporate lowresistance back-draft dampers fittedwithin the outlet spigot.All fans shall be fully tested inaccordance with the requirementsof DIN 24163 (1998) for air flow andAMCA 300 for sound.Pressure (Pa)Pressure (Pa)2502001501005000 25 50 75 100 125 150 175 200Air Flow (L/s)SBD200-C5004504003503002502001501005000 50 100 150 200 250 300Air Flow (L/s)Pressure (Pa)Pressure (Pa)300250200H150M10050L00 50 100 150 200 250Air Flow (L/s)SBD200-C3500400300H200M100L00 50 100 150 200 250Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 53


ICP - FloMaster Series inline centrifugalFANSCATALOGUEICPThe FloMaster series offers high performance ventilation in medium to highdemand systems. Suitable for a wide range of uses including generalcommercial and domestic ventilation as well as horticulture and hydroponicsConstructionThe range is fitted with backward curved centrifugal impellers driven byexternal rotor motors with sealed for life bearings. Cases are made from injectionmoulded polymer.FeaturesSpeed controllable.<strong>Fans</strong> can be mounted at any angle.Includes mounting brackets.High efficiency balanced impellersTestingRated fan performance has been tested in accordance with therequirements of ISO 5801. <strong>Fans</strong> sound data has been determined by testingto ISO 3744/3745.Wiring<strong>Fans</strong> are fitted with flex leads and plugs.Suggested SpecificationCircular profile centrifugal type fansshall be of the ICP-FloMaster Seriessupplied by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Backward curved impellers shall bedriven by external rotor motors withsealed for life bearings.All fans shall be fully tested inaccordance with the requirements ofISO 5801 for air flow and ISO 3744/3745for sound.Fan Model d D C A B kgICP 100 100 250 230 27 31 2.15ICP 125 123.5 250 220 27 32.5 2.2ICP 150 150 300 286 30 32.5 2.6ICP 200 200 340 276 30 30 4ICP 200Z 200 340 276 30 30 4.3ICP 250 250 340 264 30 30 4.5ICP 315 315 400 276 40 40 5.1ICP 315Z 315 400 276 40 40 5.2Fan Model Max. Flow L/sSound level,dB(A) @ 3mFan SpeedRPMMotorProtection Power, W Current, ASuits DuctDiameterVoltageICP 100 69.4 46 2820 IP44 80 0.34 100mm 240ICP 125 98.6 46 2800 IP44 79 0.34 125mm 240ICP 150 127.8 46 2725 IP44 80 0.35 150mm 240ICP 200 216.7 48 2660 IP44 107 0.47 200mm 240ICP 200Z Hi-Flow 258.3 51 2125 IP44 173 0.76 200mm 240ICP 250 300.0 50 2090 IP44 173 0.76 250mm 240ICP 315 372.2 50 2655 IP44 200 0.88 300mm* 240ICP 315Z Hi-Flow 472.2 53 2590 IP44 310 1.36 300mm* 240* May be used with reducing adapters54 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


ICP - FloMaster Series inline centrifugalAncillariesICP 100ICP 125400400350350300300250250Pa200Pa200150150100100505000 20 40 60 8000 20 40 60 80 100 120L/sL/sICP 150ICP 200300600250500200400Pa150300PaICP 200Z Hi-Flow100200ICP 2005010000 20 40 60 80 100 120 140L/s00 50 100 150 200 250 300L/s500400ICP 250700600500ICP 315300Pa200Pa400300ICP 315Z Hi-Flow200ICP 31510010000 50 100 150 200 250 300 350L/s00 100 200 300 400 500L/s© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 55


ICM - TurboMax Series inline centrifugalFANSCATALOGUEICMThe TurboMax series offers superior performance ventilation in high demandsystems. Suitable for a wide range of uses including general commercial anddomestic ventilation as well as horticulture and hydroponicsConstructionThe range is fitted with backward curved centrifugal impellers driven byexternal rotor motors with sealed for life bearings. Cases are made fromcorrosion protected steel with powder coat finish.FeaturesSpeed controllable.<strong>Fans</strong> can be mounted at any angle.Includes mounting brackets.High efficiency balanced impellers.Robust steel case.TestingRated fan performance has been tested in accordance with therequirements of ISO 5801. <strong>Fans</strong> sound data has been determined by testingto ISO 3744/3745.Wiring<strong>Fans</strong> are fitted with flex leads and plugs.Suggested SpecificationCircular profile steel cased centrifugaltype fans shall be of the ICM-TurboMaxSeries supplied by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Backward curved impellers shall bedriven by external rotor motors withsealed for life bearings.Fan cases shall be powder coatedover anti-corrosion treatment with 10year guarantee against rusting.All fans shall be fully tested inaccordance with the requirements ofISO 5801 for air flow and ISO 3744/3745for sound.Fan Model d D C A B L E kgICM 125 123 254 205 25 25 258 30 3.85ICM 150 149 304 220 25 25 309 30 5.7ICM 200 198 344 240 25 25 350 40 6.05ICM 250 248 344 249 25 30 350 40 7.2ICM 315 315 403 260 30 40 410 40 7.9ICM 315Z Hi-Flow 315 403 260 30 40 410 40 8.1Fan Model Max. Flow L/sSound level,dB(A) @ 3mFan SpeedRPMMotor ProtectionPower, W Current, ASuits DuctDiameterVoltageICM 125 98.6 47 2800 IP44 75 0.33 125mm 240ICM 150 154 47 2705 IP44 98 0.43 150mm 240ICM 200 263.8 48 2375 IP44 154 0.67 200mm 240ICM 200Z Hi-Flow 305.5 51 2780 IP44 193 0.84 200mm 240ICM 250 330 52 2315 IP44 158 0.69 250mm 240ICM 250Z Hi Flow 363 52 2790 IP44 194 0.85 250mm 240ICM 315 389 52 2600 IP44 171 0.77 300mm* 240ICM 315Z Hi-Flow 522 54 2720 IP44 296 1.34 300mm* 240* May be used with reducing adapters56 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


ICM - TurboMax Series inline centrifugalAncillariesICM 125ICM 150350400300350300250250Pa200150Pa200150100100505000 20 40 60 80 100 120L/s00 20 40 60 80 100 120 140 160L/sICM 200ICM 250600600500500400400300PaICM 200Z Hi-Flow300PaICM 250Z Hi-Flow200ICM 200200ICM 25010010000 50 100 150 200 250 300 350L/s00 50 100 150 200 250 300 350 400L/sICM 315800700600500400Pa300ICM 315Z Hi-Flow200100ICM 31500 50 100 150 200 250 300 350 400 450 500 550L/s© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 57


FANSCATALOGUEK/KV centrifugal duct and wall <strong>Fans</strong>K/KVK and KV fans are inline duct mounted and duct connected wall mount fansrespectively. Both products share common performance characteristics andare suitable for installation in medium demand ventilation systems.ConstructionThe range is fitted with backward curved centrifugal impellers driven byexternal rotor motors with sealed for life bearings. Motors are single phase.Cases are fabricated from galvanised sheet steel with folded seems forexcellent air tightness.FeaturesFully speed controllable.High reliability external rotor motors.<strong>Fans</strong> can be mounted at any angle.Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auKSize A B C D E F kgK125XL 125 246 26 - 26 203 4.5K150M 150 286 25 - 25 202 3K150XL 150 336 29 - 26 226 3.9K200M 200 336 30 - 27 205 3.8K200L 200 336 30 - 27 231 4.5K250M 250 336 30 - 27 177 4K250L 250 336 30 - 27 202 5K315M 315 408 32 - 27 220 7K315L 315 408 38 - 27 225 9KVSize A B C D E F kgKV125XL 124 246 26 120 304 334 4.5KV150M 149 286 25 113 344 374 3KV150XL 149 336 29 147 394 425 3.9KV200M 199 336 30 134 394 425 3.8KV200L 199 336 30 158 394 425 4.5KV250M 249 336 30.5 135 394 425 4KV250L 249 336 30.5 159 394 425 5KV315M 314 408 32.5 145 458 489 7KV315L 314 408 37.5 145 458 489 9Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mWeightkgSPL dB referred to 10 -12 W Type D: ducted inlet/outlet (LW)63 125 250 500 1K 2K 4K 8KK/KV125XL 0.27 0.06 40 50 4.5 56 65 68 69 65 61 52 41K/KV150M 0.26 0.06 42 44 3 43 65 64 65 61 59 48 37K/KV150XL 0.46 0.1 43 53 3.9 49 65 72 73 67 63 63 51K/KV200L 0.71 0.16 44 50 4.5 49 68 70 71 65 62 58 50K/KV200M 0.46 0.1 43 51 3.8 47 67 67 72 65 61 59 50K/KV250L 0.7 0.16 44 49 5 59 66 67 68 67 62 55 46K/KV250M 0.45 0.1 43 49 4 45 59 61 65 62 60 62 53K/KV315L 1.39 0.3 39 50 9 55 67 70 71 68 66 63 58K/KV315M 0.89 0.2 43 47 7 37 52 61 67 66 62 58 5558 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


K/KV centrifugal duct and wall fansAncillaries350K/KV Series300Pressure (Pa)250200150150XL10050125XL150M00 50 100 150 200 250Air Flow (L/s)500K/KV Series450400Pressure (Pa)350300250200200L150100200M5000 50 100 150 200 250 300Air Flow (L/s)600K/KV Series500Suggested SpecificationCentrifugal duct type fans shall be ofthe K/KV Series supplied by <strong>Fans</strong><strong>Direct</strong> Pty Ltd.Pressure (Pa)400300200315L315MMotors shall be backward curvedexternal rotor type with sealed for lifebearings. Fan cases shall be ofcorrosion resistant galvanised steel.1000250L250M0 100 200 300 400 500Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 59


FANSCATALOGUEKS Series - inline axialKSThe KS series offers reliable performance in low to medium demand ductedsystems. Ideally suited to air transfer applications and general extract or inputventilation in residential or commercial projects. High quality, durablecomponents make the KS series ideal for horticultural ventilation.ConstructionThe range is fitted with axial impellers driven by external rotor motors withsealed for life bearings. Motors are single phase in two and four pole speeds.Cases are made from roll formed galvanised steel sheet with crimped spigotends for easy duct connection.FeaturesFully speed controllable.Easy duct connection.High reliability external rotor motors.Supplied with three pin plug leads.<strong>Fans</strong> can be mounted at any angleTestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN45635Wiring<strong>Fans</strong> are fitted with a flex lead and plug.Suggested SpecificationAxial duct type fans shall be of theKS Series supplied by <strong>Fans</strong> <strong>Direct</strong> PtyLtd.Motors with integrated impellers shallbe external rotor type with sealed forlife bearings. Fan cases shall be ofcorrosion resistant galvanised steel.All fans shall be fully tested inaccordance with the requirementsof DIN24163 1998 for air flow andDIN45635 for sound.Pressure (Pa)KS Series 2 Pole1801601401201008060300402502001502000 100 200 300 400 500 600 700Air Flow (L/s)Pressure (Pa)KS Series 4 Pole18016014012010080603504030020 20025000 100 200 300 400 500 600 700 800Air Flow (L/s)KSSize A B C D E kg150 146 150 235 161 150 1.5200 200 202 264 250 160 4250 250 257 316 250 188 5300 300 310 370 300 215 6350 350 357 416 300 238 7Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mWeightkgSPL dB referred to 10 -12 W Type D: ducted inlet/outlet (LW)63 125 250 500 1K 2K 4K 8KKS150-2E 0.25 0.05 47 40 1.5 - 54 59 57 55 54 53 45KS200-2E 0.3 0.06 43 48 4 - 55 62 68 64 62 57 50KS200-4E-B 0.3 0.04 23 32 4 - 52 49 52 49 42 35 34KS250-2E-B 0.51 0.12 42 55 5 - 61 71 75 72 66 61 54KS250-4E-B 0.53 0.07 23 40 5 - 58 58 60 57 51 42 34KS300-2E 0.62 0.14 44 59 6 - 63 72 76 76 73 68 62KS300-4E 0.32 0.07 23 43 6 - 62 62 61 60 55 45 37KS350-4E-B 0.62 0.14 23 57 7 - 72 72 75 72 71 68 6160 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


AxJet Series - light duty axialAxJet SeriesA robust axial fan using four pole motors for low demand continuousoperation. An economically priced fan for use in low demand situationswhere continuous operation may be required. Well suited to simple exhaustor supply air tasks where short duct runs and low pressures are called for.ConstructionThe range is fitted with pressed aluminium axial impellers driven by long lifemotors with sealed for life bearings. Cases are made from rolled galvanisedplate and include rubber seals for secure and airtight connections.FeaturesLong life motors with sealed for life bearingsHorizontal or vertical mountingSupplied with steel mounting brackets for secure and quiet operationSupplied with rubber ring seals.TestingRated fan performance has been tested in accordance with therequirements of ISO 5801. Fan sound data has been determined by testing toISO 3744/3745.Wiring<strong>Fans</strong> are fitted with a flex lead and plug.AXM 150 - 315Suggested SpecificationAxial duct type fans shall be of theAxJet Series supplied by <strong>Fans</strong> <strong>Direct</strong>.120100Axial impellers shall be direct drivenby long life motors with sealed forlife bearings. Fan cases shall be ofcorrosion resistant powder coatedsteel.All fans shall be fully tested inaccordance with the requirementsof ISO 5801 for air flow and ISO3744/3745 for sound.Pressure (Pa)8060402003152502001500 100 200 300 400 500Air Flow (L/s)Fan Model D L K Weight, kgAXM 150 161 220 40 1.8AXM 200 207 220 40 2.4AXM 250 261 270 55 3.7AXM 315 318 278 60 4.9* May be used with reducing adaptersFan ModelMax. FlowL/sSound level,dB(A) @ 3mFan SpeedRPMMotorProtection Power, W Current, ASuits DuctDiameterVoltageAXM 150 55.6 33 1300 IPX4 36 0.26 150mm 240AXM 200 112.5 32 1300 IPX4 43 0.28 200mm 240AXM 250 297.2 48 1300 IPX4 68 0.48 250mm 240AXM 315 472.2 54 1300 IPX4 110 0.75 300mm* 240© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 61


AxJet AXP150 - mini vane-axialFANSCATALOGUEAXPThe AXP150 is a small but powerful axial fan incorporating inlet side guidevanes for maximum efficiency and performance. Ideal for use in small scaleducted exhaust applications in bathrooms, toilets, laundries or any situationwhere a small, powerful and quiet duct fan is required.ConstructionThe fan is fitted with a high efficiency impeller matched to a long life motorwith sealed for life bearings. Casing is made from ABS polymer whichincorporates a guide vane motor mount for improved efficiency.FeaturesSpeed controllable.<strong>Fans</strong> can be mounted at any angle.High output, compact design.TestingRated fan performance has been tested in accordance with therequirements of ISO 5801. <strong>Fans</strong> sound data has been determined by testingto ISO 3744/3745.Suggested SpecificationHigh performance Vane-Axial ducttype fans shall be of the AxJet Seriessupplied by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Wiring<strong>Fans</strong> are fitted with a flex lead and plug.Axial impellers shall be direct drivenby long life type motors with sealedfor life bearings. Fan cases shall beof impact resistant ABS polymer.160140AXP 150All fans shall be fully tested inaccordance with the requirementsof ISO 5801for air flow and ISO3744/3745 for sound.Pressure (Pa)1201008060Ancillaries402000 20 40 60 80 100Air Flow (L/s)Fan Model D a l dAXP150 148 105 30 60Fan ModelMax. Flow L/sSound level,dB(A) @ 3mFan SpeedRPMMotorProtection Power, W Current, ASuits DuctDiameterVoltageAXP150 88 42 2400 IP44 36 0.16 150mm 24062 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


CEA - ceiling extractor axialCEAThe CEA series offers reliable performance in low to medium demand ceilingextraction applications. Four pole models generate very low noise levels andcan be run continuously due to the incorporation of high quality, sealed forlife ball bearing motors. The CEA150-2E is an ideal fan for use in toilets andbathrooms where an unobtrusive low profile fan is required.200 & 250ConstructionThe range is fitted with axial impellers driven by long life motors with sealed forlife bearings. Motors are single phase in two and four pole speeds. Cases aremade from formed galvanised steel sheet and/or injection moulded polymer.FeaturesFully speed controllable.Easy duct connection (CEA150-2E only).High reliability motors.Supplied with three pin plug leads.150TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to BS848-2 1985Wiring<strong>Fans</strong> are fitted with a flex lead and plug.Suggested SpecificationSquare grille axial ceiling fans shallbe of the CEA Series manufacturedby <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.90CEA150-2E120CEA- 4 PoleAxial impellers shall be direct drivenby long life motors with sealed forlife bearings. Fan cases and grillesshall be of impact resistant ABSpolymer.All fans shall be fully tested inaccordance with the requirementsof DIN24163 1998 for air flow andBS848-2 1985 for sound.Pressure (Pa)8070605040302010020 40 60 80 100 120Air Flow (L/s)Pressure (Pa)1008060250402002000 50 100 150 200 250Air Flow (L/s)AncillariesCEA150-2ESize A B kg150 146 151 1.5CEA200 & CEA250Size A B kg200 345 150 5250 345 150 5Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mWeightkgSPL dB referred to 10 -12 W Type B (LW)63 125 250 500 1K 2K 4K 8KCEA150-2E 0.25 0.04 46 40 1.5 - 51 52 53 55 56 53 -CEA200-4E 0.2 0.03 22 27 5 - 52 48 46 43 35 32 -CEA250-4E 0.23 0.04 22 30 5 - 55 51 49 46 38 35 -© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 63


AxJet AXC150 - ceiling and wall axialFANSCATALOGUEAXCThe AXC150 is a small but powerful axial fan delivering higher pressures (up to120 Pascals) for use as a ceiling or ‘through wall’ fan with or without ducting.Ideal for exhaust applications in bathrooms, toilets, laundries or any situationwhere a small, powerful and quiet fan is required.ConstructionThe fan is fitted with a high efficiency impeller matched to a long life motorwith sealed for life bearings. Casings are of ABS polymer with LED indicatorlight.Suggested SpecificationHigh performance Wall / Ceiling typefans shall be of the AxJet Seriessupplied by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Axial impellers shall be direct drivenby long life motors with sealed forlife bearings. Fan cases shall be ofimpact resistant ABS polymer.FeaturesSpeed controllable.<strong>Fans</strong> can be mounted at any angle.High output, compact design.Five blade silent impeller.Excellent for use with short run ducting.TestingRated fan performance has been tested in accordance with therequirements of ISO 5801. <strong>Fans</strong> sound data has been determined by testingto ISO 3744/3745.Wiring<strong>Fans</strong> are fitted with a flex lead and plug.All fans shall be fully tested inaccordance with the requirementsof ISO 5801 for air flow and ISO3744/3745 for sound.160140120AXP AXC150AncillariesPressure (Pa)1008060402000 20 40 60 80 100Air Flow (L/s)Fan Model AØ B C DAXC150 150 207 81 25E182Kg0.99Fan ModelMax. Flow L/sSound level,dB(A) @ 3mFan SpeedRPMMotorProtection Power, W Current, ASuits DuctDiameterVoltageAXC150 85 41 2400 IP44 30 0.13 150mm 24064 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


CEC - ceiling extractor centrifugalCECThe CEC is a low profile fan designed for use as a ducted or un-ductedceiling mounted extractor. Ideal for commercial, residential and apartmentventilation where cavity space is limited.ConstructionThe range is fitted with backward curved centrifugal impellers driven byexternal rotor motors with sealed for life bearings. Cases are made frominjection moulded polymer.FeaturesSpeed controllable with VA type controllersThree speed version availableFits into tight spacesLow noise levelsHigh efficiency backward curve impellerSuggested SpecificationDucted ceiling extraction type fansshall be of the CEC Seriesmanufactured by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.<strong>Fans</strong> to incorporate backwardcurved centrifugal impellers drivenby external rotor motors with sealedfor life bearings. Fan cases shall be ofimpact resistant polymer.All fans to be fully tested inaccordance with the requirementsof DIN 24163 1998 for air flow andAMCA 300 for sound.AncillariesTestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to AMCA300WiringRefer to the latest product datasheet for individual model wiring instructions.Datasheets are available from our electronic selection software <strong>Fans</strong>Select<strong>download</strong>able at www.fansdirect.com.auPressure (Pa)25020015010050CEC190-2ELMH00 20 40 60 80 100 120Air Flow (L/s)A B C ØD E F kgCEC190-2E 270 228 228 95 50 140 2Fan Model L/s dB(A)@ 3m RPM Watts AmpsSPL dB referred to 10 -12 W Type B (LW)63 125 250 500 1K 2K 4K 8KCEC190-2E-L 65 40 1440 50 0.22 - 51 55 60 55 54 51 42CEC190-2E-M 85 47 1860 56 0.24 - 55 61 68 61 60 57 48CEC190-2E-H 110 53 2460 80 0.36 - 62 66 73 68 67 64 55CEC190-2E 110 53 2460 80 0.36 - 62 66 73 68 67 64 55© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 65


FANSCATALOGUEDerby VentilatorDerbyThe Derby Ventilator is a high quality ceiling extraction fan for use with orwithout ducting. Ideal for applications including toilets, kitchens andbathrooms where a quiet fan with ducting option is required. All fans includeintegrated non-return dampers as standard.ConstructionThe range is fitted with forward curve centrifugal impellers driven long lifemotors with sealed for life bearings. Cases are made from injection mouldedABS polymer.FeaturesLow noise operationSimple integrated ceiling clip installationIntegrated back draft damperMinimal flow and pressure drop off with up to 9m of ductWiring<strong>Fans</strong> are fitted with flex leads and plugs.Suggested SpecificationHeader box type ceiling fans shall beof the Derby Series supplied by <strong>Fans</strong><strong>Direct</strong> Pty Ltd.250BPT12-24-2160BPT17-33-2(S)Forward curve impellers shall bedriven by long life motors with sealedfor life bearings. Fan cases and grillesshall be of impact resistant ABSpolymer.Pressure (Pa)200150100Pressure (Pa)1401201008060All fans shall be fully tested inaccordance with the requirementsof DIN24163 1998 for air flow andBS848-2 1985 for sound.5000 10 20 30 40 50Air Flow (L/s)402000 20 40 60 80Air Flow (L/s)Fan ModelMax. FlowL/sSound level,dB(A) @ 3mHole cutMotorProtectionStaticPressure. PaImpeller Dia.Suits DuctDiameterVoltageBPT12-24-2 40 32 230 x 230 IP44 50 120mm 100mm 240BPT17-33-2(S) 65 39 282 x 282 IP44 30 170mm 150mm 24066 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


GAW Series wall and window axialGAWThe GAW series is a range of wall or window mount fans for use in bathrooms,laundries, toilets or general exhaust applications. Available in three sizes tosuit small and large rooms. Each model incorporates electromagneticdampers to ensure there are no drafts when the fan is not in operation.ConstructionThe range is fitted with high efficiency axial impellers driven by long life motorswith sealed for life bearings. Cases are injection moulded from ABS polymer.FeaturesSuitable for glass (window) or wall mounting.Positive closure electromagnetic dampers fitted.230 and 300 models can be wired in supply mode.Special NotesFor through wall applications, a length of semi rigid aluminium duct suited tothe thickness of the wall is required to complete installation (not supplied).Note that the 150 model cannot be wired to operate in supply mode.VA500-GAW On/Off, FWD/REV switch suits 230-A and300-A models.WiringRefer to the wiring diagram packaged with the fan or the product datasheetavailable from our electronic selection software <strong>Fans</strong>Select <strong>download</strong>able atwww.fansdirect.com.auSuggested SpecificationWindow / Wall extract or supply typefans shall be of the GAW Seriessupplied by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.908070GAW150-A/230-A/300-A<strong>Fans</strong> to incorporate axial impellersdriven by long life motors with sealedfor life bearings. Fan cases to be ofimpact resistant ABS polymer.All fans to be fully tested inaccordance with the requirementsof ISO 5801for air flow and ISO744/3745 for sound.Pressure (Pa)60504030201003002301500 50 100 150 200 250 300Air Flow (L/s)Through Glass FixingThrough Wall FixingGAWSize A B C D kg Hole Size Ø150 203 105 23 150 1.5 184Ø230 286 125 25 230 3.1 260Ø300 362 145 29 300 5.2 320ØFan Model Current Motor kWShaft Revs /secdB(A)@ 3mType A (SPL @3m (spherical)) 10 -12 Watts63 125 250 500 1K 2K 4K 8KGAW150-A 0.19 0.03 37 38 18 49 54 56 54 50 43 34GAW230-A 0.2 0.04 19 41 40 50 55 57 58 55 49 41GAW300-A 0.32 0.07 17 46 60 64 63 63 63 59 54 45© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 67


FANSCATALOGUERPA Series - ring plate axialRPAThe RPA series is a range of ceiling or wall mount fans featuring external rotormotors and sickle blade impellers for very quiet operation. Ideally suited tocommercial and industrial ventilation applications where an attractivelystyled ring plate type fan is required. The fans have a cylindrical body designfor direct connection to ductwork. <strong>Fans</strong> can be mounted at any angle.ConstructionCases and grille are of powder coated steel. Motor supports are of corrosionprotected steel.MotorsMotor windings incorporate ‘F’ insulation as standard. Motor bearings aremaintenance free sealed for life design. Auto-reset thermal contacts areprovided.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN 45635Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.Suggested SpecificationRing Plate Axial Flow type fans shall beof the RPA Series manufactured by<strong>Fans</strong> <strong>Direct</strong> Pty LtdSickle blade axial impellers shall bedriven by external rotor motors withsealed for life bearings. Cases andgrilles to be of corrosion protectedpowder coat steel.All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.4RPASize A B C D F E G kg200 255 231 202 145 10 162 4 2.5250 306 282 256 145 10 188 4 6300 360 336 310 170 10 215 4 7350 420 395 356 170 10 245 8 9Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mWeightkgSPL dB referred to 10 -12 W Type D: ducted outlet (LW)63 125 250 500 1K 2K 4K 8KRPA200-2E 0.3 0.06 45 49 3 - 55 62 68 64 62 57 51RPA200-4E 0.21 0.03 23 37 2.5 - 57 54 57 54 47 40 39RPA250-2E 0.51 0.115 41 51 3.7 - 56 63 70 68 61 57 50RPA250-4E 0.53 0.069 23 38 3.4 - 55 55 57 54 48 39 36RPA300-2E 0.62 0.14 45 60 4.6 - 64 73 77 77 74 69 63RPA300-4E 0.3 0.068 23 47 4.2 - 66 66 65 64 59 49 40RPA300-6E 0.16 0.035 16 38 4.2 - 57 57 56 55 50 40 31RPA350-4E 0.58 0.13 23 47 4.2 - 73 65 62 61 60 58 50RPA350-6E 0.32 0.073 16 38 4.2 - 64 56 53 52 51 49 4168 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


RPA Series - ring plate axialRPA Series - 2 PolePressure (Pa)1801601401201008060402002503002000 100 200 300 400 500 600 700Air Flow (L/s)RPA Series - 4 Pole120100Pressure (Pa)806040200300350200 2500 200 400 600 800 1000Air Flow (L/s)RPA Series - 6 PolePressure (Pa)504540353025201510530035000 100 200 300 400 500 600 700Air Flow (L/s)Ancillaries© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 69


FANSCATALOGUERCR Series - roof centrifugalRCRThe RCR range of roof mounted fans is designed for ventilation applicationsincluding domestic kitchen hood extraction where lowest possible noise levelsare required. The fans are also suitable for general medium demand ductedventilation systems where low sound levels are a priority.Suggested SpecificationRoof exhaust type fans shall be of theRCR Series manufactured by <strong>Fans</strong><strong>Direct</strong> Pty Ltd.Backward curved impellers shall bedriven by external rotor motors withsealed for life bearings. Fan cases andgrilles shall be of galvanised steel withpowder coat finish.All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow and AMCA300 1996 for sound.ConstructionThe range is fitted with backward curved centrifugal impellers driven byexternal rotor motors with sealed for life bearings. Components are madefrom galvanised steel with powder coat finish.FeaturesLow noise levels.<strong>Fans</strong> are speed controllable with VA type controllers.Three speed motors availableBird screen designAvailable in optional Colorbond colours.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to AMCA 300 1996WiringThree pin plug. Datasheets are available from our electronic selection software<strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auRCR150-ARCR200-B & RCR200-CRCR250-C350500500300250450400350400Pa200150Pa300250200200-CPa3002001005015010050200-B10000 25 50 75 100 125 150L/s00 50 100 150 200 250 300L/s00 50 100 150 200 250 300L/sRCRSize A B(I/D) C kg150 300 150 220 3.2200 400 200 240 5.2250 500 250 260 5.7Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mSound Power Level dB referred to 10 -12 W Type C: ducted inlet, free out (LWi)63 125 250 500 1K 2K 4K 8KRCR150-A 0.36 0.08 40 47 50 64 59 65 61 63 59 50RCR200-B 0.53 0.12 43 48 50 61 63 66 64 61 62 48RCR200-C 0.73 0.16 44 54 55 62 77 69 70 68 60 51RCR250-C 0.73 0.16 44 50 56 57 63 71 65 62 58 4470 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Pedestal and wall fansPedestal and Wall fans - Commercial / IndustrialPedestal and Wall <strong>Fans</strong> are a cost effective and efficient method of rapidlycooling people, machinery and work areas. Suitable for use in domestic andcommercial applications where larger air volumes are required.General Specifications¨ Heavy duty construction featuring high efficiency blades with highquality chrome plated finger guards.¨ Powerful 3 speed, 240 volt / single phase / 50 Hz electric motor.¨ 0-90° controllable oscillation mode and adjustable tilt of15° downwards and 60° upwards (on pedestal model), allows for coolair to be delivered to areas of most need or to broad sweep, covering90° by approximately 15m.¨ Sturdy cast iron base ensures excellent fan stability for the pedestalmodel (base designs may vary)¨ 12 Months Warranty.Range of dutiesUp to 2,600 - 3,300 L/s free air.NoteSupplied in kit form ready for assembly.Fan SpeedMax. FlowL/sSound level,dB(A) @ 3mFan SpeedRPMMotorProtectionPower,WCurrent,AVoltageHigh 3350 68 1375 IPX4 170 0.8 240Medium 3000 59 1265 IPX4 150 0.6 240Low 2600 55 1135 IPX4 130 0.55 240© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 71


FANSCATALOGUECEL - ceiling circulatorCEL140-WHCEL140-SSCEL ceiling circulatorThe CEL ceiling circulator is a high quality cooling fan for use in commercialor domestic applications where a reliable and silent method of creating airmovement is required.At 1400mm diameter, these fans are the largest in their class and can beinstalled internally or in protected exterior locations. Air flow can bereversed for winter air destratification.ConstructionCEL140-WHManufactured from pressed sheet steel with white powder coat finish.Motors are 188mm x 20mm low profile models with sealed for life ballbearings rated for continuous use. Blades are angled at 23 degrees foroptimum air movement with lowest possible sound levels.CEL140-SSOffers the same design and performance as the powder coated version.All external components including motor housing, shaft and hangingcanopy are manufactured from 316 stainless steel. These fans are suitablefor coastal and marine exposed locations.FeaturesThree year warrantySuitable for salt water environments (SS model only)Reversible for Summer or Winter operationQuiet operationHangsure angle canopy for perfect vertical installation23° blade pitch angle for optimum performanceSupplied with three speed wall plate controller900mm and 1800mm extension rods available (with wiring looms included)AccessoriesCEL-EXT90-WCEL-EXT180-WCEL-EXT90-SSCEL-EXT180-SSExtension Rod 900mm White with LoomExtension Rod 1800mm White with LoomExtension Rod 900mm S'Steel with LoomExtension Rod 1800mm S'Steel with LoomFan ModelForwardReverseSpeed RPM Amps Watts L/s RPM Amps WattsCEL140-WHHighMedLow237165750.450.320.17103.545.81317501200980246185930.450.320.17103.34613.3CEL140-SSHighMedLow241169780.450.320.17103.24613.117501200980246185930.450.320.17103.346.213.372 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


ACC - air circulator centrifugalACC Air Circulator CentrifugalThe ACC Air circulator delivers jet style air movement in large open spacessuch as gymnasiums, school halls, factories and warehouses. By combininghigh performance centrifugal fans with optimised case and vent design, theACC Air Circulator is effective in providing comfortable air movement withoutunnecessary turbulence or noise. The fans can be applied to situationsrequiring cooling air movement at floor level over large areas where HVLS(MacroAir) style fans are not suitable due to physical obstructions. Thecompact design of the ACC unit makes it an ideal solution in tight spaces orlong narrow areas such as warehouse aisles. ACC Air Circulators are alsoeffective for destratification applications in cooler weather.ConstructionManufactured from sheet steel with powder coat finish. Motors are externalrotor types with backward curved centrifugal impellers and sealed for lifebearings.FeaturesFully speed controllable.Ideal for cooling or destratification.Provides powerful air movement in restricted spaces.Powder coat finish as standard.Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions. Itis the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.Air velocity characteristicsSuggested SpecificationAir circulator type fans shall be of theACC Series manufactured by <strong>Fans</strong><strong>Direct</strong> Pty Ltd.Backward curve impellers shall bedriven by external rotor motors withsealed for life bearings. Fan cases shallbe of galvanised steel with powdercoat finish.All fans shall be fully run tested inaccordance with the requirements ofthe <strong>Fans</strong> <strong>Direct</strong> ISO 9001 QualitySystem.Fan ModelFull LoadCurrentMotor kW Shaft Revs /sec Thrust dB(A)@ 3m KgACC560-6D 3.5 0.79 16 11N 53 55© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 73


FANSCATALOGUERoof Mounted Centrifugal74 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


CTCT/CB - Roof Mount Centrifugal 76CBVDCVDC/DFC - Small Roof Mount Centrifugal 78DFCMVC - All Metal Vertical DischargeCentrifugal80KMV - Vertical Discharge Centrifugal 82RCD/RCV - Roof Mount Centrifugal84RCDRCVCS - Supply Air Roof Mount Centrifugal 86© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 75


FANSCATALOGUECT/CB Roof Mount CentrifugalproductCT/CB Roof Mount Centrifugaldimensions mmUp to 710poles & duty4 - 6 / up to 4,200 L/sapplicationA general purpose centrifugal range for extract ventilation.CTCBCT/CBThe CT/CB series is a range of larger diameter vertical and horizontaldischarge roof fans than the more compact VDC/DFC series. This series issuitable for higher air flow and pressure systems.ConstructionComponents are made from UV stabilised polymer, corrosion protected steeland fibreglass. All models are fitted with bird mesh as standard. Available inoptional Colorbond colours.MotorsMotor windings incorporate class ‘B’ or ‘F’ insulation as standard. Motorbearings are sealed for life and maintenance free. Auto-reset thermalcontacts are generally provided, either integrally wired or terminated atwiring connection bar.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN 45635Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements of AS/NZS3000:2007 Australian/New Zealand wiring rules.Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mSound Power Level dB referred to 10 -12 W Type C: ducted inlet, free out (LWi)63 125 250 500 1K 2K 4K 8KCB190-A3-H 0.32 0.08 40 42 - 49 56 62 56 56 55 46CB190-A3-M 0.26 0.06 31 37 - 44 52 56 49 51 50 35CB190-A3-L 0.25 0.06 24 30 - 38 46 48 43 47 39 24CB/CT500-4D 2.2 1.2 23 58 71 81 82 77 72 68 64 63CB/CT500-4D-L 1.35 0.78 19 52 65 75 76 71 66 62 58 57CB/CT500-4E 5.7 1.35 23 58 71 82 82 77 73 69 67 63CB/CT500-6D 0.96 0.41 14 47 71 71 72 64 62 55 52 45CB/CT500-6E 2.2 0.45 14 47 57 68 68 63 59 55 53 49CB/CT560-4D 3.4 1.8 22 62 78 90 88 80 75 71 66 64CB/CT560-4D-L 1.8 0.96 16 53 69 81 79 71 66 62 57 55CB/CT560-6D 1.45 0.69 14 48 75 74 72 64 63 58 54 51CB/CT560-6E 3 0.67 13 48 74 74 71 62 61 56 53 49CB/CT630-4D 6.8 3.9 23 66 82 94 92 82 79 75 71 70CB/CT630-4D-L 4.7 2.7 18 65 81 93 91 81 78 74 70 69CB/CT630-6D 2.2 101 15 56 72 84 82 72 69 65 61 60CB/CT710-6D 3.6 1.95 15 58 80 84 85 72 71 67 64 602E=2pole, 1phase. 2D=2 pole, 3phase, 4E=4 pole, 1Phase. 4D=4pole, 3phase. 6E=6pole, 1phase. 6D=6 pole, 3phase. 8D=8pole, 3phase.Ancillaries76 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


CTSize A B C D E kg500 810 650 940 640 80 34560 810 650 940 640 80 46630 940 790 1065 725 100 80710 940 790 1065 725 100 110CBSize A B C D E kg190 380 325 370 250 60 10500/560 810 710 965 557 100 35/40630/710 940 790 1270 710 115 57/73CB190-A3CT/CB 4 Pole3501000Suggested SpecificationRoof Mounted Exhaust type fans shallbe of the CT/CB Series manufacturedby <strong>Fans</strong> <strong>Direct</strong> Pty LtdBackward curved impellers shall bedriven by external rotor motors withsealed for life bearings. <strong>Fans</strong> shall befully weather proof and fabricatedfrom UV resistant ABS polymer.Pa300250200H150M100L5000 50 100 150Volume (L/s)Pa90080070060050040063030056020050010000 1000 2000 3000 4000 5000Volume (L/s)All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow and DIN45635 for sound.350CT/CB 6 Pole600CT/CB 6 Pole300500250400200Pa150100560Pa3002007105050010000 500 1000 1500 2000 2500Volume (L/s)00 1000 2000 3000 4000 5000Volume (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 77


FANSCATALOGUEVDC/DFC Small Roof Mount CentrifugalproductVDC/DFC Small Roof Mount Centrifugaldimensions mmUp to 450poles & duty4 - 8 / up to 1,500 L/sVDCapplicationAn economical small capacity centrifugal range for extract ventilation.DFCVDC/DFCThe VDC/DFC series is a range of small diameter vertical and horizontaldischarge fans for general ventilation applications. Suitable for medium airflow and pressure duct systemsConstructionComponents are made from UV stabilised polymer, corrosion protected steeland fibreglass. All models are fitted with bird mesh as standard. Available inoptional Colorbond colours.MotorsMotor windings incorporate class ‘B’ or ‘F’ insulation as standard. Motorbearings are sealed for life and maintenance free. Auto-reset thermalcontacts are generally provided, either integrally wired or terminated atwiring connection bar.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN 45635Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.Fan ModelFull LoadCurrentMotor kWdB(A)@ 3mSound Power Level dB referred to 10 -12 W Type C: ducted inlet, free out (LWi)63 125 250 500 1K 2K 4K 8KVDC190-2E 0.32 0.07 42 0 49 56 62 56 56 55 46VDC/DFC220-2E 0.34 0.08 55 0 58 67 73 70 65 65 73VDC/DFC220-4E 0.25 0.05 55 0 58 67 73 70 65 65 73VDC/DFC280-4E 0.35 0.08 44 57 61 66 63 59 58 51 45VDC/DFC280-6E 0.35 0.08 37 50 54 60 56 51 50 46 40VDC/DFC310-4D 0.35 0.13 44 68 69 67 63 57 54 58 45VDC/DFC310-4E 0.5 0.12 46 68 73 67 65 59 55 59 47VDC/DFC310-6D 0.27 0.13 38 60 65 59 57 51 47 51 39VDC/DFC310-6E 0.5 0.12 38 60 65 59 57 51 47 51 39VDC/DFC355-4D 0.49 0.27 48 68 73 71 68 61 58 55 49VDC/DFC355-4E 0.97 0.21 48 68 73 71 68 61 58 55 49VDC/DFC355-6D 0.22 0.13 39 59 64 62 59 52 49 46 40VDC/DFC355-6E 0.54 0.12 39 59 64 62 59 52 49 46 40VDC/DFC400-4D 0.88 0.46 52 69 78 75 72 64 61 60 58VDC/DFC400-4E 2.2 0.52 53 70 79 76 73 65 62 61 59VDC/DFC400-6D 0.29 0.14 42 69 69 66 61 57 49 48 36VDC/DFC400-6E 0.8 0.17 45 62 71 68 65 57 54 53 51VDC/DFC400-8D 0.16 0.08 36 63 63 60 55 51 43 42 30VDC/DFC400-8E 0.64 0.12 36 63 63 60 55 51 43 42 30VDC/DFC450-4D 1.3 0.69 54 69 78 78 74 67 64 65 55VDC/DFC450-4E 3.2 0.74 54 69 78 78 74 67 64 65 55VDC/DFC450-6D 0.62 0.24 47 62 71 71 67 60 57 58 48VDC/DFC450-6E 1.5 0.3 46 61 70 70 66 59 56 57 47VDC/DFC450-8D 0.31 0.19 39 54 63 63 59 52 49 50 40VDC/DFC450-8E 0.8 0.15 39 54 63 63 59 52 49 50 402E=2pole, 1phase. 2D=2 pole, 3phase, 4E=4 pole, 1Phase. 4D=4pole, 3phase. 6E=6pole, 1phase. 6D=6 pole, 3phase. 8D=8pole, 3phase.78 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


VDCSize A B C D E kg190/220 265 215 410 250 70 7/8280/310 395 345 515 300 70 10/12355/400 455 355 615 400 70 16/18450 565 465 740 480 70 22DFCSize A B C D E kg220 295 245 350 120 70 4280/310 395 345 500 235 70 5/6355 495 445 635 285 70 11400 455 355 705 390 70 12450 565 465 705 426 70 12Suggested SpecificationRoof Mounted Exhaust type fans shallbe of the VDC/DFC Seriesmanufactured by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Backward curved impellers shall bedriven by external rotor motors withsealed for life bearings. Fan bases,caps and wind bands shall beweather proof and fabricated fromUV resistant ABS polymer, corrosionprotected steel and/or fibreglass.All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.PaVDC190-2E & VDC/DFC220-2E400350300250200VDC/DFC220-2E150100VDC190-2E5000 50 100 150 200 250 300Volume (L/s)400350300250VDC/DFC 4 PolePaVDC/DFC220-4E1009080706050VDC/DFC220-4E4030201000 50 100 150Volume (L/s)500450400350300VDC/DFC 4 PoleAncillariesPa20015010050280310355Pa2502001501005040045000 200 400 600 800 1000Volume (L/s)00 500 1000 1500 2000Volume (L/s)250VDC/DFC 6 Pole250VDC/DFC 6 Pole200200150150Pa100355Pa100450502803105040000 100 200 300 400 500 600Volume (L/s)00 200 400 600 800 1000Volume (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 79


MVC All Metal Vertical Discharge CentrifugalFANSCATALOGUEproductMVC All Metal Vertical Discharge Centrifugaldimensions mm315 - 710poles & duty4 - 6 / up to 3,700 L/sapplicationA robust centrifugal range ideal for kitchen extract ventilation.MVC SeriesThe MVC series is a range of high performance all metal fans for use inkitchen exhaust and general ventilation applications. Wind bands havebeen designed to allow easy cleaning of internal surfaces.ConstructionBase and windband are fabricated from galvanised steel in compliance withAS/NZS1668.1:1998 for kitchen exhaust systems. The impeller and motorassembly is supported by a robust galvanised steel frame for long, troublefree service.FeaturesHigh velocity vertical discharge.All steel construction.Easy access for cleaning grease / contaminants from internal surfaces.<strong>Fans</strong> can be mounted at angles up to 30 º.Patented weather shield design for maximised vertical discharge.Available in bushfire code compliant versions.Available in optional Colorbond colours.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN 45635Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is a condition of our warranty that all equipment supplied is installedaccording to the requirements of AS/NZS3000:2007.MVCSize A B C D E kg630/710 805 700 810 795 80 110500/560 680 580 685 685 80 53400/450 555 460 560 555 80 33315/355 505 400 510 505 80 25Fan ModelFull LoadCurrentMotor kW Shaft Revs /sec80 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326dB(A)@ 3mSound Power Level dB referred to 10 -12 W Type C: ducted inlet, free out (LWi)63 125 250 500 1K 2K 4K 8KMVC315-4D 0.27 0.13 23 44 68 69 67 63 57 54 58 45MVC315-4E 0.9 0.17 22 46 68 73 67 65 59 55 59 47MVC355-4D 0.49 0.27 22 48 68 73 71 68 61 58 55 49MVC355-6D 0.1 0.09 18 39 59 64 62 59 52 49 46 40MVC400-4D 1.41 0.52 24 52 69 78 75 72 64 61 60 58MVC400-6D 0.7 0.39 21 42 69 69 66 61 57 49 48 36MVC400-6E 0.8 0.17 15 45 62 71 68 65 57 54 53 51MVC450-4D 1.3 0.69 20 54 69 78 78 74 67 64 65 55MVC450-6D 0.75 0.29 16 47 62 71 71 67 60 57 58 48MVC450-6E 1.42 0.3 16 46 61 70 70 66 59 56 57 47MVC500-4D 3 1.41 23 58 71 81 82 77 72 68 64 63MVC500-4E 5.2 1.43 23 58 71 82 82 77 73 69 67 63MVC500-6D 1.1 0.48 16 47 71 71 72 64 62 55 52 45MVC560-4D 5.8 2.5 23 62 78 90 88 80 75 71 66 64MVC560-6D 1.7 0.78 15 48 75 74 72 64 63 58 54 51MVC630-4D 6.8 3.9 22 66 82 94 92 82 79 75 71 70MVC630-6D 2.8 1.31 15 56 72 84 82 72 69 65 61 60MVC710-6D 3.6 1.95 15 58 80 84 85 72 71 67 64 60MVC710-8D 2.1 1.2 12 51 73 77 78 65 64 60 57 532E=2pole, 1phase. 2D=2 pole, 3phase, 4E=4 pole, 1Phase. 4D=4pole, 3phase. 6E=6pole, 1phase. 6D=6 pole, 3phase. 8D=8pole, 3phase.


Suggested SpecificationRoof Mounted Exhaust type fans shallbe of the MVC Series manufacturedby <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.600500MVC 4 PoleBackward curved impellers shall bedriven by external rotor motors withsealed for life bearings. Fan bases andwind bands shall be weather proofand fabricated from galvanised sheetsteel.All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.Pressure (Pa)40030045020040031510000 200 400 600 800 1000 1200 1400 1600Air Flow (L/s)1200MVC 4 Pole1000AncillariesPressure (Pa)80060040020050056063000 500 1000 1500 2000 2500 3000 3500 4000Air Flow (L/s)300MVC 6 Pole250Pressure (Pa)2001501005035545050000 250 500 750 1000 1250 1500 1750Air Flow (L/s)600MVC 6 Pole500Pressure (Pa)40030020010056063071000 500 1000 1500 2000 2500 3000 3500 4000Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 81


KMV Vertical Discharge CentrifugalFANSCATALOGUEproductKMV Vertical Discharge Centrifugaldimensions mm315 - 710poles & duty4 - 8 / up to 4,600 L/sapplicationA roof mounted motor out of air stream centrifugal range ideal for kitchenextract and general ventilation.KMV SeriesThe KMV series is a range of high performance all metal fans for use in kitchenexhaust and general ventilation applications. Motors are mounted out of theair stream and wind bands are secured with clip fasteners to allow easyaccess for servicing and cleaning.ConstructionFabricated from powder coated galvanised steel in compliance with AS/NZS1668.1:1998 for kitchen exhaust systems. High performance backwardcurved centrifugal impellers are driven by TEFC motors incorporating sealedfor life bearings. Class F motors are rated to 80°C ambient air temperature.Class H motors are rated to 120°C ambient air temperature. Available inoptional Colorbond colours.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN 45635Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is a condition of our warranty that all equipment supplied is installedaccording to the requirements of AS/NZS3000:2007.KMVSize A B C D E Fkg310 410 310 50 600 355 545 45350/400 500 400 50 690 450 600 50/55450/500/560 720 620 60 915 585 755 75/85/90630/710 810 710 60 1135 655 865 120/150Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mSound Power Level dB referred to 10 -12 W Type C: ducted inlet, free out (LWi)63 125 250 500 1K 2K 4K 8KKMV315-4DD 0.9 0.37 24 47 77 75 69 66 59 55 55 51KMV315-6DD 1 0.37 16 41 67 69 60 60 54 51 46 42KMV355-4DD 0.9 0.37 24 51 75 78 72 71 61 63 59 52KMV355-6DD 1 0.37 16 43 65 69 64 63 58 51 46 44KMV400-4DD 0.9 0.37 24 54 79 81 75 73 66 66 65 58KMV400-6DD 1 0.37 16 45 70 72 67 63 58 55 52 47KMV400-8DD 1.1 0.37 12 38 63 65 60 56 51 48 45 40KMV450-4DD 1.7 0.75 24 57 78 81 77 75 69 69 67 63KMV450-6DD 1.1 0.37 16 47 74 75 68 65 59 58 55 50KMV450-8DD 1.2 0.37 12 40 67 68 61 58 52 51 48 43KMV500-4DD 2.4 1.1 24 60 81 85 81 76 74 74 69 71KMV500-6DD 1 0.37 16 50 74 80 72 66 63 61 58 55KMV500-8DD 1.1 0.37 12 43 67 73 65 59 56 54 51 48KMV560-4DD 4.4 2.2 24 65 86 93 88 80 78 78 73 72KMV560-6DD 1.7 0.55 16 54 78 82 75 70 66 66 62 61KMV560-8DD 1.1 0.37 12 44 70 72 66 60 58 56 55 50KMV630-4DD 7.7 4 24 69 90 97 90 83 83 81 80 75KMV630-6DD 2.6 1.1 16 57 81 85 78 72 71 68 66 65KMV630-8DD 1.7 0.55 12 49 70 75 70 65 64 60 60 56KMV710-6DD 4.8 2.2 16 61 85 90 86 75 73 71 70 68KMV710-8DD 2.1 0.75 12 47 72 75 72 61 61 57 56 534ED=4 pole, 1Phase. 4DD=4pole, 3phase. 6ED=6pole, 1phase. 6DD=6 pole, 3phase. 8DD=8pole, 3phase.82 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Suggested SpecificationRoof Mounted Exhaust type fans shallbe of the KMV Series manufactured by<strong>Fans</strong> <strong>Direct</strong> Pty Ltd.600500KMV - 4 PoleBackward curved impellers shall bedriven by out of air stream TEFC motorswith sealed for life bearings. Fan basesand wind bands with fast release clipfasteners shall be weather proof andfabricated from powder coated sheetsteel.Pressure (Pa)40030020045040010035531500 500 1000 1500 2000Air Flow (L/s)All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.1200KMV - 4Pole1000AncillariesPressure (Pa)80060040020050056063000 1000 2000 3000 4000 5000Air Flow (L/s)700KMV - 6 Pole600Pressure (Pa)500400300710200630100560450 500355 40031500 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Air Flow (L/s)350KMV - 8 Pole300Pressure (Pa)2502001501007106305605040045050000 500 1000 1500 2000 2500 3000 3500 4000Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 83


FANSCATALOGUERCD/RCV Roof Mount CentrifugalproductRCD/RCV Roof Mount Centrifugaldimensions mmUp to 710poles & duty4 - 6 / up to 4,200 L/sapplicationA general purpose centrifugal range for extract ventilation.RCDRCVSuggested SpecificationRoof Centrifugal Exhaust type fansshall be of the RCD or RCV Seriesmanufactured by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Backward curved impellers shall bedriven by external rotor motors withsealed for life bearings. Fan bases,wind bands and caps shall beweather proof and fabricated fromUV resistant ABS polymer.All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.RCD/RCVThe RCD/RCV series supersedes the CT/CB range of larger diameter verticaland horizontal discharge roof fans. This new series incorporates improveddesign features as well as revised base dimensions to allow drop inreplacement of commonly encountered roof fans.ConstructionComponents are made from UV stabilised polymer, corrosion protected steeland fibreglass. All models are fitted with bird mesh as standard. Available inoptional Colorbond colours.MotorsMotor windings incorporate class ‘B’ or ‘F’ insulation as standard. Motorbearings are sealed for life and maintenance free. Auto-reset thermalcontacts are generally provided, either integrally wired or terminated atwiring connection bar.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN 45635Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mSound Power Level dB referred to 10 -12 W Type C: ducted inlet, free out (LWi)63 125 250 500 1K 2K 4K 8KRCD/RCV315-4D 0.27 0.15 23 44 68 69 67 63 57 54 58 45RCD/RCV315-4DL 0.15 0.09 20 40 64 65 63 59 53 50 54 41RCD/RCV315-4E 0.9 0.17 22 46 68 73 67 65 59 55 59 47RCD/RCV315-6E 0.5 0.33 17 38 60 65 59 57 51 47 51 39RCD/RCV355-4D 0.49 0.3 22 48 68 73 71 68 61 58 55 49RCD/RCV355-4E 1.12 0.3 24 48 68 73 71 68 61 58 55 49RCD/RCV355-6D 0.25 0.1 18 39 59 64 62 59 52 49 46 40RCD/RCV355-6E 0.31 0.08 14 39 59 64 62 59 52 49 46 40RCD/RCV400-4D 1.41 0.44 24 52 69 78 75 72 64 61 60 58RCD/RCV400-4E 2.2 0.49 22 53 70 79 76 73 65 62 61 59RCD/RCV400-6D 0.7 0.29 21 42 69 69 66 61 57 49 48 36RCD/RCV400-6E 0.68 0.15 15 45 62 71 68 65 57 54 53 51RCD/RCV450-4D 1.3 0.51 21 54 69 78 78 74 67 64 65 55RCD/RCV450-4DL 0.66 0.36 17 45 60 69 69 65 58 55 56 46RCD/RCV450-4E 3 0.69 21 54 69 78 78 74 67 64 65 55RCD/RCV450-6D 0.75 0.29 16 47 62 71 71 67 60 57 58 48RCD/RCV450-6E 1.42 0.29 16 46 61 70 70 66 59 56 57 47RCD/RCV500-4D 3 4 23 58 71 81 82 77 72 68 64 63RCD/RCV500-4DL 1.35 0.78 19 52 65 75 76 71 66 62 58 57RCD/RCV500-4E 5.7 1.43 23 58 71 82 82 77 73 69 67 63RCD/RCV500-6D 1.1 0.5 15 47 71 71 72 64 62 55 52 45RCD/RCV500-6E 2.34 0.5 15 47 57 68 68 63 59 55 53 49RCD/RCV560-6E 3.5 0.79 16 46 74 74 71 62 61 56 53 49RCD/RCV630-4D 6.8 3.21 23 60 82 94 92 82 79 75 71 70RCD/RCV630-6D 2.8 1.31 15 60 72 84 82 72 69 65 61 60RCD/RCV710-6D 3.6 1.95 15 58 80 84 85 72 71 67 64 6084 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


RCDSize A B C D E Max kg355 500 400 730 415 70 12.4400 500 400 730 425 70 15.6450 720 620 840 480 80 22.5500 720 620 965 530 80 33.5560 720 620 965 540 80 39.0630 810 710 1250 635 80 54.0710 810 710 1250 675 80 71.0RCVSize A B C D E Max kg355 500 400 630 395 70 11.9400 500 400 630 410 70 15.1450 720 620 910 510 80 25.2500 720 620 910 510 80 35.7560 720 620 910 515 80 41.2630 810 710 1135 610 80 62.0710 810 710 1135 650 80 79.0RCD/RCV - 4 PoleRCD/RCV - 4 Pole45012004003501000Pressure (Pa)300250200150355400Pressure (Pa)80060040010050315200450500560630000 200 400 600 800 1000 12000 500 1000 1500 2000 2500 3000 3500 4000Air Flow (L/s)Air Flow (L/s)RCD/RCV - 6 PoleRCD/RCV - 6 Pole160600Pressure (Pa)140120100806040315355Pressure (Pa)50040030020020100450500 56063071000 50 100 150 200 250 300 350 40000 1000 2000 3000 4000 5000Air Flow (L/s)Air Flow (L/s)Ancillaries© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 85


FANSCATALOGUECS Supply Air Roof Mount CentrifugalproductCS Supply Air Roof Mount Centrifugaldimensions mmUp to 560poles & duty2 - 6 / up to 2,300 L/sapplicationAn economical medium capacity centrifugal range for input ventilation.CSThe CS series has been purpose designed for roof mounted supply of air intobuilding ventilation systems. The fans offer quiet and efficient operation witha wide range of sizes and electrical configurations.Suggested SpecificationRoof Centrifugal Supply Air type fansshall be of the CS Series manufacturedby <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Backward curved impellers shall bedriven by external rotor motors withsealed for life bearings. Fan bases,and caps shall be weather proof andfabricated from UV resistant ABSpolymer.All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.ConstructionComponents are made from UV stabilised polymer, corrosion protected steeland fibreglass. All models are fitted with bird mesh as standard. Available inoptional Colorbond colours.MotorsMotor windings incorporate class ‘B’ or ‘F’ insulation as standard. Motorbearings are sealed for life and maintenance free. Auto-reset thermalcontacts are generally provided, either integrally wired or terminated atwiring connection bar.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN 45635Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mSound Power Level dB referred to 10 -12 W Type B: ducted inlet, free out (LWi)63 125 250 500 1K 2K 4K 8KCS190-2E3-H 0.36 0.07 41 49 - 64 68 62 61 62 65 60CS190-2E3-M 0.24 0.06 31 42 - 57 61 55 54 55 58 53CS190-2E3-L 0.22 0.05 24 36 - 51 55 49 48 49 52 47CS220-2E 0.38 0.09 43 55 - 58 67 73 70 65 65 73CS225-2E 0.46 0.11 44 48 - 50 59 66 63 62 60 53CS315-4D 0.27 0.13 23 48 68 73 71 68 61 58 55 49CS315-4D-L 0.15 0.09 20 40 64 65 63 59 53 50 54 41CS315-4E 0.9 0.17 22 48 68 73 71 68 61 58 55 49CS315-6E 0.39 0.08 15 38 60 65 59 57 51 47 51 39CS355-4D 0.49 0.27 22 48 68 73 71 68 61 58 55 49CS355-4D-L 0.32 0.18 18 42 62 67 65 62 55 52 49 43CS355-4E 1.35 0.31 22 48 68 73 71 68 61 58 55 49CS355-6D 0.25 0.1 18 39 59 64 62 59 52 49 46 40CS355-6E 0.54 0.12 18 39 59 64 62 59 52 49 46 40CS400-4D 0.88 0.46 22 52 69 78 75 72 64 61 60 58CS400-4D-L 0.49 0.31 20 47 64 73 70 67 59 56 55 53CS400-4E 2.2 0.52 22 53 70 79 76 73 65 62 61 59CS400-6D 0.29 0.14 15 42 69 69 66 61 57 49 48 36CS400-6E 0.8 0.17 15 45 62 71 68 65 57 54 53 51CS450-4D 1.3 0.69 21 54 69 78 78 74 67 64 65 55CS450-4D-L 0.66 0.36 17 45 60 69 69 65 58 55 56 46CS450-6D 0.62 0.24 15 47 62 71 71 67 60 57 58 48CS500-4D 2.2 1.2 23 58 71 81 82 77 72 68 64 63CS500-4D-L 1.35 0.78 19 52 65 75 76 71 66 62 58 57CS500-4E 5.7 1.35 23 58 71 81 82 77 72 68 64 63CS500-6D 0.96 0.41 14 47 71 71 72 64 62 55 52 45CS560-4D 3.4 1.8 22 62 78 90 88 80 75 71 66 64CS560-4D-L 1.8 0.96 16 53 69 81 79 71 66 62 57 55CS560-6D 1.45 0.69 14 48 75 74 72 64 63 58 54 5186 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


CSSize A B C D E kg190 380 325 430 260 50 4220 380 325 430 260 50 4225 380 325 430 260 50 4315/355 510 440 740 550 90 17/22400 610 500 820 600 95 24450/500/560 810 710 960 800 95 27/35/46CS190-2ECS 2 PoleCS 4 Pole300450450250400350400350200300300Pa15010050LMHPa25020015010050220225Pa2502001501005031535540000 50 100 150Volume (L/s)00 50 100 150 200 250Volume (L/s)00 200 400 600 800 1000Volume (L/s)CS 4 PoleCS 4 Pole (Low Speed)CS 4 Pole (Low Speed)800400600700600350300500500250400Pa400Pa200Pa3003002001004505005601501005031535540020010045050056000 500 1000 1500 2000 250000 200 400 600 800 100000 500 1000 1500 2000Volume (L/s)Volume (L/s)Volume (L/s)CS 6 PoleCS 6 Pole350300250400350300Pa25020020015015010050100560400450 50035550315000 200 400 600 800 10000 500 1000 1500 2000PaVolume (L/s)Volume (L/s)Ancillaries© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 87


FANSCATALOGUERoof Mounted Axial88 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


CVB Roof Mounted Fixed Pitch Axial 90VDVD, DQ/DS Roof Mounted Adjustable PitchAxial94DQ/ DSLD/LSLD/LS, LE Roof Mounted Adjustable PitchAxial98LE© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 89


FANSCATALOGUECVB Roof Mounted Fixed Pitch AxialproductCVB - Roof Mounted Fixed Pitch Axialdimensions mm150 - 710poles & duty2 - 6 / up to 3,100 L/sapplicationA highly competitive general purpose range for extract ventilation.Fan ModelFull LoadCurrentMotor kWSpecificationsBases for all models are of galvanised steel construction. Caps aremanufactured from UV stabilised polymer, fibreglass or powder coatedgalvanised steel. Special materials and finishes are available for hazardousenvironments and special circumstances. Available in optional Colorbondcolours.TestingRated fan performance has been determined by testing to ISO 5801 Pt1(1997) and BS848 Pt1 (1998). Fan sound data has been determined by testingto AMCA 300.ImpellersAerofoil fixed pitch impellers in either pressure die cast aluminium or injectionmoulded glass reinforced polypropylene.MotorsMotors are of TEFC design. Motor windings incorporate class ‘B’ or ‘F’insulation as standard. Motor bearings are sealed for life and maintenancefree. Auto-reset thermal contacts are generally provided, either integrallywired or terminated at wiring connection bar.Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.Shaft Revs /secdB(A)@ 3mWeightkgSPL dB referred to 10 -12 W Type C: ducted inlet, free out (LW)63 125 250 500 1K 2K 4K 8KCVB150-2E 0.25 0.04 46 40 3.5 - 51 52 53 55 56 53 -CVB200-2E 0.48 0.11 37 53 5 - 53 55 61 67 70 68 -CVB200-4E 0.2 0.03 22 27 5 - 52 48 46 43 35 32 -CVB250-2E 1.04 0.24 37 57 5 - 56 65 70 71 73 72 -CVB250-4E 0.23 0.04 22 30 5 - 55 51 49 46 38 35 -CVB300-2E 1.04 0.24 37 60 5 - 68 70 73 74 76 75 -CVB300-4E 0.52 0.07 22 39 5 - 57 57 53 54 56 46 -CVB350-4D 0.45 0.24 23 48 12 - 63 65 64 66 59 56 -CVB350-4E 1.1 0.18 23 48 12 - 63 65 64 66 59 56 -CVB350-6E 0.6 0.07 15 44 12 - 49 49 56 64 55 50 -CVB400-4D 0.45 0.24 22 49 32 - 69 68 65 67 60 57 -CVB400-4E 0.95 0.12 22 49 32 - 69 68 65 67 60 57 -CVB400-6E 0.6 0.07 15 39 32 - 62 61 56 57 49 47 -CVB450-4D 1.3 0.37 22 52 35 - 69 70 70 70 61 58 -CVB450-4E 1.5 0.35 22 52 35 - 69 70 70 70 61 58 -CVB450-6E 1.5 0.35 15 42 35 - 59 66 59 60 51 49 -CVB500-4D 1.3 0.37 22 58 40 64 70 71 74 76 72 67 -CVB500-4E 2.7 0.4 22 58 40 64 70 71 74 76 72 67 -CVB500-6D 1.2 0.37 15 52 40 55 58 66 69 69 67 60 -CVB500-6E 0.6 0.07 15 52 40 55 58 66 69 69 67 60 -CVB560-6D 1.2 0.37 15 55 50 59 62 69 72 72 70 64 -CVB560-6E 2.9 0.37 15 55 50 59 62 69 72 72 70 64 -CVB630-6D 1.2 0.37 15 58 60 64 71 68 73 75 73 66 -CVB630-6E 2.9 0.37 15 58 60 64 71 68 73 75 73 66 -CVB710-6D 1.2 0.37 15 59 70 66 73 70 75 77 73 68 -CVB710-6E 2.9 0.37 15 59 70 66 73 70 75 77 73 68 -2E=2pole, 1phase. 2D=2 pole, 3phase, 4E=4 pole, 1Phase. 4D=4pole, 3phase. 6E=6pole, 1phase. 6D=6 pole, 3phase. 8D=8pole, 3phase.90 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


CVB Roof Mounted Fixed Pitch AxialPressure (Pa)CVB150-2E100908070605040302010025 50 75 100Air Flow (L/s)Pressure (Pa)CVB200-2E140120100806040200100 125 150 175 200 225 250Air Flow (L/s)Suggested SpecificationFixed Pitch Axial Flow Exhaust typefans shall be of the CVB Seriesmanufactured by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.7060CVB200-4E160140CVB250-2EAxial Flow impellers shall be driven byTEFC motors with sealed for lifebearings. Fan bases, and caps shall beweather proof and fabricated fromUV resistant ABS polymer, fibreglassand corrosion protected steel.Pressure (Pa)5040302010Pressure (Pa)12010080604020All fans shall be fully tested inaccordance with the requirements ofISO 5801 Pt 1 (1997) and BS 848 Pt1(1998) for air flow and AMCA 300 forsound.AncillariesPressure (Pa)035 60 85 110Air Flow (L/s)CVB250-4E908070605040302010025 75 125 175 225 275Air Flow (L/s)Pressure (Pa)0325 350 375 400 425 450Air Flow (L/s)CVB300-2E160140120100806040200470 520 570 620Air Flow (L/s)120CVB300-4E90CVB350-4E/4D1008070Pressure (Pa)806040Pressure (Pa)60504030202010050 100 150 200 250 300 350Air Flow (L/s)0325 375 425 475 525 575 625Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 91


CVB Roof Mounted Fixed Pitch AxialFANSCATALOGUEPressure (Pa)CVB350-6E40353025201510535 135 235 335 435 535Air Flow (L/s)Pressure (Pa)CVB400-4E/4D1059585756555453525155460 560 660 760 860 960Air Flow (L/s)65CVB400-6E125CVB450-4E/4D55105Pressure (Pa)453525Pressure (Pa)85654515255375 475 575 675Air Flow (L/s)5775 875 975 1075 1175 1275 1375 1475Air Flow (L/s)65CVB450-6E145CVB500-4D/4E55125Pressure (Pa)453525155475 575 675 775 875 975Air Flow (L/s)Pressure (Pa)105856545255850 1050 1250 1450 1650 1850Air Flow (L/s)Pressure (Pa)CVB500-6E/6D756555453525155750 850 950 1050 1150 1250Air Flow (L/s)Pressure (Pa)CVB560-6E/6D10595857565554535251551450 1550 1650 1750 1850 1950 2050Air Flow (L/s)92 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


CVB Roof Mounted Fixed Pitch AxialPressure (Pa)CVB630-6E/6D10595857565554535251551700 1900 2100 2300 2500 2700Air Flow (L/s)Pressure (Pa)CVB710-6E/6D1451251058565452551900 2100 2300 2500 2700 2900 3100 3300Air Flow (L/s)CVBSize A B C D E F kg150 290 240 430 195 25 - 3200 330 280 430 210 25 - 8250 330 280 430 210 25 - 15300 380 330 430 210 25 - 25350 475 385 550 250 25 75 30400 530 440 550 250 50 100 55450 565 475 700 300 25 150 55500 645 545 700 300 80 150 55560 715 615 900 340 80 150 55630 795 695 900 340 80 150 55710 840 740 900 390 80 150 55© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 93


FANSCATALOGUEVD, DQ/DS Roof Mounted Adjustable Pitch AxialproductVD, DQ, DS - Roof Mounted Adjustable Pitch Axial Flowdimensions mm400 - 1120poles & duty2 - 8 / up to 22,000 L/sVD Vertical Discharge ExhaustDQ Down Discharge AxialDS Supply Air AxialapplicationA highly competitive general purpose range for input or extract ventilation.Smoke spill available in VD models.SpecificationsBases for all models are of galvanised steel construction. Caps, wind bandsand shutter flaps are manufactured from UV stabilised polymer, fibreglass orgalvanised steel. The flap mounting mechanism is designed to prevent waterleaking into the fan. Special materials and finishes are available for hazardousenvironments and special circumstances. Available in optional Colorbondcolours.TestingUnits comply with AS4429 and AS1668 pt1 for Smoke Spill applications (VDOnly). Rated fan performance has been determined by testing to ISO 5801Pt1 (1997) and BS848 Pt1 (1998). Fan sound data has been determined bytesting to AMCA 300.ImpellersAerofoil adjustable pitch impellers are available in a range of materials,including pressure die cast aluminium, injection moulded glass reinforcedpolypropylene (GRP) and nylon. Impellers are balanced to ISO1940 GradeG6.3.MotorsMotors are of TEFC design. Motor enclosure features IP54 protection. Motorwindings incorporate class ‘ F’ insulation as standard although class ‘ H’ isreadily available. Motor bearings are sealed for life and maintenance free.Auto-reset thermal contacts are generally provided, either integrally wired orterminated at wiring connection bar.Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.VDSize A B C D E F kg400 530 440 480 315 50 183 30500 645 545 556 445 80 253 40560 715 615 626 445 80 253 50630 795 695 686 511 80 286 60710 840 740 776 515 80 286 70800 960 810 816 635 80 323 801000 1160 1010 1034 635 80 223 130DQ / DSSize A B C D E F kg400 530 440 710 391 50 183 30500 645 545 820 466 80 253 40560 715 615 820 466 80 253 50630 795 695 960 545 80 286 601000 840 740 1234 585 80 286 701000 960 810 1234 670 80 323 801120 1160 1010 1410 710 80 323 13094 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


VD Envelopes By Ø and Motor SpeedPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performanceenvelopes have been grouped by motor speed for each fan model’s available diameter. Note that scales for all charts arelinear. We strongly recommend that these curves be used as a guide only. For detailed performance capability refer to our fanselection software <strong>Fans</strong>Select available for free <strong>download</strong> at www.fansdirect.com.auVD Vertical Discharge Adjustable Adjustible Pitch - 400mm5004002 PoleVD Vertical Discharge ExhaustSuggested SpecificationAdjustable Pitch Axial Flow Exhaust/Supply type fans shall be of the VD,DQ/DS Series manufactured by <strong>Fans</strong><strong>Direct</strong> Pty Ltd.Axial Flow impellers shall be driven byTEFC motors with sealed for lifebearings. Fan bases, and caps shall beweather proof and fabricated fromUV resistant ABS polymer, fibreglassand corrosion protected steel.All fans shall be fully tested inaccordance with the requirements ofISO 5801 Pt 1 (1997) and BS 848 Pt1(1998) for air flow and AMCA 300 forsound. VD units shall comply with therequirements of AS4429 and AS1668 pt1 for smoke spill applicationsPressure (Pa)Pressure (Pa)3002004 Pole6 Pole1008 Pole00 0.5 1 1.5 2 2.5 3 3.5Air Flow (m3/s)VD Vertical Discharge Adjustable Adjustible Pitch - 500mm6005002 Pole4003004 Pole2006 Pole1008 Pole00 1 2 3 4 5 6Air Flow (m3/s)VD VD Vertical Discharge Adjustable Adjustible Pitch - 560mm8007002 Pole600AncillariesPressure (Pa)5004003002004 Pole6 Pole1008 Pole00 1 2 3 4 5 6 7 8Air Flow (m3/s)800VD Vertical Discharge Adjustable Adjustible Pitch - 630mmPressure (Pa)7006005004003002001002 Pole4 Pole6 Pole8 Pole00 2 4 6 8 10 12Air Flow (m3/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 95


FANSCATALOGUEVD Envelopes By Ø and Motor SpeedPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performanceenvelopes have been grouped by motor speed for each fan model’s available diameter. Note that scales for all charts arelinear. We strongly recommend that these curves be used as a guide only. For detailed performance capability refer to our fanselection software <strong>Fans</strong>Select available for free <strong>download</strong> at www.fansdirect.com.au350VD VD Vertical Discharge Adjustable Adjustible Pitch - 710mm3002504 PoleVD Vertical Discharge ExhaustPressure (Pa)200150100508 Pole6 Pole00 2 4 6 8 10Air Flow (m3/s)Pressure (Pa)VD Vertical Discharge Adjustable Adjustible Pitch - 800mm4504004 Pole3503002502001506 Pole1008 Pole5000 2 4 6 8 10 12 14Air Flow (m3/s)VD VD Vertical Discharge Adjustable Adjustible Pitch - 1000mmPressure (Pa)5004504004 Pole3503002502001506 Pole1008 Pole5000 5 10 15 20 25 30Air Flow (m3/s)96 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


DQ/DS Envelopes By Ø and Motor SpeedPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performanceenvelopes have been grouped by motor speed for each fan model’s available diameter. Note that scales for all charts arelinear. We strongly recommend that these curves be used as a guide only. For detailed performance capability refer to our fanselection software <strong>Fans</strong>Select available for free <strong>download</strong> at www.fansdirect.com.au350DQ/DS DQ/DS Adjustable Axial Pitch - 400mm Axial - 400mmDQ Down Discharge AxialDS Supply Air AxialPressure (Pa)3002 Pole2502001504 Pole1006 Pole508 Pole00 0.5 1 1.5 2 2.5 3 3.5Air Flow (m3/s)Pressure (Pa)40035030025020015010050DQ/DS DQ/DS Adjustable Axial Pitch - 500mm Axial - 500mm2 Pole4 Pole6 Pole8 Pole00 1 2 3 4 5Air Flow (m3/s)600DQ/DS DQ/DS Adjustable Axial Pitch - 560mm Axial - 560mmPressure (Pa)5004003002001002 Pole4 Pole6 Pole8 Pole00 1 2 3 4 5 6 7Air Flow (m3/s)Pressure (Pa)40035030025020015010050DQ/DS Adjustable DQ/DS Axial Pitch - 630mm Axial - 630mm2 Pole4 Pole6 Pole8 Pole00 2 4 6 8 10Air Flow (m3/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 97


LD/LS, LE Roof Mounted Adjustable Pitch AxialFANSCATALOGUEproductLD/LS, LE - Roof Mounted Adjustable Pitch Axial Flowdimensions mm800 - 1500poles & duty2 - 8 / up to 50,000 L/sLD Down Discharge ExhaustLS Supply Air AxialLE Vertical Discharge ExhaustapplicationA highly competitive general purpose range for input or extract ventilation.Smoke spill available in LE models.SpecificationsBases and casings for all models are of hot dipped galvanised steelconstruction. Caps, wind bands and shutter flaps are manufactured from UVstabilised polymer or galvanised steel. The flap mounting mechanism isdesigned to prevent water leaking into the fan. Special materials and finishesare available for hazardous environments and special circumstances. Availablein optional Colorbond colours.TestingUnits comply with AS4429 and approved by BS and AMCA. AS1668 pt1 forSmoke Spill applications. Rated fan performance has been determined bytesting to ISO 5801 Pt1 (1997) and BS848 Pt1 (1998). Fan sound data has beendetermined by testing to AMCA 300.ImpellersAerofoil adjustable pitch impellers are available in a range of materials,including pressure die cast aluminium, injection moulded glass reinforcedpolypropylene (GRP) and nylon. Impellers are balanced to ISO1940 GradeG6.3.MotorsMotors are of TEFC design. Motor enclosure features IP54 protection. Motorwindings incorporate class ‘ F’ insulation as standard although class ‘ H’ isreadily available. Motor bearings are sealed for life and maintenance free.Auto-reset thermal contacts are generally provided, either integrally wired orterminated at wiring connection bar.Smoke SpillLE Series fans have been tested and certified to meet the requirements ofAS4429:1999. The fans comply with requirements of AS/NZS1668.1:1998Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.FeaturesHigh efficiency, low noise adjustable pitch axial impeller.Perfectly matched to medium / high pressure and volume systems.Heavy duty hot dip galvanised steel construction.Bird mesh fitted as standard (LD, LS only).98 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


LD/LS Envelopes By Ø and Motor SpeedPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performanceenvelopes have been grouped by motor speed for each fan model’s available diameter. Note that scales for all charts arelinear. We strongly recommend that these curves be used as a guide only. For detailed performance capability refer to our fanselection software <strong>Fans</strong>Select available for free <strong>download</strong> at www.fansdirect.com.au350LD/LS LD/LS Adjustable Adjustible Pitch Axial - 800mm - 800mmLD Down Discharge ExhaustLS Supply Air AxialSuggested SpecificationAdjustable Pitch Axial Flow Exhaust/Supply type fans shall be of the LD/LS,LE Series manufactured by <strong>Fans</strong> <strong>Direct</strong>Pty Ltd.Axial Flow impellers shall be driven byTEFC motors with sealed for lifebearings. Fan bases, and caps shall beweather proof and fabricated fromUV resistant ABS polymer, fibreglassand corrosion protected steel.All fans shall be fully tested inaccordance with the requirements ofISO 5801 Pt 1 (1997) and BS 848 Pt1(1998) for air flow and AMCA 300 forsound. LE units shall comply with therequirements of AS4429 and AS1668 pt1 for smoke spill applicationsAncillariesPressure (Pa)Pressure (Pa)Pressure (Pa)3002504 Pole2001501006 Pole508 Pole00 2 4 6 8 10 12Air Flow (m3/s)LD/LS LD/LS Adjustable Adjustible Pitch Pitch Axial - - 900mm2001804 Pole160140120100806 Pole60408 Pole2000 2 4 6 8 10 12 14Air Flow (m3/s)LD/LS LD/LS Adjustable Adjustible Pitch Axial - 1000mm - 1000mm2001801604 Pole140120100806 Pole60408 Pole2000 5 10 15 20 25Air Flow (m3/s)400350300LD/LS LD/LS Adjustable Adjustible Pitch Pitch Axial - 1120mm - 1120mm4 PolePressure (Pa)250200150100508 Pole6 Pole00 5 10 15 20 25 30 35Air Flow (m3/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 99


FANSCATALOGUELE, Envelopes By Ø and Motor SpeedPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performanceenvelopes have been grouped by motor speed for each fan model’s available diameter. Note that scales for all charts arelinear. We strongly recommend that these curves be used as a guide only. For detailed performance capability refer to our fanselection software <strong>Fans</strong>Select available for free <strong>download</strong> at www.fansdirect.com.au450LE Adjustable Pitch - 800mmLE Vertical Discharge ExhaustPressure (Pa)4004 Pole3503002502001506 Pole1008 Pole5000 2 4 6 8 10 12 14Air Flow (m3/s)Pressure (Pa)LE Adjustable Pitch - 900mm4504003504 Pole3002502001506 Pole100508 Pole00 5 10 15 20Air Flow (m3/s)Pressure (Pa)LE Adjustable Pitch - 1000mm5004504004 Pole3503002502001506 Pole1008 Pole5000 5 10 15 20 25 30Air Flow (m3/s)700LE Adjustable Pitch - 1120mm6004 PolePressure (Pa)50040030020010006 Pole8 Pole0 5 10 15 20 25 30 35 40Air Flow (m3/s)100 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


LE, Envelopes By Ø and Motor SpeedPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performanceenvelopes have been grouped by motor speed for each fan model’s available diameter. Note that scales for all charts arelinear. We strongly recommend that these curves be used as a guide only. For detailed performance capability refer to our fanselection software <strong>Fans</strong>Select available for free <strong>download</strong> at www.fansdirect.com.au800LE Adjustable Pitch - 1250mm7006004 PoleLE Vertical Discharge ExhaustPressure (Pa)5004003006 Pole2001008 Pole00 10 20 30 40 50 60Air Flow (m3/s)800LE Adjustable Pitch - 1400mm7006004 PolePressure (Pa)5004003002008 Pole6 Pole10000 10 20 30 40 50 60Air Flow (m3/s)700600LE Adjustable Pitch - 1500mm5006 PolePressure (Pa)4003002001008 Pole00 10 20 30 40 50 60Air Flow (m3/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 101


FANSCATALOGUELD/LS, LE DimensionsLD / LSSizeMotor FrameSizeA B C D E F kg800 90 - 100 1070 920 1410 500 80 415 143800 112 - 132 1070 920 1410 500 80 615 183900 90 - 100 1170 102 1410 500 80 615 2031000 90 - 132 1300 1150 1680 530 80 415 2621000 160 - 180 1300 1150 1680 530 80 615 4121120 112 - 132 1420 1270 1680 530 80 615 3191120 160 - 180 1420 1270 1680 530 80 815 469LESizeMotor FrameSizeA B C D E F kg800 90 - 100 1080 930 1050 650 80 415 140800 112 - 132 1080 930 4050 650 80 615 180900 90 - 100 1170 1020 1150 650 80 415 160900 112 - 132 1170 1020 1150 670 80 615 2001000 90 - 132 1300 1150 1250 720 80 415 2501000 160 - 180 1300 1150 1250 720 80 615 4001120 112 - 132 1420 1270 1340 720 80 615 3001120 160 - 180 1420 1270 1340 770 80 815 4501250 112 - 132 1550 1400 1560 770 80 615 3501250 160 - 180 1550 1400 1560 920 80 770 5001400 160 - 180 1750 1550 1700 920 80 615 6001400 200 1750 1550 1700 920 80 815 9001500 160 - 180 1850 1650 1830 920 80 615 8001500 200 1850 1650 1830 920 80 815 1300102 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


ten thingsmost peopledon’t knowabout <strong>Fans</strong> <strong>Direct</strong>In the HVAC industry, a lot of people have heard of<strong>Fans</strong> <strong>Direct</strong>, after all we have been supplying fansand ventilation equipment in Australia and NewZealand for the past 10 years. But not everyoneknows just what we are about so here are 10 reasonswhy you might consider us when you next need tomove air.1. We offer a full range of HVAC fans and accessories totackle even the biggest and most involved projects.2. All of our fan performance data has been producedby testing to internationally recognised standards.3. Every fan we build is run tested and data loggedbefore leaving the factory.4. Our product guarantee starts from the date ofcommissioning not the date of sale.5. To make selecting the right fan as easy as clicking amouse, we have developed class leading software forfree <strong>download</strong>.6. For mining and manufacturing markets we build worldrenowned Chicago Blower heavy industrial fans.7. We are owned by our management team and weemploy staff across Australia and New Zealand toservice contractors, consultants and end users.8. We have become world leaders with High Volume LowSpeed fan installations in partnership with MacroAirUSA.9. Every process in our business is governed by anindependently audited ISO9001 quality system.10. Low overheads mean we can keep the cost of ourproducts competitive while delivering quality that issecond to none.So there it is, <strong>Fans</strong> <strong>Direct</strong> offers the HVAC industry a genuinealternative when it comes to fans, blowers and accessories.Check out our website for a full listing of products, locationsand people.www.fansdirect.com.au 1300 733 833www.fansdirect.co.nz 0800 100 326© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 103


FANSCATALOGUEDuct Mounted Axial104 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


60050040030020010000 5 10 15 2 0700600500400300200100032.521.510.508 Pol e6 Pole10°4 Pol eA ir Flow (m3 /s)15°0 0.5 1 1.5 2 2.5 3 3.5Volume m 3 /s10°15°20°25°0 0.5 1 1.5 2 2.5 3 3.530°35°40°Adjustable Pitch Axial Range Overview 106AX Long Cased - 900mmPressure (Pa)AX LC Envelopes by Ø and Motor Speed 108AX LC Dimensions114Static Pressure, Pa20° 25° 30° 35° 40°AX LC Axial Performance Data by pitchangle116Impeller Power, kWFEF Short Cased Inline Axial 246© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 105


Adjustable Pitch Axial Range OverviewFANSCATALOGUEFeatures¨ Case diameters 315—2000mm¨ Airflow to 75,000 L/s¨ Static pressure to 1,500 Pa¨ Matching attenuators¨ Installation ancillaries¨ Speed control range¨ Heavy gauge galvanised steel¨ High temperature options¨ <strong>Direct</strong> Drive¨ Dual Fan Contra-Rotating¨ Dual Fan - Run & Standby¨ Belt Drive¨ Bifurcated¨ Flame proof options¨ Energy efficient smart controloptions.Suggested SpecificationAdjustable Pitch Axial Flow type ductfans shall be of the AX/AT/AC/AY/AZ/AB Series manufactured by <strong>Fans</strong> <strong>Direct</strong>Pty Ltd.Axial Flow impellers shall be driven byTEFC motors with sealed for lifebearings. Fan cases shall be of heavygauge steel with roll formed or fullywelded flanges. All cases to be hotdip galvanised to AS1650specification.SpecificationsCasings for all models are of hot dipped galvanised steel to AS1650 with rollformed or welded inlet and outlet flanges. Flanges incorporate elongatedbolt holes as standardTestingRated fan performance has been determined by testing to BS848 Pt1 (1998).Fan sound data has been determined by testing to AMCA 300.ImpellersHighly efficient aerofoil adjustable pitch impellers are available in a range ofmaterials, including pressure die cast aluminium, injection moulded glassreinforced polypropylene (GRP) and nylon. Impellers are balanced toISO1940 Grade G6.3. All hubs are pressure die cast aluminium alloy.MotorsMotors are of TEFC design. Motor enclosure features IP54 protection. Motorwindings incorporate class ‘ F’ insulation as standard although class ‘ H’ isreadily available. Motor bearings are sealed for life and maintenance free.Auto-reset thermal contacts are generally provided, either integrally wired orterminated at wiring connection bar.Configurations AvailableAvailable in run and standby, contra-rotating, bifurcated and belt driveconfigurations. Performance data and specifications for these configurationsare available from our electronic selection software, <strong>Fans</strong>Select.Wiring DiagramsRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.ApplicationAll units are suitable for internal or external operation at any installed angle.Smoke SpillAX Series fans have been tested and certified to meet the requirements ofAS4429:1999. The fans comply with requirements of AS/NZS1668.1:1998Data and SelectionRefer to the latest product datasheet for individual model data andspecifications. Datasheets are available from our electronic selectionsoftware <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auAncillariesImpeller blades to be of aerofoilsection manufactured from nylon,GRP or pressure die cast aluminium.All fans shall be fully tested inaccordance with the requirements ofBS 848 Pt1 (1998) for air flow andAMCA 300 for sound.106 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Range OverviewproductAX - Long Cased Adjustable Pitch Axial Flow <strong>Direct</strong> Drivedimensions mm315 - 2000poles & duty2 - 8 / up to 75,000 L/sAX <strong>Direct</strong> DriveapplicationA highly competitive general purpose range for input or extract ventilation.The AX series is an extensive range delivering wide performance capabilities for generalventilation applications. The following pages catalogue overall performanceenvelopes as well as performance by fan diameter, motor speed, hub size and bladecount. Specific selections should be derived from our electronic selection software,<strong>Fans</strong>Select, available for <strong>download</strong> at www.fansdirect.com.auproductAT - Run & Standby Adjustable Pitch Axial Flowdimensions mm315 - 1250poles & duty2 - 8 / up to 23,000 L/sAT Run & StandbyapplicationFor applications where ventilation must be continuously available e.g. smokecontrol pressurisation systems .AT run and standby units operate as a close coupled matched pair of fans.Performance levels are guaranteed with either fan operating. Duties availablecorrespond with those of the standard AX range of direct drive axial flow fans up to1250Ø. Specific selections should be derived from our electronic selection software,<strong>Fans</strong>Select, available for <strong>download</strong> at www.fansdirect.com.auproductAC - Contra-Rotating Adjustable Pitch Axial Flowdimensions mm315 - 1250poles & duty2 - 8 / up to 17,000 L/sAC Contra-RotatingapplicationFor applications requiring higher pressures from a compact fan design.AC contra-rotating units operate as a close coupled matched pair of fans. The designconfiguration delivers higher pressures and can be selected as an alternative to highercost centrifugal fans. Specific selections should be derived from our electronic selectionsoftware, <strong>Fans</strong>Select, available for <strong>download</strong> at www.fansdirect.com.auproductAY/AZ - Belt Drive Adjustable Pitch Axial Flowdimensions mm315 - 2000poles & duty2 - 8 / up to 75,000 L/sapplicationFor motor out of airstream applications.AY/AZ Belt DriveAY/AZ belt drive fans offer the same performance range and characteristics as the AXseries. When selecting these fans allowance should be made for the driveconfiguration. For AY open belt drive, select as per AX series. Where belt guards arespecified (AZ) allow for a pressure loss of 7%. Specific selections should be derived fromour electronic selection software, <strong>Fans</strong>Select, available for <strong>download</strong> atwww.fansdirect.com.au© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 107


FANSCATALOGUEproductAB - Bifurcated Adjustable Pitch Axial Flowdimensions mm315 - 1250poles & duty2 - 6 / up to 23,000 L/sapplicationFor specialised and high temperature motor out of airstream applications.BifurcatedAB bifurcated fans are designed for use with abrasive, toxic and high temperaturegases. Suitable for continuous ambient temperatures of up to 100°C where aluminiumimpeller blades are specified. Higher temperatures may be accommodated. Forselection and specification advice, please contact your nearest <strong>Fans</strong> <strong>Direct</strong> salesoffice.AX LC Envelopes by Ø and Motor SpeedThe performance curves catalogued in the following pages offer a guide tothe duties covered within the AX model range. Performance envelopes havebeen grouped by motor speed for each fan model’s available diameter.Note that scales for all charts are linear. We strongly recommend that thesecurves be used as a guide only. For detailed performance capability refer toour fan selection software <strong>Fans</strong>Select available for free <strong>download</strong> atwww.fansdirect.com.au108 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


AX LC Envelopes by Ø and Motor SpeedPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performance envelopes havebeen grouped by motor speed for each fan model’s available diameter. Note that scales for all charts are linear. We strongly recommendthat these curves be used as a guide only. For detailed performance capability refer to our fan selection software <strong>Fans</strong>Select available for free<strong>download</strong> at www.fansdirect.com.au350AX Long Cased - 315mmPressure (Pa)3002502001501002 Pole504 Pole00 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6Air Air Flow (m3/s)3 600AX Long Cased - 400mmPressure (Pa)5004003002001002 Pole4 Pole6 Pole8 Pole00 0.5 1 1.5 2 2.5 3 3.5Air Flow (m3/s)3 /s)600AX Long Cased - 450mm5002 PolePressure (Pa)4003002001004 Pole00 1 2 3 4 5Air Flow (m3/s)3 /s)700AX Long Cased - 500mmPressure (Pa)6005004003002001002 Pole4 Pole6 Pole8 Pole00 1 2 3 4 5 6Air Flow (m3/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 109


AX LC Envelopes by Ø and Motor SpeedFANSCATALOGUEPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performance envelopes havebeen grouped by motor speed for each fan model’s available diameter. Note that scales for all charts are linear. We strongly recommendthat these curves be used as a guide only. For detailed performance capability refer to our fan selection software <strong>Fans</strong>Select available for free<strong>download</strong> at www.fansdirect.com.auAX Long Cased - 560mmPressure (Pa)10009008002 Pole7006005004004 Pole3006 Pole2008 Pole10000 1 2 3 4 5 6 7 8Air Air Flow (m3/s)AX Long Cased - 630mmPressure (Pa)10009008002 Pole7006005004004 Pole3006 Pole2008 Pole10000 2 4 6 8 10 12Air Air Flow (m3/s)AX Long Cased - 710mm4003503004 PolePressure (Pa)250200150100508 Pole6 Pole00 2 4 6 8 10Air Flow (m3/s)3 AX Long Cased - 800mm500Pressure (Pa)4003002001008 Pole6 Pole4 Pole00 2 4 6 8 10 12 14Air Flow (m3/s)3 110 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


AX LC Envelopes by Ø and Motor SpeedPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performance envelopes havebeen grouped by motor speed for each fan model’s available diameter. Note that scales for all charts are linear. We strongly recommendthat these curves be used as a guide only. For detailed performance capability refer to our fan selection software <strong>Fans</strong>Select available forfree <strong>download</strong> at www.fansdirect.com.au600AX Long Cased - 900mm500Pressure (Pa)4003002006 Pole4 Pole1008 Pole00 5 10 15 20Air Flow (m3/s)600AX Long Cased - 1000mm5004 PolePressure (Pa)4003002006 Pole1008 Pole00 5 10 15 20 25 30AirAirFlowFlow (m3/s)(m 3 /s)900AX Long Cased - 1120mmPressure (Pa)8004 Pole7006005004003006 Pole2008 Pole10000 5 10 15 20 25 30 35 40Air Air Flow Flow (m3/s) (m 3 /s)AX Long Cased - 1250mmPressure (Pa)10009004 Pole8007006005004006 Pole3002008 Pole10000 10 20 30 40 50 60Air Flow (mAir Flow (m3/s)3 /s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 111


AX LC Envelopes by Ø and Motor SpeedFANSCATALOGUEPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performance envelopes havebeen grouped by motor speed for each fan model’s available diameter. Note that scales for all charts are linear. We strongly recommendthat these curves be used as a guide only. For detailed performance capability refer to our fan selection software <strong>Fans</strong>Select available for free<strong>download</strong> at www.fansdirect.com.auAX Long Cased - 1400mmPressure (Pa)10009008004 Pole7006005006 Pole4003002008 Pole10000 10 20 30 40 50 60Air Air Flow (m (m3/s)3 AX Long Cased - 1500mm8007006006 PolePressure (Pa)5004003002001008 Pole00 10 20 30 40 50 60Air Air Flow Flow (m(m3/s)3 900AX Long Cased - 1600mmPressure (Pa)8007006 Pole6005004008 Pole30020010000 10 20 30 40 50 60 70AirAirFlowFlow(m(m3/s)3 /s)AX Long Cased - 1800mm6005006 PolePressure (Pa)4003002008 Pole10000 10 20 30 40 50 60 70 80Air Air Flow Flow (m(m3/s)3 112 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


AX LC Envelopes by Ø and Motor SpeedPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performance envelopes havebeen grouped by motor speed for each fan model’s available diameter. Note that scales for all charts are linear. We strongly recommendthat these curves be used as a guide only. For detailed performance capability refer to our fan selection software <strong>Fans</strong>Select available forfree <strong>download</strong> at www.fansdirect.com.auAX Long Cased - 2000mmPressure (Pa)10009008006 Pole7006005004008 Pole30020010000 10 20 30 40 50 60 70AirAirFlowFlow (m3/s)(m 3 /s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 113


FANSCATALOGUEAX LC DimensionsModel SizeMotor FrameSizeA B C D E F G H J K Weight315 63-71 315 379 400 320 320 8 9.5 356 220 270 27 kg400 63-100 400 464 400 330 320 12 10 438 290 340 56 kg450 63-112 450 514 400 320 320 12 10 488 330 380 58 kg500 71-90 500 564 400 340 320 12 10 541 380 430 65 kg500 100-132 500 564 600 340 520 12 10 541 380 430 124 kg560 71-90 560 644 400 370 320 16 10 605 420 470 80 kg560 100-132 560 644 600 370 520 16 10 605 420 470 139 kg630 71-90 630 714 400 430 320 16 10 674 500 550 82 kg630 100-132 630 714 600 430 520 16 10 674 500 550 142 kg710 71-90 710 794 400 470 320 16 12 765 540 600 87 kg710 100-132 710 794 600 470 520 16 12 765 540 600 147 kg800 80-132 800 884 600 540 520 16 12 865 720 820 149 kg800 160 800 884 800 540 720 16 12 865 720 820 241 kg900 90-132 900 1000 600 600 520 16 12 966 810 910 165 kg900 160-180 900 1000 800 600 720 16 12 966 810 910 296 kg1000 90-132 1000 1100 600 670 520 16 14 1070 910 1010 170 kg1000 160-180 1000 1100 800 670 720 16 14 1070 910 1010 304 kg1000 200 1000 1100 1000 670 870 16 14 1070 910 1010 414 kg1120 100-180 1120 1250 800 750 700 16 14 1185 960 1120 330 kg1120 200-225 1120 1250 1000 750 900 16 14 1185 960 1120 590 kg1250 100-180 1250 1380 800 830 700 16 14 1320 1090 1250 340 kg1250 200-225 1250 1380 1000 830 900 16 14 1320 1090 1250 615 kg1250 250 1250 1380 1150 830 1050 16 14 1320 1090 1250 698 kg1400 160-180 1400 1530 800 940 690 24 14 1480 1240 1400 633 kg1400 200-225 1400 1530 1000 940 890 24 14 1480 1240 1400 633 kg1400 250-280 1400 1530 1150 940 1040 24 14 1480 1240 1400 986 kg1500 160-180 1500 1630 800 1000 690 24 14 1560 1340 1500 653 kg1500 200-225 1500 1630 1000 1000 890 24 14 1560 1340 1500 653 kg1500 250-280 1500 1630 1150 670 1040 24 14 1560 1340 1500 1006 kg1600 132-180 1600 1730 800 1070 690 24 14 1685 1440 1600 558 kg1600 200-225 1600 1730 100 1070 890 24 14 1685 1440 1600 710 kg1600 250-280 1600 1730 1150 1070 1040 24 14 1685 1440 1600 1048 kg1600 315 1600 1730 1300 1070 1190 24 14 1685 1440 1600 1733 kg1800 160-180 1800 1930 800 1125 690 24 14 1890 1640 1800 594 kg1800 200-225 1800 1930 100 1125 890 24 14 1890 1640 1800 751 kg1800 250-280 1800 1930 1150 1125 1040 24 14 1890 1640 1800 1099 kg1800 315 1800 1930 1300 1125 1190 24 14 1890 1640 1800 1784 kg2000 180 2000 2130 800 1250 690 24 14 2080 1840 2000 630 kg2000 200-225 2000 2130 1000 1250 890 24 14 2080 1840 2000 798 kg2000 250-280 2000 2130 1150 1250 1040 24 14 2080 1840 2000 1145 kg2000 315 2000 2130 1300 1250 1190 24 14 2080 1840 2000 1840 kg114 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 115


FANSCATALOGUEAdjustable Pitch Axial Performance DataThe performance curves catalogued in the following pagesoffer a guide to the duties covered by AX and AY (Belt Drive)fans at varying pitch angles.Performance data are grouped according to the followinghierarchy:1. Overall Fan Diameter in mm (smallest to largest).315 - 20002. Motor Speed (highest to lowest)48 rps (2 pole)24 rps (4 pole)16 rps (6 pole)12 rps (8 pole)9.5 rps (10 pole)3. Hub Diameter (smallest to largest)4. Blade Count (lowest to highest)Each graph depicts the grouping of curves by pitch angle forthat fan’s overall diameter, speed, hub size and blade count.Corresponding motor power and sound data are alsoprovided.The data displayed has been determined by thorough producttesting. Rated fan performance has been determined bytesting to BS848 Pt1 (1998). Fan sound data has beendetermined by testing to AMCA 300. Type D installation.Chart scales are linear in all cases to assist with visualcomparisons. We recommend that these curves be used as aguide only. For detailed performance capability refer to ourfan selection software <strong>Fans</strong>Select available for free <strong>download</strong>at www.fansdirect.com.au116 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data315 Ø 48 rpsHub Ø 150Blades 5Hub Ø 150Blades 10600700500600400500400300300Static Pressure (Pa)200100010°15°20°25° 30° 35° 40°Static Pressure (Pa)200100010° 15° 20°25° 30°35° 40°0 0.5 1 1.5Volume (m 3 /s)0 0.5 1 1.5Volume (m 3 /s)10.90.80.740°1.41.2140°Impeller Power, kW0.60.50.40.30.20.1025°15° 20°10°30°35°Impeller Power, kW0.80.60.40.2025°15° 20°10°30°35°0 0.5 1 1.50 0.5 1 1.5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 75 76 77 83 81 76 70 61 6415° 82 80 82 79 79 78 71 62 6320° 82 81 83 79 79 78 72 63 6425° 76 77 85 80 78 76 71 64 6330° 74 74 80 77 75 72 68 63 6035° 79 82 79 81 79 76 71 66 6340° 78 80 77 79 77 74 69 65 61Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 82 81 83 87 80 79 74 66 6715° 76 78 79 88 81 78 72 64 6720° 85 84 83 88 82 81 75 66 6825° 80 81 87 89 82 80 75 68 6930° 75 78 78 84 83 81 78 74 6735° 76 79 79 84 83 81 78 74 6740° 76 79 78 83 82 79 76 73 66Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 117


FANSCATALOGUEAdjustable Pitch Axial Performance Data315 Ø 24 rpsHub Ø 150Blades 5Hub Ø 150Blades 10140180120160140100120801006080Static Pressure (Pa)4020010°15°20°25° 30° 35° 40°Static Pressure (Pa)604020010° 15° 20°25° 30°35° 40°0 0.2 0.4 0.6 0.8Volume (m 3 /s)0 0.2 0.4 0.6 0.8Volume (m 3 /s)0.140.16Impeller Power, kW0.120.10.080.060.040.02025°15° 20°10°30°35°40°Impeller Power, kW0.140.120.10.080.060.040.02010°20°15°25°30°35°40°0 0.2 0.4 0.6 0.80 0.2 0.4 0.6 0.8Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 62 64 63 61 61 60 54 46 4515° 65 67 63 62 62 61 55 46 4620° 66 68 63 63 63 62 56 47 4725° 59 63 65 63 61 59 54 47 4530° 59 62 62 62 60 57 53 48 4435° 60 62 61 63 60 57 52 49 4440° 59 60 57 61 58 54 49 48 42Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 65 64 72 64 64 63 57 49 4915° 68 67 72 65 65 64 58 49 5020° 69 68 72 66 66 65 59 50 5125° 71 70 74 68 68 67 61 52 5330° 72 73 75 73 70 65 59 48 5435° 72 71 75 69 69 68 62 53 5440° 72 71 76 69 69 68 62 53 54Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.118 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data315 Ø 16 rpsHub Ø 150Blades 5Hub Ø 150Blades 10607050604050403030Static Pressure (Pa)2010010°15°20°25° 30° 35° 40°Static Pressure (Pa)2010010° 15° 20°25° 30° 35° 40°0 0.1 0.2 0.3 0.4 0.5Volume (m 3 /s)0 0.1 0.2 0.3 0.4 0.5Volume (m 3 /s)0.0350.045Impeller Power, kW0.030.0250.020.0150.010.005025°15° 20°10°30°35°40°Impeller Power, kW0.040.0350.030.0250.020.0150.010.005025°15° 20°10°30°40°35°0 0.1 0.2 0.3 0.4 0.50 0.1 0.2 0.3 0.4 0.5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 55 52 53 52 51 50 44 36 3615° 58 54 53 52 52 51 45 36 3620° 59 55 53 53 53 52 46 37 3725° 61 57 55 55 55 54 48 39 3930° 62 60 57 60 57 52 46 35 4135° 62 58 56 56 56 55 49 40 4040° 62 58 57 56 56 55 49 40 40Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 55 61 56 55 54 53 47 39 3915° 58 63 56 55 55 54 48 39 3920° 59 64 56 56 56 55 49 40 4025° 61 66 58 58 58 57 51 42 4230° 62 69 60 63 60 55 49 38 4435° 62 67 59 59 59 58 52 43 4340° 62 67 60 59 59 58 52 43 43Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 119


FANSCATALOGUEAdjustable Pitch Axial Performance Data315 Ø 12 rpsHub Ø 150Blades 5Hub Ø 150Blades 10354030352530202520Static Pressure (Pa)15105010°15°20°25° 30° 35° 40°Static Pressure (Pa)15105010° 15° 20°25° 30° 35°40°0 0.1 0.2 0.3 0.4Volume (m 3 /s)0 0.1 0.2 0.3 0.4Volume (m 3 /s)0.0160.02Impeller Power, kW0.0140.0120.010.0080.0060.0040.002025°15° 20°10°30°35°40°Impeller Power, kW0.0180.0160.0140.0120.010.0080.0060.0040.002030°25°15° 20°10°40°35°0 0.1 0.2 0.3 0.40 0.1 0.2 0.3 0.4Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 48 44 46 44 44 43 37 29 2815° 51 47 46 45 45 44 38 29 2920° 52 48 46 46 46 45 39 30 3025° 54 50 48 48 48 47 41 32 3230° 55 53 50 53 50 45 39 28 3435° 55 51 49 49 49 48 42 33 3340° 55 51 50 49 49 48 42 33 33Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 48 53 49 47 47 46 40 32 3115° 51 56 49 48 48 47 41 32 3220° 52 57 49 49 49 48 42 33 3325° 54 59 51 51 51 50 44 35 3530° 55 62 53 56 53 48 42 31 3735° 55 60 52 52 52 51 45 36 3640° 55 60 53 52 52 51 45 36 36Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.120 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 121


FANSCATALOGUEAdjustable Pitch Axial Performance Data400 Ø 48 rpsHub Ø 150Blades 5Hub Ø 150Blades 10700700600600500500400400300300Static Pressure (Pa)200100010° 15° 20° 25° 30°35° 40°Static Pressure (Pa)200100010° 15° 20° 25° 30°35° 40°0 1 2 3 4Volume (m 3 /s)0 1 2 3 4Volume (m 3 /s)332.540°2.540°235°235°Impeller Power, kW1.510.5015°10°25°20°30°Impeller Power, kW1.510.5015°10°25°20°30°0 1 2 3 40 1 2 3 4Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 84 83 88 83 83 82 76 68 6815° 87 86 88 84 84 83 77 68 6920° 88 87 88 85 85 84 78 69 6925° 82 83 91 86 84 82 77 70 6930° 82 82 88 85 83 80 76 71 6735° 83 82 87 86 83 80 75 72 6840° 84 82 85 86 83 79 74 73 67Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 81 82 81 94 87 82 76 67 7215° 81 83 84 93 86 83 77 69 7220° 91 90 88 94 88 87 81 72 7425° 84 85 91 93 86 84 79 72 7230° 85 85 89 93 86 83 79 74 7235° 86 85 88 94 86 83 78 75 7340° 82 85 84 89 88 85 82 79 72Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.122 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data400 Ø 24 rpsHub Ø 150Blades 5Hub Ø 150Blades 1018030016014025012020010080150Static Pressure (Pa)604020010° 15° 20° 25° 30°35° 40°Static Pressure (Pa)10050010° 15° 20°25° 30° 35° 40°0 0.5 1 1.5 2Volume (m 3 /s)0 0.5 1 1.5 2Volume (m 3 /s)Impeller Power, kW0.350.30.250.20.150.10.05015°10°25°20°30°35°40°Impeller Power, kW0.60.50.40.30.20.1010° 15° 20°30°25°40°35°0 0.5 1 1.5 20 0.5 1 1.5 2Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 59 63 58 67 65 60 54 45 4915° 60 65 62 67 65 62 56 48 4920° 63 67 67 69 67 64 59 51 5125° 64 68 70 68 66 64 59 52 5130° 63 66 66 66 64 61 57 52 4835° 63 65 64 66 63 60 55 52 4840° 64 65 62 66 63 59 54 53 47Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 71 70 78 70 70 69 63 55 5515° 74 73 77 71 71 70 64 55 5620° 74 73 78 72 71 70 64 55 5625° 76 75 80 74 73 72 66 57 5830° 71 71 80 74 72 69 65 60 5735° 77 76 81 75 74 73 67 58 5940° 73 71 77 75 72 68 63 62 57Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 123


FANSCATALOGUEAdjustable Pitch Axial Performance Data400 Ø 16 rpsHub Ø 150Blades 5Hub Ø 150Blades 1080120701006050804060Static Pressure (Pa)302010010° 15° 20°25° 30°35°40°Static Pressure (Pa)4020010° 15° 20°25° 30° 35° 40°0 0.5 1 1.5Volume (m 3 /s)0 0.5 1 1.5Volume (m 3 /s)Impeller Power, kW0.10.090.080.070.060.050.040.030.020.01015°10°25°20°30°35°40°Impeller Power, kW0.140.120.10.080.060.040.02010° 15° 20°30°25°40°35°0 0.2 0.4 0.6 0.8 1 1.20 0.2 0.4 0.6 0.8 1 1.2Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 60 58 56 65 63 58 52 43 4615° 60 59 59 64 62 59 53 45 4620° 61 59 62 64 62 59 54 46 4625° 67 62 61 61 61 60 53 44 4530° 60 57 60 60 58 55 51 46 4235° 61 57 59 61 58 55 50 47 4240° 60 55 55 59 56 52 47 46 40Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 60 66 60 68 66 61 55 46 4915° 60 67 63 67 65 62 56 48 4920° 61 67 66 67 65 62 57 49 4925° 67 71 64 64 64 63 56 47 4830° 68 75 65 69 66 61 55 44 5035° 68 72 65 65 65 64 57 48 4940° 68 73 65 65 65 64 58 49 49Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.124 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data400 Ø 12 rpsHub Ø 150Blades 5Hub Ø 150Blades 104570406035305025402030Static Pressure (Pa)15105010°15°20° 25° 30° 35° 40°Static Pressure (Pa)2010010° 15° 20°25° 30° 35° 40°0 0.2 0.4 0.6 0.8Volume (m 3 /s)0 0.2 0.4 0.6 0.8 1Volume (m 3 /s)0.0450.07Impeller Power, kW0.040.0350.030.0250.020.0150.010.005015°10°20°25°30°35°40°Impeller Power, kW0.060.050.040.030.020.01010° 15° 20°25°30°35°40°0 0.2 0.4 0.6 0.80 0.2 0.4 0.6 0.8 1Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 54 50 52 50 49 48 42 34 3415° 56 52 51 51 50 49 43 34 3420° 57 53 52 51 51 50 44 35 3525° 59 55 54 53 53 52 46 37 3730° 60 58 55 59 55 50 44 33 3935° 60 56 55 54 54 53 47 38 3840° 60 56 55 55 54 53 47 38 38Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 54 59 55 53 52 51 45 37 3715° 56 61 54 54 53 52 46 37 3820° 57 62 55 54 54 53 47 38 3825° 59 64 57 56 56 55 49 40 4030° 60 67 58 62 58 53 47 36 4235° 60 65 58 57 57 56 50 41 4140° 60 65 58 58 57 56 50 41 42Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 125


FANSCATALOGUEAdjustable Pitch Axial Performance Data450 Ø 48 rpsHub Ø 150Blades 5Hub Ø 150Blades 10900140080012007006001000500800400600Static Pressure (Pa)300200100010° 15° 20° 25° 30° 35° 40°Static Pressure (Pa)400200010° 15°20°25° 30° 35° 40°0 1 2 4 5Volume (m 3 /s)0 1 2 3 4 5Volume (m 3 /s)4.543.532.535°40°765430°35°40°Impeller Power, kW21.510.5015°10°20°25°30°Impeller Power, kW321010° 15° 20°25°0 1 2 3 4 50 1 2 3 4 5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 86 86 90 86 85 84 78 70 7015° 89 88 90 86 86 85 79 70 7120° 90 89 90 87 87 86 80 71 7125° 92 91 92 89 89 88 82 73 7330° 93 94 94 94 91 86 80 69 7535° 93 92 93 90 90 89 83 74 7440° 93 92 94 90 90 89 83 74 75Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 89 89 90 95 88 87 81 73 7415° 92 91 90 95 89 88 82 73 7520° 93 92 90 96 90 89 83 74 7625° 95 94 92 98 92 91 85 76 7830° 96 97 94 103 94 89 83 72 8135° 96 95 93 99 93 92 86 77 7940° 96 95 94 99 93 92 86 77 79Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.126 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data450 Ø 24 rpsHub Ø 150Blades 5Hub Ø 150Blades 10250350200300250150200100150Static Pressure (Pa)50010° 15° 20° 25° 30° 35° 40°Static Pressure (Pa)10050010° 15°20°25° 30° 35° 40°0 0.5 1 1.5 2 2.5Volume (m 3 /s)0 0.5 1 1.5 2 2.5Volume (m 3 /s)Impeller Power, kW0.60.50.40.30.20.1015°10°20°25°30°35°40°Impeller Power, kW0.80.70.60.50.40.30.20.1015°10°20°25°30°35°40°0 0.5 1 1.5 2 2.50 0.5 1 1.5 2 2.5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 70 72 71 69 69 68 62 54 5315° 73 75 70 70 70 69 63 54 5420° 74 75 71 71 71 70 63 54 5525° 76 77 73 73 73 72 65 56 5730° 77 81 74 78 75 70 64 53 5935° 77 78 74 74 74 73 66 57 5840° 77 79 74 74 74 73 67 58 58Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 73 72 80 72 72 71 65 57 5715° 76 75 79 73 73 72 66 57 5820° 77 75 80 74 74 73 66 57 5925° 79 77 82 76 76 75 68 59 6130° 80 81 83 81 78 73 67 56 6235° 80 78 83 77 77 76 69 60 6240° 80 79 83 77 77 76 70 61 62Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 127


FANSCATALOGUEAdjustable Pitch Axial Performance Data450 Ø 16 rpsHub Ø 150Blades 5Hub Ø 150Blades 109014080120706010050804060Static Pressure (Pa)302010010° 15° 20° 25° 30° 35° 40°Static Pressure (Pa)4020010°15° 20° 25° 30° 35° 40°0 0.5 1 1.5Volume (m 3 /s)0 0.5 1 1.5 2Volume (m 3 /s)0.160.25Impeller Power, kW0.140.120.10.080.060.040.02015°10°20°25°30°35°40°Impeller Power, kW0.20.150.10.05010° 15° 20°25°30°35°40°0 0.5 1 1.50 0.5 1 1.5 2Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 63 59 61 59 59 58 52 44 4315° 66 62 61 60 60 59 53 44 4420° 67 62 61 61 61 60 53 45 4525° 69 64 63 63 63 62 55 47 4730° 70 68 64 68 65 60 54 43 4935° 70 65 64 64 64 63 56 48 4840° 70 66 64 64 64 63 57 48 48Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 63 68 64 62 62 61 55 47 4615° 66 71 64 63 63 62 56 47 4720° 67 71 64 64 64 63 56 48 4825° 69 73 66 66 66 65 58 50 5030° 70 77 67 71 68 63 57 46 5235° 70 74 67 67 67 66 59 51 5140° 70 75 67 67 67 66 60 51 51Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.128 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data450 Ø 12 rpsHub Ø 150Blades 5Hub Ø 150Blades 105080457040356030502540Static Pressure (Pa)2015105015°10°20°25° 30° 35°40°Static Pressure (Pa)302010010°15°20°25° 30° 35° 40°0 0.5 1 1.5Volume (m 3 /s)0 0.5 1 1.5Volume (m 3 /s)Impeller Power, kW0.070.060.050.040.030.020.01015°10°20°25°30°35°40°Impeller Power, kW0.10.090.080.070.060.050.040.030.020.01015°10°20°25°30°35°40°0 0.2 0.4 0.6 0.8 1 1.20 0.2 0.4 0.6 0.8 1 1.2Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 56 52 54 52 52 51 45 37 3615° 59 55 53 53 53 52 46 37 3720° 60 55 54 54 54 53 46 37 3825° 62 57 56 56 56 55 48 39 4030° 63 61 57 61 58 53 47 36 4235° 63 58 57 57 57 56 49 40 4140° 63 59 57 57 57 56 50 41 41Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 56 61 57 55 55 54 48 40 3915° 59 64 56 56 56 55 49 40 4020° 60 64 57 57 57 56 49 40 4125° 62 66 59 59 59 58 51 42 4330° 63 70 60 64 61 56 50 39 4535° 63 67 60 60 60 59 52 43 4440° 63 68 60 60 60 59 53 44 44Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 129


FANSCATALOGUEAdjustable Pitch Axial Performance Data500 Ø 48 rpsHub Ø 150Blades 5Hub Ø 150Blades 10900140080012007006001000500800400600Static Pressure (Pa)300200100010° 15° 20° 25° 30°35°40°Static Pressure (Pa)400200010° 15° 20° 25° 30° 35°40°0 2 4 6 8Volume (m 3 /s)0 2 4 6 8Volume (m 3 /s)712Impeller Power, kW654321015°10°20°25°30°35° 40°Impeller Power, kW108642010° 15° 20°25°30°35°40°0 2 4 6 80 2 4 6 8Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 84 85 86 92 90 85 79 70 7315° 84 86 89 91 89 86 80 72 7320° 87 88 94 93 90 88 83 75 7525° 86 86 95 90 88 86 81 74 7330° 88 88 94 91 89 86 82 77 7435° 90 93 90 92 90 87 82 77 7440° 88 90 87 89 87 84 79 75 71Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 89 90 89 102 95 90 84 75 8115° 89 91 92 101 94 91 85 77 8020° 90 91 94 102 93 91 86 78 8025° 88 90 91 96 96 94 91 87 8030° 87 90 90 96 95 93 90 86 7935° 89 92 92 97 96 94 91 87 8040° 88 91 90 95 94 91 88 85 78Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.130 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data500 Ø 24 rpsHub Ø 150Blades 5Hub Ø 150Blades 10250350200300250150200100150Static Pressure (Pa)50010° 15° 20° 25° 30°35°40°Static Pressure (Pa)10050010° 15° 20° 25° 30° 35°40°0 1 2 3 4Volume (m 3 /s)0 1 2 3 4Volume (m 3 /s)0.81.40.735° 40°1.240°Impeller Power, kW0.60.50.40.30.20.1010°15°20°25°30°Impeller Power, kW10.80.60.40.2015°10°20°25°30°35°0 1 2 3 40 1 2 3 4Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 69 73 68 77 75 70 64 55 5815° 69 74 71 76 74 71 65 57 5820° 70 75 75 76 74 71 66 58 5825° 69 73 75 74 72 69 65 58 5630° 69 72 72 72 70 67 63 58 5535° 72 74 73 75 72 69 64 61 5640° 72 73 70 74 71 67 62 61 55Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 73 74 78 81 79 74 68 59 6215° 75 76 83 82 80 76 71 62 6420° 76 77 86 82 80 77 72 64 6525° 76 77 88 80 78 76 71 64 6430° 77 77 86 80 78 75 71 66 6335° 79 78 86 82 79 76 71 68 6540° 72 75 74 79 78 75 72 69 62Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 131


FANSCATALOGUEAdjustable Pitch Axial Performance Data500 Ø 16 rpsHub Ø 150Blades 5Hub Ø 150Blades 109014080120706010050804060Static Pressure (Pa)302010010° 15° 20° 25° 30° 35°40°Static Pressure (Pa)4020010° 15° 20°25° 30° 35°40°0 0.5 1 1.5 2 2.5Volume (m 3 /s)0 0.5 1 1.5 2 2.5Volume (m 3 /s)0.250.40.235° 40°0.350.335°40°Impeller Power, kW0.150.10.05015°10°20°25°30°Impeller Power, kW0.250.20.150.10.05010° 15° 20°25°30°0 0.5 1 1.5 2 2.50 0.5 1 1.5 2 2.5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 66 65 63 72 69 65 59 50 5315° 67 66 66 71 69 66 60 52 5320° 69 67 70 72 70 67 62 54 5425° 69 67 72 70 68 66 61 54 5330° 69 66 69 69 67 64 60 55 5135° 71 67 69 71 68 65 60 57 5340° 71 66 66 70 67 63 58 57 51Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 66 74 66 75 72 68 62 53 5615° 65 72 67 72 70 66 61 52 5420° 67 73 72 73 71 68 63 55 5525° 67 73 74 71 69 67 62 55 5430° 68 73 72 71 69 66 62 57 5335° 71 75 73 74 71 68 63 60 5540° 71 74 70 73 70 66 61 60 54Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.132 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data500 Ø 12 rpsHub Ø 150Blades 5Hub Ø 150Blades 10608050706040503040Static Pressure (Pa)2010010° 15° 20° 25° 30°35°40°Static Pressure (Pa)302010010° 15° 20° 25° 30° 35°40°0 0.5 1 1.5 2Volume (m 3 /s)0 0.5 1 1.5 2Volume (m 3 /s)0.10.18Impeller Power, kW0.090.080.070.060.050.040.030.020.01010°15°20°25°30°35° 40°Impeller Power, kW0.160.140.120.10.080.060.040.02010° 15° 20°25°30°35°40°0 0.5 1 1.5 20 0.5 1 1.5 2Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 59 58 56 65 62 58 52 43 4615° 58 56 57 62 60 56 51 42 4420° 57 55 58 59 57 54 49 42 4125° 55 53 59 57 55 53 48 41 4030° 57 54 58 58 56 53 48 43 4035° 59 56 58 59 57 53 49 46 4140° 62 57 57 60 58 54 49 48 42Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 59 67 59 68 65 61 55 46 4915° 58 65 60 65 63 59 54 45 4720° 57 64 61 62 60 57 52 45 4425° 55 62 62 60 58 56 51 44 4330° 57 63 61 61 59 56 51 46 4335° 59 65 61 62 60 56 52 49 4440° 62 66 60 63 61 57 52 51 45Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 133


FANSCATALOGUEAdjustable Pitch Axial Performance Data560 Ø 24 rpsHub Ø 150Blades 5Hub Ø 150Blades 10250400350200300150250200Static Pressure, Pa10050010° 15° 20° 25° 30° 35° 40°Static Pressure, Pa15010050010°15°20° 25° 30° 35° 40°0 1 2 3 4 5Volume m 3 /s0 1 2 3 4 5Volume m 3 /s1.41.2135°40°2.5235°40°Impeller Power, kW0.80.60.40.2015°10°25°20°30°Impeller Power, kW1.510.5015°10°20°25°30°0 1 2 3 4 50 1 2 3 4 5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 69 73 68 77 75 70 64 55 5815° 69 74 71 76 74 71 65 57 5820° 73 77 77 79 77 74 69 61 6125° 72 76 78 76 74 72 67 60 5930° 74 77 77 77 75 72 68 63 5935° 75 77 76 78 75 72 67 64 5940° 74 75 72 76 73 69 64 63 57Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 74 75 79 82 80 75 69 60 6315° 74 76 82 81 79 76 70 62 6320° 76 77 86 82 80 77 72 64 6525° 75 76 87 79 77 75 70 63 6330° 79 79 88 82 80 77 73 68 6535° 79 78 86 82 79 76 71 68 6440° 81 79 85 83 80 76 71 70 65Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.134 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data560 Ø 24 rpsHub Ø 250Blades 7Hub Ø 250Blades 14350450300400350250300200250150200Static Pressure (Pa)10050015°10°20° 25° 30° 35°40°Static Pressure (Pa)15010050010°15°20°25°30°35° 40°0 1 2 3 4 5Volume m 3 /s0 1 2 3 4 5Volume m 3 /sImpeller Power, kW1.61.41.210.80.60.40.2015°10°20°25°30°35°40°Impeller Power, kW2.521.510.5015°10°20°25°30°35°40°0 1 2 3 4 50 1 2 3 4 5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 68 69 65 81 80 76 71 65 6315° 69 70 68 80 79 76 72 66 6320° 76 77 85 80 78 76 71 62 6325° 73 76 76 82 82 79 77 72 6530° 67 70 70 76 75 73 70 66 5935° 71 74 74 79 78 76 73 69 6240° 71 74 73 78 77 75 72 68 61Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 73 71 76 86 85 81 76 70 6815° 72 71 77 83 83 79 75 70 6620° 74 73 81 84 83 80 77 72 6725° 75 75 84 84 84 81 79 74 6830° 70 70 79 79 78 76 73 69 6235° 72 72 81 80 79 77 74 70 6440° 73 73 81 80 79 77 74 70 63Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 135


FANSCATALOGUEAdjustable Pitch Axial Performance Data560 Ø 16 rpsHub Ø 150Blades 5Hub Ø 150Blades 1010018090160801407012060504010080Static Pressure, Pa302010010° 15° 20° 25° 30° 35°40°Static Pressure, Pa604020010° 15° 20° 25° 30° 35° 40°0 1 2 3Volume m 3 /s0 1 2 3 4Volume m 3 /sImpeller Power, kW0.40.350.30.250.20.150.10.05015°10°25°20°30°35°40°Impeller Power, kW0.60.50.40.30.20.1010°15°20°25°30°35°40°0 0.5 1 1.5 2 2.5 30 1 2 3 4Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 69 67 65 74 72 68 62 52 5515° 70 69 69 74 72 69 63 55 5520° 71 69 72 74 72 69 64 56 5625° 73 71 76 74 72 70 65 58 5730° 73 70 73 73 71 68 64 59 5635° 77 73 75 77 74 71 66 63 5840° 76 71 71 75 72 68 63 62 56Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 69 76 68 77 75 71 65 55 5815° 67 75 69 75 72 69 63 55 5620° 71 77 76 77 75 72 67 59 5925° 72 78 79 76 74 72 67 60 5930° 72 77 76 75 73 70 66 61 5835° 75 79 77 78 75 72 67 64 5940° 75 78 74 77 74 70 65 64 58Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.136 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data560 Ø 16 rpsHub Ø 250Blades 7Hub Ø 250Blades 14140180120160140100120801006080Static Pressure (Pa)4020015°10°20°25° 30° 35°40°Static Pressure (Pa)604020010°15°20° 25° 30°35° 40°0 1 2 3Volume m 3 /s0 1 2 3 4Volume m 3 /s0.450.7Impeller Power, kW0.40.350.30.250.20.150.10.05015°10°20°25°30°35°40°Impeller Power, kW0.60.50.40.30.20.1015°10°20°25°30°35°40°0 0.5 1 1.5 2 2.5 30 1 2 3 4Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 61 62 58 74 73 69 64 58 5615° 62 63 61 73 72 69 65 59 5620° 61 62 60 72 71 68 64 58 5425° 63 66 66 72 72 69 67 62 5630° 62 65 65 71 70 68 65 61 5535° 66 69 69 74 73 71 68 64 5840° 65 65 67 72 71 69 66 62 55Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 64 67 62 77 76 72 67 61 5915° 64 67 62 77 76 72 67 61 5920° 68 72 70 78 77 74 71 66 6125° 66 71 70 75 75 72 70 65 5930° 61 66 65 70 69 67 64 60 5335° 63 68 67 71 70 68 65 61 5540° 64 69 67 71 70 68 65 61 54Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 137


FANSCATALOGUEAdjustable Pitch Axial Performance Data560 Ø 12 rpsHub Ø 150Blades 5Hub Ø 150Blades 1060100905080407060305040Static Pressure, Pa2010010° 15° 20° 25° 30° 35°40°Static Pressure, Pa302010010°15°20° 25° 30° 35° 40°0 0.5 1 1.5 2 2.5Volume m 3 /s0 0.5 1 1.5 2 2.5Volume m 3 /s0.180.30.160.140.1235°40°0.250.235°40°Impeller Power, kW0.10.080.060.040.02015°10°25°20°30°Impeller Power, kW0.150.10.05015°10°20°25°30°0 0.5 1 1.5 2 2.50 0.5 1 1.5 2 2.5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 62 60 58 67 65 60 55 45 4815° 60 59 59 65 62 59 53 45 4620° 59 57 60 62 60 57 52 44 4425° 58 56 61 59 57 55 51 43 4230° 60 57 61 61 58 55 51 46 4335° 62 58 60 62 59 56 51 48 4340° 64 59 60 63 60 56 51 50 44Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 62 69 61 70 68 63 58 48 5115° 60 68 62 68 65 62 56 48 4920° 59 66 63 65 63 60 55 47 4725° 58 65 64 62 60 58 54 46 4530° 60 66 64 64 61 58 54 49 4635° 62 67 63 65 62 59 54 51 4640° 64 68 63 66 63 59 54 53 47Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.138 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data560 Ø 12 rpsHub Ø 250Blades 7Hub Ø 250Blades 149012080701006080504060Static Pressure, Pa302010015°10°20° 25° 30° 35° 40°Static Pressure, Pa4020010°15°20°25°30°35° 40°0 0.5 1 1.5 2 2.5Volume m 3 /s0 0.5 1 1.5 2 2.5Volume m 3 /s0.20.3Impeller Power, kW0.180.160.140.120.10.080.060.040.02015°10°20°25°30°35°40°Impeller Power, kW0.250.20.150.10.05015°10°20°25°30°35°40°0 0.5 1 1.5 2 2.50 0.5 1 1.5 2 2.5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 60 55 54 69 68 65 60 54 5115° 58 54 54 67 66 63 58 53 4920° 57 53 55 64 64 61 57 52 4725° 56 52 56 61 61 59 56 52 4530° 57 54 57 63 62 60 57 53 4635° 59 56 59 64 63 61 58 54 4740° 61 58 60 65 64 62 59 55 48Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 60 64 57 72 71 68 63 57 5415° 58 63 57 70 69 66 61 56 5220° 57 62 58 67 67 64 60 55 5025° 56 61 59 64 64 62 59 55 4830° 57 63 60 66 65 63 60 56 4935° 59 65 62 67 66 64 61 57 5040° 61 67 63 68 67 65 62 58 51Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 139


FANSCATALOGUEAdjustable Pitch Axial Performance Data630 Ø 24 rpsHub Ø 150Blades 5Hub Ø 150Blades 10300450250400350200300150250200Static Pressure, Pa10050015°10°20°25° 30°35°40°Static Pressure, Pa15010050010° 15° 20° 25° 30° 35° 40°-2 0 2 4 6 8Volume m 3 /s0 2 4 6 8Volume m 3 /s2.53.5240°32.535°40°Impeller Power, kW1.510.5015°10°20°35°30°25°Impeller Power, kW21.510.5010° 15° 20°25°30°-2 0 2 4 6 80 2 4 6 8Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 72 76 71 80 78 73 67 58 6115° 72 77 74 79 77 74 68 60 6120° 75 80 80 81 79 76 71 64 6325° 77 81 83 81 79 77 72 65 6430° 76 79 80 80 78 75 70 65 6235° 78 81 79 81 79 75 70 68 6340° 80 82 79 82 80 76 71 70 64Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 81 83 87 90 87 83 77 68 7115° 80 81 88 87 85 81 76 67 6920° 78 80 89 84 82 79 74 67 6725° 77 78 89 82 80 77 73 66 6530° 79 79 89 83 81 78 73 68 6635° 81 81 88 84 82 78 73 71 6640° 83 82 88 85 83 79 74 73 67Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.140 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data630 Ø 24 rpsHub Ø 250Blades 7Hub Ø 250Blades 1470120601005080406030Static Pressure, Pa2010010°15°20°25° 30°35°40°Static Pressure, Pa4020010° 15° 20° 25° 30° 35° 40°-1 0 1 2 3 4Volume m 3 /s0 1 2 3 4Volume m 3 /s0.30.4Impeller Power, kW0.250.20.150.10.05010°15°20°35°30°25°40°Impeller Power, kW0.350.30.250.20.150.10.05010° 15° 20°25°30°35°40°-1 0 1 2 3 40 0.5 1 1.5 2 2.5 3 3.5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 69 70 66 82 81 77 72 66 6415° 79 80 86 83 82 79 73 65 6620° 73 75 74 83 83 80 77 72 6625° 74 77 77 83 83 80 78 73 6730° 71 74 74 80 79 77 74 70 6435° 74 77 77 82 81 79 76 72 6540° 74 77 76 81 80 78 75 71 64Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 74 72 77 87 86 82 77 71 6915° 78 76 83 89 88 85 81 75 7220° 76 75 83 86 86 83 80 75 7025° 76 76 85 85 85 82 80 75 6930° 74 74 83 83 82 80 77 73 6735° 77 77 86 85 84 82 79 75 6840° 76 76 84 83 82 80 77 73 66Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 141


FANSCATALOGUEAdjustable Pitch Axial Performance Data630 Ø 16 rpsHub Ø 150Blades 5Hub Ø 150Blades 10120180100160140801206010080Static Pressure (Pa)4020010°15°20° 25° 30°35° 40°Static Pressure (Pa)604020010° 15° 20° 25° 30° 35° 40°0 1 2 3 4Volume (m 3 /s)0 1 2 3 4 5Volume (m 3 /s)0.60.90.540°0.80.740°35°Impeller Power, kW0.40.30.20.1015°10°25°20°35°30°Impeller Power, kW0.60.50.40.30.20.1010° 15° 20°25°30°0 1 2 3 40 1 2 3 4 5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 71 70 68 77 74 70 64 55 5815° 73 72 72 77 75 72 66 58 5820° 75 73 76 78 76 73 68 60 6025° 76 74 79 77 75 73 68 61 6030° 77 74 77 77 75 72 68 63 5935° 79 75 77 79 76 73 68 65 6040° 78 73 73 77 74 70 65 64 58Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 71 79 71 80 77 73 67 58 6115° 70 77 72 77 75 71 66 57 5920° 70 76 75 76 74 71 66 58 5825° 70 76 77 74 72 70 65 58 5730° 72 77 76 75 73 70 66 61 5735° 74 78 76 77 74 71 66 63 5940° 75 78 74 77 74 70 65 64 58Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.142 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data630 Ø 16 rpsHub Ø 250Blades 7Hub Ø 250Blades 1418025016014020012010015080100Static Pressure (Pa)604020010°15°20° 25° 30° 35°40°Static Pressure (Pa)50010°15°20°25°30°35° 40°0 1 2 3 4 5Volume (m 3 /s)0 1 2 3 4 5Volume (m 3 /s)0.91.4Impeller Power, kW0.80.70.60.50.40.30.20.1040°35°30°25°20°15°10°0 1 2 3 4 5Impeller Power, kW1.210.80.60.40.2015°10°20°25°30°35°40°0 1 2 3 4 5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 63 64 60 76 75 71 66 60 5815° 64 65 63 75 74 71 67 61 5820° 62 63 61 73 72 69 65 59 5625° 63 66 66 72 72 69 67 62 5630° 64 64 67 72 72 69 66 62 5635° 66 66 68 74 73 70 67 63 5740° 68 68 70 75 74 71 68 64 58Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 66 69 64 79 78 74 69 63 6215° 67 70 65 80 79 75 70 64 6220° 65 69 67 75 74 71 68 63 5825° 68 73 72 77 77 74 72 67 6130° 67 73 70 75 75 72 69 65 5935° 69 75 71 77 76 73 70 66 6040° 71 77 73 78 77 74 71 67 61Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 143


FANSCATALOGUEAdjustable Pitch Axial Performance Data630 Ø 12 rpsHub Ø 150Blades 5Hub Ø 150Blades 1070120601005080406030Static Pressure (Pa)2010010°15°20° 25° 30°35°40°Static Pressure (Pa)4020010° 15° 20° 25° 30° 35° 40°0 1 2 3 4Volume (m 3 /s)0 1 2 3 4Volume (m 3 /s)0.30.4Impeller Power, kW0.250.20.150.10.05015°10°20°25°35°30°40°Impeller Power, kW0.350.30.250.20.150.10.05010° 15° 20° 25° 30°40°35°0 1 2 3 40 1 2 3 4Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 67 65 63 72 70 65 59 50 5315° 68 67 67 72 70 67 61 53 5320° 71 69 72 74 72 69 64 56 5625° 71 69 74 72 70 68 63 56 5530° 72 69 72 72 70 67 63 58 5435° 73 69 71 73 70 67 62 59 5540° 74 69 69 73 70 66 61 60 54Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 64 72 64 73 70 66 60 51 5415° 65 72 68 72 70 67 61 53 5420° 64 70 69 70 68 65 60 52 5225° 64 70 71 68 66 64 59 52 5130° 66 71 70 69 67 64 60 55 5135° 69 73 71 72 69 66 61 58 5340° 68 71 67 70 67 63 58 57 51Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.144 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data630 Ø 12 rpsHub Ø 250Blades 7Hub Ø 250Blades 141001409080120701006080504060Static Pressure (Pa)302010010° 15° 20° 25° 30° 35°40°Static Pressure (Pa)4020010° 15° 20°25° 30° 35° 40°0 1 2 3 4Volume (m 3 /s)0 1 2 3 4Volume (m 3 /s)0.350.6Impeller Power, kW0.30.250.20.150.10.05015°10°40°35°25° 30°20°Impeller Power, kW0.50.40.30.20.1015°10°20°25°30°35°40°0 1 2 3 40 1 2 3 4Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 59 54 53 69 68 64 59 53 5215° 61 56 57 69 68 65 61 55 5220° 59 55 57 67 66 63 60 55 5025° 58 54 58 64 64 61 58 54 4830° 60 57 60 65 65 62 59 55 4935° 64 61 64 69 68 66 63 59 5240° 63 61 63 68 67 64 61 57 51Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 62 66 59 75 74 70 65 59 5715° 61 65 60 72 71 68 64 58 5520° 63 67 65 73 72 69 66 61 5625° 62 67 66 71 71 68 66 61 5530° 60 66 63 68 68 65 62 58 5235° 62 68 64 69 69 66 63 59 5340° 63 70 66 71 70 67 64 60 54Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 145


FANSCATALOGUEAdjustable Pitch Axial Performance Data710 Ø 24 rpsHub Ø 150Blades 5Hub Ø 150Blades 10350500300450400250350200300250150200Static Pressure, Pa10050010° 15° 20°25° 30° 35° 40°Static Pressure, Pa15010050015°10°20° 25° 30°35° 40°0 2 4 6 8 10Volume m 3 /s0 2 4 6 8 10Volume m 3 /sImpeller Power, kW3.532.521.510.5010° 15° 20°25°35°30°40°Impeller Power, kW54.543.532.521.510.5015°10°20°25°30°35°40°0 2 4 6 8 100 2 4 6 8 10Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 74 78 73 82 80 75 69 60 6315° 74 79 76 81 79 76 70 62 6320° 78 82 82 84 82 79 74 66 6625° 80 84 86 84 82 80 75 68 6630° 79 82 83 83 80 77 73 68 6535° 81 83 82 84 81 78 73 70 6540° 83 84 82 85 82 78 73 73 66Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 78 79 83 86 84 79 73 64 6715° 79 81 87 86 84 81 75 67 6920° 81 82 91 87 85 82 77 69 7025° 80 81 92 84 82 80 76 69 6830° 82 82 92 86 83 80 76 71 6935° 84 83 91 87 84 81 76 73 6940° 79 82 81 86 85 82 79 76 69Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.146 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data710 Ø 24 rpsHub Ø 250Blades 7Hub Ø 250Blades 14450600400350500300400250200300Static Pressure (Pa)15010050010°15°20°25° 30° 35° 40°0 2 4 6 8 10Volume m 3 /sStatic Pressure, Pa200100010°15°20° 25° 30° 35° 40°0 2 4 6 8 10Volume m 3 /sImpeller Power, kW4.543.532.521.510.5015°10°20°30°25°35°40°0 2 4 6 8 10Impeller Power, kW654321010°15°20°25°30°35°40°0 2 4 6 8 10Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 79 80 85 85 83 80 74 65 6715° 72 73 71 83 82 79 75 69 6620° 76 78 77 86 86 83 79 74 6925° 75 77 78 83 83 81 78 74 6730° 72 75 75 81 80 78 75 71 6435° 75 78 78 83 82 80 77 73 6740° 75 78 77 82 81 79 76 72 65Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 78 76 81 91 90 86 81 75 7315° 80 79 85 92 91 88 83 78 7520° 79 78 86 89 89 86 82 77 7225° 79 79 88 88 88 85 83 78 7230° 79 79 88 88 87 85 82 78 7135° 81 81 90 89 88 86 83 79 7240° 83 83 91 90 89 87 84 80 73Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 147


FANSCATALOGUEAdjustable Pitch Axial Performance Data710 Ø 16 rpsHub Ø 150Blades 5Hub Ø 150Blades 101602501401202001001508060100Static Pressure, Pa4020010° 15° 20°25° 30° 35° 40°Static Pressure, Pa50015°10°20° 25° 30° 35°40°0 2 4 6Volume m 3 /s0 2 4 6 8Volume m 3 /s0.91.4Impeller Power, kW0.80.70.60.50.40.30.20.1010° 15° 20°25°30°35°40°Impeller Power, kW1.210.80.60.40.2015°10°20°25°30°35°40°0 1 2 3 4 5 60 2 4 6 8Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 71 69 67 76 74 69 63 54 5815° 73 71 71 77 74 71 65 57 5820° 74 72 75 77 75 72 67 59 5925° 75 73 78 76 74 72 67 60 5930° 77 74 77 77 75 72 68 63 6035° 80 76 78 80 77 74 69 66 6240° 79 74 74 78 75 71 66 65 59Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 70 76 70 78 76 71 65 56 5915° 73 80 74 80 77 74 68 60 6120° 75 81 80 81 79 76 71 63 6325° 76 82 83 80 78 76 71 64 6330° 75 80 79 78 76 73 69 64 6035° 78 82 80 81 78 75 70 67 6340° 78 81 77 80 77 73 68 67 61Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.148 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data710 Ø 16 rpsHub Ø 250Blades 7Hub Ø 250Blades 1418025016014020012010015080100Static Pressure (Pa)604020010°15°20°25° 30° 35° 40°Static Pressure (Pa)50010° 15° 20° 25° 30° 35° 40°0 2 4 6Volume m 3 /s0 2 4 6 8Volume m 3 /sImpeller Power, kW1.210.80.60.40.2015°10°20°25°30°35°40°Impeller Power, kW1.61.41.210.80.60.40.2010°15°20°25°30°35°40°0 1 2 3 4 5 60 2 4 6 8Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 66 67 63 79 78 74 69 63 6115° 67 68 66 78 77 74 70 64 6120° 66 65 67 76 76 73 69 64 5925° 65 64 68 74 73 71 68 64 5730° 66 66 69 75 74 72 69 65 5835° 68 68 71 76 76 73 70 66 6040° 67 70 69 74 73 71 68 64 57Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 71 74 69 84 83 79 74 68 6615° 70 75 69 82 81 78 74 68 6520° 73 77 75 83 82 79 76 71 6625° 74 79 78 83 83 80 78 73 6630° 72 77 76 81 80 78 75 71 6435° 76 81 80 84 83 81 78 74 6840° 77 82 80 84 83 81 78 74 67Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 149


FANSCATALOGUEAdjustable Pitch Axial Performance Data710 Ø 12 rpsHub Ø 150Blades 5Hub Ø 150Blades 109014080120706010050804060Static Pressure, Pa302010010° 15° 20°25° 30° 35° 40°Static Pressure, Pa4020015°10°20° 25° 30°35° 40°0 1 2 3 4 5Volume m 3 /s0 1 2 3 4 5Volume m 3 /s0.40.7Impeller Power, kW0.350.30.250.20.150.10.05010° 15° 20°25°30°35°40°Impeller Power, kW0.60.50.40.30.20.1015°10°20°25°30°35°40°0 1 2 3 4 50 1 2 3 4 5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 67 65 64 72 70 66 60 50 5315° 65 64 64 70 67 64 58 50 5120° 69 67 70 72 70 67 62 54 5425° 70 68 73 71 69 67 62 55 5430° 72 69 72 72 70 67 63 58 5535° 76 72 74 76 73 70 65 62 5740° 75 70 70 74 71 67 62 61 56Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 64 70 64 72 70 65 59 50 5315° 65 73 67 73 70 67 61 53 5420° 69 75 74 75 73 70 65 57 5825° 70 76 77 74 72 70 65 58 5630° 69 74 73 72 70 67 63 58 5435° 72 76 74 75 72 69 64 61 5640° 72 75 71 74 71 67 62 61 55Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.150 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data710 Ø 12 rpsHub Ø 250Blades 7Hub Ø 250Blades 14120160100140120801006080Static Pressure, Pa4020010°15°20°25° 30° 35° 40°Static Pressure, Pa604020010° 15° 20° 25° 30° 35° 40°0 1 2 3 4 5Volume m 3 /s0 1 2 3 4 5Volume m 3 /s0.60.80.50.435°40°0.70.60.535°40°Impeller Power, kW0.30.20.1010° 15° 20°30°25°Impeller Power, kW0.40.30.20.1010°15°20°25°30°0 1 2 3 4 50 1 2 3 4 5Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 65 60 59 75 73 70 65 59 5715° 63 59 59 72 71 68 64 58 5520° 62 58 60 69 69 66 62 57 5225° 61 57 61 67 66 64 61 57 5030° 62 59 62 68 67 65 62 58 5135° 64 61 64 69 68 66 63 59 5240° 66 63 65 70 69 67 64 60 53Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 65 69 62 78 76 73 68 62 6015° 65 68 63 78 77 73 68 62 6020° 68 72 70 78 77 74 71 66 6125° 68 73 72 77 77 74 72 67 6130° 66 71 70 75 74 72 69 65 5835° 70 75 74 78 77 75 72 68 6240° 70 75 73 77 76 74 71 67 60Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 151


FANSCATALOGUEAdjustable Pitch Axial Performance Data800 Ø 24 rpsHub Ø 150Blades 5Hub Ø 150Blades 10400600350500300250400200300Static Pressure, Pa15010050010° 15°20° 25° 30°35° 40°Static Pressure, Pa200100010°15°20° 25° 30° 35° 40°0 5 10 15Volume m 3 /s0 5 10 15Volume m 3 /sImpeller Power, kW54.543.532.521.510.5010°15°20°25°30°35°40°Impeller Power, kW7654321010° 15° 20°25°30°35°40°0 2 4 6 8 10 120 5 10 15Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 79 83 78 87 85 80 74 65 6815° 79 84 81 86 84 81 75 67 6820° 78 82 82 84 82 79 74 66 6625° 79 83 86 84 82 80 75 68 6730° 88 91 91 91 89 86 82 77 7335° 90 92 91 93 90 87 82 79 7540° 81 83 80 82 80 77 72 68 64Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 83 84 88 91 89 84 78 69 7215° 83 85 91 90 88 85 79 71 7220° 84 85 94 90 87 84 80 72 7225° 82 83 95 87 85 83 78 71 7130° 78 81 81 87 86 84 81 77 7035° 79 82 82 87 86 84 81 77 7040° 79 82 81 86 85 82 79 76 69Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.152 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data800 Ø 24 rpsHub Ø 250Blades 7Hub Ø 250Blades 14450700400600350300500250400200300Static Pressure, Pa15010050010° 15°20° 25° 30° 35° 40°Static Pressure, Pa200100010° 15°20° 25° 30°35° 40°0 5 10 15Volume m 3 /s0 5 10 15Volume m 3 /s812Impeller Power, kW7654321010° 15° 20°25°30°35°40°Impeller Power, kW108642010°15°20°25° 30° 35°40°0 5 10 150 5 10 15Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 76 77 73 89 88 84 79 73 7115° 77 78 76 88 87 84 80 74 7020° 76 77 75 87 86 83 79 73 7025° 77 80 80 86 86 83 80 76 7030° 76 79 79 85 84 82 79 75 6835° 79 82 82 87 86 84 81 77 7040° 78 81 80 85 84 82 79 75 69Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 84 83 87 97 96 92 87 81 7915° 84 82 87 97 96 92 87 81 7920° 85 84 92 95 94 91 88 83 7725° 85 85 94 94 94 91 89 84 7830° 83 83 92 92 91 89 86 82 7635° 87 87 96 95 94 92 89 85 7940° 86 86 94 93 92 90 87 83 77Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 153


FANSCATALOGUEAdjustable Pitch Axial Performance Data800 Ø 24 rpsHub Ø 255Blades 6Hub Ø 255Blades 12500800450700400350600300500250400Static Pressure, Pa2001501005005°10° 15° 20° 25° 30°Static Pressure (Pa)30020010005° 10° 15° 20° 25° 30° 35°0 5 10 15Volume m 3 /s0 5 10 15Volume (m 3 /s)610530°9835°Impeller Power, kW432105°10°15°20°25°0 2 4 6 8 10 12Impeller Power, kW765432105°10°15°20°25°30°0 5 10 15Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 92 93 87 85 86 85 80 71 7010° 92 93 87 85 86 85 80 71 7015° 90 91 85 83 84 83 78 69 6820° 92 93 87 85 86 85 80 71 7025° 94 95 89 87 88 87 82 73 7230° 96 97 91 89 90 89 84 75 74Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 94 92 92 88 91 88 83 72 7410° 94 92 92 88 91 88 83 72 7415° 95 93 93 89 92 89 84 73 7520° 97 95 95 91 94 91 86 75 7725° 98 96 96 92 95 92 87 76 7830° 100 98 98 94 97 94 89 78 8035° 102 100 100 96 99 96 91 80 82Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.154 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data800 Ø 24 rpsHub Ø 400Blades 4Hub Ø 400Blades 8450700400600350300500250400200300Static Pressure ( Pa)1501005000° 5° 10°15°20°25° 30° 35°0 5 10 15 20Volume (m 3 /s)Static Pressure (Pa)20010000°5° 10° 15° 20°25° 30° 35°0 5 10 15 20Volume (m 3 /s)Impeller Power, kW1210864200°5° 10° 15°20°25°30°35°Impeller Power, kW16141210864200°5°10°15°20°25°30°35°0 5 10 15 200 5 10 15 20Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 81 90 88 87 83 78 74 67 685° 80 89 87 86 82 77 73 66 6710° 79 88 86 85 81 76 72 65 6615° 79 88 86 85 81 76 72 65 6620° 79 88 86 85 81 76 72 65 6625° 79 88 86 85 81 76 72 65 6630° 80 89 87 86 82 77 73 66 6735° 81 90 88 87 83 78 74 67 68Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 84 93 91 90 86 81 77 70 715° 83 92 90 89 85 80 76 69 7010° 82 91 89 88 84 79 75 68 6915° 82 91 89 88 84 79 75 68 6920° 82 91 89 88 84 79 75 68 6925° 82 91 89 88 84 79 75 68 6930° 83 92 90 89 85 80 76 69 7035° 83 92 90 89 85 80 76 69 70Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 155


FANSCATALOGUEAdjustable Pitch Axial Performance Data800 Ø 24 rpsHub Ø 400Blades 12Hub Ø 400Blades 16700800600700500600400500400Static Pressure, Pa30020010000°5° 10° 15° 20° 25°30°35°Static Pressure, Pa30020010000° 5° 10° 15° 20° 25° 30° 35°0 5 10 15 20Volume (m 3 /s)0 5 10 15 20Volume (m 3 /s)181816141230°35°16141230°35°Impeller Power, kW10864200°5° 10° 15°20°25°0 5 10 15 20Impeller Power, kW10864200° 5° 10° 15°20°25°0 5 10 15 20Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 85 90 93 91 88 83 79 72 725° 84 89 92 90 87 82 78 71 7110° 83 88 91 89 86 81 77 70 7015° 82 87 90 88 85 80 76 69 6920° 83 88 91 89 86 81 77 70 7025° 83 88 91 89 86 81 77 70 7030° 83 88 91 89 86 81 77 70 7035° 84 89 92 90 87 82 78 71 71Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 85 86 94 92 89 85 80 73 735° 85 86 94 92 89 85 80 73 7310° 83 84 92 90 87 83 78 71 7115° 83 84 92 90 87 83 78 71 7120° 83 84 92 90 87 83 78 71 7125° 84 85 93 91 88 84 79 72 7230° 84 85 93 91 88 84 79 72 7235° 85 86 94 92 89 85 80 73 73Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.156 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data800 Ø 16 rpsHub Ø 150Blades 5Hub Ø 150Blades 1016025014012020010015080Static Pressure, Pa604020010° 15°20° 25° 30° 35° 40°Static Pressure (Pa)10050010°15°20° 25° 30° 35° 40°0 2 4 6 8Volume (m 3 /s)0 2 4 6 8 10Volume (m 3 /s)1.42Impeller Power, kW1.210.80.60.40.2010°15°20°25°30°35°40°Impeller Power, kW1.81.61.41.210.80.60.40.2010° 15° 20°25°30°35°40°0 2 4 6 80 2 4 6 8 10Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 76 75 73 82 80 75 69 60 6315° 79 78 78 83 81 78 72 64 6520° 78 76 79 81 79 76 71 63 6325° 80 78 83 81 79 77 72 65 6330° 83 80 83 83 81 78 74 69 6535° 86 82 84 86 83 80 75 72 6740° 78 80 77 79 77 74 69 65 61Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 76 84 76 85 83 78 72 63 6615° 75 82 77 82 80 76 71 62 6420° 77 83 82 83 81 78 73 65 6625° 78 84 85 82 80 78 73 66 6530° 80 85 84 83 81 78 74 69 6535° 82 86 84 85 82 79 74 71 6740° 73 76 75 80 79 76 73 70 63Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 157


FANSCATALOGUEAdjustable Pitch Axial Performance Data800 Ø 16 rpsHub Ø 250Blades 7Hub Ø 250Blades 1418030016014025012020010080150Static Pressure (Pa)604020015°20° 25° 30° 35° 40°Static Pressure (Pa)10050010° 15°20° 25° 30°35° 40°0 2 4 6 8 10Volume (m 3 /s)0 2 4 6 8 10Volume (m 3 /s)21.81.640°32.540°Impeller Power, kW1.41.210.80.60.40.2015°20°25°30°35°Impeller Power, kW21.510.5010°15°20°25° 30° 35°0 2 4 6 8 100 2 4 6 8 10Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 70 69 69 81 81 77 73 68 6420° 67 68 66 78 77 74 70 64 6125° 67 67 70 76 76 73 71 66 6030° 67 70 70 76 75 73 70 66 5935° 68 71 71 76 75 73 70 66 5940° 68 71 70 75 74 72 69 65 58Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 72 75 70 85 84 80 75 69 6715° 73 78 72 84 84 80 76 71 6720° 75 79 77 85 84 81 78 73 6725° 76 81 80 85 85 82 80 75 6830° 75 80 79 84 83 81 78 74 6835° 79 84 83 87 86 84 81 77 7040° 78 83 81 85 84 82 79 75 68Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.158 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data800 Ø 16 rpsHub Ø 255Blades 6Hub Ø 255Blades 12250350200300250150200100150Static Pressure (Pa)5005°10°15° 20° 25°30°Static Pressure (Pa)1005005° 10° 15° 20° 25° 30° 35°0 2 4 6 8Volume (m 3 /s)0 2 4 6 8 10Volume (m 3 /s)1.631.41.2125°30°2.5230°35°Impeller Power, kW0.80.60.40.205°10°15°20°Impeller Power, kW1.510.505°10°15°20°25°0 2 4 6 80 2 4 6 8 10Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 83 84 78 76 77 76 71 62 6110° 82 83 77 75 76 75 70 61 6015° 81 82 76 74 75 74 69 60 5920° 82 83 77 75 76 75 70 61 6025° 84 85 79 77 78 77 72 63 6230° 86 87 81 79 80 79 74 65 64Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 85 83 83 79 82 79 74 63 6510° 85 83 83 79 82 79 74 63 6515° 86 84 84 80 83 80 75 64 6620° 87 85 85 81 84 81 76 65 6725° 89 87 87 83 86 83 78 67 6930° 90 88 88 84 87 84 79 68 7035° 93 91 91 87 90 87 82 71 73Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 159


FANSCATALOGUEAdjustable Pitch Axial Performance Data800 Ø 16 rpsHub Ø 400Blades 4Hub Ø 400Blades 820030018016025014020012010015080Static Pressure (Pa)60402000° 5°10°15°20°25° 30° 35°Static Pressure (Pa)1005000°5° 10°15°20°25° 30° 35°0 5 10 15Volume (m 3 /s)0 5 10 15Volume (m 3 /s)Impeller Power, kW3.532.521.510.500°5° 10° 15°20°25°30°35°Impeller Power, kW54.543.532.521.510.500°5°10°15°20°25°30°35°0 2 4 6 8 10 120 2 4 6 8 10 12Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 71 80 78 77 73 68 64 57 585° 70 79 77 76 72 67 63 56 5710° 69 78 76 75 71 66 62 55 5615° 69 78 76 75 71 66 62 55 5620° 69 78 76 75 71 66 62 55 5625° 70 79 77 76 72 67 63 56 5730° 70 79 77 76 72 67 63 56 5735° 71 80 78 77 73 68 64 57 58Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 74 83 81 80 76 71 67 60 615° 73 82 80 79 75 70 66 59 6010° 72 81 79 78 74 69 65 58 5915° 72 81 79 78 74 69 65 58 5920° 72 81 79 78 74 69 65 58 5925° 73 82 80 79 75 70 66 59 6030° 73 82 80 79 75 70 66 59 6035° 73 82 80 79 75 70 66 59 60Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.160 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data800 Ø 16 rpsHub Ø 400Blades 12Hub Ø 400Blades 16300350250300200250200150150Static Pressure (Pa)1005000° 5° 10° 15° 20° 25°30° 35°Static Pressure (Pa)1005000° 5° 10°15° 20° 25° 30° 35°0 5 10 15Volume (m 3 /s)0 5 10 15Volume (m 3 /s)56Impeller Power, kW4.543.532.521.510.500°5°10°15°20°25°30°35°0 2 4 6 8 10 12Impeller Power, kW5432100° 5° 10° 15°20°25°30°35°0 2 4 6 8 10 12Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 75 80 83 81 78 73 69 62 625° 74 79 82 80 77 72 68 61 6110° 73 78 81 79 76 71 67 60 6015° 72 77 80 78 75 70 66 59 5920° 73 78 81 79 76 71 67 60 6025° 73 78 81 79 76 71 67 60 6030° 74 79 82 80 77 72 68 61 6135° 74 79 82 80 77 72 68 61 61Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 76 77 85 83 80 76 71 64 645° 75 76 84 82 79 75 70 63 6310° 74 75 83 81 78 74 69 62 6215° 73 74 82 80 77 73 68 61 6120° 74 75 83 81 78 74 69 62 6225° 74 75 83 81 78 74 69 62 6230° 74 75 83 81 78 74 69 62 6235° 75 76 84 82 79 75 70 63 63Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 161


FANSCATALOGUEAdjustable Pitch Axial Performance Data800 Ø 12 rpsHub Ø 150Blades 5Hub Ø 150Blades 109014080120706010050804060Static Pressure (Pa)302010010° 15°20° 25° 30° 35° 40°Static Pressure (Pa)4020010°15°20° 25° 30° 35° 40°0 2 4 6Volume (m 3 /s)0 2 4 6 8Volume (m 3 /s)0.60.9Impeller Power, kW0.50.40.30.20.1010°15°20°25°30°35°40°Impeller Power, kW0.80.70.60.50.40.30.20.1010° 15° 20°25°30°35°40°0 1 2 3 4 5 60 2 4 6 8Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 73 71 69 78 76 71 65 56 5915° 74 73 73 78 76 73 67 59 6020° 74 72 75 77 75 72 67 59 5925° 74 72 77 75 73 71 66 59 5830° 78 75 78 78 76 73 69 64 6035° 81 77 79 81 78 75 70 67 6240° 74 76 73 75 73 70 65 61 57Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 69 77 69 78 76 71 65 56 5915° 68 75 70 75 73 69 64 55 5720° 72 78 77 78 76 73 68 60 6025° 72 78 79 76 74 72 67 60 5930° 74 79 78 77 75 72 68 63 5935° 76 80 78 79 76 73 68 65 6140° 68 71 70 75 74 71 68 65 57Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.162 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data800 Ø 12 rpsHub Ø 250Blades 7Hub Ø 250Blades 14120160100140120801006080Static Pressure (Pa)4020010° 15°20° 25° 30° 35°40°Static Pressure (Pa)604020010° 15°20° 25° 30°35° 40°0 2 4 6 8Volume (m 3 /s)0 2 4 6 8Volume (m 3 /s)Impeller Power, kW0.90.80.70.60.50.40.30.20.1010° 15° 20°25°30°35°40°0 2 4 6 8Impeller Power, kW1.41.210.80.60.40.2010°15°20°25° 30° 35°40°0 2 4 6 8Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 67 63 61 77 76 72 68 61 5915° 66 62 62 74 74 70 66 61 5720° 65 61 63 72 71 68 65 60 5525° 63 60 63 69 69 66 64 59 5330° 65 62 65 70 70 67 64 60 5435° 67 64 66 72 71 68 65 62 5540° 66 63 65 70 69 67 64 60 53Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 67 72 64 80 79 75 71 64 6215° 66 71 65 77 77 73 69 64 6020° 68 72 70 78 77 74 71 66 6025° 69 74 73 78 78 75 73 68 6130° 68 73 72 77 76 74 71 67 6035° 73 78 77 81 80 78 75 71 6440° 73 78 76 80 79 77 74 70 64Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 163


FANSCATALOGUEAdjustable Pitch Axial Performance Data800 Ø 12 rpsHub Ø 255Blades 6Hub Ø 255Blades 12120200180100160801401206010080Static Pressure (Pa)402005°10°15° 20° 25°30°Static Pressure (Pa)60402005° 10° 15° 20° 25° 30° 35°0 2 4 6Volume (m 3 /s)0 2 4 6 8Volume (m 3 /s)0.70.630°1.2135°Impeller Power, kW0.50.40.30.20.105°10°15°20°25°Impeller Power, kW0.80.60.40.205°10°15°20°25°30°0 1 2 3 4 5 60 2 4 6 8Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 76 77 71 69 70 69 64 55 5410° 75 76 70 68 69 68 63 54 5315° 74 75 69 67 68 67 62 53 5220° 75 76 70 68 69 68 63 54 5325° 77 78 72 70 71 70 65 56 5530° 79 80 74 72 73 72 67 58 57Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 78 76 76 72 75 72 67 56 5810° 78 76 76 72 75 72 67 56 5815° 79 77 77 73 76 73 68 57 5920° 81 79 79 75 78 75 70 59 6125° 82 80 80 76 79 76 71 60 6230° 83 81 81 77 80 77 72 61 6335° 86 84 84 80 83 80 75 64 66Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.164 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data800 Ø 12 rpsHub Ø 400Blades 4Hub Ø 400Blades 8120180100160140801206010080Static Pressure (Pa)402000°5° 10°15°20°25° 30°35°Static Pressure (Pa)60402000°5° 10° 15° 20°25° 30° 35°0 2 4 6 8Volume (m 3 /s)0 2 4 6 8 10Volume (m 3 /s)Impeller Power, kW1.61.41.210.80.60.40.200°5° 10° 15°20°25°30°35°Impeller Power, kW21.81.61.41.210.80.60.40.200°5°10°15°20°25°30°35°0 2 4 6 80 2 4 6 8 10Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 64 73 71 70 66 61 57 50 515° 63 72 70 69 65 60 56 49 5010° 62 71 69 68 64 59 55 48 4915° 62 71 69 68 64 59 55 48 4920° 62 71 69 68 64 59 55 48 4925° 63 72 70 69 65 60 56 49 5030° 63 72 70 69 65 60 56 49 5035° 64 73 71 70 66 61 57 50 51Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 67 76 74 73 69 64 60 53 545° 66 75 73 72 68 63 59 52 5310° 65 74 72 71 67 62 58 51 5215° 65 74 72 71 67 62 58 51 5220° 65 74 72 71 67 62 58 51 5225° 66 75 73 72 68 63 59 52 5330° 66 75 73 72 68 63 59 52 5335° 67 76 74 73 69 64 60 53 54Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 165


FANSCATALOGUEAdjustable Pitch Axial Performance Data800 Ø 12 rpsHub Ø 400Blades 12Hub Ø 400Blades 1616020014018012016014010012080100Static Pressure (Pa)60402000°5° 10° 15° 20° 25°30° 35°Static Pressure (Pa)8060402000° 5° 10°15° 20° 25° 30° 35°0 2 4 6 8 10Volume (m 3 /s)0 2 4 6 8 10Volume (m 3 /s)2.52.5235°235°1.530°1.530°Impeller Power, kW10.500°5° 10° 15°20°25°0 2 4 6 8 10Impeller Power, kW10.500° 5° 10° 15°20°25°0 2 4 6 8 10Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 68 73 76 74 71 66 62 55 555° 67 72 75 73 70 65 61 54 5410° 66 71 74 72 69 64 60 53 5315° 66 71 74 72 69 64 60 53 5320° 66 71 74 72 69 64 60 53 5325° 66 71 74 72 69 64 60 53 5330° 67 72 75 73 70 65 61 54 5435° 67 72 75 73 70 65 61 54 54Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 69 70 78 76 73 69 64 57 575° 68 69 77 75 72 68 63 56 5610° 67 68 76 74 71 67 62 55 5515° 66 67 75 73 70 66 61 54 5420° 67 68 76 74 71 67 62 55 5525° 67 68 76 74 71 67 62 55 5530° 67 68 76 74 71 67 62 55 5535° 68 69 77 75 72 68 63 56 56Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.166 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 167


FANSCATALOGUEAdjustable Pitch Axial Performance Data900 Ø 24 rpsHub Ø 250Blades 7Hub Ø 250Blades 14600800500700600400500300400Static Pressure (Pa)200100010°15°20°25° 30° 35°40°Static Pressure (Pa)300200100010°15°20° 25°30° 35° 40°0 5 10 15 20Volume (m 3 /s)0 5 10 15 20Volume (m 3 /s)122010835°40°1816141235°40°Impeller Power, kW642015°10°20°25°30°Impeller Power, kW108642015°10°20°25°30°0 5 10 15 200 5 10 15 20Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 83 85 80 96 95 91 86 80 7815° 82 84 81 93 93 89 85 80 7620° 81 83 82 91 90 87 84 79 7425° 79 82 82 88 88 85 82 78 7230° 81 84 84 89 89 86 83 79 7335° 83 86 85 91 90 87 84 80 7440° 85 88 87 92 91 88 85 82 75Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 86 85 89 99 98 94 89 83 8115° 85 84 90 96 96 92 88 83 7920° 84 83 91 94 93 90 87 82 7725° 82 82 91 91 91 88 85 81 7530° 84 84 93 92 92 89 86 82 7635° 86 86 94 94 93 90 87 83 7740° 88 88 96 95 94 91 88 85 78Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.168 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data900 Ø 24 rpsHub Ø 255Blades 6Hub Ø 255Blades 12600800500700600400500300400Static Pressure (Pa)20010005° 10° 15° 20° 25° 30°Static Pressure (Pa)30020010005°10° 15° 20° 25° 30° 35°0 5 10 15 20Volume (m 3 /s)0 5 10 15 20 25Volume (m 3 /s)1018Impeller Power, kW98765432105°10°15°20°25°30°0 5 10 15 20Impeller Power, kW16141210864205°10°15°20°25°30°35°0 5 10 15 20 25Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 96 97 92 91 92 90 85 77 7610° 95 96 91 90 91 89 84 76 7515° 94 95 90 89 90 88 83 75 7420° 94 95 90 89 90 88 83 75 7425° 96 97 92 91 92 90 85 77 7630° 99 100 95 94 95 93 88 80 79Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 99 97 97 94 96 93 88 78 7910° 99 97 97 94 96 93 88 78 7915° 99 97 97 94 96 93 88 78 7920° 101 99 99 96 98 95 90 80 8125° 102 100 100 97 99 96 91 81 8230° 104 102 102 99 101 98 93 83 8435° 107 105 105 102 104 101 96 86 87Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 169


FANSCATALOGUEAdjustable Pitch Axial Performance Data900 Ø 24 rpsHub Ø 400Blades 4Hub Ø 400Blades 8500800450700400350600300500250400Static Pressure (Pa)2001501005000° 5° 10° 15°20°25° 30°35°Static Pressure (Pa)30020010000° 5° 10° 15° 20°25° 30°35°0 5 10 15 20 25Volume (m 3 /s)0 5 10 15 20 25Volume (m 3 /s)202518161435°2030°35°1230°1525°Impeller Power, kW10864200°10°5°15°20°25°Impeller Power, kW10500°5°10°15°20°0 5 10 15 20 250 5 10 15 20 25Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 85 94 92 91 87 82 78 71 725° 84 93 91 90 86 81 77 70 7110° 88 97 95 94 90 85 81 74 7515° 83 92 90 89 85 80 76 69 7020° 83 92 90 89 85 80 76 69 7025° 84 93 91 90 86 81 77 70 7130° 84 93 91 90 86 81 77 70 7135° 85 94 92 91 87 82 78 71 72Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 88 97 95 94 90 85 81 74 755° 87 96 94 93 89 84 80 73 7410° 86 95 93 92 88 83 79 72 7315° 86 95 93 92 88 83 79 72 7320° 86 95 93 92 88 83 79 72 7325° 87 96 94 93 89 84 80 73 7430° 87 96 94 93 89 84 80 73 7435° 88 97 95 94 90 85 81 74 75Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.170 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data900 Ø 24 rpsHub Ø 400Blades 12Hub Ø 400Blades 16800900700800600700500600400500400Static Pressure (Pa)30020010000°5° 10°15° 20° 25°30° 35°Static Pressure (Pa)30020010000°5°10°15° 20° 25° 30° 35°0 5 10 15 20 25Volume (m 3 /s)0 5 10 15 20 25Volume (m 3 /s)30252030°35°30252030°35°Impeller Power, kW1510500°5°10°15°20°25°Impeller Power, kW1510500° 5° 10°15°20°25°0 5 10 15 20 250 5 10 15 20 25Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 89 94 97 95 92 87 83 76 765° 88 93 96 94 91 86 82 75 7510° 87 92 95 93 90 85 81 74 7415° 87 92 95 93 90 85 81 74 7420° 87 92 95 93 90 85 81 74 7425° 87 92 95 93 90 85 81 74 7430° 88 93 96 94 91 86 82 75 7535° 88 93 96 94 91 86 82 75 75Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 90 91 99 97 94 90 85 78 785° 89 90 98 96 93 89 84 77 7710° 88 89 97 95 92 88 83 76 7615° 87 88 96 94 91 87 82 75 7520° 88 89 97 95 92 88 83 76 7625° 88 89 97 95 92 88 83 76 7630° 88 89 97 95 92 88 83 76 7635° 89 90 98 96 93 89 84 77 77Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 171


FANSCATALOGUEAdjustable Pitch Axial Performance Data900 Ø 16 rpsHub Ø 250Blades 7Hub Ø 250Blades 14250300200250150200150100Static Pressure (Pa)50010° 15° 20°25° 30° 35°40°Static Pressure (Pa)10050010°15°20° 25°30° 35° 40°0 5 10 15Volume (m 3 /s)0 5 10 15Volume (m 3 /s)Impeller Power, kW32.521.510.5015°10°20°25°30°35°40°Impeller Power, kW54.543.532.521.510.5015°10°20°25°30°35°40°0 2 4 6 8 10 120 2 4 6 8 10 12 14Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 73 72 70 86 85 81 77 70 6815° 72 71 71 84 83 79 75 70 6620° 71 70 72 81 80 77 74 69 6425° 69 69 72 78 78 75 73 68 6230° 71 71 74 79 79 76 74 70 6335° 73 73 76 81 80 78 75 71 6440° 75 75 77 82 81 79 76 72 65Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 76 81 73 89 88 84 80 73 7115° 75 80 74 87 86 82 78 73 6920° 74 79 75 84 83 80 77 72 6725° 72 78 75 81 81 78 76 71 6530° 74 80 77 82 82 79 77 73 6635° 76 82 79 84 83 81 78 74 6740° 78 84 80 85 84 82 79 75 68Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.172 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data900 Ø 16 rpsHub Ø 255Blades 6Hub Ø 255Blades 12250350200300250150200100150Static Pressure (Pa)5005° 10° 15° 20° 25° 30°Static Pressure (Pa)1005005°10°15°20° 25° 30° 35°0 5 10 15Volume (m 3 /s)0 5 10 15Volume (m 3 /s)362.530°535°225°430°Impeller Power, kW1.510.505°10°15°20°Impeller Power, kW32105°10°15°20°25°0 2 4 6 8 10 120 5 10 15Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 86 87 82 81 82 80 75 67 6610° 85 86 81 80 81 79 74 66 6515° 84 85 80 79 80 78 73 65 6420° 85 86 81 80 81 79 74 66 6525° 87 88 83 82 83 81 76 68 6730° 89 90 85 84 85 83 78 70 69Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 89 87 87 84 86 83 78 68 6910° 89 87 87 84 86 83 78 68 6915° 89 87 87 84 86 83 78 68 6920° 91 89 89 86 88 85 80 70 7125° 93 91 91 88 90 87 82 72 7330° 95 93 93 90 92 89 84 74 7535° 97 95 95 92 94 91 86 76 77Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 173


FANSCATALOGUEAdjustable Pitch Axial Performance Data900 Ø 16 rpsHub Ø 400Blades 4Hub Ø 400Blades 8250350200300250150200100150Static Pressure (Pa)5000° 5° 10° 15°20°25° 30°35°Static Pressure (Pa)1005000° 5° 10° 15° 20° 25° 30° 35°0 5 10 15Volume (m 3 /s)0 5 10 15Volume (m 3 /s)68Impeller Power, kW5432100°5°10°15°20°25°30°35°Impeller Power, kW765432100°5°10°15°20°25°30°35°0 5 10 150 5 10 15Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 76 85 83 82 78 73 69 62 635° 74 83 81 80 76 71 67 60 6110° 79 88 86 85 81 76 72 65 6615° 73 82 80 79 75 70 66 59 6020° 74 83 81 80 76 71 67 60 6125° 74 83 81 80 76 71 67 60 6130° 74 83 81 80 76 71 67 60 6135° 75 84 82 81 77 72 68 61 62Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 79 88 86 85 81 76 72 65 665° 77 86 84 83 79 74 70 63 6410° 77 86 84 83 79 74 70 63 6415° 76 85 83 82 78 73 69 62 6320° 77 86 84 83 79 74 70 63 6425° 77 86 84 83 79 74 70 63 6430° 77 86 84 83 79 74 70 63 6435° 78 87 85 84 80 75 71 64 65Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.174 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data900 Ø 16 rpsHub Ø 400Blades 12Hub Ø 400Blades 16350400300350250300200250200Static Pressure (Pa)1501005000°5° 10° 15° 20° 25°30° 35°Static Pressure (Pa)1501005000° 5° 10° 15° 20° 25° 30° 35°0 5 10 15 20Volume (m 3 /s)0 5 10 15 20Volume (m 3 /s)8735°9835°Impeller Power, kW65432100° 5° 10°15°20°25°30°0 5 10 15 20Impeller Power, kW765432100° 5° 10°15°20°25°30°0 5 10 15 20Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 79 84 87 85 82 77 73 66 665° 78 83 86 84 81 76 72 65 6510° 78 83 86 84 81 76 72 65 6515° 77 82 85 83 80 75 71 64 6420° 77 82 85 83 80 75 71 64 6425° 78 83 86 84 81 76 72 65 6530° 78 83 86 84 81 76 72 65 6535° 78 83 86 84 81 76 72 65 65Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 80 81 89 87 84 80 75 68 685° 79 80 88 86 83 79 74 67 6710° 79 80 88 86 83 79 74 67 6715° 78 79 87 85 82 78 73 66 6620° 78 79 87 85 82 78 73 66 6625° 78 79 87 85 82 78 73 66 6630° 78 79 87 85 82 78 73 66 6635° 79 80 88 86 83 79 74 67 67Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 175


FANSCATALOGUEAdjustable Pitch Axial Performance Data900 Ø 12 rpsHub Ø 250Blades 7Hub Ø 250Blades 14140180120160140100120801006080Static Pressure (Pa)4020010°15°20°25° 30° 35° 40°Static Pressure (Pa)604020010°15°20° 25°30° 35° 40°0 2 4 6 8 10Volume (m 3 /s)0 2 4 6 8 10Volume (m 3 /s)Impeller Power, kW1.41.210.80.60.40.2015°10°20°25°30°35°40°Impeller Power, kW2.521.510.5015°10°20°25°30°35°40°0 2 4 6 8 100 2 4 6 8 10Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 69 65 63 79 78 74 70 63 6115° 68 64 64 76 76 72 68 63 5920° 67 63 65 74 73 70 67 62 5725° 65 62 65 71 71 68 66 61 5530° 67 64 67 72 72 69 67 62 5635° 69 66 68 74 73 70 68 64 5740° 71 68 70 75 74 72 68 65 58Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 69 74 66 82 81 77 73 66 6415° 68 73 67 79 79 75 71 66 6220° 67 72 68 77 76 73 70 65 6025° 65 71 68 74 74 71 69 64 5830° 67 73 70 75 75 72 70 65 5935° 69 75 71 77 76 73 71 67 6040° 71 77 73 78 77 75 71 68 61Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.176 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data900 Ø 12 rpsHub Ø 255Blades 6Hub Ø 255Blades 12140200120180160100140801201006080Static Pressure (Pa)402005° 10° 15° 20° 25° 30°Static Pressure (Pa)60402005° 10° 15° 20° 25° 30° 35°0 2 4 6 8 10Volume (m 3 /s)0 5 10 15Volume (m 3 /s)1.22.5130°235°0.825°1.530°Impeller Power, kW0.60.40.205°10°15°20°Impeller Power, kW10.505°10°15°20°25°0 2 4 6 8 100 2 4 6 8 10 12Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 79 80 75 74 75 73 68 60 5910° 78 79 74 73 74 72 67 59 5815° 77 78 73 72 73 71 66 58 5720° 78 79 74 73 74 72 67 59 5825° 80 81 76 75 76 74 69 61 6030° 82 83 78 77 78 76 71 63 62Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 82 80 80 77 79 76 71 61 6210° 82 80 80 77 79 76 71 61 6215° 83 81 81 78 80 77 72 62 6320° 85 83 83 80 82 79 74 64 6525° 86 84 84 81 83 80 75 65 6630° 88 86 86 83 85 82 77 67 6835° 90 88 88 85 87 84 79 69 70Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 177


FANSCATALOGUEAdjustable Pitch Axial Performance Data900 Ø 12 rpsHub Ø 400Blades 4Hub Ø 400Blades 8140200120180160100140801201006080Static Pressure (Pa)402000° 5° 10° 15°20°25° 30° 35°Static Pressure (Pa)60402000° 5° 10° 15° 20°25° 30°35°0 5 10 15Volume (m 3 /s)0 5 10 15Volume (m 3 /s)2.5235°32.530°35°1.530°225°Impeller Power, kW10.500°10°5°15°20°25°Impeller Power, kW1.510.500°5°10°15°20°0 2 4 6 8 10 120 2 4 6 8 10 12Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 69 78 76 75 71 66 62 55 565° 68 77 75 74 70 65 61 54 5510° 72 81 79 78 74 69 65 58 5915° 66 75 73 72 68 63 59 52 5320° 67 76 74 73 69 64 60 53 5425° 67 76 74 73 69 64 60 53 5430° 68 77 75 74 70 65 61 54 5535° 68 77 75 74 70 65 61 54 55Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 72 81 79 78 74 69 65 58 595° 71 80 78 77 73 68 64 57 5810° 70 79 77 76 72 67 63 56 5715° 69 78 76 75 71 66 62 55 5620° 70 79 77 76 72 67 63 56 5725° 70 79 77 76 72 67 63 56 5730° 71 80 78 77 73 68 64 57 5835° 71 80 78 77 73 68 64 57 58Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.178 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data900 Ø 12 rpsHub Ø 400Blades 12Hub Ø 400Blades 1620025018016020014012015010080100Static Pressure (Pa)60402000° 5° 10° 15° 20° 25°30° 35°Static Pressure (Pa)5000° 5° 10° 15° 20° 25° 30° 35°0 5 10 15Volume (m 3 /s)0 5 10 15Volume (m 3 /s)3.54335°3.535°Impeller Power, kW2.521.510.500°5°10°15°20°25°30°Impeller Power, kW32.521.510.500°5°10°15°20°25°30°0 2 4 6 8 10 120 2 4 6 8 10 12Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 72 77 80 78 75 70 66 59 595° 72 77 80 78 75 70 66 59 5910° 71 76 79 77 74 69 65 58 5815° 70 75 78 76 73 68 64 57 5720° 70 75 78 76 73 68 64 57 5725° 71 76 79 77 74 69 65 58 5830° 71 76 79 77 74 69 65 58 5835° 72 77 80 78 75 70 66 59 59Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 73 74 82 80 77 73 68 61 615° 73 74 82 80 77 73 68 61 6110° 72 73 81 79 76 72 67 60 6015° 71 72 80 78 75 71 66 59 5920° 71 72 80 78 75 71 66 59 5925° 71 72 80 78 75 71 66 59 5930° 72 73 81 79 76 72 67 60 6035° 72 73 81 79 76 72 67 60 60Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 179


FANSCATALOGUEAdjustable Pitch Axial Performance Data1000 Ø 24 rpsHub Ø 250Blades 7Hub Ø 250Blades 14600800500700600400500300400Static Pressure (Pa)200100010°15°20° 25° 30° 35° 40°Static Pressure (Pa)300200100010°15°20° 25° 30°35° 40°0 5 10 15 20 25Volume (m 3 /s)0 10 20 30Volume (m 3 /s)Impeller Power, kW161412108642015°10°20°25°30°35°40°Impeller Power, kW252015105010° 15° 20°25°30°35°40°0 5 10 15 20 250 5 10 15 20 25 30Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 77 78 74 90 89 85 80 74 7315° 79 80 78 90 89 86 82 76 7320° 83 85 84 93 93 90 87 82 7625° 82 84 85 91 91 88 85 81 7530° 84 87 87 92 92 89 86 82 7635° 86 89 88 93 93 90 87 83 7740° 91 90 95 91 89 87 81 76 74Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 89 87 92 102 101 97 92 86 8415° 90 88 93 103 102 98 93 87 8520° 91 90 98 101 100 97 94 89 8425° 92 92 101 101 101 98 96 91 8530° 91 91 100 100 99 97 94 90 8335° 93 93 102 101 100 98 95 91 8540° 92 92 100 99 98 96 93 89 83Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.180 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1000 Ø 24 rpsHub Ø 255Blades 6Hub Ø 255Blades 12600900500800700400600300500400Static Pressure (Pa)20010005° 10° 15° 20° 25° 30°Static Pressure (Pa)30020010005° 10° 15°20° 25° 30° 35°0 5 10 15 20 25Volume (m 3 /s)0 10 20 30Volume (m 3 /s)163014121025°30°252030°35°Impeller Power, kW864205°10°15°20°Impeller Power, kW1510505°15°10°20°25°0 5 10 15 20 250 5 10 15 20 25 30Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 99 100 96 94 95 92 88 81 7910° 98 99 95 93 94 91 87 80 7815° 98 99 95 93 94 91 87 80 7820° 98 99 95 93 94 91 87 80 7825° 100 101 97 95 96 93 89 82 8030° 103 104 100 98 99 96 92 85 83Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 100 97 98 95 98 94 89 80 8110° 99 96 97 94 97 93 88 79 8015° 101 98 99 96 99 95 90 81 8220° 101 98 99 96 99 95 90 81 8225° 102 99 100 97 100 96 91 82 8330° 110 107 108 105 108 104 99 90 9135° 110 107 108 105 108 104 99 90 91Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 181


FANSCATALOGUEAdjustable Pitch Axial Performance Data1000 Ø 24 rpsHub Ø 330Blades 8Hub Ø 330Blades 16600800500700600400500300400Static Pressure (Pa)200100015° 20° 25° 30° 35°Static Pressure (Pa)300200100015° 20°25° 30° 35°0 5 10 15 20 25Volume (m 3 /s)0 10 20 30Volume (m 3 /s)1816141230°35°35302530°35°Impeller Power, kW108642015°20°25°0 5 10 15 20 25Impeller Power, kW2015105015° 20° 25°0 5 10 15 20 25 30Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 103 103 100 99 97 96 91 80 8220° 103 103 100 99 97 96 91 80 8225° 104 104 101 100 98 97 92 81 8330° 105 105 102 101 99 98 93 82 8435° 106 106 103 102 100 99 94 83 85Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 101 101 103 103 102 101 97 85 8720° 101 101 103 103 102 101 97 85 8725° 102 102 104 104 103 102 98 86 8830° 102 102 104 104 103 102 98 86 8835° 104 104 106 106 105 104 100 88 90Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.182 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1000 Ø 24 rpsHub Ø 400Blades 4Hub Ø 400Blades 8600900500800700400600300500400Static Pressure (Pa)20010000°5° 10° 15°20°25° 30°35°Static Pressure (Pa)30020010000°5°10° 15° 20°25° 30° 35°0 10 20 30Volume (m 3 /s)0 10 20 30Volume (m 3 /s)Impeller Power, kW25201510500°5°10°15°20°25°30°35°Impeller Power, kW40353025201510500°5°10°15°20°25°30°35°0 5 10 15 20 25 300 5 10 15 20 25 30Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 89 98 96 95 91 86 82 75 765° 88 97 95 94 90 85 81 74 7510° 87 96 94 93 89 84 80 73 7415° 87 96 94 93 89 84 80 73 7420° 87 96 94 93 89 84 80 73 7425° 88 97 95 94 90 85 81 74 7530° 88 97 95 94 90 85 81 74 7535° 89 98 96 95 91 86 82 75 76Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 92 101 99 98 94 89 85 78 795° 91 100 98 97 93 88 84 77 7810° 90 99 97 96 92 87 83 76 7715° 90 99 97 96 92 87 83 76 7720° 90 99 97 96 92 87 83 76 7725° 91 100 98 97 93 88 84 77 7830° 91 100 98 97 93 88 84 77 7835° 92 101 99 98 94 89 85 78 79Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 183


FANSCATALOGUEAdjustable Pitch Axial Performance Data1000 Ø 24 rpsHub Ø 400Blades 12Hub Ø 400Blades 16100012009008001000700800600500600400Static Pressure (Pa)30020010000°5° 10° 15° 20° 25°30° 35°Static Pressure (Pa)40020000°5° 10° 15° 20° 25°30°35°0 10 20 30 40Volume (m 3 /s)0 10 20 30 40Volume (m 3 /s)4550Impeller Power, kW40353025201510500° 5° 10°15°20°25°30°35°Impeller Power, kW4540353025201510500° 5° 10°15°20°25°30°35°0 10 20 30 400 10 20 30 40Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 93 98 101 99 96 91 87 80 805° 92 97 100 98 95 90 86 79 7910° 91 96 99 97 94 89 85 78 7815° 91 96 99 97 94 89 85 78 7820° 91 96 99 97 94 89 85 78 7825° 91 96 99 97 94 89 85 78 7830° 92 97 100 98 95 90 86 79 7935° 92 97 100 98 95 90 86 79 79Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 94 95 103 101 98 94 89 82 825° 93 94 102 100 97 93 88 81 8110° 93 94 102 100 97 93 88 81 8115° 91 92 100 98 95 91 86 79 7920° 92 93 101 99 96 92 87 80 8025° 92 93 101 99 96 92 87 80 8030° 92 93 101 99 96 92 87 80 8035° 93 94 102 100 97 93 88 81 81Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.184 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1000 Ø 16 rpsHub Ø 250Blades 7Hub Ø 250Blades 14250350200300250150200100150Static Pressure (Pa)50010°15°20° 25° 30°35° 40°Static Pressure (Pa)10050010°15°20° 25° 30° 35° 40°0 5 10 15 20Volume (m 3 /s)0 5 10 15 20Volume (m 3 /s)4.543.5335°40°76535°40°Impeller Power, kW2.521.510.5015°10°20°25°30°Impeller Power, kW4321010° 15° 20°25°30°0 5 10 15 200 5 10 15 20Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 71 72 68 84 83 79 74 68 6715° 73 74 72 84 83 80 76 70 6620° 73 73 75 84 83 80 77 72 6725° 74 77 77 83 83 80 78 73 6730° 76 79 79 85 84 82 79 75 6835° 78 81 81 86 85 83 80 76 6940° 78 78 80 85 84 81 78 75 68Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 79 84 76 92 91 87 82 76 7415° 79 82 77 92 91 87 82 76 7420° 76 82 78 87 86 83 80 75 7025° 79 84 83 88 88 85 83 78 7230° 81 86 85 90 89 87 84 80 7335° 85 90 89 93 92 90 87 83 7640° 85 90 88 92 91 89 86 82 75Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 185


FANSCATALOGUEAdjustable Pitch Axial Performance Data1000 Ø 16 rpsHub Ø 255Blades 6Hub Ø 255Blades 12300400250350300200250150200Static Pressure (Pa)1005005° 10° 15° 20° 25° 30°Static Pressure (Pa)1501005005° 10° 15°20° 25° 30° 35°0 5 10 15 20Volume (m 3 /s)0 5 10 15 20Volume (m 3 /s)58Impeller Power, kW4.543.532.521.510.505°10°15°20°25°30°Impeller Power, kW765432105°10°15°20°25°30°35°0 5 10 15 200 5 10 15 20Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 90 91 87 85 86 83 79 72 7010° 89 90 86 84 85 82 78 71 6915° 88 89 85 83 84 81 77 70 6820° 89 90 86 84 85 82 78 71 6925° 91 92 88 86 87 84 80 73 7130° 94 95 91 89 90 87 83 76 74Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 90 87 88 85 88 84 79 70 7110° 90 87 88 85 88 84 79 70 7115° 91 88 89 86 89 85 80 71 7220° 92 89 90 87 90 86 81 72 7325° 92 89 90 87 90 86 81 72 7330° 100 97 98 95 98 94 89 80 8135° 100 97 98 95 98 94 89 80 81Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.186 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1000 Ø 16 rpsHub Ø 330Blades 8Hub Ø 330Blades 16250350200300250150200100150Static Pressure (Pa)50015° 20° 25° 30° 35°Static Pressure (Pa)10050015° 20°25° 30° 35°0 5 10 15 20Volume (m 3 /s)0 5 10 15 20Volume (m 3 /s)610535°9835°Impeller Power, kW4321015°20°25°30°0 5 10 15 20Impeller Power, kW7654321020°15°25°30°0 5 10 15 20Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 93 93 90 89 87 86 81 70 7220° 93 93 90 89 87 86 81 70 7225° 94 94 91 90 88 87 82 71 7330° 95 95 92 91 89 88 83 72 7435° 96 96 93 92 90 89 84 73 75Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 91 91 93 93 92 91 87 75 7720° 91 91 93 93 92 91 87 75 7725° 92 92 94 94 93 92 88 76 7830° 92 92 94 94 93 92 88 76 7835° 94 94 96 96 95 94 90 78 80Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 187


FANSCATALOGUEAdjustable Pitch Axial Performance Data1000 Ø 16 rpsHub Ø 400Blades 4Hub Ø 400Blades 8250400350200300150250200Static Pressure (Pa)1005000°5° 10°15°20°25° 30°35°Static Pressure (Pa)1501005000°5°10° 15° 20°25° 30° 35°0 5 10 15 20Volume (m 3 /s)0 5 10 15 20Volume (m 3 /s)81276530°35°10830°35°Impeller Power, kW432100°5°10°15°20°25°Impeller Power, kW64200°5°10°15°20°25°0 5 10 15 200 5 10 15 20Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 80 89 87 86 82 77 73 66 675° 79 88 86 85 81 76 72 65 6610° 78 87 85 84 80 75 71 64 6515° 77 86 84 83 79 74 70 63 6420° 78 87 85 84 80 75 71 64 6525° 78 87 85 84 80 75 71 64 6530° 78 87 85 84 80 75 71 64 6535° 79 88 86 85 81 76 72 65 66Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 83 92 90 89 85 80 76 69 705° 82 91 89 88 84 79 75 68 6910° 80 89 87 86 82 77 73 66 6715° 80 89 87 86 82 77 73 66 6720° 81 90 88 87 83 78 74 67 6825° 81 90 88 87 83 78 74 67 6830° 81 90 88 87 83 78 74 67 6835° 82 91 89 88 84 79 75 68 69Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.188 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1000 Ø 16 rpsHub Ø 400Blades 12Hub Ø 400Blades 16450500400450350400300350250200300250200Static Pressure (Pa)1501005000°5° 10° 15° 20° 25°30°35°Static Pressure (Pa)1501005000°5° 10° 15° 20° 25°30°35°0 5 10 15 20 25Volume (m 3 /s)0 5 10 15 20 25Volume (m 3 /s)141235°141235°Impeller Power, kW10864200°5°10°15°20°25°30°Impeller Power, kW10864200°10°5°15°20°25°30°0 5 10 15 20 250 5 10 15 20 25Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 83 88 91 89 86 81 77 70 705° 83 88 91 89 86 81 77 70 7010° 82 87 90 88 85 80 76 69 6915° 81 86 89 87 84 79 75 68 6820° 81 86 89 87 84 79 75 68 6825° 82 87 90 88 85 80 76 69 6930° 82 87 90 88 85 80 76 69 6935° 83 88 91 89 86 81 77 70 70Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 84 85 93 91 88 84 79 72 725° 84 85 93 91 88 84 79 72 7210° 83 84 92 90 87 83 78 71 7115° 82 83 91 89 86 82 77 70 7020° 82 83 91 89 86 82 77 70 7025° 82 83 91 89 86 82 77 70 7030° 82 83 91 89 86 82 77 70 7035° 83 84 92 90 87 83 78 71 71Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 189


FANSCATALOGUEAdjustable Pitch Axial Performance Data1000 Ø 12 rpsHub Ø 250Blades 7Hub Ø 250Blades 1416020014018012016014010012080100Static Pressure (Pa)604020010°15°20° 25° 30°35° 40°Static Pressure (Pa)80604020010°15°20° 25° 30°35° 40°0 5 10 15Volume (m 3 /s)0 5 10 15Volume (m 3 /s)23.5Impeller Power, kW1.81.61.41.210.80.60.40.2015°10°20°25°30°35°40°Impeller Power, kW32.521.510.5010° 15° 20°25°30°35°40°0 2 4 6 8 10 120 2 4 6 8 10 12 14Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 68 63 62 78 77 73 68 62 6015° 69 64 65 77 76 73 69 63 6020° 69 66 67 77 76 73 70 65 6025° 72 69 72 78 78 75 73 68 6130° 71 68 71 77 76 74 71 67 6035° 74 71 74 79 78 76 73 69 6240° 74 71 73 78 77 74 71 67 61Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 72 77 69 85 84 80 75 69 6715° 73 76 71 86 85 81 76 70 6820° 69 75 70 80 79 76 73 68 6325° 71 76 75 80 80 77 75 70 6430° 74 79 78 83 82 80 77 73 6635° 78 83 82 86 85 83 80 76 7040° 78 83 81 85 84 82 79 75 69Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.190 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1000 Ø 12 rpsHub Ø 255Blades 6Hub Ø 255Blades 1216025014012020010015080Static Pressure (Pa)60402005° 10° 15° 20° 25° 30°Static Pressure (Pa)1005005° 10° 15°20° 25° 30° 35°0 5 10 15Volume (m 3 /s)0 5 10 15Volume (m 3 /s)23.5Impeller Power, kW1.81.61.41.210.80.60.40.205°10°15°20°25°30°Impeller Power, kW32.521.510.505°10°15°20°25°30°35°0 2 4 6 8 10 120 5 10 15Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 83 84 80 78 79 76 72 65 6310° 82 83 79 77 78 75 71 64 6215° 81 82 78 76 77 74 70 63 6120° 82 83 79 77 78 75 71 64 6225° 84 85 81 79 80 77 73 66 6430° 87 88 84 82 83 80 76 69 67Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 83 80 81 78 81 77 72 63 6410° 83 80 81 78 81 77 72 63 6415° 84 81 82 79 82 78 73 64 6520° 85 82 83 80 83 79 74 65 6625° 86 83 84 81 84 80 75 66 6730° 93 90 91 88 91 87 82 73 7435° 93 90 91 88 91 87 82 73 74Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 191


FANSCATALOGUEAdjustable Pitch Axial Performance Data1000 Ø 12 rpsHub Ø 330Blades 8Hub Ø 330Blades 16140200120180160100140801201006080Static Pressure (Pa)4020015° 20° 25° 30° 35°Static Pressure (Pa)604020015° 20°25° 30° 35°0 5 10 15Volume (m 3 /s)0 5 10 15Volume (m 3 /s)2.54.5Impeller Power, kW21.510.5015°20°25°30°35°0 2 4 6 8 10 12Impeller Power, kW43.532.521.510.5015° 20° 25°30°35°0 2 4 6 8 10 12 14Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 86 86 83 82 80 79 74 63 6520° 86 86 83 82 80 79 74 63 6525° 87 87 84 83 81 80 75 64 6630° 88 88 85 84 82 81 76 65 6735° 89 89 86 85 83 82 77 66 68Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 84 84 86 86 85 84 80 68 7020° 84 84 86 86 85 84 80 68 7025° 85 85 87 87 86 85 81 69 7130° 85 85 87 87 86 85 81 69 7135° 87 87 89 89 88 87 83 71 73Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.192 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1000 Ø 12 rpsHub Ø 400Blades 4Hub Ø 400Blades 81402501202001008015060100Static Pressure (Pa)402000°5° 10° 15° 20°25° 30°35°Static Pressure (Pa)5000°5°10° 15° 20°25° 30° 35°0 5 10 15Volume (m 3 /s)0 5 10 15Volume (m 3 /s)3.55Impeller Power, kW32.521.510.500°5°10°15°20°25°30°35°Impeller Power, kW4.543.532.521.510.500°5°10°15°20°25°30°35°0 2 4 6 8 10 12 140 5 10 15Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 73 82 80 79 75 70 66 59 605° 72 81 79 78 74 69 65 58 5910° 71 80 78 77 73 68 64 57 5815° 71 80 78 77 73 68 64 57 5820° 71 80 78 77 73 68 64 57 5825° 71 80 78 77 73 68 64 57 5830° 72 81 79 78 74 69 65 58 5935° 72 81 79 78 74 69 65 58 59Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 76 85 83 82 78 73 69 62 635° 75 84 82 81 77 72 68 61 6210° 73 82 80 79 75 70 66 59 6015° 74 83 81 80 76 71 67 60 6120° 74 83 81 80 76 71 67 60 6125° 74 83 81 80 76 71 67 60 6130° 75 84 82 81 77 72 68 61 6235° 75 84 82 81 77 72 68 61 62Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 193


FANSCATALOGUEAdjustable Pitch Axial Performance Data1000 Ø 12 rpsHub Ø 400Blades 12Hub Ø 400Blades 16250300200250150200150100Static Pressure (Pa)5000°5° 10° 15° 20° 25°30°35°Static Pressure (Pa)1005000°5° 10° 15° 20° 25°30°35°0 5 10 15 20Volume (m 3 /s)0 5 10 15 20Volume (m 3 /s)6535°6535°Impeller Power, kW432100° 5° 10°15°20°25°30°Impeller Power, kW432100° 5° 10°15°20°25°30°0 5 10 15 200 5 10 15 20Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 77 82 85 83 80 75 71 64 645° 76 81 84 82 79 74 70 63 6310° 75 80 83 81 78 73 69 62 6215° 74 79 82 80 77 72 68 61 6120° 74 79 82 80 77 72 68 61 6125° 75 80 83 81 78 73 69 62 6230° 75 80 83 81 78 73 69 62 6235° 76 81 84 82 79 74 70 63 63Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 77 78 86 84 81 77 72 65 655° 77 78 86 84 81 77 72 65 6510° 76 77 85 83 80 76 71 64 6415° 75 76 84 82 79 75 70 63 6320° 75 76 84 82 79 75 70 63 6325° 75 76 84 82 79 75 70 63 6330° 76 77 85 83 80 76 71 64 6435° 76 77 85 83 80 76 71 64 64Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.194 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 195


FANSCATALOGUEAdjustable Pitch Axial Performance Data1120 Ø 24 rpsHub Ø 255Blades 6Hub Ø 255Blades 1280012007001000600500800400600Static Pressure (Pa)30020010005° 10° 15° 20° 25° 30°Static Pressure (Pa)40020005° 10° 15° 20° 25° 30° 35°0 10 20 30 40Volume (m 3 /s)0 10 20 30 40 50Volume (m 3 /s)30602530°5035°2025°4030°Impeller Power, kW1510505°10°15°20°0 10 20 30 40Impeller Power, kW302010015°10°5°20°25°0 10 20 30 40 50Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 99 101 98 97 97 94 90 83 8110° 99 101 98 97 97 94 90 83 8115° 100 102 99 98 98 95 91 84 8220° 102 104 101 100 100 97 93 86 8425° 104 106 103 102 102 99 95 88 8630° 108 110 107 106 106 103 99 92 90Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 100 101 99 97 98 96 92 86 8210° 100 101 99 97 98 96 92 86 8215° 101 102 100 98 99 97 93 87 8320° 104 105 103 101 102 100 96 90 8625° 107 108 106 104 105 103 99 93 8930° 109 110 108 106 107 105 101 95 9135° 113 114 112 110 111 109 105 99 95Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.196 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1120 Ø 24 rpsHub Ø 330Blades 8Hub Ø 330Blades 16700900600800700500600400500300400Static Pressure ( Pa)200100015° 20° 25°30° 35°Static Pressure ( Pa)300200100015° 20° 25°30° 35°0 10 20 30 40Volume (m 3 /s)0 10 20 30 40Volume (m 3 /s)3050252025°30°35°4540353030°35°Impeller Power, kW15105015°20°0 10 20 30 40Impeller Power, kW252015105015°20°25°0 10 20 30 40Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 101 101 98 97 95 94 89 78 8020° 102 102 99 98 96 95 90 79 8125° 103 103 100 99 97 96 91 80 8230° 105 105 102 101 99 98 93 82 8435° 106 106 103 102 100 99 94 83 85Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 104 104 101 100 98 97 92 81 8320° 104 104 101 100 98 97 92 81 8325° 105 105 102 101 99 98 93 82 8430° 106 106 103 102 100 99 94 83 8535° 107 107 104 103 101 100 95 84 86Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 197


FANSCATALOGUEAdjustable Pitch Axial Performance Data1120 Ø 24 rpsHub Ø 400Blades 4Hub Ø 400Blades 87001000600900800500700400600500300400Static Pressure (Pa)20010000°5° 10° 15° 20°25° 30°35°Static Pressure (Pa)30020010000°5°10° 15° 20° 25° 30°35°0 10 20 30 40Volume (m 3 /s)0 10 20 30 40Volume (m 3 /s)4060Impeller Power, kW353025201510500°5°10°15°20°25°30°35°Impeller Power, kW504030201000°5°10°15°20°25°30°35°0 10 20 30 400 10 20 30 40Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 94 90 97 104 100 96 91 86 845° 112 121 119 118 114 109 105 98 9910° 111 120 118 117 113 108 104 97 9815° 110 119 117 116 112 107 103 96 9720° 110 119 117 116 112 107 103 96 9725° 110 119 117 116 112 107 103 96 9730° 110 119 117 116 112 107 103 96 9735° 111 120 118 117 113 108 104 97 98Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 109 118 116 115 111 106 102 95 965° 115 124 122 121 117 112 108 101 10210° 114 123 121 120 116 111 107 100 10115° 113 122 120 119 115 110 106 99 10020° 113 122 120 119 115 110 106 99 10025° 113 122 120 119 115 110 106 99 10030° 113 122 120 119 115 110 106 99 10035° 114 123 121 120 116 111 107 100 101Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.198 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1120 Ø 24 rpsHub Ø 400Blades 12Hub Ø 400Blades 1612001400100012008001000800600600Static Pressure (Pa)40020000°5° 10° 15° 20° 25°30°35°Static Pressure (Pa)40020000° 5° 10°15° 20° 25° 30°35°0 10 20 30 40 50Volume (m 3 /s)0 10 20 30 40 50Volume (m 3 /s)70806035°7035°Impeller Power, kW504030201000°5°10°15°20°25°30°Impeller Power, kW60504030201000°5°10°15°20°25°30°0 10 20 30 40 500 10 20 30 40 50Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 112 121 119 118 114 109 105 98 995° 116 121 124 122 119 114 110 103 10310° 115 120 123 121 118 113 109 102 10215° 114 119 122 120 117 112 108 101 10120° 114 119 122 120 117 112 108 101 10125° 114 119 122 120 117 112 108 101 10130° 114 119 122 120 117 112 108 101 10135° 114 119 122 120 117 112 108 101 101Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 113 118 121 119 116 111 107 100 1005° 117 118 126 124 121 117 112 105 10510° 116 117 125 123 120 116 111 104 10415° 115 116 124 122 119 115 110 103 10320° 115 116 124 122 119 115 110 103 10325° 114 115 123 121 118 114 109 102 10230° 114 115 123 121 118 114 109 102 10235° 115 116 124 122 119 115 110 103 103Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 199


FANSCATALOGUEAdjustable Pitch Axial Performance Data1120 Ø 16 rpsHub Ø 250Blades 7Hub Ø 250Blades 14300400250350300200250150200Static Pressure (Pa)10050010°15° 20° 25° 30° 35° 40°Static Pressure (Pa)15010050010°15°20° 25° 30°35° 40°0 5 10 15 20 25Volume (m 3 /s)0 10 20 30Volume (m 3 /s)712640°1040°Impeller Power, kW54321010°15°20°25°30°35°Impeller Power, kW8642010°15°20°25°30°35°0 5 10 15 20 250 5 10 15 20 25 30Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 79 77 76 92 90 87 82 76 7415° 77 76 76 89 88 85 81 75 7220° 76 75 77 86 86 83 79 74 6925° 75 74 78 84 83 81 78 74 6730° 76 76 79 85 84 82 79 75 6835° 78 78 81 86 85 83 80 76 6940° 80 80 82 87 87 84 81 77 71Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 82 86 79 95 93 90 85 79 7715° 80 85 79 92 91 88 84 78 7520° 79 84 80 89 89 86 82 77 7225° 78 83 81 87 86 84 81 77 7030° 79 85 82 88 87 85 82 78 7135° 81 87 84 89 88 86 83 79 7240° 83 89 85 90 90 87 84 80 74Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.200 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1120 Ø 16 rpsHub Ø 255Blades 6Hub Ø 255Blades 12350500300450400250350200300250150200Static Pressure (Pa)1005005°10° 15° 20° 25° 30°Static Pressure (Pa)1501005005° 10° 15° 20° 25° 30° 35°0 5 10 15 20 25Volume (m 3 /s)0 10 20 30Volume (m 3 /s)916Impeller Power, kW8765432105°10°15°20°25°30°0 5 10 15 20 25Impeller Power, kW141210864205°15°10°20°25°30°35°0 5 10 15 20 25 30Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 90 92 89 88 88 85 81 74 7210° 89 91 88 87 87 84 80 73 7115° 90 92 89 88 88 85 81 74 7220° 92 94 91 90 90 87 83 76 7425° 95 97 94 93 93 90 86 79 7730° 98 100 97 96 96 93 89 82 80Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 91 92 90 88 89 87 83 77 7310° 90 91 89 87 88 86 82 76 7215° 91 92 90 88 89 87 83 77 7320° 95 96 94 92 93 91 87 81 7725° 97 98 96 94 95 93 89 83 7930° 99 100 98 96 97 95 91 85 8135° 103 104 102 100 101 99 95 89 85Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 201


FANSCATALOGUEAdjustable Pitch Axial Performance Data1120 Ø 16 rpsHub Ø 330Blades 8Hub Ø 330Blades 16300300250250200200150150Static Pressure (Pa)10050015° 20° 25°30° 35°0 5 10 15 20 25Volume (m 3 /s)Static Pressure ( Pa)10050015° 20° 25°30° 35°0 5 10 15 20 25Volume (m 3 /s)99835°835°Impeller Power, kW7654321015°20°25°30°0 5 10 15 20 25Impeller Power, kW7654321015°20°25°30°0 5 10 15 20 25Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 91 91 88 87 85 84 79 68 7020° 92 92 89 88 86 85 80 69 7125° 94 94 91 90 88 87 82 71 7330° 95 95 92 91 89 88 83 72 7435° 97 97 94 93 91 90 85 74 76Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 94 94 91 90 88 87 82 71 7320° 94 94 91 90 88 87 82 71 7325° 95 95 92 91 89 88 83 72 7430° 96 96 93 92 90 89 84 73 7535° 98 98 95 94 92 91 86 75 77Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.202 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1120 Ø 16 rpsHub Ø 400Blades 4Hub Ø 400Blades 8300450250400350200300150250200Static Pressure (Pa)1005000°5° 10°15° 20° 25° 30°35°Static Pressure (Pa)1501005000°5°10° 15° 20°25°30°35°0 5 10 15 20 25Volume (m 3 /s)0 10 20 30Volume (m 3 /s)12181035°161435°830°1230°Impeller Power, kW64200°5°10°15°20°25°Impeller Power, kW10864200°5°10°15°20°25°0 5 10 15 20 250 5 10 15 20 25 30Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 90 99 97 96 92 87 83 76 775° 89 98 96 95 91 86 82 75 7610° 87 96 94 93 89 84 80 73 7415° 88 97 95 94 90 85 81 74 7520° 88 97 95 94 90 85 81 74 7525° 88 97 95 94 90 85 81 74 7530° 88 97 95 94 90 85 81 74 7535° 89 98 96 95 91 86 82 75 76Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 93 102 100 99 95 90 86 79 805° 92 101 99 98 94 89 85 78 7910° 90 99 97 96 92 87 83 76 7715° 91 100 98 97 93 88 84 77 7820° 91 100 98 97 93 88 84 77 7825° 91 100 98 97 93 88 84 77 7830° 91 100 98 97 93 88 84 77 7835° 92 101 99 98 94 89 85 78 79Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 203


FANSCATALOGUEAdjustable Pitch Axial Performance Data1120 Ø 16 rpsHub Ø 400Blades 12Hub Ø 400Blades 16500600450400500350400300250300200Static Pressure (Pa)1501005000°5° 10°15° 20° 25° 30° 35°Static Pressure (Pa)20010000° 5° 10°15° 20° 25° 30°35°0 10 20 30Volume (m 3 /s)0 10 20 30Volume (m 3 /s)Impeller Power, kW201816141210864200°5°10°15°20°25°30°35°Impeller Power, kW25201510500°5°10°15°20°25°30°35°0 5 10 15 20 25 300 5 10 15 20 25 30Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 93 98 101 99 96 91 87 80 805° 93 98 101 99 96 91 87 80 8010° 92 97 100 98 95 90 86 79 7915° 91 96 99 97 94 89 85 78 7820° 91 96 99 97 94 89 85 78 7825° 92 97 100 98 95 90 86 79 7930° 92 97 100 98 95 90 86 79 7935° 93 98 101 99 96 91 87 80 80Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 94 95 103 101 98 94 89 82 825° 94 95 103 101 98 94 89 82 8210° 93 94 102 100 97 93 88 81 8115° 92 93 101 99 96 92 87 80 8020° 92 93 101 99 96 92 87 80 8025° 92 93 101 99 96 92 87 80 8030° 92 93 101 99 96 92 87 80 8035° 93 94 102 100 97 93 88 81 81Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.204 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1120 Ø 12 rpsHub Ø 250Blades 7Hub Ø 250Blades 14120180100160140801206010080Static Pressure (Pa)4020010° 15° 20° 25° 30° 35°40°Static Pressure (Pa)604020010°15°20° 25° 30°35° 40°0 5 10 15 20Volume (m 3 /s)0 5 10 15 20Volume (m 3 /s)Impeller Power, kW1.81.61.41.210.80.60.40.2010°15°20°25°30°35°40°Impeller Power, kW32.521.510.5010°15°20°25°30°35°40°0 5 10 15 200 5 10 15 20Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 75 70 69 85 83 80 75 69 6715° 73 69 69 82 81 78 74 68 6520° 72 68 70 79 79 76 72 67 6225° 71 67 71 77 76 74 71 67 6030° 72 69 72 78 77 75 72 68 6135° 74 71 74 79 78 76 73 69 6240° 76 73 75 80 79 77 74 70 63Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m10° 75 79 72 88 86 83 78 72 7015° 73 78 72 85 84 81 77 71 6820° 72 77 73 82 82 79 75 70 6525° 71 76 74 80 79 77 74 70 6330° 72 78 75 81 80 78 75 71 6435° 74 80 77 82 81 79 76 72 6540° 76 82 78 83 82 80 77 73 66Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 205


FANSCATALOGUEAdjustable Pitch Axial Performance Data1120 Ø 12 rpsHub Ø 255Blades 6Hub Ø 255Blades 1220030018016025014020012010015080Static Pressure (Pa)60402005° 10° 15° 20° 25° 30°Static Pressure (Pa)1005005° 10° 15° 20° 25° 30° 35°0 5 10 15 20Volume (m 3 /s)0 5 10 15 20 25Volume (m 3 /s)3.57330°635°Impeller Power, kW2.521.510.505°10°15°20°25°0 5 10 15 20Impeller Power, kW5432105°15°10°20°25°30°0 5 10 15 20 25Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 83 85 82 81 81 78 74 67 6510° 82 84 81 80 80 77 73 66 6415° 83 85 82 81 81 78 74 67 6520° 85 87 84 83 83 80 76 69 6725° 88 90 87 86 86 83 79 72 7030° 91 93 90 89 89 86 82 75 73Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 84 85 83 81 82 80 76 70 6610° 84 85 83 81 82 80 76 70 6615° 85 86 84 82 83 81 77 71 6720° 88 89 87 85 86 84 80 74 7025° 90 91 89 87 88 86 82 76 7230° 92 93 91 89 90 88 84 78 7435° 96 97 95 93 94 92 88 82 78Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.206 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1120 Ø 12 rpsHub Ø 330Blades 8Hub Ø 330Blades 1616020014018012016014010012080100Static Pressure ( Pa)604020015° 20° 25° 30° 35°Static Pressure ( Pa)80604020015° 20° 25° 30° 35°0 5 10 15 20Volume (m 3 /s)0 5 10 15 20 25Volume (m 3 /s)47Impeller Power, kW3.532.521.510.5015°20°25°30°35°0 5 10 15 20Impeller Power, kW654321015°20°25°30°35°0 5 10 15 20 25Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 85 85 82 81 79 78 73 62 6420° 85 85 82 81 79 78 73 62 6425° 87 87 84 83 81 80 75 64 6630° 88 88 85 84 82 81 76 65 6735° 90 90 87 86 84 83 78 67 69Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 88 88 85 84 82 81 76 65 6720° 88 88 85 84 82 81 76 65 6725° 89 89 86 85 83 82 77 66 6830° 90 90 87 86 84 83 78 67 6935° 91 91 88 87 85 84 79 68 70Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 207


FANSCATALOGUEAdjustable Pitch Axial Performance Data1120 Ø 12rpsHub Ø 400Blades 4Hub Ø 400Blades 8180250160140200120100150Static Pressure (Pa)8060402000°5° 10° 15° 20°25° 30°35°0 5 10 15 20Volume (m 3 /s)Static Pressure ( Pa)1005000°5°10° 15° 20° 25° 30°35°0 5 10 15 20Volume (m 3 /s)58Impeller Power, kW4.543.532.521.510.500°5°10°15°20°25°30°35°0 5 10 15 20Impeller Power, kW765432100°5°10°15°20°25°30°35°0 5 10 15 20Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 83 92 90 89 85 80 76 69 705° 82 91 89 88 84 79 75 68 6910° 81 90 88 87 83 78 74 67 6815° 81 90 88 87 83 78 74 67 6820° 81 90 88 87 83 78 74 67 6825° 81 90 88 87 83 78 74 67 6830° 82 91 89 88 84 79 75 68 6935° 82 91 89 88 84 79 75 68 69Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 86 95 93 92 88 83 79 72 735° 85 94 92 91 87 82 78 71 7210° 84 93 91 90 86 81 77 70 7115° 84 93 91 90 86 81 77 70 7120° 84 93 91 90 86 81 77 70 7125° 84 93 91 90 86 81 77 70 7130° 85 94 92 91 87 82 78 71 7235° 85 94 92 91 87 82 78 71 72Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.208 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1120 Ø 12 rpsHub Ø 400Blades 12Hub Ø 400Blades 16300350250300200250200150150Static Pressure (Pa)1005000°5° 10° 15° 20° 25°30°35°Static Pressure (Pa)1005000° 5° 10°15° 20° 25° 30°35°0 5 10 15 20 25Volume (m 3 /s)0 5 10 15 20 25Volume (m 3 /s)910Impeller Power, kW8765432100°5°10°15°20°25°30°35°Impeller Power, kW98765432100°5°10°15°20°25°30°35°0 5 10 15 20 250 5 10 15 20 25Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 87 92 95 93 90 85 81 74 745° 86 91 94 92 89 84 80 73 7310° 85 90 93 91 88 83 79 72 7215° 84 89 92 90 87 82 78 71 7120° 84 89 92 90 87 82 78 71 7125° 85 90 93 91 88 83 79 72 7230° 85 90 93 91 88 83 79 72 7235° 86 91 94 92 89 84 80 73 73Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 87 88 96 94 91 87 82 75 755° 87 88 96 94 91 87 82 75 7510° 86 87 95 93 90 86 81 74 7415° 85 86 94 92 89 85 80 73 7320° 85 86 94 92 89 85 80 73 7325° 85 86 94 92 89 85 80 73 7330° 85 86 94 92 89 85 80 73 7335° 86 87 95 93 90 86 81 74 74Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 209


FANSCATALOGUEAdjustable Pitch Axial Performance Data1250 Ø 24 rpsHub Ø 255Blades 6Hub Ø 255Blades 12900140080012007006001000500800400600Static Pressure (Pa)30020010005° 10° 15° 20° 25°30°Static Pressure (Pa)40020005° 10° 15° 20° 25° 30° 35°0 10 20 30 40 50Volume (m 3 /s)0 20 40 60Volume (m 3 /s)457040353025°30°605025°30°35°Impeller Power, kW25201510505°10°15°20°Impeller Power, kW4030201005° 10° 15°20°0 10 20 30 40 500 10 20 30 40 50 60Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 99 98 103 105 103 97 96 93 8710° 98 97 102 104 102 96 95 92 8615° 99 98 103 105 103 97 96 93 8720° 101 100 105 107 105 99 98 95 8925° 104 103 108 110 108 102 101 98 9230° 108 107 112 114 112 106 105 102 96Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 99 95 102 109 105 101 96 91 8910° 99 95 102 109 105 101 96 91 8915° 99 95 102 109 105 101 96 91 8920° 101 97 104 111 107 103 98 93 9125° 104 100 107 114 110 106 101 96 9430° 108 104 111 118 114 110 105 100 9835° 111 107 114 121 117 113 108 103 101Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.210 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1250 Ø 24 rpsHub Ø 330Blades 8Hub Ø 330Blades 1680012007001000600500800400600Static Pressure ( Pa)300200100015° 20° 25° 30° 35°Static Pressure ( Pa)400200015° 20° 25° 30° 35°0 10 20 30 40 50Volume (m 3 /s)0 20 40 60Volume (m 3 /s)6090504030°35°80706030°35°Impeller Power, kW302010015°20°25°Impeller Power, kW5040302010015°20°25°0 10 20 30 40 500 10 20 30 40 50 60Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 105 105 102 101 99 98 93 82 8420° 107 107 104 103 101 100 95 84 8625° 108 108 105 104 102 101 96 85 8730° 109 109 106 105 103 102 97 86 8835° 111 111 108 107 105 104 99 88 90Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 102 102 104 104 103 102 98 86 8820° 102 102 104 104 103 102 98 86 8825° 103 103 105 105 104 103 99 87 8930° 104 104 106 106 105 104 100 88 9035° 106 106 108 108 107 106 102 90 92Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 211


FANSCATALOGUEAdjustable Pitch Axial Performance Data1250 Ø 24 rpsHub Ø 400Blades 4Hub Ø 400Blades 880012007001000600500800400600Static Pressure (Pa)30020010000° 5° 10°15° 20° 25°Static Pressure (Pa)40020000° 5°10° 15° 20° 25°0 10 20 30 40 50Volume (m 3 /s)0 10 20 30 40 50Volume (m 3 /s)35603025°5025°Impeller Power, kW25201510500°5°10°15°20°Impeller Power, kW4030201000°5°10°15°20°0 10 20 30 40 500 10 20 30 40 50Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 111 120 118 117 113 108 104 97 985° 108 117 115 114 110 105 101 94 9510° 107 116 114 113 109 104 100 93 9415° 105 114 112 111 107 102 98 91 9220° 106 115 113 112 108 103 99 92 9325° 106 115 113 112 108 103 99 92 93Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 114 123 121 120 116 111 107 100 1015° 111 120 118 117 113 108 104 97 9810° 110 119 117 116 112 107 103 96 9715° 108 117 115 114 110 105 101 94 9520° 109 118 116 115 111 106 102 95 9625° 109 118 116 115 111 106 102 95 96Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.212 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1250 Ø 24 rpsHub Ø 400Blades 12Hub Ø 400Blades 1614001800120016001400100012008001000600800Static Pressure (Pa)40020000° 5° 10°15° 20° 25°Static Pressure (Pa)60040020000° 5° 10°15° 20° 25°0 10 20 30 40 50Volume (m 3 /s)0 10 20 30 40 50Volume (m 3 /s)7080Impeller Power, kW60504030201000°5°10°15°20°25°Impeller Power, kW7060504030201000°5°10°15°20°25°0 10 20 30 40 500 10 20 30 40 50Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 115 120 123 121 118 113 109 102 1025° 112 117 120 118 115 110 106 99 9910° 111 116 119 117 114 109 105 98 9815° 110 115 118 116 113 108 104 97 9720° 109 114 117 115 112 107 103 96 9625° 109 114 117 115 112 107 103 96 96Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 115 116 124 122 119 115 110 103 1035° 112 113 121 119 116 112 107 100 10010° 112 113 121 119 116 112 107 100 10015° 111 112 120 118 115 111 106 99 9920° 110 111 119 117 114 110 105 98 9825° 110 111 119 117 114 110 105 98 98Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 213


FANSCATALOGUEAdjustable Pitch Axial Performance Data1250 Ø 16 rpsHub Ø 255Blades 6Hub Ø 255Blades 12400600350500300250400200300Static Pressure (Pa)1501005005° 10° 15° 20° 25° 30°Static Pressure (Pa)20010005° 10° 15° 20° 25° 30° 35°0 10 20 30Volume (m 3 /s)0 10 20 30 40Volume (m 3 /s)Impeller Power, kW141210864205°10°15°20°25°30°0 5 10 15 20 25 30Impeller Power, kW201816141210864205°10°15°20°25°30°35°0 10 20 30 40Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 89 88 93 95 93 87 86 83 7710° 89 88 93 95 93 87 86 83 7715° 89 88 93 95 93 87 86 83 7720° 92 91 96 98 96 90 89 86 8025° 94 93 98 100 98 92 91 88 8230° 98 97 102 104 102 96 95 92 86Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 89 85 92 99 95 91 86 81 7910° 89 85 92 99 95 91 86 81 7915° 90 86 93 100 96 92 87 82 8020° 91 87 94 101 97 93 88 83 8125° 94 90 97 104 100 96 91 86 8430° 98 94 101 108 104 100 95 90 8835° 101 97 104 111 107 103 98 93 91Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.214 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1250 Ø 16 rpsHub Ø 330Blades 8Hub Ø 330Blades 16400500350450300400350250300200250Static Pressure ( Pa)15010050015° 20° 25°30° 35°0 5 10 15 20 25Volume (m 3 /s)Static Pressure ( Pa)20015010050015° 20° 25° 30° 35°0 10 20 30 40Volume (m 3 /s)163014121030°35°252030°35°Impeller Power, kW8642015°20°25°0 5 10 15 20 25Impeller Power, kW15105015°20°25°0 10 20 30 40Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 96 96 93 92 90 89 84 73 7520° 97 97 94 93 91 90 85 74 7625° 99 99 96 95 93 92 87 76 7830° 99 99 96 95 93 92 87 76 7835° 101 101 98 97 95 94 89 78 80Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 93 93 95 95 94 93 89 77 7920° 93 93 95 95 94 93 89 77 7925° 93 93 95 95 94 93 89 77 7930° 94 94 96 96 95 94 90 78 8035° 97 97 99 99 98 97 93 81 83Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 215


FANSCATALOGUEAdjustable Pitch Axial Performance Data1250 Ø 16 rpsHub Ø 400Blades 4Hub Ø 400Blades 8350500300450400250350200300250150200Static Pressure (Pa)1005000° 5° 10° 15° 20°25°30°35°Static Pressure (Pa)1501005000° 5°10° 15° 20° 25° 30° 35°0 10 20 30 40Volume (m 3 /s)0 10 20 30 40Volume (m 3 /s)16141230°35°252030°35°Impeller Power, kW10864200°5°10°15°20°25°Impeller Power, kW1510500°5°10°15°20°25°0 10 20 30 400 10 20 30 40Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 85 94 92 91 87 82 78 71 725° 84 93 91 90 86 81 77 70 7110° 83 92 90 89 85 80 76 69 7015° 83 92 90 89 85 80 76 69 7020° 83 92 90 89 85 80 76 69 7025° 84 93 91 90 86 81 77 70 7130° 84 93 91 90 86 81 77 70 7135° 85 94 92 91 87 82 78 71 72Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 88 97 95 94 90 85 81 74 755° 87 96 94 93 89 84 80 73 7410° 86 95 93 92 88 83 79 72 7315° 86 95 93 92 88 83 79 72 7320° 86 95 93 92 88 83 79 72 7325° 87 96 94 93 89 84 80 73 7430° 87 96 94 93 89 84 80 73 7435° 88 97 95 94 90 85 81 74 75Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.216 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1250 Ø 16 rpsHub Ø 400Blades 12Hub Ø 400Blades 16700800600700500600400500400Static Pressure (Pa)30020010000° 5° 10° 15° 20° 25° 30°35°Static Pressure (Pa)30020010000° 5° 10°15° 20° 25° 30°35°0 10 20 30 40Volume (m 3 /s)0 10 20 30 40Volume (m 3 /s)3540Impeller Power, kW3025201510500°5°10°15°20°25°30°35°Impeller Power, kW353025201510500°5°10°15°20°25°30°35°0 10 20 30 400 10 20 30 40Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 89 94 97 95 92 87 83 76 765° 88 93 96 94 91 86 82 75 7510° 87 92 95 93 90 85 81 74 7415° 87 92 95 93 90 85 81 74 7420° 87 92 95 93 90 85 81 74 7425° 87 92 95 93 90 85 81 74 7430° 88 93 96 94 91 86 82 75 7535° 88 93 96 94 91 86 82 75 75Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 90 91 99 97 94 90 85 78 785° 89 90 98 96 93 89 84 77 7710° 89 90 98 96 93 89 84 77 7715° 88 89 97 95 92 88 83 76 7620° 88 89 97 95 92 88 83 76 7625° 88 89 97 95 92 88 83 76 7630° 88 89 97 95 92 88 83 76 7635° 89 90 98 96 93 89 84 77 77Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 217


FANSCATALOGUEAdjustable Pitch Axial Performance Data1250 Ø 12 rpsHub Ø 255Blades 6Hub Ø 255Blades 12250350200300250150200100150Static Pressure (Pa)5005° 10° 15° 20° 25°30°Static Pressure (Pa)1005005° 10° 15° 20° 25° 30° 35°0 5 10 15 20 25Volume (m 3 /s)0 10 20 30Volume (m 3 /s)69530°8730°35°425°625°Impeller Power, kW32105°10°15°20°Impeller Power, kW5432105° 10° 15°20°0 5 10 15 20 250 5 10 15 20 25 30Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 82 81 86 88 86 80 79 76 7010° 82 81 86 88 86 80 79 76 7015° 82 81 86 88 86 80 79 76 7020° 85 84 89 91 89 83 82 79 7325° 87 86 91 93 91 85 84 81 7530° 91 90 95 97 95 89 88 85 79Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m5° 82 78 85 92 88 84 79 74 7210° 82 78 85 92 88 84 79 74 7215° 83 79 86 93 89 85 80 75 7320° 84 80 87 94 90 86 81 76 7425° 88 84 91 98 94 90 85 80 7830° 91 87 94 101 97 93 88 83 8135° 94 90 97 104 100 96 91 86 84Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.218 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1250 Ø 12 rpsHub Ø 330Blades 8Hub Ø 330Blades 16300300250250200200150150Static Pressure ( Pa)10050015° 20° 25° 30° 35°Static Pressure ( Pa)10050015° 20° 25° 30° 35°0 10 20 30Volume (m 3 /s)0 10 20 30Volume (m 3 /s)12121035°1035°830°830°Impeller Power, kW642015°20°25°Impeller Power, kW642015°20°25°0 5 10 15 20 25 300 5 10 15 20 25 30Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 89 89 86 85 83 82 77 66 6820° 90 90 87 86 84 83 78 67 6925° 92 92 89 88 86 85 80 69 7130° 92 92 89 88 86 85 80 69 7135° 94 94 91 90 88 87 82 71 73Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 86 86 88 88 87 86 82 70 7220° 86 86 88 88 87 86 82 70 7225° 86 86 88 88 87 86 82 70 7230° 87 87 89 89 88 87 83 71 7335° 90 90 92 92 91 90 86 74 76Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 219


FANSCATALOGUEAdjustable Pitch Axial Performance Data1250 Ø 12 rpsHub Ø 400Blades 4Hub Ø 400Blades 820030018016025014020012010015080Static Pressure (Pa)60402000° 5° 10°15° 20° 25° 30° 35°Static Pressure (Pa)1005000° 5° 10° 15° 20° 25° 30° 35°0 5 10 15 20 25Volume (m 3 /s)0 10 20 30Volume (m 3 /s)712Impeller Power, kW65432100°5°10°15°20°25°30°35°Impeller Power, kW10864200°5°10°15°20°25°30°35°0 5 10 15 20 250 5 10 15 20 25 30Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 79 88 86 85 81 76 72 65 665° 77 86 84 83 79 74 70 63 6410° 76 85 83 82 78 73 69 62 6315° 76 85 83 82 78 73 69 62 6320° 76 85 83 82 78 73 69 62 6325° 77 86 84 83 79 74 70 63 6430° 77 86 84 83 79 74 70 63 6435° 78 87 85 84 80 75 71 64 65Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 79 88 86 85 81 76 72 65 665° 77 86 84 83 79 74 70 63 6410° 76 85 83 82 78 73 69 62 6315° 76 85 83 82 78 73 69 62 6320° 76 85 83 82 78 73 69 62 6325° 77 86 84 83 79 74 70 63 6430° 77 86 84 83 79 74 70 63 6435° 78 87 85 84 80 75 71 64 65Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.220 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1250 Ø 12 rpsHub Ø 400Blades 12Hub Ø 400Blades 16350450300400350250300200250150200Static Pressure (Pa)1005000° 5° 10°15° 20° 25° 30°35°Static Pressure (Pa)1501005000° 5° 10°15° 20° 25° 30°35°0 10 20 30Volume (m 3 /s)0 10 20 30Volume (m 3 /s)14161235°1435°Impeller Power, kW10864200°5°10°15°20°25°30°Impeller Power, kW1210864200°5°10°15°20°25°30°0 5 10 15 20 25 300 5 10 15 20 25 30Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 82 91 89 88 84 79 75 68 695° 80 89 87 86 82 77 73 66 6710° 79 88 86 85 81 76 72 65 6615° 79 88 86 85 81 76 72 65 6620° 79 88 86 85 81 76 72 65 6625° 80 89 87 86 82 77 73 66 6730° 80 89 87 86 82 77 73 66 6735° 81 90 88 87 83 78 74 67 68Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 83 84 92 90 87 83 78 71 715° 82 83 91 89 86 82 77 70 7010° 82 83 91 89 86 82 77 70 7015° 81 82 90 88 85 81 76 69 6920° 81 82 90 88 85 81 76 69 6925° 81 82 90 88 85 81 76 69 6930° 81 82 90 88 85 81 76 69 6935° 82 83 91 89 86 82 77 70 70Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 221


FANSCATALOGUEAdjustable Pitch Axial Performance Data1400 Ø 24 rpsHub Ø 400Blades 4Hub Ø 400Blades 810001600900140080070012006001000500800Static Pressure (Pa)40030020010000° 5° 10°15°Static Pressure (Pa)60040020000° 5° 10°15°0 10 20 30 40 50Volume (m 3 /s)0 10 20 30 40 50Volume (m 3 /s)3560Impeller Power, kW3025201510500°5°10°15°Impeller Power, kW504030201000°5°10°15°0 10 20 30 40 500 10 20 30 40 50Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 106 115 113 112 108 103 99 92 935° 112 121 119 118 114 109 105 98 9910° 111 120 118 117 113 108 104 97 9815° 109 118 116 115 111 106 102 95 96Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 109 118 116 115 111 106 102 95 965° 115 124 122 121 117 112 108 101 10210° 114 123 121 120 116 111 107 100 10115° 112 121 119 118 114 109 105 98 99Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.222 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1400 Ø 24 rpsHub Ø 400Blades 12Hub Ø 400Blades 16180025001600140020001200100015008001000Static Pressure (Pa)60040020000° 5° 10°15°Static Pressure (Pa)50000° 5° 10°0 10 20 30 40 50Volume (m 3 /s)0 10 20 30 40Volume (m 3 /s)7070605015°605010°Impeller Power, kW4030201000°5°10°Impeller Power, kW4030201000°5°0 10 20 30 40 500 10 20 30 40Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 109 114 117 115 112 107 103 96 965° 116 121 124 122 119 114 110 103 10310° 115 120 123 121 118 113 109 102 10215° 114 119 122 120 117 112 108 101 101Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 110 111 119 117 114 110 105 98 985° 116 117 125 123 120 116 111 104 10410° 116 117 125 123 120 116 111 104 104Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 223


FANSCATALOGUEAdjustable Pitch Axial Performance Data1400 Ø 16 rpsHub Ø 400Blades 4Hub Ø 400Blades 8450700400600350300500250400200300Static Pressure (Pa)1501005000° 5° 10° 15° 20° 25° 30°35°Static Pressure (Pa)20010000° 5° 10°15° 20° 25° 30° 35°0 10 20 30 40 50Volume (m 3 /s)0 10 20 30 40 50Volume (m 3 /s)3045252030°35°40353030°35°Impeller Power, kW1510500°5°10°15°20°25°Impeller Power, kW25201510500°5°10°15°20°25°0 10 20 30 40 500 10 20 30 40 50Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 89 98 96 95 91 86 82 75 765° 88 97 95 94 90 85 81 74 7510° 87 96 94 93 89 84 80 73 7415° 87 96 94 93 89 84 80 73 7420° 87 96 94 93 89 84 80 73 7425° 88 97 95 94 90 85 81 74 7530° 88 97 95 94 90 85 81 74 7535° 89 98 96 95 91 86 82 75 76Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 92 101 99 98 94 89 85 78 795° 91 100 98 97 93 88 84 77 7810° 90 99 97 96 92 87 83 76 7715° 90 99 97 96 92 87 83 76 7720° 90 99 97 96 92 87 83 76 7725° 91 100 98 97 93 88 84 77 7830° 91 100 98 97 93 88 84 77 7835° 92 101 99 98 94 89 85 78 79Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.224 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1400 Ø 16 rpsHub Ø 400Blades 12Hub Ø 400Blades 16800900700800600700500600400500400Static Pressure (Pa)30020010000° 5° 10°15° 20° 25° 30°35°Static Pressure (Pa)30020010000° 5° 10°15° 20° 25° 30°35°0 20 40 60Volume (m 3 /s)0 20 40 60Volume (m 3 /s)6070Impeller Power, kW504030201000°5°10°15°20°25°30°35°Impeller Power, kW60504030201000°5°10°15°20°25°30°35°0 10 20 30 40 50 600 10 20 30 40 50 60Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 93 98 101 99 96 91 87 80 805° 92 97 100 98 95 90 86 79 7910° 91 96 99 97 94 89 85 78 7815° 91 96 99 97 94 89 85 78 7820° 91 96 99 97 94 89 85 78 7825° 91 96 99 97 94 89 85 78 7830° 92 97 100 98 95 90 86 79 7935° 92 97 100 98 95 90 86 79 79Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 94 95 103 101 98 94 89 82 825° 93 94 102 100 97 93 88 81 8110° 93 94 102 100 97 93 88 81 8115° 92 93 101 99 96 92 87 80 8020° 92 93 101 99 96 92 87 80 8025° 92 93 101 99 96 92 87 80 8030° 92 93 101 99 96 92 87 80 8035° 93 94 102 100 97 93 88 81 81Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 225


FANSCATALOGUEAdjustable Pitch Axial Performance Data1400 Ø 12 rpsHub Ø 400Blades 4Hub Ø 400Blades 8250400350200300150250200Static Pressure (Pa)1005000° 5° 10° 15° 20°25°30°35°Static Pressure (Pa)1501005000° 5° 10° 15° 20° 25° 30°35°0 10 20 30 40Volume (m 3 /s)0 10 20 30 40Volume (m 3 /s)Impeller Power, kW1210864200°5°10°15°20°25°30°35°Impeller Power, kW1816141210864200°5°10°15°20°25°30°35°0 10 20 30 400 10 20 30 40Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 83 92 90 89 85 80 76 69 705° 81 90 88 87 83 78 74 67 6810° 80 89 87 86 82 77 73 66 6715° 80 89 87 86 82 77 73 66 6720° 80 89 87 86 82 77 73 66 6725° 81 90 88 87 83 78 74 67 6830° 81 90 88 87 83 78 74 67 6835° 82 91 89 88 84 79 75 68 69Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 86 95 93 92 88 83 79 72 735° 84 93 91 90 86 81 77 70 7110° 83 92 90 89 85 80 76 69 7015° 83 92 90 89 85 80 76 69 7020° 83 92 90 89 85 80 76 69 7025° 84 93 91 90 86 81 77 70 7130° 84 93 91 90 86 81 77 70 7135° 85 94 92 91 87 82 78 71 72Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.226 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1400 Ø 12 rpsHub Ø 400Blades 12Hub Ø 400Blades 16450600400350500300400250200300Static Pressure (Pa)1501005000° 5° 10°15° 20° 25° 30°35°Static Pressure (Pa)20010000° 5° 10°15° 20° 25° 30°35°0 10 20 30 40Volume (m 3 /s)0 10 20 30 40Volume (m 3 /s)25302035°2535°1530°2030°Impeller Power, kW10500°5°10°15°20°25°Impeller Power, kW1510500°5°10°15°20°25°0 10 20 30 400 10 20 30 40Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 86 91 94 92 89 84 80 73 735° 85 90 93 91 88 83 79 72 7210° 84 89 92 90 87 82 78 71 7115° 84 89 92 90 87 82 78 71 7120° 84 89 92 90 87 82 78 71 7125° 84 89 92 90 87 82 78 71 7130° 85 90 93 91 88 83 79 72 7235° 85 90 93 91 88 83 79 72 72Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 87 88 96 94 91 87 82 75 755° 87 88 96 94 91 87 82 75 7510° 86 87 95 93 90 86 81 74 7415° 85 86 94 92 89 85 80 73 7320° 85 86 94 92 89 85 80 73 7325° 85 86 94 92 89 85 80 73 7330° 85 86 94 92 89 85 80 73 7335° 86 87 95 93 90 86 81 74 74Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 227


FANSCATALOGUEAdjustable Pitch Axial Performance Data1500 Ø 16 rpsHub Ø 400Blades 4Hub Ø 400Blades 8500800450700400350600300500250400200300Static Pressure, Pa15010050000° 05° 10°15° 20° 25°Static Pressure, Pa200100000° 05° 10°15° 20°22°25°0 10 20 30 40 500 20 40 60Volume m 3 /sVolume m 3 /s3040Impeller Power, kW252015105000°05°10°15°20°25°Impeller Power, kW3530252015105000°05°10°15°25°22°20°0 10 20 30 40 500 10 20 30 40 50 60Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3mPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 92 101 99 98 94 89 85 78 790° 95 104 102 101 97 92 88 81 825° 91 100 98 97 93 88 84 77 785° 94 103 101 100 96 91 87 80 8110° 89 98 96 95 91 86 82 75 7610° 92 101 99 98 94 89 85 78 7915° 90 99 97 96 92 87 83 76 7715° 92 102 100 99 95 90 86 79 8020° 90 99 97 96 92 87 83 76 7720° 93 102 100 99 95 90 86 79 8025° 90 99 97 96 92 87 83 76 7722° 93 102 100 99 95 90 86 79 8025° 93 102 100 99 95 90 86 79 80Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.228 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1500 Ø 16 rpsHub Ø 400Blades 12Hub Ø 400Blades 1690012008001000700600800500600400Static Pressure, Pa300200100000° 05° 10°15° 20° 25°Static Pressure, Pa400200000° 05° 10°15° 20° 25°0 20 40 600 20 40 60Volume m 3 /sVolume m 3 /s5060454025°5025°353020°4020°Impeller Power, kW252015105000°05°10°15°Impeller Power, kW302010000°05°10°15°0 10 20 30 40 50 600 10 20 30 40 50 60Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3mPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 96 101 104 102 99 94 90 83 830° 96 97 105 103 100 96 91 84 845° 95 100 103 101 98 93 89 82 825° 96 97 105 103 100 96 91 84 8410° 94 99 102 101 97 92 88 81 8210° 95 96 104 102 99 95 90 83 8315° 93 98 101 100 96 92 87 80 8115° 94 95 103 101 98 94 89 82 8220° 93 98 101 100 96 92 87 80 8120° 94 95 103 101 98 94 89 82 8225° 94 99 102 100 97 92 88 81 8125° 94 95 103 101 98 94 89 82 82Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 229


FANSCATALOGUEAdjustable Pitch Axial Performance Data1500 Ø 12 rpsHub Ø 400Blades 4Hub Ø 400Blades 8300450400250350200300250150200Static Pressure, Pa1005000° 5° 10°15° 20° 25°Static Pressure, Pa1501005000° 5° 10°15° 20° 25°0 10 20 30 400 10 20 30 40Volume m 3 /sVolume m 3 /s12181025°161425°Impeller Power, kW864200°5°10°15°20°Impeller Power, kW1210864200°5°10°15°20°0 10 20 30 400 10 20 30 40Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3mPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 85 94 92 91 87 82 78 71 720° 88 97 95 94 90 85 81 74 755° 84 93 91 90 86 81 77 70 715° 87 96 94 93 89 84 80 73 7410° 82 91 89 88 84 79 75 68 6910° 85 94 92 91 87 82 78 71 7215° 83 92 90 89 85 80 76 69 7015° 85 95 93 92 88 83 79 72 7320° 83 92 90 89 85 80 76 69 7020° 86 95 93 92 88 83 79 72 7325° 83 92 90 89 85 80 76 69 7025° 86 95 93 92 88 83 79 72 73Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.230 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1500 Ø 12 rpsHub Ø 400Blades 12Hub Ø 400Blades 16500600450400350300250500400300200Static Pressure, Pa1501005000° 5° 10°15° 20° 25°Static Pressure, Pa20010000° 5° 10°15° 20° 25°0 10 20 30 40 500 10 20 30 40Volume m 3 /sVolume m 3 /s25252025°2025°Impeller Power, kW1510500°5°10°15°20°Impeller Power, kW1510500°5°10°15°20°0 10 20 30 40 500 10 20 30 40Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3mPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 89 94 97 95 92 87 83 76 760° 89 90 98 96 93 89 84 77 785° 88 93 96 94 91 86 82 75 755° 89 90 98 96 93 89 84 77 7810° 87 92 95 94 90 85 81 74 7510° 88 89 97 95 92 88 83 76 7715° 86 91 94 93 89 85 80 73 7415° 87 88 96 94 91 87 82 75 7620° 86 91 94 93 89 85 80 73 7420° 87 88 96 94 91 87 82 75 7625° 87 92 95 93 90 85 81 74 7425° 87 88 96 94 91 87 82 75 76Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 231


FANSCATALOGUEAdjustable Pitch Axial Performance Data1600 Ø 16 rpsHub Ø 400Blades 4Hub Ø 400Blades 8600900500800700400600300500400Static Pressure (Pa)20010000° 5° 10°15° 20° 25°Static Pressure (Pa)30020010000° 5° 10° 15° 20° 25°0 20 40 60Volume (m 3 /s)0 20 40 60 80Volume (m 3 /s)4060Impeller Power, kW353025201510500°5°10°15°20°25°Impeller Power, kW504030201000°5°10°15°20°25°0 10 20 30 40 50 600 20 40 60 80Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 94 103 101 100 96 91 87 80 815° 93 102 100 99 95 90 86 79 8010° 91 100 98 97 93 88 84 77 7815° 91 100 98 97 93 88 84 77 7820° 92 101 99 98 94 89 85 78 7925° 92 101 99 98 94 89 85 78 79Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 97 106 104 103 99 94 90 83 845° 96 105 103 102 98 93 89 82 8310° 94 103 101 100 96 91 87 80 8115° 94 103 101 100 96 91 87 80 8120° 95 104 102 101 97 92 88 81 8225° 95 104 102 101 97 92 88 81 82Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.232 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1600 Ø 16 rpsHub Ø 400Blades 12Hub Ø 400Blades 161200120010001000800800600600Static Pressure (Pa)40020000° 5° 10°15° 20° 25°Static Pressure (Pa)40020000° 5° 10°15° 20° 25°0 20 40 60 80Volume (m 3 /s)0 20 40 60 80Volume (m 3 /s)7090Impeller Power, kW60504030201000°5°10°15°20°25°Impeller Power, kW807060504030201000°5°10°15°20°25°0 20 40 60 800 20 40 60 80Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 98 103 106 104 101 96 92 85 855° 97 102 105 103 100 95 91 84 8410° 96 101 104 102 99 94 90 83 8315° 95 100 103 101 98 93 89 82 8220° 95 100 103 101 98 93 89 82 8225° 96 101 104 102 99 94 90 83 83Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 98 99 107 105 102 98 93 86 865° 98 99 107 105 102 98 93 86 8610° 97 98 106 104 101 97 92 85 8515° 96 97 105 103 100 96 91 84 8420° 96 97 105 103 100 96 91 84 8425° 96 97 105 103 100 96 91 84 84Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 233


FANSCATALOGUEAdjustable Pitch Axial Performance Data1600 Ø 12 rpsHub Ø 400Blades 4Hub Ø 400Blades 8350500300450400250350200300250150200Static Pressure (Pa)1005000° 5° 10°15° 20° 25° 30° 35°Static Pressure (Pa)1501005000° 5° 10° 15° 20° 25° 30°35°0 10 20 30 40 50Volume (m 3 /s)0 20 40 60Volume (m 3 /s)2540Impeller Power, kW201510500°5°10°15°20°25°30°35°Impeller Power, kW353025201510500°5°10°15°20°25°30°35°0 10 20 30 40 500 10 20 30 40 50 60Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 87 96 94 93 89 84 80 73 745° 86 95 93 92 88 83 79 72 7310° 84 93 91 90 86 81 77 70 7115° 84 93 91 90 86 81 77 70 7120° 85 94 92 91 87 82 78 71 7225° 85 94 92 91 87 82 78 71 7230° 85 94 92 91 87 82 78 71 7235° 86 95 93 92 88 83 79 72 73Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 90 99 97 96 92 87 83 76 775° 89 98 96 95 91 86 82 75 7610° 87 96 94 93 89 84 80 73 7415° 87 96 94 93 89 84 80 73 7420° 88 97 95 94 90 85 81 74 7525° 88 97 95 94 90 85 81 74 7530° 88 97 95 94 90 85 81 74 7535° 89 98 96 95 91 86 82 75 76Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.234 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1600 Ø 12 rpsHub Ø 400Blades 12Hub Ø 400Blades 16600700500600400500400300300Static Pressure (Pa)20010000° 5° 10°15° 20° 25° 30° 35°Static Pressure (Pa)20010000° 5° 10°15° 20° 25° 30°35°0 20 40 60Volume (m 3 /s)0 20 40 60Volume (m 3 /s)Impeller Power, kW4540353025201510500°5°10°15°20°25°30°35°0 10 20 30 40 50 60Impeller Power, kW60504030201000°5°10°15°20°25°30°35°0 10 20 30 40 50 60Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 91 96 99 97 94 89 85 78 785° 90 95 98 96 93 88 84 77 7710° 89 94 97 95 92 87 83 76 7615° 88 93 96 94 91 86 82 75 7520° 88 93 96 94 91 86 82 75 7525° 89 94 97 95 92 87 83 76 7630° 89 94 97 95 92 87 83 76 7635° 90 95 98 96 91 88 84 77 77Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 91 92 100 98 95 91 86 79 795° 91 92 100 98 95 91 86 79 7910° 90 91 99 97 94 90 85 78 7815° 89 90 98 96 93 89 84 77 7720° 89 90 98 96 93 89 84 77 7725° 89 90 98 96 93 89 84 77 7730° 89 90 98 96 93 89 84 77 7735° 90 91 99 97 94 90 85 78 78Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 235


FANSCATALOGUEAdjustable Pitch Axial Performance Data1600 Ø 9.5 rpsHub Ø 400Blades 4Hub Ø 400Blades 8250350200300250150200100150Static Pressure (Pa)5000° 5° 10° 15° 20°25° 30° 35°Static Pressure (Pa)1005000° 5° 10° 15° 20° 25° 30°35°0 10 20 30 40 50Volume (m 3 /s)0 10 20 30 40 50Volume (m 3 /s)1425121030°35°2035°Impeller Power, kW864200°5°10°15°20°25°0 10 20 30 40 50Impeller Power, kW1510500°5°10°15°20°25°30°0 10 20 30 40 50Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 83 92 90 89 85 80 76 69 705° 82 91 89 88 84 79 75 68 6910° 80 89 87 86 82 77 73 66 6715° 80 89 87 86 82 77 73 66 6720° 81 90 88 87 83 78 74 67 6825° 81 90 88 87 83 78 74 67 6830° 81 90 88 87 83 78 74 67 6835° 82 91 89 88 84 79 75 68 69Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 86 95 93 92 88 83 79 72 735° 85 94 92 91 87 82 78 71 7210° 83 92 90 89 85 80 76 69 7015° 83 92 90 89 85 80 76 69 7020° 84 93 91 90 86 81 77 70 7125° 84 93 91 90 86 81 77 70 7130° 84 93 91 90 86 81 77 70 7135° 85 94 92 91 87 82 78 71 72Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.236 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1600 Ø 9.5 rpsHub Ø 400Blades 12Hub Ø 400Blades 16400500350450300400350250300200250Static Pressure (Pa)1501005000° 5° 10°15° 20° 25° 30° 35°Static Pressure (Pa)2001501005000° 5° 10°15° 20° 25° 30°35°0 10 20 30 40 50Volume (m 3 /s)0 10 20 30 40 50Volume (m 3 /s)3035Impeller Power, kW25201510500°5°10°15°20°25°30°35°Impeller Power, kW3025201510500°5°10°15°20°25°30°35°0 10 20 30 40 500 10 20 30 40 50Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 87 92 95 93 90 85 81 74 745° 86 91 94 92 89 84 80 73 7310° 85 90 93 91 88 83 79 72 7215° 84 89 92 90 87 82 78 71 7120° 84 89 92 90 87 82 78 71 7125° 85 90 93 91 88 83 79 72 7230° 85 90 93 91 88 83 79 72 7235° 86 91 94 92 87 84 80 73 73Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m0° 87 88 96 94 91 87 82 75 755° 87 88 96 94 91 87 82 75 7510° 86 87 95 93 90 86 81 74 7415° 85 86 94 92 89 85 80 73 7320° 85 86 94 92 89 85 80 73 7325° 85 86 94 92 89 85 80 73 7330° 85 86 94 92 89 85 80 73 7335° 86 87 95 93 90 86 81 74 74Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 237


FANSCATALOGUEAdjustable Pitch Axial Performance Data1800 Ø 16 rpsHub Ø 385Blades 4Hub Ø 385Blades 8700800600700500600400500400Static Pressure (Pa)300200100012°15°18°21° 24° 27° 30°Static Pressure (Pa)300200100015° 18°21°24° 27° 30° 33°0 20 40 60 80 100Volume m 3 /s0 20 40 60 80 100Volume m 3 /s7080Impeller Power, kW605040302010021°18°15°12°24°27°30°Impeller Power, kW70605040302010018°15°21°24°27°30°33°0 20 40 60 80 1000 20 40 60 80 100Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m12° 100 102 102 101 96 90 84 78 8115° 101 103 103 102 97 91 85 79 8218° 102 104 104 103 98 92 86 80 8321° 103 105 105 104 99 93 87 81 8424° 104 106 106 105 100 94 88 82 8527° 105 107 107 106 101 95 89 83 8630° 106 108 108 107 102 96 90 84 87Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 101 104 105 103 98 95 88 81 8418° 102 105 106 104 99 96 89 82 8521° 103 106 107 105 100 97 90 83 8624° 104 107 108 106 101 98 91 84 8727° 105 108 109 107 102 99 92 85 8830° 106 109 110 108 103 100 93 86 8933° 107 110 111 109 104 101 94 87 90Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.238 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1800 Ø 16 rpsHub Ø 385Blades 1212001000800600Static Pressure (Pa)Impeller Power, kW400200080706050403020100Sound Data12° 15° 18° 21°24°0 20 40 60 80Volume m 3 /s12°15°18°21°24°0 20 40 60 80Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m12° 101 103 103 102 98 93 87 79 8315° 102 104 104 103 99 94 88 80 8418° 103 105 105 104 100 95 89 81 8521° 104 106 106 105 101 96 90 82 8624° 105 107 107 106 102 97 91 83 87Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 239


FANSCATALOGUEAdjustable Pitch Axial Performance Data1800 Ø 12 rpsHub Ø 385Blades 4Hub Ø 385Blades 8350450300400350250300200250150200Static Pressure (Pa)10050012°15°18°21° 24° 27°30° 33°Static Pressure (Pa)15010050015° 18°21°24° 27° 30° 33°0 20 40 60 80Volume m 3 /s0 20 40 60 80Volume m 3 /s3535303033°Impeller Power, kW252015105024°21°18°12° 15°27°33°30°Impeller Power, kW252015105018°15°21°24°27°30°0 20 40 60 800 20 40 60 80Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m12° 93 95 95 94 89 83 78 72 7415° 94 96 96 95 90 84 79 73 7518° 95 97 97 96 91 85 80 74 7621° 96 98 98 97 92 86 81 75 7724° 97 99 99 98 93 87 82 76 7827° 98 100 100 99 94 88 83 77 7930° 99 101 101 100 95 89 84 78 8033° 100 102 102 101 96 90 85 79 81Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 94 97 98 96 91 88 83 77 7718° 95 98 99 97 92 89 84 78 7821° 96 99 100 98 93 90 85 79 7924° 97 100 101 99 94 91 86 80 8027° 98 101 102 100 95 92 87 81 8130° 99 102 103 101 96 93 88 82 8233° 100 103 104 102 97 94 89 83 83Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.240 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data1800 Ø 12 rpsHub Ø 385Blades 12700600500400300Static Pressure (Pa)Impeller Power, kW200100050454035302520151050Sound Data12°15° 18°21°24° 27° 30°33°0 20 40 60 80Volume m 3 /s21°15° 18°12°24°30°27°33°0 20 40 60 80Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m12° 94 96 97 96 93 88 82 73 7715° 95 97 98 97 94 89 83 74 7818° 96 98 99 98 95 90 84 75 7921° 97 99 100 99 96 91 85 76 8024° 98 100 101 100 97 92 86 77 8127° 99 101 102 101 98 93 87 78 8230° 100 102 103 102 99 94 88 79 8333° 101 103 104 103 100 95 89 80 84Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 241


FANSCATALOGUEAdjustable Pitch Axial Performance Data2000 Ø 16 rpsHub Ø 385Blades 4Hub Ø 385Blades 88001000700900600800700500600400500Static Pressure (Pa)300200100015° 24° 27°Static Pressure (Pa)400300200100015° 18°0 20 40 60 80 100Volume m 3 /s0 20 40 60 80Volume m 3 /s6050504024°27°4540353015°18°Impeller Power, kW302010015°Impeller Power, kW25201510500 20 40 60 80 1000 20 40 60 80Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 106 107 108 107 103 97 91 85 8724° 109 110 111 110 106 100 94 88 9027° 110 111 112 111 107 101 95 89 91Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 106 108 109 108 104 99 93 87 8918° 107 109 110 109 105 100 94 88 90Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.242 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data2000 Ø 16 rpsHub Ø 385Blades 12140012001000800600Static Pressure (Pa)4002000605012°0 20 40 60 80Volume m 3 /s12°40Impeller Power, kW30201000 20 40 60 80Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m12° 110 112 111 111 107 100 94 89 91Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 243


FANSCATALOGUEAdjustable Pitch Axial Performance Data2000 Ø 12 rpsHub Ø 385Blades 4Hub Ø 385Blades 8450600400350500300400250200300Static Pressure (Pa)15010050012° 15°18°21°24° 27° 30°33°Static Pressure (Pa)200100015° 18° 21° 24°27°30°0 20 40 60 80Volume m 3 /s0 20 40 60 80Volume m 3 /s3540Impeller Power, kW30252015105012°21°18°15°24°27°30°33°Impeller Power, kW3530252015105015°18°21°24°30°27°0 20 40 60 800 20 40 60 80Sound DataPitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m12° 98 99 100 99 95 89 83 77 7915° 99 100 101 100 96 90 84 78 8018° 100 101 102 101 97 91 85 79 8121° 101 102 103 102 98 92 86 80 8224° 102 103 104 103 99 93 87 81 8327° 103 104 105 104 100 94 88 82 8430° 104 105 106 105 101 95 89 83 8533° 105 106 107 106 102 96 90 84 86Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m15° 99 101 102 101 97 92 86 80 8218° 100 102 103 102 98 93 87 81 8321° 101 103 104 103 99 94 88 82 8424° 102 104 105 104 100 95 89 83 8527° 103 105 106 105 101 96 90 84 8630° 104 106 107 106 102 97 91 85 87Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.244 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Adjustable Pitch Axial Performance Data2000 Ø 12 rpsHub Ø 385Blades 12800700600500400Static Pressure (Pa)Impeller Power, kW30020010004035302520151050Sound Data12° 15° 18°0 20 40 60 80Volume m 3 /s12°15°18°0 20 40 60 80Pitch 63 125 250 500 1k 2k 4k 8kAve. dBA@ 3m12° 103 105 104 104 100 93 87 82 8415° 104 106 105 105 101 94 88 83 8518° 105 107 106 106 102 95 89 84 86Rated fan performance has been determined by testing to BS848 Pt1 (1998). Fan sound datahas been determined by testing to AMCA 300. Type D installation.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 245


FANSCATALOGUEFEF Short Cased Inline AxialproductFEF Short Cased Inline Axialdimensions mm200 to 630poles & duty2 - 6 / up to 5,500 L/sapplicationLow noise, short cased axial fans with sickle blade impellers for medium tolow flow and pressure ducted systems.FEFThe FEF series is a range medium performance fans featuring external rotormotors and sickle blade impellers for very quiet operation. Compact casedesign allows installation in tight spaces. Ideal for medium to low flow andpressure ducted systems. <strong>Fans</strong> can be mounted at any angle.ConstructionCases are of galvanised or powder coated sheet steel with roll formedflanges. Motor supports are of corrosion protected steel.MotorsMotor windings incorporate class ‘B’ or ‘F’ insulation as standard. Motorbearings are sealed for life and maintenance free. Auto-reset thermalcontacts are generally provided, either integrally wired or terminated atwiring connection bar.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN 45635Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@3mWeightkgSPL dB referred to 10 -12 W Type D: ducted inlet/outlet (LW)63 125 250 500 1K 2K 4K 8KFEF200-2E 0.3 0.06 43 48 5 0 55 62 68 64 62 57 50FEF200-4E 0.3 0.04 23 32 5 0 52 49 52 49 42 35 34FEF250-2E 0.51 0.12 42 55 6 0 61 71 75 72 66 61 54FEF250-4E 0.53 0.07 23 40 6 0 58 58 60 57 51 42 34FEF300-2E 0.62 0.14 44 59 7 0 63 72 76 76 73 68 62FEF300-4E 0.32 0.07 23 43 7 0 62 62 61 60 55 45 37FEF350-4D 0.35 0.18 23 50 9 74 78 69 65 65 65 61 54FEF350-4E 0.9 0.2 23 50 9 74 78 69 65 65 65 61 54FEF400-4D 0.48 0.27 22 51 10 86 79 68 65 65 64 63 55FEF400-4E 1.35 0.31 22 51 10 86 79 68 65 65 64 63 55FEF400-6D 0.29 0.18 16 46 10 77 73 62 65 60 59 55 47FEF450-4D 1.15 0.61 22 55 12 83 83 72 70 71 69 66 59FEF450-4E 2.8 0.61 22 55 12 83 83 72 70 71 69 66 59FEF450-6D 0.72 0.41 17 51 12 81 77 75 66 65 63 59 51FEF450-6E 0.91 0.21 15 48 12 79 75 67 64 64 61 55 46FEF500-4D 1.35 0.78 22 56 17 76 88 74 70 70 68 63 55FEF500-4E 3.4 0.77 20 56 17 76 88 74 70 70 68 63 55FEF500-6D 0.94 0.55 17 49 17 73 78 68 65 65 62 56 48FEF500-6E 1.25 0.29 15 47 17 74 73 69 63 63 61 56 48FEF560-4D 2.6 1.25 22 62 25 83 83 77 76 78 77 72 63FEF560-6D 1.45 0.8 17 56 25 66 74 72 72 74 70 64 57FEF560-6E 2.3 0.5 15 55 25 68 76 75 70 72 69 63 56FEF630-4D 4.8 2.6 22 67 45 76 88 80 82 83 83 78 70FEF630-6E 3.5 0.78 15 52 45 62 76 70 67 70 67 58 51FEF630-6D 2.7 1.6 15 56 45 65 79 73 70 73 70 61 542E=2pole, 1phase. 2D=2 pole, 3phase, 4E=4 pole, 1Phase. 4D=4pole, 3phase. 6E=6pole, 1phase. 6D=6 pole, 3phase. 8D=8pole, 3phase.246 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Suggested SpecificationFixed pitch Axial Flow duct mounttype fans shall be of the FEF Seriesmanufactured by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.160140120FEF200Sickle bladed axial impellers shall bedriven by external rotor motors withsealed for life bearings. Cases to be ofcorrosion protected sheet steel withroll formed flanges.Pressure (Pa)100806040204E-C2E-CAll fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.01601401200 50 100 150 200 250 300Air Flow (L/s)FEF250AncillariesPressure (Pa)1008060404E-C2E-C2000 100 200 300 400 500Air Flow (L/s)Pressure (Pa)180160140120100806040200FEF300300-4E-C300-2E-C0 200 400 600 800Air Flow (L/s)FEF350Pressure (Pa)18016014012010080350-4D/E-C6040200400 500 600 700 800 900 1000Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 247


FEF Short Cased Inline AxialFANSCATALOGUE140120FEF400100Pressure (Pa)806040400-6E-C400-4D/E-C200400 600 800 1000 1200 1400Air Flow (L/s)160140120FEF450Pressure (Pa)1008060450-4D/E-C40450-6D-C20450-6E-C0450 700 950 1200 1450 1700 1950 2200Air Flow (L/s)FEF500Pressure (Pa)200180160140120500-4D-C100500-4E-C80500-6E-C60500-6D-C40200750 1000 1250 1500 1750 2000 2250 2500 2750Air Flow (L/s)FEF560250200Pressure (Pa)150100560-6D-C560-6E-C560-4D-C5001000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500Air Flow (L/s)248 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


FEF630300250Pressure (Pa)200150100630-6D-C630-4D-C50630-6E-C02000 2500 3000 3500 4000 4500 5000 5500 6000Air Flow (L/s)FEFSize A B C D E F G kg200 255 202 231 175 162 7 4 5250 306 256 282 175 188 7 4 6300 360 310 336 200 215 7 4 7350 420 356 395 150 245 9.5 8 9400 465 400 438 200 270 9.5 12 10450 515 451 488 250 300 9.5 12 12500 565 503 541 250 340 9.5 12 17560 630 560 605 250 370 11.5 16 25630 710 634 674 250 430 11.5 16 45© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 249


FANSCATALOGUEDuct MountedCentrifugal & Mixed Flow250 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


ICQ - Square Centrifugal (TEFC Motor) 252SCDQ - Square Centrifugal (External RotorMotor)256SCD/TCD Rectangular Centrifugal 260IMQ - Square Mixed Flow (TEFC) 264© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 251


ICQ - Square Centrifugal (TEFC)FANSCATALOGUEproductICQ Square Centrifugal (TEFC)dimensions mm280 - 710poles & duty4 - 8 / up to 4,500 L/sapplicationHigh performance centrifugal fans for medium to high pressure ductedsystems.ICQ SeriesThe ICQ series is a range of inline duct mounted fans for use in generalventilation systems. All models are built around high performance centrifugalimpellers driven by totally enclosed fan cooled (TEFC) motors.ConstructionCases are fabricated from galvanised sheet steel with standard duct flangesfor easy installation. Impellers are high efficiency backward curve centrifugaltype. The impeller and motor assembly is supported by a robust galvanisedsteel frame for long, trouble free service.MotorsMotors are TEFC designs incorporating sealed for life bearings. Motorenclosures feature IP54 protection in all models. Windings incorporate class‘B’ or class ‘F’ insulation as standard although class ‘H’ is readily available.EXE and EXD models are also available. Auto reset thermal contacts areprovided, either integrally wired or terminated at wiring connection bar.FeaturesHigh reliability TEFC motors with sealed for life bearings.Class ‘H’ available across all sizes.EXE, EXD, motors available across the range.High performance backward curve centrifugal impellers.Perfectly suited to medium/high volume and pressure applications.Fully speed controllable.<strong>Fans</strong> can be mounted at any angle.TestingRated fan performance has been determined by testing to BS848 Pt 1 (1998)and DIN24163 1998. Fan sound data has been determined by testing to DIN45635 and/or AMCA300Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.252 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


ICQ - Square Centrifugal (TEFC)Suggested SpecificationCentrifugal Flow duct mounted typefans shall be of the ICQ Seriesmanufactured by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.600500ICQ - 4 Pole (TEFC)Backward Curved Centrifugalimpellers shall be driven by TEFCmotors with sealed for life bearings.Cases incorporating standardisedflanges to be of galvanised sheet steelwith cross breaks in larger sizes foradded strength and noiseminimisation.Pressure (Pa)400300200450400100355280 (erm)31500 500 1000 1500 2000Air Flow (L/s)All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.12001000ICQ - 4 Pole (TEFC)AncillariesPressure (Pa)80060040020050056063000 1000 2000 3000 4000 5000Air Flow (L/s)700ICQ - 6 Pole (TEFC)600Pressure (Pa)50040030071020063010056045050035540031500 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Air Flow (L/s)350ICQ - 8 Pole (TEFC)300Pressure (Pa)25020015010071063056050400450 50000 500 1000 1500 2000 2500 3000 3500 4000Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 253


FANSCATALOGUEICQ - Square Centrifugal (TEFC)Fan ModelFull LoadCurrentMotor kW Shaft Revs /secdB(A)@ 3mSPL dB referred to 10 -12 W Type D: ducted inlet/outlet (LW)63 125 250 500 1K 2K 4K 8KICQ280-4EE 0.35 0.08 23 44 57 61 66 63 59 58 51 45ICQ280-6EE 0.35 0.08 17 37 50 54 60 56 51 50 46 40ICQ315-4DD 0.9 0.37 24 47 77 75 69 66 59 55 55 51ICQ315-4ED 1.8 0.37 24 47 77 75 69 66 59 55 55 51ICQ315-6DD 1 0.37 16 41 67 69 60 60 54 51 46 42ICQ355-4DD 0.9 0.37 24 51 75 78 72 71 61 63 59 52ICQ355-4ED 1.8 0.37 24 51 79 78 72 71 61 63 59 52ICQ355-6DD 1 0.37 16 43 65 69 64 63 58 51 46 44ICQ400-4DD 0.9 0.37 24 54 79 81 75 73 66 66 65 58ICQ400-4ED 1.8 0.37 24 54 79 81 75 73 66 66 65 58ICQ400-6DD 1 0.37 16 45 70 72 67 63 58 55 52 47ICQ400-8DD 1.1 0.37 12 38 63 65 60 56 51 48 45 40ICQ450-4DD 1.7 0.75 24 57 78 81 77 75 69 69 67 63ICQ450-4ED 3.4 0.75 24 57 78 81 77 75 69 69 67 63ICQ450-6DD 1.1 0.37 16 47 74 75 68 65 59 58 55 50ICQ450-8DD 1.2 0.37 12 40 67 68 61 58 52 51 48 43ICQ500-4DD 2.4 1.1 24 60 81 85 81 76 74 74 69 71ICQ500-4ED 4.8 1.1 24 60 81 85 81 76 74 74 69 71ICQ500-6DD 1 0.37 16 50 74 80 72 66 63 61 58 55ICQ500-8DD 1.1 0.37 12 43 67 73 65 59 56 54 51 48ICQ560-4DD 4.4 2.2 24 65 86 93 88 80 78 78 73 72ICQ560-6DD 1.7 0.55 16 54 78 82 75 70 66 66 62 61ICQ560-8DD 1.1 0.37 12 44 70 72 66 60 58 56 55 50ICQ630-4DD 7.7 4 24 69 90 97 90 83 83 81 80 75ICQ630-6DD 2.6 1.1 16 57 81 85 78 72 71 68 66 65ICQ630-8DD 1.7 0.55 12 49 70 75 70 65 64 60 60 56ICQ710-6DD 4.8 2.2 16 61 85 90 86 75 73 71 70 68ICQ710-8DD 2.1 0.75 12 47 72 75 72 61 61 57 56 534ED=4 pole, 1Phase. 4DD=4pole, 3phase. 6ED=6pole, 1phase. 6DD=6 pole, 3phase. 8DD=8pole, 3phase.ICQSize A B C kg280 350 410 445 22315 500 410 445 28.8355 550 450 485 34.1400 550 500 535 38.8450 600 550 585 45.9500 650 650 685 57.7560 750 700 735 71.7630 800 800 835 95.7710 850 900 935 112.4254 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 255


SCDQ - Square Centrifugal (ERM)FANSCATALOGUEproductSCDQ Square Centrifugal (ERM)dimensions mm315 - 630poles & duty4 - 6 / up to 3,500 L/sapplicationHigh performance centrifugal fans for medium to high pressure ductedsystems. For 8 pole and EXE motors refer to the ICQ range.SCDQ SeriesThe SCDQ series is a range of inline duct mounted fans for use in generalventilation systems. All models are built around high performance centrifugalimpellers driven by external rotor motors (ERM’s).ConstructionCases are fabricated from galvanised sheet steel with standard duct flangesfor easy installation. Impellers are high efficiency backward curve centrifugaltype. The impeller and motor assembly is supported by a robust galvanisedsteel frame for long, trouble free service.MotorsMotors are external rotor designs incorporating sealed for life bearings. Motorenclosures feature IP54 protection in all models. Windings incorporate class‘B’ or class ‘F’. Auto reset thermal contacts are provided, either integrallywired or terminated at wiring connection bar.FeaturesHigh reliability external rotor motors with sealed for life bearings.High performance backward curve centrifugal impellers.Perfectly suited to medium/high volume and pressure applications.Fully speed controllable.<strong>Fans</strong> can be mounted at any angle.TestingRated fan performance has been determined by testing to BS848 Pt 1 (1998)and DIN24163 1998. Fan sound data has been determined by testing to DIN45635 and/or AMCA300Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.256 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


SCDQ - Square Centrifugal (ERM)Suggested SpecificationCentrifugal Flow duct mounted typefans shall be of the SCDQ Seriesmanufactured by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Backward Curved Centrifugalimpellers shall be driven by externalrotor motors with sealed for lifebearings. Cases incorporatingstandardised flanges to be ofgalvanised sheet steel with crossbreaks in larger sizes for addedstrength and noise minimisation.Pressure (Pa)SCDQ - 4 Pole (ERM)4504003503002502004001503551003155000 200 400 600 800 1000 1200Air Flow (L/s)All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.12001000SCDQ - 4 Pole (ERM)Pressure (Pa)80060040020045050056063000 500 1000 1500 2000 2500 3000 3500 4000Air Flow (L/s)Ancillaries160140SCDQ - 6 Pole (ERM)Pressure (Pa)1201008060403153552000 50 100 150 200 250 300 350 400Air Flow (L/s)SCDQ - 6 Pole (ERM)600500Pressure (Pa)40030020010006305005604500 500 1000 1500 2000 2500 3000 3500Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 257


FANSCATALOGUESCDQ - Square Centrifugal (ERM)Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@3mWeightkgSPL dB referred to 10 -12 W Type D: ducted inlet/outlet (LW)63 125 250 500 1K 2K 4K 8KSCDQ315-4D 0.27 0.15 23 44 35 68 69 67 63 57 54 58 45SCDQ315-4DL 0.15 0.09 20 40 35 64 65 63 59 53 50 54 41SCDQ315-4E 0.9 0.17 22 46 35 68 73 67 65 59 55 59 47SCDQ315-6E 0.5 0.33 17 38 35 60 65 59 57 51 47 51 39SCDQ355-4D 0.49 0.3 22 48 40 68 73 71 68 61 58 55 49SCDQ355-4E 1.12 0.3 24 48 40 68 73 71 68 61 58 55 49SCDQ355-6D 0.25 0.1 18 39 40 59 64 62 59 52 49 46 40SCDQ355-6E 0.31 0.08 14 39 40 59 64 62 59 52 49 46 40SCDQ400-4D 1.41 0.44 24 52 45 69 78 75 72 64 61 60 58SCDQ400-4E 2.2 0.49 22 53 45 70 79 76 73 65 62 61 59SCDQ400-6D 0.7 0.29 21 42 45 69 69 66 61 57 49 48 36SCDQ400-6E 0.68 0.15 15 45 45 62 71 68 65 57 54 53 51SCDQ450-4D 1.3 0.51 21 54 48 69 78 78 74 67 64 65 55SCDQ450-4DL 0.66 0.36 17 45 48 60 69 69 65 58 55 56 46SCDQ450-4E 3 0.69 21 54 48 69 78 78 74 67 64 65 55SCDQ450-6D 0.75 0.29 16 47 48 62 71 71 67 60 57 58 48SCDQ450-6E 1.42 0.29 16 46 48 61 70 70 66 59 56 57 47SCDQ500-4D 3 4 23 58 50 71 81 82 77 72 68 64 63SCDQ500-4DL 1.35 0.78 19 52 50 65 75 76 71 66 62 58 57SCDQ500-4E 5.7 1.43 23 58 50 71 82 82 77 73 69 67 63SCDQ500-6D 1.1 0.5 15 47 50 71 71 72 64 62 55 52 45SCDQ500-6E 2.34 0.5 15 47 50 57 68 68 63 59 55 53 49SCDQ560-6E 3.5 0.79 16 46 55 74 74 71 62 61 56 53 49SCDQ630-4D 6.8 3.21 23 60 66 82 94 92 82 79 75 71 70SCDQ630-6D 2.8 1.31 15 60 56 72 84 82 72 69 65 61 602E=2pole, 1phase. 2D=2 pole, 3phase, 4E=4 pole, 1Phase. 4D=4pole, 3phase. 6E=6pole, 1phase. 6D=6 pole, 3phase. 8D=8pole, 3phase.Note: Sound ratings include the effect of duct end correctionSCDQSize A B C D kg315 480 410 445 350 35355 520 450 485 410 40400 570 500 535 460 45450 620 550 585 495 48500 720 650 685 525 50560 770 700 735 550 55630 870 800 835 545 60258 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 259


SCD/TCD Rectangular Centrifugal (ERM)FANSCATALOGUEproductSCD/TCD Duct Mount Centrifugal (ERM)dimensions mm280 - 710poles & duty4 - 6 / up to 4,000 L/sSCDTCDapplicationSingle and twin motor fans for medium to high pressure ducted systems. For8 pole and EXE motors refer to the ICQ range.SCD SeriesThe SCD series is a range of single motor/impeller inline duct mounted fans foruse in general ventilation systems. The SCD offers the lowest possible profileand is ideal in situations where space is limited. All models are built aroundhigh performance centrifugal impellers driven by external rotor motors.TCD SeriesThe TCD series is a range of twin motor/impeller inline duct mount fans for usein general ventilation systems. The twin motor/impeller configuration with builtin back draft dampers allows for 100% standby.ConstructionCases are fabricated from galvanised sheet steel with standard duct flangesfor easy installation. Impellers are high efficiency backward curve centrifugaltype. The impeller and motor assembly is supported by a robust galvanisedsteel frame for long, trouble free service.MotorsMotors are external rotor designs incorporating sealed for life bearings. Motorenclosures feature IP54 protection in all models. Windings incorporate class‘B’ or class ‘F’ insulation as standard. Auto reset thermal contacts areprovided, either integrally wired or terminated at wiring connection bar.FeaturesHighly reliable external rotor motors with sealed for life bearings.High performance backward curve centrifugal impellers.Perfectly suited to medium/high volume and pressure applications.Fully speed controllable.<strong>Fans</strong> can be mounted at any angle.TestingRated fan performance has been determined by testing to BS848 Pt 1 (1998)and DIN24163 1998. Fan sound data has been determined by testing to DIN45635 and/or AMCA300Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.260 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Suggested SpecificationCentrifugal Flow duct mounted typefans shall be of the SCD/TCD Seriesmanufactured by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Backward Curved Centrifugalimpellers shall be driven by externalrotor motors with sealed for lifebearings. Cases incorporatingstandardised flanges to be ofgalvanised sheet steel. TCD modelsinclude a second motor / impeller for100% standby.Pressure (Pa)SCD/TCD - 4 Pole45040035030025040020015035510031550280 (SCD only)00 200 400 600 800 1000 1200Air Flow (L/s)All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.12001000SCD/TCD - 4 PolePressure (Pa)800600400Ancillaries200450500560630 (SCD only)00 1000 2000 3000 4000 5000Air Flow (L/s)SCD/TCD - 6 Pole160140Pressure (Pa)12010080604020280 (SCD only) 28031535500 100 200 300 400 500 600Air Flow (L/s)SCD/TCD - 6 Pole600500Pressure (Pa)4003002001000710 (SCD only)630 (SCD only)450 500 5600 1000 2000 3000 4000 5000Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 261


FANSCATALOGUESCD/TCD Rectangular Centrifugal (ERM)SCDTCDSCDSize A B C D E F G H kg280/315 570 500 535 500 370 300 335 200 22355 670 600 635 700 470 400 435 280 35400 720 650 685 750 520 450 485 300 45450 770 700 735 800 570 500 535 330 57500 870 800 835 900 620 550 585 350 65560 970 900 935 950 670 600 635 400 85630 1070 1000 1035 1200 920 850 885 460 95710 1170 1100 1135 1300 970 900 935 500 110TCDSize A B C D E F G H kg315 570 500 535 500 555 485 520 220 40355 670 600 635 700 662 592 627 280 65400 720 650 685 750 760 690 725 300 80450 770 700 735 800 820 750 785 330 110500 870 800 835 900 910 840 875 350 120560 970 900 935 950 970 900 935 400 160Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mWeightkgSPL dB referred to 10 -12 W Type D: ducted inlet/outlet (LW)63 125 250 500 1K 2K 4K 8KSCD280-4E 0.35 0.08 23 44 22 57 61 66 63 59 58 51 45SCD280-6E 0.35 0.08 17 37 22 50 54 60 56 51 50 46 40SCD/TCD315-4D 0.27 0.15 23 44 25 68 69 67 63 57 54 58 45SCD/TCD315-4DL 0.15 0.09 20 40 25 64 65 63 59 53 50 54 41SCD/TCD315-4E 0.9 0.13 22 46 25 68 73 67 65 59 55 59 47SCD/TCD315-6E 0.5 0.05 17 38 25 60 65 59 57 51 47 51 39SCD/TCD355-4D 0.49 0.3 22 48 35 68 73 71 68 61 58 55 49SCD/TCD355-4E 1.12 0.3 24 48 35 68 73 71 68 61 58 55 49SCD/TCD355-6D 0.25 0.1 18 39 35 59 64 62 59 52 49 46 40SCD/TCD355-6E 0.31 0.08 14 39 35 59 64 62 59 52 49 46 40SCD/TCD400-4D 1.41 0.5 24 52 45 69 78 75 72 64 61 60 58SCD/TCD400-4E 2.2 0.49 22 53 45 70 79 76 73 65 62 61 59SCD/TCD400-6D 0.7 0.29 21 42 45 69 69 66 61 57 49 48 36SCD/TCD400-6E 0.68 0.15 15 45 45 62 71 68 65 57 54 53 51SCD/TCD450-4D 1.3 0.51 21 54 57 69 78 78 74 67 64 65 55SCD/TCD450-4DL 0.66 0.36 17 45 57 60 69 69 65 58 55 56 46SCD/TCD450-4E 3 0.69 21 54 57 69 78 78 74 67 64 65 55SCD/TCD450-6D 0.75 0.29 16 47 57 62 71 71 67 60 57 58 48SCD/TCD450-6E 1.42 0.29 16 46 57 61 70 70 66 59 56 57 47SCD/TCD500-4D 3 1.42 23 58 65 71 81 82 77 72 68 64 63SCD/TCD500-4DL 1.35 0.78 19 52 65 65 75 76 71 66 62 58 57SCD/TCD500-4E 5.2 1.43 23 58 65 71 82 82 77 73 69 67 63SCD/TCD500-6D 1.1 0.47 16 47 65 71 71 72 64 62 55 52 45SCD/TCD500-6E 2.34 0.5 15 44 65 57 68 68 63 59 55 53 49SCD/TCD560-4D 5.8 2.44 23 62 85 78 90 88 80 75 71 66 64SCD/TCD560-4DL 1.8 0.96 16 53 85 69 81 79 71 66 62 57 55SCD/TCD560-6D 1.7 0.78 15 48 85 75 74 72 64 63 58 54 51SCD/TCD560-6E 3 0.79 13 46 85 74 74 71 62 61 56 53 49SCD630-4D 6.8 3.21 23 66 95 82 94 92 82 79 75 71 70SCD630-6D 2.8 1.31 15 56 95 72 84 82 72 69 65 61 60SCD710-6D 3.6 1.95 15 58 110 80 84 85 72 71 67 64 602E=2pole, 1phase. 2D=2 pole, 3phase, 4E=4 pole, 1Phase. 4D=4pole, 3phase. 6E=6pole, 1phase. 6D=6 pole, 3phase. 8D=8pole, 3phase.262 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 263


IMQ - Square Mixed Flow (TEFC)FANSCATALOGUEproductIMQ - Square Mixed Flow (TEFC)dimensions mm315 - 800poles & duty4 - 8 / up to 12,000 L/sapplicationDuct mounted mixed flow fans for general ventilation with low sound levelsIMQ SeriesThe IMQ series is a range of mixed flow inline duct mount fans for use ingeneral ventilation systems. The IMQ offers very low sound levels and istherefore ideal in applications such as hospitals, schools, residentialapartment buildings and hotels. All models are built around highperformance mixed flow impellers driven by TEFC motors.ConstructionCases are fabricated from galvanised sheet steel with standard duct flangesfor easy installation. Impellers are high efficiency mixed flow type. Theimpeller and motor assembly is supported by a robust triangulated steelframe for long, trouble free service.MotorsMotors are external TEFC designs incorporating sealed for life bearings. Motorenclosures feature IP54 protection in all models. Windings incorporate class‘B’ or class ‘F’ insulation as standard. Auto reset thermal contacts areprovided, either integrally wired or terminated at wiring connection bar. EXEand EXD models are available across the IMQ range.Suggested SpecificationMixed Flow duct mounted type fansshall be of the IMQ Seriesmanufactured by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.High performance mixed flowimpellers shall be driven by TEFCmotors with sealed for life bearings.Cases incorporating standardisedflanges to be of galvanised sheetsteel.All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.FeaturesHighly reliable TEFC motors with sealed for life ball bearings.High performance mixed flow impellers.Perfectly suited to medium/high volume and pressure applications.Fully speed controllable.<strong>Fans</strong> can be mounted at any angle.Very low sound levels.TestingRated fan performance has been determined by testing to BS848 Pt 1 (1998).Fan sound data has been determined by testing to DIN 45635.Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.Ancillaries264 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


700IMQ Series - 4 Pole1800IMQ Series - 4 PolePressure (Pa)600500400300200100315400500Pressure (Pa)1600140012001000800600400200630800000 500 1000 1500 2000 2500 3000 35000 2000 4000 6000 8000 10000 12000 14000Air Flow (L/s)Air Flow (L/s)800IMQ Series - 6 Pole450IMQ Series - 8 Pole700400Pressure (Pa)600500400300200100400500630800Pressure (Pa)35030025020015010050500630800000 2000 4000 6000 8000 100000 1000 2000 3000 4000 5000 6000 7000Air Flow (L/s)Air Flow (L/s)Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mSPL dB referred to 10 -12 W Type D: ducted inlet, outlet (LWi)63 125 250 500 1K 2K 4K 8KIMQ315-4DD 0.9 0.19 24 46 71 70 70 63 59 58 53 47IMQ400-4DD 1.8 0.59 24 55 76 76 76 72 71 68 62 57IMQ400-6DD 1 0.17 16 46 66 66 66 62 61 58 52 47IMQ500-4DD 0.9 1.98 24 64 83 81 83 80 80 76 72 66IMQ500-6DD 1.8 0.59 16 54 73 71 73 70 70 66 62 56IMQ500-8DD 1 0.25 12 47 66 64 66 63 63 59 55 49IMQ630-4DD 0.9 6.40 24 67 83 83 88 84 82 81 76 71IMQ630-6DD 1.8 1.90 16 58 73 73 78 74 72 71 66 61IMQ630-8DD 1 0.80 12 51 66 66 71 67 65 64 59 54IMQ800-4DD 1.1 19.41 24 76 90 91 98 94 90 88 85 81IMQ800-6DD 1.7 5.75 16 66 80 81 88 84 80 78 75 71IMQ800-8DD 3.4 2.43 12 59 73 74 81 77 73 71 68 64IMQSize A B C kg315 500 410 445 28.8400 550 500 535 38.8500 650 650 685 57.7560 750 700 735 71.7630 800 800 835 95.7800 850 1000 1035 1302E=2pole, 1phase. 2D=2 pole, 3phase, 4E=4 pole, 1Phase. 4D=4pole, 3phase. 6E=6pole, 1phase. 6D=6 pole, 3phase. 8D=8pole, 3phase.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 265


FANSCATALOGUEWall Mounted <strong>Fans</strong>266 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


RPA Series - ring plate axial268WQ/WR wall & ceiling axial ERM270WQWRWAE/S wall axial exhaust/supply271SP/DP square plate adjustable pitchaxial272SPDP© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 267


FANSCATALOGUERPA Series - ring plate axialRPAThe RPA series is a range of ceiling or wall mount fans featuring external rotormotors and sickle blade impellers for very quiet operation. Ideally suited tocommercial and industrial ventilation applications where an attractivelystyled ring plate type fan is required. The fans have a cylindrical body designfor direct connection to ductwork. <strong>Fans</strong> can be mounted at any angle.ConstructionCases and grille are of powder coated steel. Motor supports are of corrosionprotected steel. Available in optional Colorbond colours.MotorsMotor windings incorporate ‘F’ insulation as standard. Motor bearings aresealed for life and maintenance free. Auto-reset thermal contacts areprovided.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN 45635Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.Suggested SpecificationRing Plate Axial Flow type fans shall beof the RPA Series manufactured by<strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Sickle blade axial impellers shall bedriven by external rotor motors withsealed for life bearings. Cases andgrilles to be of corrosion protectedpowder coat steel.All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.4RPASize A B C D F E G kg200 255 231 202 145 10 162 4 2.5250 306 282 256 145 10 188 4 6300 360 336 310 170 10 215 4 7350 420 395 356 170 10 245 8 9Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mWeightkgSPL dB referred to 10 -12 W Type D: ducted outlet (LW)63 125 250 500 1K 2K 4K 8KRPA200-2E 0.3 0.06 45 49 3 - 55 62 68 64 62 57 51RPA200-4E 0.21 0.03 23 37 2.5 - 57 54 57 54 47 40 39RPA250-2E 0.51 0.115 41 51 3.7 - 56 63 70 68 61 57 50RPA250-4E 0.53 0.069 23 38 3.4 - 55 55 57 54 48 39 36RPA300-2E 0.62 0.14 45 60 4.6 - 64 73 77 77 74 69 63RPA300-4E 0.3 0.068 23 47 4.2 - 66 66 65 64 59 49 40RPA300-6E 0.16 0.035 16 38 4.2 - 57 57 56 55 50 40 31RPA350-4E 0.58 0.13 23 47 4.2 - 73 65 62 61 60 58 50RPA350-6E 0.32 0.073 16 38 4.2 - 64 56 53 52 51 49 41268 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


RPA Series - ring plate axialRPA Series - 2 PolePressure (Pa)1801601401201008060402002503002000 100 200 300 400 500 600 700Air Flow (L/s)RPA Series - 4 Pole120100Pressure (Pa)806040200300350200 2500 200 400 600 800 1000Air Flow (L/s)RPA Series - 6 PolePressure (Pa)504540353025201510530035000 100 200 300 400 500 600 700Air Flow (L/s)Ancillaries© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 269


FANSCATALOGUEWQ/WR wall & ceiling axial ERMWQ/WRThe WQ/WR series offers reliable performance in commercial and horticulturalexhaust air applications. Both ranges are suitable for installation at any anglethanks to the use of high quality sealed for life ball bearing type motors. Thefans are inherently low noise and can be fully speed controlled.WQConstructionThe range is fitted with either aerofoil or sickle blade axial impellers driven byexternal rotor motors with sealed for life bearings. Motors are single phase intwo and four pole speeds. Cases are fabricated from corrosion protectedsteel with powder coat finish.WRFeaturesFully speed controllable.High reliability external rotor motors.<strong>Fans</strong> can be mounted at any angle.Available in optional Colorbond colours.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN45635Suggested SpecificationAxial Flow wall mount type fans shallbe of the WQ/WR Seriesmanufactured by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auAerofoil section or sickle bladeimpellers shall be driven by externalrotor motors with sealed for lifebearings.160WQ/WR -2 Pole140WQ/WR -4 PoleAll fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.Pressure (Pa)14012010080604020200250300Pressure (Pa)1201008060402020025030000 200 400 600 800Air Flow (L/s)00 100 200 300 400 500Air Flow (L/s)WQSize A B C D E F G H kg200 312 260 202 75 46 6 7 215 1.8250 370 320 256 90 49 6 7 265 2.3300 430 380 304 135 71 11 9 330 2.8WRSize A B C D E F G kg200 280 245 200 80 9 6 7 1.7250 320 290 254 85 9 6 7 2.2300 397 380 326 80 10 11 9 2.7Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mWeightkgSPL dB referred to 10 -12 W Type A: free inlet/ outlet (LW)63 125 250 500 1K 2K 4K 8KWQ/WR200-2E 0.24 0.05 46 52 1.7 - 45 52 64 65 67 68 60WQ/WR200-4E 0.3 0.04 23 28 3.5 - 36 43 45 45 44 36 28WQ/WR250-2E 0.51 0.12 42 57 2.2 - 51 62 69 72 70 73 65WQ/WR250-4E 0.53 0.07 23 45 4.5 - 48 62 59 60 60 59 48WQ/WR300-2E 0.62 0.14 44 60 2.7 - 63 76 79 74 74 72 67WQ/WR300-4E 0.44 0.1 23 52 6 - 56 62 65 67 69 65 59270 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


WAE/S wall axial exhaust/supplyWAE/SThe WAE/S series offers reliable performance in commercial and horticulturalexhaust or supply air applications. Suitable for wall installation providing goodair flow performance against medium level pressures. The fans are inherentlylow noise and can be fully speed controlled.ConstructionThe range is fitted with either aerofoil or sickle blade axial impellers driven byexternal rotor motors with sealed for life bearings. Motors are single or threephase in four and six pole speeds. Cases are fabricated from corrosionprotected steel.FeaturesFully speed controllable.High reliability external rotor motors.Available in optional Colorbond colours.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN45635Suggested SpecificationAxial Flow wall mount type fans shallbe of the WAE/S Series manufacturedby <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auAerofoil section or sickle bladeimpellers shall be driven by externalrotor motors with sealed for lifebearings.All fans shall be fully tested inaccordance with the requirements ofDIN24163 1998 for air flow andDIN45635 for sound.Pressure (Pa)WAE/S - 4 Pole30025020015010063050050 40056045035000 1000 2000 3000 4000 5000 6000Air Flow (L/s)Pressure (Pa)WAE/S - 6 Pole140120100806040630 (6D)630 (6E)2045040000 750 1500 2250 3000 3750Air Flow (L/s)WAE / WASSize A B C D E F G kg350 485 435 368 87 75 12 9 7400 540 490 412 100 88 12 9 9450 575 535 463 110 96 14 11 11500 655 615 517 120 104 16 11 15560 725 675 568 136 120 16 11 17630 805 750 643 150 130 20 11 28Fan ModelFull LoadCurrentMotor kWdB(A)@ 3mSPL dB referred to 10 -12 W Type A: free inlet/ outlet (LW)63 125 250 500 1K 2K 4K 8KWAE/S350-4E 0.58 0.137 46 - 64 75 56 56 56 49 43WAE/S400-4E 0.73 0.16 52 - 75 70 70 69 66 62 56WAE/S400-4D 0.53 0.29 52 - 75 70 70 69 66 62 56WAE/S400-6D 0.31 0.19 41 - 64 59 59 58 55 51 45WAE/S450-4E 2.36 0.49 48 - 70 68 63 62 63 62 54WAE/S450-4D 0.98 0.48 50 - 69 65 64 64 66 64 56WAE/S450-6D 0.58 0.34 74 95 92 90 89 90 88 87 80WAE/S450-6D 0.58 0.34 39 - 58 54 53 53 55 53 45WAE/S500-4D 0.8 0.48 54 - 69 68 68 68 70 68 60WAE/S500-4E 3 0.68 54 - 72 70 68 68 70 68 60WAE/S560-4D 1.95 1.16 69 - 71 70 70 70 69 68 91WAE/S560-6D 1.1 0.65 48 - 74 60 61 61 60 54 49WAE/S630-4D 4.78 2.63 58 - 76 76 77 74 71 67 63WAE/S630-6E 2.62 0.6 49 - 78 64 65 65 63 61 57WAE/S630-6D 2.95 1.75 47 - 64 64 64 63 62 58 56© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 271


SP/DP square plate adjustable pitch axialFANSCATALOGUEproductSP/DP - Square Plate Adjustable Pitch Axialdimensions mm400 - 1000poles & duty2 - 8 / up to 16,000 L/sSPapplicationA comprehensive range of wall plate fans suitable for supply or exhaustventilation. Models available for Smoke Spill ApplicationsSpecificationsCasings for all models are of hot dipped galvanised steel construction withbell mouth inlets for improved air flow. Motor mountings are fabricated fromheavy duty galvanised steel.DPSuggested SpecificationAxial Flow wall mount type fans shallbe of the SP/DP Series manufacturedby <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Aerofoil section or sickle bladeimpellers shall be driven by TEFCmotors with sealed for life bearings.TestingRated fan performance has been determined by testing to ISO 5801 Pt1(1997) and BS848 Pt1 (1998). Fan sound data has been determined by testingto AMCA 300.ImpellersAdjustable pitch impellers consist of hubs manufactured from pressure diecast aluminium alloy. Blades are of special aerofoil section giving excellentperformance and low noise characteristics. Blade materials include injectionmoulded glass reinforced polypropylene (GRP), nylon or pressure castaluminium. Impellers are balanced to ISO1940 Grade G6.3.MotorsMotors are of TEFC design. Motor enclosure features IP54 protection. Motorwindings incorporate class ‘ F’ insulation as standard although class ‘ H’ isreadily available. Motor bearings are sealed for life and maintenance free.Auto-reset thermal contacts are generally provided, either integrally wired orterminated at wiring connection bar.Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.FeaturesHeavy duty construction.Inlet guards fitted as standard.Bell inlet designs for maximised performance.Wide range of sizes and motor configurationsLow noise adjustable pitch impellersSealed for life ball bearingsAvailable in Form A or Form B flow versions.Available in optional Colorbond colours.AncillariesAll fans shall be fully tested inaccordance with the requirements ofBS848 Pt1 (1998). for air flow andAMCA 300 for sound.272 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


SP Envelopes By Ø and Motor SpeedPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performanceenvelopes have been grouped by motor speed for each fan model’s available diameter. Note that scales for all charts arelinear. We strongly recommend that these curves be used as a guide only. For detailed performance capability refer to our fanselection software <strong>Fans</strong>Select available for free <strong>download</strong> at www.fansdirect.com.auSP Adjustable Pitch - 400mm5004002 PoleSPPressure (Pa)3002004 Pole6 Pole1008 Pole00 0.5 1 1.5 2 2.5 3 3.5Air Flow (m3/s)600SP Adjustable Pitch - 500mmPressure (Pa)5004003002001002 Pole4 Pole6 Pole8 Pole00 1 2 3 4 5 6Air Flow (m3/s)800SP Adjustable Pitch - 560mmPressure (Pa)7006005004003002001002 Pole4 Pole6 Pole8 Pole00 1 2 3 4 5 6 7 8Air Flow (m3/s)800SP Adjustable Pitch - 630mmPressure (Pa)7006005004003002001002 Pole4 Pole6 Pole8 Pole00 2 4 6 8 10 12Air Flow (m3/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 273


SP/DP Envelopes By Ø and Motor SpeedFANSCATALOGUEPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performanceenvelopes have been grouped by motor speed for each fan model’s available diameter. Note that scales for all charts arelinear. We strongly recommend that these curves be used as a guide only. For detailed performance capability refer to our fanselection software <strong>Fans</strong>Select available for free <strong>download</strong> at www.fansdirect.com.au350SP Adjustable Pitch - 710mm3002504 PoleSPPressure (Pa)2001501006 Pole508 Pole00 2 4 6 8 10Air Flow (m3/s)Pressure (Pa)SP Adjustable Pitch - 800mm4504004 Pole3503002502001506 Pole1008 Pole5000 2 4 6 8 10 12 14Air Flow (m3/s)DPPressure (Pa)DP Adjustable Pitch - 800mm4504004 Pole3503002502001506 Pole1008 Pole5000 2 4 6 8 10 12 14Air Flow (m3/s)Pressure (Pa)DP Adjustable Pitch - 900mm4504003504 Pole3002502001506 Pole100508 Pole00 5 10 15 20Air Flow (m3/s)274 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


DP Envelopes By Ø and Motor SpeedDPPressure (Pa)DP Adjustable Pitch - 1000mm5004504004 Pole3503002502001506 Pole1008 Pole5000 5 10 15 20 25 30Air Flow (m3/s)SPSize A B C *D E F G *kg400 540 490 406 395 88 12 9 38500 655 615 508 415 104 16 11 43560 725 675 564 415 104 16 11 45630 805 750 639 430 130 20 11 48710 850 810 715 470 150 20 14.5 61800 970 910 801 605 190 20 14.5 85*Based on maximum size.DPSize A B C D E F900 1070 1010 900 630 970 10001000 1170 1110 1000 630 1100 1100© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 275


FANSCATALOGUEAir Relief Cowls276 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


MAD Series Cowls 278VCQ Series Cowls 279VCV Series Cowls 280© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 277


FANSCATALOGUEMAD Series CowlsMADRoof cowls are designed to provide a weatherproof opening in ductedsystems to the outside of buildings. MAD models provide a range of sizes andcapacities to suit smaller diameter ducting in either supply or exhaust airconfiguration.ConstructionThe range is manufactured from galvanised sheet steel and spun aluminium.Each model is bird proof with formed barriers or high strength anti-bird mesh.FeaturesLow profile, attractive designFully weather proofCan be mounted at angles of up to 30°Durable constructionBird proofAvailable in optional Colorbond colours.TestingAerodynamic performance has been determined by testing to DIN241631998.DataRefer to the latest product datasheet for individual model specification.Datasheets are available from our electronic selection software <strong>Fans</strong>Select<strong>download</strong>able at www.fansdirect.com.auSuggested SpecificationAir Relief Cowls shall be of the MADSeries manufactured by <strong>Fans</strong> <strong>Direct</strong>Pty LtdCowls shall be constructed fromaluminium / galvanised steel andincorporate bird mesh as part of thedesign.All cowls shall be fully tested foraerodynamic performance inaccordance with the requirements ofDIN24163 (1998).Size A B C DMAD100 171 100 150 60MAD150 235 150 167 77MAD200 327 200 175 85MAD250 407 250 202 112MAD300 500 300 229 139220MAD Series10070Pressure (Pa)4020MAD100MAD150MAD200MAD250MAD3001020 50 100 200 300 500 700Air Flow (L/s)278 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


VCQ Series CowlsVCQRoof cowls are designed to provide a weatherproof opening in ductedsystems to the outside of buildings. VCQ models provide a range of sizes andcapacities to suit almost any specification in either supply or exhaust airconfiguration.(VCQ-1-6)(VCQ-0)ConstructionThe range is manufactured from a combination of UV stabilised polymer,corrosion protected steel and fibreglass. Each model is bird proof withmoulded in barriers or high strength anti-bird mesh.FeaturesLow profile, attractive designFully weather proofCan be mounted at angles of up to 30°Durable constructionBird proofAvailable in optional Colorbond colours.TestingAerodynamic performance has been determined by testing to DIN241631998.DataRefer to the latest product datasheet for individual model specification.Datasheets are available from our electronic selection software <strong>Fans</strong>Select<strong>download</strong>able at www.fansdirect.com.auSuggested SpecificationAir Relief Cowls shall be of the VCQSeries manufactured by <strong>Fans</strong> <strong>Direct</strong>Pty Ltd.Cowls shall be constructed fromgalvanised steel, UV resistant ABSpolymer and fibreglass. Units shallincorporate bird mesh as part of thedesign.All cowls shall be fully tested foraerodynamic performance inaccordance with the requirements ofDIN24163 (1998).Size A B C D E KgVCQ-0 260 210 310 210 50 0.5VCQ-1 380 330 430 195 25 3VCQ-2 530 440 550 250 50 8VCQ-3 715 615 900 340 80 15VCQ-4 840 740 1100 390 80 25VCQ-5 960 810 1100 420 80 30VCQ-6 1160 1010 1400 445 80 55220VCQ Series10070Pressure (Pa)4020VCQ-0VCQ-1VCQ-2VCQ-3VCQ-4VCQ-5VCQ-61050 100 200 750 1500 2500 5000 10000Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 279


VCV Series Cowls (400-1000Ø)FANSCATALOGUEVCVRoof cowls are designed to provide a weatherproof opening in ductedsystems to the outside of buildings. VCV models provide a range of sizes andcapacities to suit almost any specification.ConstructionThe range is manufactured from galvanised steel and aluminium. Metalbutterfly weather shields are air operated. Magnetic catches, and fail-opendevice for smoke spill applications are available as options.FeaturesFully weather proofCan be mounted at angles of up to 30°Durable constructionSmoke spill compatibleAvailable in optional Colorbond colours.TestingAerodynamic performance has been determined by testing to DIN241631998.DataRefer to the latest product datasheet for individual model specification.Datasheets are available from our electronic selection software <strong>Fans</strong>Select<strong>download</strong>able at www.fansdirect.com.auSuggested SpecificationAir Relief Cowls shall be of the VCVSeries manufactured by <strong>Fans</strong> <strong>Direct</strong>Pty Ltd.Cowls shall be constructed fromaluminium and galvanised or powdercoated steel.All cowls shall be fully tested foraerodynamic performance inaccordance with the requirements ofDIN24163 (1998).VCV A B C D E Kg400 530 440 480 315 50 20500 645 545 556 445 80 26560 715 615 626 445 80 30630 795 695 686 511 80 35710 840 740 776 515 80 40800 960 810 816 635 80 551000 1160 1010 1034 635 80 70250200VCV Series (400 - 1000Ø)10070Pressure (Pa)4020VCV400VCV500VCV560VCV630VCV710VCV800VCV100010550 750 1500 2500 5000 10000 22000Air Flow (L/s)280 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


VCV Series Cowls (1120-1500Ø)Size A B C D E F KgVCV1120 1420 1270 1340 770 80 815 125VCV1250 1550 1400 1560 920 80 770 180VCV1400 1750 1550 1700 920 80 815 365VCV1500 1850 1650 1830 920 80 615 380VCV Series (1120 - 1500Ø)200100Pressure (Pa)7040VCV1120VCV1250VCV1400VCV1500206500 8500 10000 15000 20000 30000 40000 50000Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 281


FANSCATALOGUESmoke Spill <strong>Fans</strong>282 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Smoke Spill <strong>Fans</strong><strong>Fans</strong> <strong>Direct</strong> manufactures a comprehensive range of smoke spill fans in sizesand configurations to meet most applications. Rigorous testing ensures thatall fans designated for smoke spill applications have been certified to meetthe required levels of performance specified in the relevant standards.AXConstruction<strong>Fans</strong> for smoke spill applications are generally manufactured from hotdipped galvanised steel although in some cases wind bands may be ofpowder coated steel. Impeller blades and hubs are manufactured fromaluminium using a pressure die casting process to ensure uniform quality andperformance.VDTestingThe performance of <strong>Fans</strong> <strong>Direct</strong> Smoke Spill fans has been determined bytesting in accordance with the requirements of AS4429(Int)-1996 andAS4429:1999. The fans comply with requirements of AS/NZS1668.1:1998Time and Temperature Ratings· 200⁰C for 120 minutesLE· 300⁰C for 30 minutesThe following pages detail the ranges of smoke spill fans with specificinformation relating to impeller configurations and maximum rotationalspeeds.DPFailsafe Damper SystemTo comply with requirements of smoke spill fans operating in unsprinkleredbuildings, <strong>Fans</strong> <strong>Direct</strong> is able to offer discharge damper failsafe modelsincorporating highly reliable mechanisms with temperature activated fusiblelinks.Available RangesSP· AX Long Cased Adjustable Pitch Axial (Duct Mount)· VD Roof Mount Adjustable Pitch Axial· LE Roof Mount Adjustable Pitch Axial· DP Adjustable Pitch Axial Square Plate (wall mount)· SP Adjustable Pitch Axial Square Plate (wall mount)Selecting Smoke Spill <strong>Fans</strong>To access the full range of smoke spill fans offered by <strong>Fans</strong> <strong>Direct</strong> and toselect the right fan type any given situation please refer to our electronic fanselection software, <strong>Fans</strong>Select, available for <strong>download</strong> atwww.fansdirect.com.auYour local <strong>Fans</strong> <strong>Direct</strong> sales office is equipped to answer specific queriesrelating to the full range of smoke spill fans.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 283


FANSCATALOGUESmoke Spill <strong>Fans</strong>SeriesRatingsCertificate of ComplianceAX Long Cased Adjustable Pitch Axial200⁰C for 120 minutes; 300⁰C for 30 minutesSSFFD-1-300810ModelNom. Diameter*mmHub DiametermmNo. BladesMax. Speed(rpm)AX 310-500 150 5-10 2880AX 310-800 150 5-10 1440AX 560-1000 250 7-14 1440AX 560-1120 250 7-14 960AX 710-1000 255 3-6-12 1440AX 710-1250 255 3-6-12 960AX 800-1000 330 4-8-12-16 1440AX 800-1250 330 4-8-12-16 960AX 800-1250 400 4-8-12-16 1440AX 800-1600 400 4-8-12-16 960*Minimum tip clearance is 1.5% of Nominal Diameter.SeriesRatingsCertificate of ComplianceVD Roof Mount Adjustable Pitch Axial200⁰C for 120 minutes; 300⁰C for 30 minutesSSFFD-3-310810ModelNom. Diameter*mmHub DiametermmNo. BladesMax. Speed(rpm)VD 310-500 150 5-10 2880VD 310-800 150 5-10 1440VD 560-1000 250 7-14 1440VD 560-1120 250 7-14 960VD 710-1000 255 3-6-12 1440VD 710-1250 255 3-6-12 960VD 800-1000 330 4-8-12-16 1440VD 800-1250 330 4-8-12-16 960VD 800-1250 400 4-8-12-16 1440VD 800-1600 400 4-8-12-16 960*Minimum tip clearance is 1.5% of Nominal Diameter.SeriesRatingsCertificate of ComplianceLE Roof Mount Adjustable Pitch Axial200⁰C for 120 minutes; 300⁰C for 30 minutesSSFFD-2-300810ModelNom. Diameter*mmHub DiametermmNo. BladesMax. Speed(rpm)LE 310-500 150 5-10 2880LE 310-800 150 5-10 1440LE 560-1000 250 7-14 1440LE 560-1120 250 7-14 960LE 710-1000 255 3-6-12 1440LE 710-1250 255 3-6-12 960LE 800-1000 330 4-8-12-16 1440LE 800-1250 330 4-8-12-16 960LE 800-1250 400 4-8-12-16 1440LE 800-1600 400 4-8-12-16 960*Minimum tip clearance is 1.5% of Nominal Diameter.284 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Smoke Spill <strong>Fans</strong>SeriesRatingsCertificate of ComplianceDP Adjustable Pitch Axial Square Plate200⁰C for 120 minutes; 300⁰C for 30 minutesSSFFD-4-310810ModelNom. Diameter*mmHub DiametermmNo. BladesMax. Speed(rpm)DP 310-500 150 5-10 2880DP 310-800 150 5-10 1440DP 560-1000 250 7-14 1440DP 560-1120 250 7-14 960DP 710-1000 255 3-6-12 1440DP 710-1250 255 3-6-12 960DP 800-1000 330 4-8-12-16 1440DP 800-1250 330 4-8-12-16 960DP 800-1250 400 4-8-12-16 1440DP 800-1600 400 4-8-12-16 960*Minimum tip clearance is 1.5% of Nominal Diameter.SeriesRatingsCertificate of ComplianceSP Adjustable Pitch Axial Square Plate200⁰C for 120 minutes; 300⁰C for 30 minutesSSFFD-5-310810ModelNom. Diameter*mmHub DiametermmNo. BladesMax. Speed (rpm)SP 310-500 150 5-10 2880SP 310-800 150 5-10 1440SP 560-1000 250 7-14 1440SP 560-1120 250 7-14 960SP 710-1000 255 3-6-12 1440SP 710-1250 255 3-6-12 960SP 800-1000 330 4-8-12-16 1440SP 800-1250 330 4-8-12-16 960SP 800-1250 400 4-8-12-16 1440SP 800-1600 400 4-8-12-16 960*Minimum tip clearance is 1.5% of Nominal Diameter.Suggested SpecificationSmoke Spill type fans shall be of theAX, VD,LE,DP,SP [delete as required]Series manufactured by <strong>Fans</strong> <strong>Direct</strong>Pty LtdAncillaries<strong>Fans</strong> shall be constructed frompressure die cast aluminium andgalvanised or powder coated steel.All fans shall be fully tested inaccordance with the requirements ofAS4429(Int)-1996, AS4429:1999 and AS/NZS1668.1:1998© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 285


FANSCATALOGUEBushfire Code Compliant<strong>Fans</strong> & Cowls286 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


BRCR Series - roof centrifugal 289BKMV Vertical Discharge Centrifugal 290BMVC All Metal Vertical DischargeCentrifugal292BVCQ Series Cowls 294© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 287


Bushfire Code Compliant <strong>Fans</strong> and CowlsFANSCATALOGUE<strong>Fans</strong> <strong>Direct</strong> offers a range of fans and cowls specifically designed to complywith the requirements of AS 3959-2009 Construction Of Buildings In Fire ProneAreas up to and including BAL-40. <strong>Fans</strong> <strong>Direct</strong> does not offer products forgeneral specification or sale suitable for use in areas assessed as BAL-FZ.Bush Fire AttackLevelBAL – LOWBAL – 12.5BAL – 19BAL – 29BAL – 40BAL – FZDescription of predicted bushfire attack and levels ofexposureThere is insufficient risk to warrant specific constructionrequirements.Ember attackIncreasing levels of ember attack and burning debrisignited by windborne embers together with increasingheat flux between 12.5 and 19 kW m 2Increasing levels of ember attack and burning debrisignited by windborne embers together with increasingheat flux between 19 and 29 kW m 2Increasing levels of ember attack and burning debrisignited by windborne embers together with increasingheat flux 29-40kW m 2 , with the increased likelihood ofexposure to flames<strong>Direct</strong> exposure to flames from fire front in addition toheat flux and ember attackConstructionSection 8 of AS3959-2009 concerns the design requirements for buildingelements at BAL-40. Although fans and cowls are not specifically referred toin the standard, we have taken the design requirements for wall and roofstructures generally and applied these to our range of bushfire compliantproducts. Section 8.6.1of AS3959-2009 states:a. Roof tiles, roof sheets, and roof-covering accessories shall be noncombustible.c. Roof ventilation openings, such as gable and roof vents, shall be fittedwith ember guards made of non-combustible material or a mesh orperforated sheet with a maximum aperture of 2mm, made of corrosion-resistant steel or bronze.d. A pipe or conduit that penetrates the roof covering shall be noncombustible.All <strong>Fans</strong> <strong>Direct</strong> bushfire compliant fans and cowls are manufactured usingheavy gauge galvanised steel (in some instances powder coated) withopenings to the interior sealed against ember attack with 1.8mm or 2mmbronze or stainless steel mesh.Design ConsiderationsThe performance data specified for each bushfire compliant model isnominal and will be affected by varying motor types and the use of varyingtypes of speed control.Owing to the potential for debris build up against ember protection meshbetween routine inspections and servicing, designers are advised to makeadequate allowance for accumulating pressure losses in their selections.288 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


BRCR Series - roof centrifugal Bushfire CompliantBRCR Tube MountBRCR Curb MountBRCRThe BRCR range of roof mounted fans is designed for ventilation applicationsincluding domestic kitchen hood extraction where lowest possible noise levelsare required. The fans meet the requirements of AS 3959-2009 up to BAL-40.ConstructionThe range is fitted with backward curved centrifugal impellers driven byexternal rotor motors with sealed for life bearings. External components aremade from corrosion protected powder coat steel. Ember penetration isprevented with stainless steel mesh with a maximum aperture of 2mm.Available in optional Colorbond colours.<strong>Fans</strong> are available in tube mount or curb mount configuration.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to AMCA 300 1996WiringThree pin plug. Datasheets are available from our electronic selectionsoftware <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auRCR150-ABRCR150-ARCR200-B & RCR200-CBRCR200-B & BRCR200-C350500300450400250350Design ConsiderationsOwing to the potential for debris buildup against ember protection meshbetween routine inspections andservicing, designers are advised tomake adequate allowance foraccumulating pressure losses in theirselections.Pa2001501005000 25 50 75 100 125 150L/sPa300250200-C200150 200-B1005000 50 100 150 200 250 300L/sSuggested SpecificationBushfire Code Compliant(to maximum BAL-40) Roof MountedExhaust type fans shall be of the BRCRSeries manufactured by <strong>Fans</strong> <strong>Direct</strong>Pty Ltd.BRCRSize A B(I/D) C kg150 300 150 220 3.2Backward curved impellers shall bedriven by external rotor motors withsealed for life bearings. Emberpenetration shall be prevented by theinstallation of stainless steel mesh witha maximum aperture of 2mm.200 400 200 240 5.2The fans shall meet the designrequirements of AS 3959-2009 up toBAL-40.BRCR Curb BaseSize A B C kg150 170 240 55 -200 270 340 55 -Note: Add dimension 'C’ Curb Base to fan Dimension ’C’ foroverall assembly height.Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mSound Power Spectrum dB referred to 10 -12 watts63 125 250 500 1K 2K 4K 8KBRCR150-A 0.36 0.08 40 47 50 64 59 65 61 63 59 50BRCR200-B 0.53 0.12 43 48 50 61 63 66 64 61 62 48BRCR200-C 0.73 0.16 44 54 55 62 77 69 70 68 60 51© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 289


FANSCATALOGUEBKMV Vertical Discharge Centrifugal Bushfire CompliantproductBKMV Vertical Discharge Centrifugaldimensions mm315 - 710poles & duty4 - 8 / up to 4,600 L/sapplicationA roof mounted motor out of air stream centrifugal range ideal for kitchenextract and general ventilation with bushfire compliant construction.BKMV SeriesThe BKMV series is a range of high performance all metal fans for use inkitchen exhaust and general ventilation applications. Motors are mountedout of the air stream and wind bands are secured with clip fasteners to alloweasy access for servicing and cleaning. The fans meet the requirementsof AS 3959-2009 up to BAL-40ConstructionFabricated from galvanised steel in compliance with AS/NZS1668.1:1998.High performance backward curved centrifugal impellers are driven by TEFCmotors incorporating sealed for life bearings. Ember penetration is preventedwith stainless steel mesh with a maximum aperture of 2mm. Available inoptional Colorbond colours.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN 45635Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is a condition of our warranty that all equipment supplied is installedaccording to the requirements of AS/NZS3000:2007.BKMVSize A B C D E Fkg310 410 310 50 600 355 545 45350/400 500 400 50 690 450 600 50/55450/500/560 720 620 60 915 585 755 75/85/90630/710 810 710 60 1135 655 865 120/150Fan ModelFull LoadCurrentMotor kW Shaft Revs /sec290 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326dB(A)@ 3mSound Power Level dB referred to 10 -12 W Type C: ducted inlet, free out (LWi)63 125 250 500 1K 2K 4K 8KBKMV315-4DD 0.9 0.37 24 47 77 75 69 66 59 55 55 51BKMV315-4ED 1.8 0.37 24 47 77 75 69 66 59 55 55 51BKMV315-6DD 1 0.37 16 41 67 69 60 60 54 51 46 42BKMV355-4DD 0.9 0.37 24 51 75 78 72 71 61 63 59 52BKMV355-4ED 1.8 0.37 24 51 79 78 72 71 61 63 59 52BKMV355-6DD 1 0.37 16 43 65 69 64 63 58 51 46 44BKMV400-4DD 0.9 0.37 24 54 79 81 75 73 66 66 65 58BKMV400-4ED 1.8 0.37 24 54 79 81 75 73 66 66 65 58BKMV400-6DD 1 0.37 16 45 70 72 67 63 58 55 52 47BKMV400-8DD 1.1 0.37 12 38 63 65 60 56 51 48 45 40BKMV450-4DD 1.7 0.75 24 57 78 81 77 75 69 69 67 63BKMV450-4ED 3.4 0.75 24 57 78 81 77 75 69 69 67 63BKMV450-6DD 1.1 0.37 16 47 74 75 68 65 59 58 55 50BKMV450-8DD 1.2 0.37 12 40 67 68 61 58 52 51 48 43BKMV500-4DD 2.4 1.1 24 60 81 85 81 76 74 74 69 71BKMV500-4ED 4.8 1.1 24 60 81 85 81 76 74 74 69 71BKMV500-6DD 1 0.37 16 50 74 80 72 66 63 61 58 55BKMV500-8DD 1.1 0.37 12 43 67 73 65 59 56 54 51 48BKMV560-4DD 4.4 2.2 24 65 86 93 88 80 78 78 73 72BKMV560-6DD 1.7 0.55 16 54 78 82 75 70 66 66 62 61BKMV560-8DD 1.1 0.37 12 44 70 72 66 60 58 56 55 50BKMV630-4DD 7.7 4 24 69 90 97 90 83 83 81 80 75BKMV630-6DD 2.6 1.1 16 57 81 85 78 72 71 68 66 65BKMV630-8DD 1.7 0.55 12 49 70 75 70 65 64 60 60 56BKMV710-6DD 4.8 2.2 16 61 85 90 86 75 73 71 70 68BKMV710-8DD 2.1 0.75 12 47 72 75 72 61 61 57 56 53


BKMV Vertical Discharge Centrifugal Bushfire CompliantDesign ConsiderationsOwing to the potential for debris buildup against ember protection meshbetween routine inspections andservicing, designers are advised tomake adequate allowance foraccumulating pressure losses in theirselections.Suggested SpecificationBushfire Code Compliant(to maximum BAL-40) Roof MountedExhaust type fans shall be of the BKMVSeries manufactured by <strong>Fans</strong> <strong>Direct</strong>Pty LtdBackward curved impellers shall bedriven by out of air stream TEFC motorswith sealed for life bearings. Emberpenetration shall be prevented by theinstallation of stainless steel mesh witha maximum aperture of 2mm.The fans shall meet the designrequirements of AS 3959-2009 up toBAL-40.Pressure (Pa)Pressure (Pa)BKMV - - 44 Pole60050040030020045040010035531500 500 1000 1500 2000Air Flow (L/s)BKMV - - 4Pole 4 1200100080060063040056050020000 1000 2000 3000 4000 5000Air Flow (L/s)Ancillaries700600BKMV - 6 PolePressure (Pa)50040030071020063010056045050035540031500 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Air Flow (L/s)350BKMV - - 88 PolePressure (Pa)3002502001501007106305605040045050000 500 1000 1500 2000 2500 3000 3500 4000Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 291


FANSCATALOGUEBMVC All Metal Vertical Discharge Centrifugal Bushfire CompliantproductBMVC All Metal Vertical Discharge Centrifugaldimensions mm315 - 710poles & duty4 - 6 / up to 3,700 L/sapplicationA robust centrifugal range ideal for kitchen extract ventilation with bushfirecode compliance.BMVC SeriesThe BMVC series is a range of high performance all metal fans for use inkitchen exhaust and general ventilation applications. Wind bands havebeen designed to allow easy cleaning of internal surfaces. The fans meet therequirements of AS 3959-2009 up to BAL-40.ConstructionBase and windband are fabricated from galvanised steel in compliance withAS/NZS1668.1:1998. The impeller and motor assembly is supported by arobust galvanised steel frame for long, trouble free service. All externalcomponents are made from galvanised sheet steel. Ember penetration isprevented with stainless steel mesh with a maximum aperture of 2mm.Available in optional Colorbond colours.TestingRated fan performance has been determined by testing to DIN24163 1998.Fan sound data has been determined by testing to DIN 45635Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select <strong>download</strong>able at www.fansdirect.com.auIt is a condition of our warranty that all equipment supplied is installedaccording to the requirements of AS/NZS3000:2007.BMVCSize A B C D E kg630/710 805 700 810 795 80 110500/560 680 580 685 685 80 53400/450 555 460 560 555 80 33315/355 505 400 510 505 80 25Fan ModelFull LoadCurrentMotor kWShaft Revs /secdB(A)@ 3mSound Power Level dB referred to 10 -12 W Type C: ducted inlet, free out (LWi)63 125 250 500 1K 2K 4K 8KBMVC315-4D 0.27 0.13 23 44 68 69 67 63 57 54 58 45BMVC315-4E 0.9 0.17 22 46 68 73 67 65 59 55 59 47BMVC355-4D 0.49 0.27 22 48 68 73 71 68 61 58 55 49BMVC355-6D 0.1 0.09 18 39 59 64 62 59 52 49 46 40BMVC400-4D 1.41 0.52 24 52 69 78 75 72 64 61 60 58BMVC400-6D 0.7 0.39 21 42 69 69 66 61 57 49 48 36BMVC400-6E 0.8 0.17 15 45 62 71 68 65 57 54 53 51BMVC450-4D 1.3 0.69 20 54 69 78 78 74 67 64 65 55BMVC450-6D 0.75 0.29 16 47 62 71 71 67 60 57 58 48BMVC450-6E 1.42 0.3 16 46 61 70 70 66 59 56 57 47BMVC500-4D 3 1.41 23 58 71 81 82 77 72 68 64 63BMVC500-4E 5.2 1.43 23 58 71 82 82 77 73 69 67 63BMVC500-6D 1.1 0.48 16 47 71 71 72 64 62 55 52 45BMVC560-4D 5.8 2.5 23 62 78 90 88 80 75 71 66 64BMVC560-6D 1.7 0.78 15 48 75 74 72 64 63 58 54 51BMVC630-4D 6.8 3.9 22 66 82 94 92 82 79 75 71 70BMVC630-6D 2.8 1.31 15 56 72 84 82 72 69 65 61 60BMVC710-6D 3.6 1.95 15 58 80 84 85 72 71 67 64 60BMVC710-8D 2.1 1.2 12 51 73 77 78 65 64 60 57 532E=2pole, 1phase. 2D=2 pole, 3phase, 4E=4 pole, 1Phase. 4D=4pole, 3phase. 6E=6pole, 1phase. 6D=6 pole, 3phase. 8D=8pole, 3phase.292 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


BMVC All Metal Vertical Discharge Centrifugal Bushfire CompliantDesign ConsiderationsOwing to the potential for debris buildup against ember protection meshbetween routine inspections andservicing, designers are advised tomake adequate allowance foraccumulating pressure losses in theirselections.Pressure (Pa)600500400300200100BMVC 4 - 4 Pole Pole400315450Suggested SpecificationBushfire Code Compliant(to maximum BAL-40) Roof MountedExhaust type fans shall be of theBMVC Series manufactured by <strong>Fans</strong><strong>Direct</strong> Pty LtdBackward curved impellers shall bedriven by external rotor motors withsealed for life bearings. Emberpenetration shall be prevented by theinstallation of stainless steel mesh witha maximum aperture of 2mm.The fans shall meet the designrequirements of AS 3959-2009 up toBAL-40.Pressure (Pa)00 200 400 600 800 1000 1200 1400 1600Air Flow (L/s)BMVC - 44 Pole1200100080060040063020056050000 500 1000 1500 2000 2500 3000 3500 4000Air Flow (L/s)BMVC - 6 Pole300Ancillaries250Pressure (Pa)2001501005035545050000 250 500 750 1000 1250 1500 1750Air Flow (L/s)600BMVC MVC - 6 Pole500Pressure (Pa)40030020010056063071000 500 1000 1500 2000 2500 3000 3500 4000Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 293


BVCQ Series Cowls Bushfire CompliantFANSCATALOGUEBVCQRoof cowls are designed to provide a weatherproof opening in ductedsystems to the outside of buildings. BVCQ models provide a range of sizesand capacities to suit almost any specification in either supply or exhaust airconfiguration. The cowls meet the requirements of AS 3959-2009 up to BAL-40.BVCQ-1 to BVCQ-5BVCQ-0ConstructionFabricated from heavy gauge galvanised steel. Ember penetration isprevented with stainless steel mesh with a maximum aperture of 2mm.Available in optional Colorbond colours.TestingAerodynamic performance has been determined by testing to DIN241631998.DataRefer to the latest product datasheet for individual model specification.Datasheets are available from our electronic selection software <strong>Fans</strong>Select<strong>download</strong>able at www.fansdirect.com.auBVCR-150A B(I/D) CBVCQ-0 & BVCR150 300 150 220Note: Add dimension 'C’ Curb Base to fan Dimension ’C’ foroverall assembly height.A B CBVCQ-0 Curb Base 170 240 55Design ConsiderationsOwing to the potential for debris buildup against ember protection meshbetween routine inspections andservicing, designers are advised tomake adequate allowance foraccumulating pressure losses in theirselections.Model A B C D KgBVCQ-1 380 330 25 195 6BVCQ-2 530 440 50 250 16BVCQ-3 715 615 80 340 30BVCQ-4 840 740 80 390 50BVCQ-5 960 810 80 420 60Suggested SpecificationBushfire Code Compliant(to maximum BAL-40) Roof MountedAir Relief Cowls shall be of the BVCQ/BVCR Series manufactured by <strong>Fans</strong><strong>Direct</strong> Pty Ltd.22010070BVCQ SeriesCowls shall be constructed fromgalvanised steel. Ember penetrationshall be prevented by the installationof stainless steel mesh with a maximumaperture of 2mm.Pressure (Pa)4020BVCQ-0BVCQ-1BVCQ-2BVCQ-3BVCQ-4BVCQ-5The cowls shall meet the designrequirements of AS 3959-2009 up toBAL-40.1050 100 200 750 1500 2500 5000 10000Air Flow (L/s)294 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 295


FANSCATALOGUESound AttenuationProducts296 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


LFS Series - Lightweight Flexible Silencers 298LDC Series - Cylindrical Silencers 300<strong>Fans</strong> <strong>Direct</strong> Attenuators 301© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 297


FANSCATALOGUELFS Series - Lightweight Flexible SilencersLFS SeriesLFS - Lightweight Flexible Silencers provide an economically priced solution toexcessive noise within ducted systems. Silencers can be fitted to the inlet /outlet of circular duct fans or to grilles and louvres as required. The silencersmay be bent to a maximum radius of 2 x overall (B) diameter with negligibleeffect on insertion loss values.In combination with MFP Series mixed flow fans, LFS silencers offer very lownoise ventilation performance in offices, residential dwellings andcommercial / retail spaces.All components of the kits have been designed to be as light as possible forfast installation and safe handling in tight spaces.ConstructionSilencers are manufactured from spun aluminium (spigots), metallisedpolyester with helical steel support (outer case) and high performanceacoustic lining / absorbing material. The sound absorbing material ischemically inert, non hygroscopic and vermin resistant.FeaturesUltra light weight.Class leading acoustic performance.Long spigots for easier connection to fans, grilles or louvres.Economically priced.Flexibility allows installation in tight locationsSuitable for rigid or flexible duct systemsSuggested SpecificationLightweight Silencers shall be of theLFS Series manufactured by <strong>Fans</strong><strong>Direct</strong> Pty Ltd.Silencers shall be constructed fromaluminium, metallised polyestersupported by helical steel wire.Internal acoustic lining and soundabsorbing material shall be chemicallyinert, non combustible, nonhygroscopic and vermin resistant.Acoustic performance shall bedetermined by testing in accordancewith BS4718:1971PartLFS SilencerPart A B C kgLFS150-S 150 265 600 1.7LFS200-S 200 320 600 1.9LFS200-L 200 320 1100 3.8LFS250-S 250 365 600 2LFS250-L 250 365 1100 4LFS315-S 315 415 1100 4.2LFS315-L 315 415 1600 6.3Sound Power Reduction dB(A)63 125 250 500 1K 2K 4K 8KLFS150-S 6 9 12 32 40 40 23 20LFS200-S 2 5 12 20 38 22 16 13LFS200-L 7 8 12 22 47 35 20 14LFS250-S 2 3 8 16 29 16 13 10LFS250-L 5 6 13 21 43 23 11 12LFS315-S 4 5 11 21 38 17 8 10LFS315-L 6 7 17 34 46 24 14 18298 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


160Pressure Drop LFS Series140120Pressure (Pa)100806040LFS200-LLFS250-LLFS315-LLFS315-S2000 500 1000 1500 2000 2500 3000Air Flow (L/s)60Pressure Drop LFS Series5040Pressure (Pa)3020LFS150-SLFS200-SLFS250-S1000 500 1000 1500 2000Air Flow (L/s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 299


FANSCATALOGUELDC Series - Cylindrical SilencersLDC SeriesLDC - silencers are high quality, rigid metal tubular design attenuators for usewith small diameter ventilation systems. Silencers can be fitted to the inlet /outlet of circular duct fans or to grilles and louvres as required.ConstructionSilencers are manufactured from galvanised steel with high performanceacoustic lining / absorbing material. The sound absorbing material ischemically inert, non hygroscopic and vermin resistant.FeaturesLong spigots for easier connection to fans, grilles or louvres.Suitable for rigid or flexible duct systemsPart A B C kgLDC150-600 150 250 600 5.3LDC200-600 200 300 600 6.9LDC200-900 200 300 900 9.7LDC250-900 250 355 900 8.5LDC315-600 315 415 600 11.8LDC315-900 315 415 900 16.3Sound Power Reduction dB(A)Part63 125 250 500 1K 2K 4K 8KLDC150-600 5 10 19 24 34 32 20LDC200-600 4 9 17 22 29 25 18LDC200-900 7 13 24 31 44 31 20LDC250-900 6 11 21 27 39 25 19LDC315-600 2 6 11 14 9 4 5LDC315-900 3 7 16 22 12 6 7Pressure Drop LDC SeriesSuggested SpecificationRigid Cylindrical Silencers shall be ofthe LDC Series supplied by <strong>Fans</strong> <strong>Direct</strong>Pty Ltd.Silencers shall be constructed fromaluminium and galvanised steel.Internal sound absorbing material shallbe chemically inert, non combustible,non hygroscopic and vermin resistant.Pressure (Pa)6050403020LDC150-600LDC200-900LDC200-600LDC250-900LDC315-900LDC315-600Acoustic performance shall bedetermined by testing in accordancewith BS4718:19711000 500 1000 1500 2000 2500 3000Air Flow (L/s)300 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


<strong>Fans</strong> <strong>Direct</strong> Attenuators<strong>Fans</strong> <strong>Direct</strong> Attenuators<strong>Fans</strong> <strong>Direct</strong> Attenuators offer high performance noise reduction in ductedventilation systems at competitive prices.ConstructionAttenuators and pods (where fitted) are rigidly constructed from galvanisedsteel, internally lined with sound absorbing material not less than 100mmthick, retained by galvanised steel perforated sheet.Attenuator end faces are drilled and tapped to match the flange details ofthe associated fan.Attenuator ‘sound’ absorbing material is chemically inert, non combustible,non hygroscopic and vermin resistant.TestingThe performance of <strong>Fans</strong> <strong>Direct</strong> Attenuators has been determined by testingin accordance with BS4718:1971Ranges Available· Circular Un-podded· Circular Podded· Rectangular Straight· Rectangular TaperedNote: All ranges are available as standard or with Melinex LiningSuggested SpecificationAttenuators shall be designed andsupplied by <strong>Fans</strong> <strong>Direct</strong> Pty Ltd.Attenuators and pods (where fitted)shall be rigidly constructed fromgalvanised steel, internally lined withsound absorbing material that ischemically inert, non combustible,non hygroscopic, vermin resistant andretained by galvanised steelperforated sheet.Attenuator end faces shall be drilledand tapped to match the flangedetails of the associated fan.Acoustic performance shall bedetermined by testing in accordancewith BS4718:1971Attenuation PerformanceThe following tables demonstrate the levels of sound reduction by octaveband to be offset against the sound spectrums of fans.Published RangeIn this catalogue we have published attenuation data relating to un-poddedand podded cylindrical silencers in single as well as double diameter lengthsfor the standard range of AX/AT/AC/AY/AZ/AB series axial fans. These dataprovide a quick guide for the set of attenuators useful in generalapplications.Selecting AttenuatorsTo access the full range of attenuators offered by <strong>Fans</strong> <strong>Direct</strong> and to selectthe right silencer for any given situation, please refer to our electronic fanand attenuator selection software, <strong>Fans</strong>Select, available for <strong>download</strong> atwww.fansdirect.com.auYour local <strong>Fans</strong> <strong>Direct</strong> sales office is equipped to answer specific queriesrelating to the full range of silencers and attenuators.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 301


FANSCATALOGUECSU - Standard (un-podded) Cylindrical AttenuatorsSize = 1 x ØCodeSound Power Reduction dB63 125 250 500 1K 2K 4K 8KCSU0350-1D 2 3 5 7 11 10 8 7CSU0400-1D 2 3 5 8 11 10 7 7CSU0450-1D 2 3 5 8 11 10 7 7CSU0500-1D 2 3 5 8 11 10 7 6CSU0560-1D 2 3 6 9 11 10 7 6CSU0630-1D 3 4 7 11 12 9 7 6CSU0710-1D 3 4 7 11 12 8 7 6CSU0800-1D 3 4 7 12 11 8 6 5CSU0900-1D 3 4 8 12 11 8 6 5CSU1000-1D 3 4 8 12 11 7 6 5CSU1120-1D 3 5 8 12 10 7 5 5CSU1250-1D 3 5 9 12 10 7 5 5CSU1400-1D 4 5 9 12 9 7 5 4CSU1500-1D 4 5 9 12 9 7 5 4CSU1600-1D 4 5 10 12 9 7 5 4CSU1800-1D 4 5 10 12 9 7 5 4CSU2000-1D 4 5 10 13 9 7 5 4Size = 2 x ØCodeSound Power Reduction dB63 125 250 500 1K 2K 4K 8KCSU0350-2D 4 4 8 12 18 16 13 10CSU0400-2D 4 5 8 12 18 16 13 10CSU0450-2D 4 5 8 13 18 16 12 10CSU0500-2D 4 5 8 14 19 15 12 10CSU0560-2D 4 5 9 15 19 15 12 10CSU0630-2D 6 6 10 18 20 14 11 8CSU0710-2D 6 6 10 18 20 13 11 8CSU0800-2D 6 6 11 19 19 13 11 8CSU0900-2D 6 7 12 19 19 12 10 7CSU1000-2D 6 8 13 18 17 12 9 7CSU1120-2D 6 8 13 18 17 12 9 7CSU1250-2D 6 8 13 18 16 11 8 7CSU1400-2D 8 8 14 18 15 10 8 6CSU1500-2D 8 8 14 18 15 10 8 6CSU1600-2D 8 8 14 19 15 10 8 6CSU1800-2D 8 8 14 19 15 10 8 6CSU2000-2D 8 8 14 19 14 10 8 6Dimensions 1 x ØCode A B C D E F KgCSU0350-1D 350 556 350 8 M8 358 14.2CSU0400-1D 400 606 400 12 M8 438 22.5CSU0450-1D 450 656 450 12 M8 488 24.5CSU0500-1D 500 706 500 16 M8 541 26.8CSU0560-1D 560 766 560 16 M8 605 30.5CSU0630-1D 630 836 630 16 M8 674 34.5CSU0710-1D 710 916 710 16 M10 765 49.5CSU0800-1D 800 1006 800 16 M10 865 55.3CSU0900-1D 900 1106 900 16 M10 966 75CSU1000-1D 1000 1206 1000 16 M12 1070 91CSU1120-1D 1120 1330 1120 16 M12 1185 103CSU1250-1D 1250 1456 1250 16 M12 1320 111CSU1400-1D 1400 1606 1400 24 M12 1480 123CSU1500-1D 1500 1706 1500 24 M12 1560 155CSU1600-1D 1600 1806 1600 24 M12 1685 197CSU1800-1D 1800 2006 1800 24 M12 1890 220CSU2000-1D 2000 2206 2000 24 M12 2080 245Dimensions 2 x ØCode A B C D E F KgCSU0350-2D 700 556 350 8 M8 358 28.4CSU0400-2D 800 606 400 12 M8 438 45CSU0450-2D 900 656 450 12 M8 488 49CSU0500-2D 1000 706 500 16 M8 541 53.6CSU0560-2D 1120 766 560 16 M8 605 61CSU0630-2D 1200 836 630 16 M8 674 69CSU0710-2D 1420 916 710 16 M10 765 99CSU0800-2D 1600 1006 800 16 M10 865 110.6CSU0900-2D 1800 1106 900 16 M10 966 150CSU1000-2D 2000 1206 1000 16 M12 1070 182CSU1120-2D 2240 1330 1120 16 M12 1185 206CSU1250-2D 2400 1456 1250 16 M12 1320 222CSU1400-2D 1800 1606 1400 24 M12 1480 246CSU1500-2D 3000 1706 1500 24 M12 1560 310CSU1600-2D 3200 1806 1600 24 M12 1685 394CSU1800-2D 3600 2006 1800 24 M12 1890 440CSU2000-2D 4000 2206 2000 24 M12 2080 490Note: Pressure drop for un-podded attenuators is negligible.302 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


CSP - Podded Cylindrical AttenuatorsSize = 1 x ØCodeSound Power Reduction dB63 125 250 500 1K 2K 4K 8KCSP0350-1D 4 5 8 14 18 18 14 11CSP0400-1D 4 5 8 14 19 18 14 11CSP0450-1D 4 5 8 14 19 18 14 11CSP0500-1D 4 5 9 14 19 17 14 11CSP0560-1D 4 6 9 15 20 17 14 11CSP0630-1D 4 6 9 17 22 18 15 10CSP0710-1D 4 6 10 17 22 18 15 10CSP0800-1D 4 6 10 18 21 18 15 10CSP0900-1D 4 7 10 18 20 18 15 11CSP1000-1D 4 7 12 20 18 15 13 11CSP1120-1D 4 7 12 20 18 14 13 11CSP1250-1D 4 7 12 20 18 14 13 11CSP1400-1D 6 9 13 21 18 13 11 10CSP1500-1D 6 9 13 22 17 13 10 9CSP1600-1D 6 9 13 22 17 13 10 9CSP1800-1D 6 10 14 22 17 13 10 9CSP2000-1D 6 10 14 23 17 12 10 9Size = 2 x ØCodeSound Power Reduction dB63 125 250 500 1K 2K 4K 8KCSP0350-2D 7 8 13 24 28 29 23 18CSP0400-2D 7 9 13 24 29 28 23 19CSP0450-2D 7 9 14 24 29 28 24 19CSP0500-2D 7 9 14 25 30 27 24 20CSP0560-2D 7 10 14 25 31 27 24 20CSP0630-2D 7 10 15 28 34 29 26 19CSP0710-2D 7 10 15 28 33 29 26 19CSP0800-2D 7 11 16 29 32 29 25 18CSP0900-2D 7 11 16 30 32 29 25 18CSP1000-2D 7 12 18 31 29 25 21 17CSP1120-2D 7 13 19 31 29 24 20 17CSP1250-2D 7 13 19 31 29 24 20 17CSP1400-2D 10 15 21 28 25 21 17 15CSP1500-2D 10 15 21 29 24 21 16 15CSP1600-2D 10 15 21 29 24 20 16 15CSP1800-2D 10 16 22 29 24 20 16 15CSP2000-2D 10 16 22 29 24 19 16 14Dimensions 1 x ØDimensions 2 x ØCode A B C D E F KgZCode A B C D E F KgZCSP0350-1D 350 556 350 8 M8 358 15.319.7CSP0350-2D 700 556 350 8 M8 358 30.619.7CSP0400-1D 400 606 400 12 M8 438 25.38.2CSP0400-2D 800 606 400 12 M8 438 50.68.2CSP0450-1D 450 656 450 12 M8 488 336.2CSP0450-2D 900 656 450 12 M8 488 666.2CSP0500-1D 500 706 500 16 M8 541 36.54CSP0500-2D 1000 706 500 16 M8 541 734CSP0560-1D 560 766 560 16 M8 605 41.52.7CSP0560-2D 1120 766 560 16 M8 605 832.7CSP0630-1D 630 836 630 16 M8 674 47.51.5CSP0630-2D 1200 836 630 16 M8 674 951.5CSP0710-1D 710 916 710 16 M10 765 710.9CSP0710-2D 1420 916 710 16 M10 765 1420.9CSP0800-1D 800 1006 800 16 M10 865 790.55CSP0800-2D 1600 1006 800 16 M10 865 1580.55CSP0900-1D 900 1106 900 16 M10 966 1080.31CSP0900-2D 1800 1106 900 16 M10 966 2160.31CSP1000-1D 1000 1206 1000 16 M12 1070 1290.22CSP1000-2D 2000 1206 1000 16 M12 1070 2580.22CSP1120-1D 1120 1330 1120 16 M12 1185 1450.13CSP1120-2D 2240 1330 1120 16 M12 1185 2900.13CSP1250-1D 1250 1456 1250 16 M12 1320 1600.081CSP1250-2D 2400 1456 1250 16 M12 1320 3200.081CSP1400-1D 1400 1606 1400 24 M12 1480 1800.052CSP1400-2D 1800 1606 1400 24 M12 1480 3600.052CSP1500-1D 1500 1706 1500 24 M12 1560 2500.04CSP1500-2D 3000 1706 1500 24 M12 1560 5000.04CSP1600-1D 1600 1806 1600 24 M12 1685 2900.031CSP1600-2D 3200 1806 1600 24 M12 1685 5800.031CSP1800-1D 1800 2006 1800 24 M12 1890 3250.017CSP1800-2D 3600 2006 1800 24 M12 1890 6500.017CSP2000-1D 2000 2206 2000 24 M12 2080 3620.013CSP2000-2D 4000 2206 2000 24 M12 2080 7240.013Note: Air pressure drop of attenuator (Pa) = Z x Q 2 where Z = factor listed in tables above andQ = volume flow (m 3 /s)© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 303


FANSCATALOGUEAJR/AJ8 Car Park Ventilation Jet <strong>Fans</strong>productAJR/AJ8 Car Park Ventilation Jet <strong>Fans</strong>dimensions mm315 - 400poles & duty2 - 4 / up to 3,100 L/sapplicationA specialised package of fans and controllers for car park ventilation.<strong>Fans</strong> <strong>Direct</strong> is able to offer a complete solution in car park ventilation at acompetitive price in partnership with Systemair AB, one of Europe’s largestand most experienced fan specialists.Car Park Ventilation PrinciplesJet fan systems are active systems offering a cost effective solution toventilate and extract smoke from enclosed or underground car parks. Thisductless ventilation system provides either normal ventilation or smokeextract in case of emergencies, or a combination of both.An efficient system requires good planning, starting with the physicaldimensions of the cark park, considering the pattern of utilisation as well aspeak loads. Ventilation rates are mostly based on an air exchange rate(pollution), or on a rate multiplied with the number of parking spaces. This isdefined in the appropriate local building regulations, defining normalventilation and emergency ventilation.A jet fan system offers the “ventilation on demand” principle for car parks,depending on measurements by CO detectors. Jet fans can be individuallycontrolled, or grouped together in fire zones. In fire mode, after a pre-setstandstill escape period, the jet fans will run at full speed to quickly andeffectively clear smoke.BenefitsThe space saving design, compared to a standard duct based ventilationsystems, offers a variety of benefits:· It is possible to ventilate or extract smoke in particular sections of thecar park. CO (carbon monoxide) detectors and smoke sensors ensurethat only fans in polluted areas are activated and the fans areswitching into smoke extract mode immediately if a fire starts.· No expensive, bulky and complex duct systems, making it an idealsolution also for renovations. Car park design is more attractive.· Improved air quality in underground car parks compared toconventional ducted systems (mixture of all layers of air within the carpark).· Optimum safety is provided in case of a fire in the car park. Rapidsmoke extraction, smoke cooling, limited smoke spread, i.e. bettersmoke control.· Jet fan systems for smoke extract prevent costly consequentialdamages in case of a fire: the ceilings are subjected to less heat, andsmoke is quickly removed from the building.· More flexible in positioning when the parking area in the car park isredesigned.· Energy saving in exhaust air fans due to reduced system resistance (noduct systems).· Reduced installation and running costs.304 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Control systemA control system is required, which is tailored to handle the requirements ofthe specific project for ventilating and smoke extraction. As a rule of thumb,car park ventilation is based on 6ACH for normal ventilation and 10ACH forsmoke extract.A good control system saves energy by reducing the ventilation rate with thehelp of CO sensors, depending on the car park usage, increasing ventilationrate only in peak hours and operating the jet fans only selectively, accordingto demand.When used for smoke extract, the system has to work on a fire detectionsystem (heat or smoke detection). In car parks with different levels, thesystem has to run the jet fans full speed on the fire level, and simultaneouslyswitch off the fans in all other levels. The main exhaust air fans are switchedto full speed. The control equipment regulates the main supply and/orexhaust fans together with the jet fans, both depending on thesignals coming from the sensors.Section velocity vectorsInfluence of drop beamsMean age of airCFD simulationA CFD simulation is needed to confirm that there is enough air movement inall areas of the car park to secure the required number of air exchanges, toconfirm the proposed number of jet fans and to determine the locationswhere the jet fans need to be installed.In order to perform a CFD analysis, it is essential to have a 3-Dmodel of the building site, giving all openings, slab height, surface of theceiling (flat or with drop beams, dimensioning of the drop beams, etc.)and all other details required to carry out a simulation.A CFD analysis is used to simulate the airflows, to ensure that the distributionof the air is sufficient to effectively ventilate the cark park under normalconditions as well as in emergency situations. <strong>Fans</strong> <strong>Direct</strong> and Systemair offersthis service for a nominal fee providing a complete package from onesource.Fan ConstructionThe fans are equipped with adjustable aluminium impellers and fullycompliant motors, available for ambient temperatures for CO exhaust(between 40°C and 60°C) or for high temperature smoke exhaust (300°C/2h)applications.· Three sizes (315, 355 and 400 mm impeller diameter), circular oroctagonal design.· Also available with fully reversible blade settings (on request).· Fan casings and outside sheet for fan housing and silencersmanufactured from galvanized sheet steel.· Fan module sound insulated for low noise level.· Pre-wired terminal box manufactured from thermoplastic or aluminiumfor the high temperature version.· Silencers with integrated inlet cones and guide vane to straighten theairflow. Sound attenuating material is non-flammable.· Protection guards on inlet and outlet, manufactured from powdercoated steel.· Pre-assembled mounting brackets manufactured from galvanizedsteel, for safe and easy ceiling suspension.· Fan module removable from installed unit, for quick and easymaintenance.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 305


FANSCATALOGUEAJR/AJ8 Car Park Ventilation Jet <strong>Fans</strong>Size ØDa H E C F315 422 431 426.2 259 457.5355 462 471 444.7 280 476400 502 513 510 303 540Size k L Lt ts tc315 400 2200 2213 1 2355 400 2200 2213 1 2400 400 2200 2213 1 2tm333Size ØDa H E C F315 365 550 355 610 650355 395 550 355 610 650400 445 600 380 660 700Size k L Lt ts tc315 476 2200 2213 1 2355 476 2200 2213 1 2400 476 2200 2213 1 2tm2.52.52.5Fan Model (Round) Fan Model (Octagonal) Thrust N L/s Amps RPS dB(A)@ 3m kg TempAJR 315-2 AJ8 315-2 30 1500 2.3 47 52.5 70 55°CAJR 315-2/4 AJ8 315-2/4 30 1500/750 2.5/0.57 47/23 52.5/37.5 70 55°CAJR 355-2 AJ8 355-2 53 2100 4.3 47 57.5 103 55°CAJR 355-2/4 AJ8 355-2/4 53 2100/1050 4.9/1.4 48/24 57.5/42.5 107 55°CAJR 400-2 AJ8 400-2 85 3100 5.7 47 62.5 142 55°CAJR 400-2/4 AJ8 400-2/4 85 3100/1550 6.9/2.45 48/25 62.5/47.5 145 55°CAJR 315-2 (F300) AJ8 315-2 (F300) 30 1500 2.3 47 52.5 70 300°C/2hAJR 315-2/4 (F300) AJ8 315-2/4 (F300) 30 1500/750 2.5/0.57 47/23 52.5/37.5 70 300°C/2hAJR 355-2 (F300) AJ8 355-2 (F300) 53 2100 4.3 47 57.5 103 300°C/2hAJR 355-2/4 (F300) AJ8 355-2/4 (F300) 53 2100/1050 4.9/1.4 48/24 57.5/42.5 107 300°C/2hAJR 400-2 (F300) AJ8 400-2 (F300) 85 3100 5.7 47 62.5 142 300°C/2hAJR 400-2/4 (F300) AJ8 400-2/4 (F300) 85 3100/1550 6.9/2.45 48/25 62.5/47.5 145 300°C/2h306 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 307


Guide for selecting kitchen fansFANSCATALOGUEOverviewThis guide is based on rule of thumb concepts as an aid to fan selection forkitchen hood extraction applications. This should not replace professionaladvice in the design and specification of complex systems. AustralianStandards stipulate a minimum requirement, It is recommended thatdesigners check that this meets their clients requirements.Sidewall Canopy<strong>Fans</strong> <strong>Direct</strong> staff make calculations based on the AS/NZS 1668:2002 Standard,and can assist with special applications that fall outside this Standard. <strong>Fans</strong><strong>Direct</strong> also has an extensive range of fans for the supply of make-up air andmanual or automatic fan controllers. We can also assist in the provision oftemperature and pressure controlled fans for use in advanced systems.Calculating air requirementsCalculate the required airflow for the Hood using the following formulas.These are derived from Standard AS/NZS1668:2 2002. This is a guide only. Firstdetermine the Hood Process Type. Note, if a hood serves equipment of morethan one process type then the highest rated process type shall be appliedto the entire hood.Process types: Abbreviated from AS1668: 2 2002Type Grease Typical Equipment1 None Non Grease producing equipment.Island Canopy2 Low Griddles, Ranges, Conventional Fryers, Steam Kettles, Gas Ovens3 High Electric Deep Fat Fryers, Grooved Griddles, Hot Tops and Hot Top Ranges.4 High Countertop BBQ, Gas Deep Fat Fryers5 High Woks, Salamanders, any open flame solid fuel cooking.For Corner, Sidewall and Island CanopiesFor Low Sidewall (Back-shelf) CanopiesTypeFormulaTypeFormula1 & 2 Q = (190 x P x H) / 10003 Q = (250 x P x H) / 10004 & 5 Q = (375 x P x H) / 10001 & 2 Q = (400 x L) / 10003 Q = (600 x L) / 10004 & 5 Q = (800 x L) / 1000Use the appropriate formula above, with the process type selected from top table.QQ = Required Air qty in m 3 s-1P = Inside Perimeter of hood in Metres (exposed sides)H = Height of Hood above cooking applianceL = Length of HoodPLH308 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Canopy FiltersGuide to calculating system resistance for Exhaust Canopy SystemsThe table below lists approximate static pressure drops for different fittings ata design velocity of 8ms to 12ms. The higher the duct velocity, the moresuspended particles such as grease are carried through and ejected from theduct. Lower velocities will increase the cleaning frequency required. This is aguide designed to enable fans to be selected, which will perform effectively.The data is a combination of ASHRAE and field experience results.Historically, many fans have been requested which are not appropriatelysized to meet the airflow requirements of the AS1668 Standard. By meetingthe Standard you help to ensure that your customer is able to fully utilise yourcanopy product, this reduces the incidence of call backs to address airflowrelated issues.Schedule of fittings and approximate Static Pressure loss.Standard DuctsFitting 8ms Static 10ms Static 12ms StaticInternal Hood Losses (if Hood is >3:1 Length/width Ratio) 19 30 43Duct Connection to Hood 19 30 4390 Deg Bend (Mitre) 46 72 10390 Deg Bend (Radius) 40 63 90Expansions and Contractions 6 10 15‘Y’ Piece 44 70 100Insulated DuctsOutlet – ‘Chinamans Hat’ 57 90 130Outlet – Horizontal Cut-off no guard 32 51 73Outlet – Horizontal Cut-off with finger guard 50 78 110Steel Ducting (per metre) 2 2.5 3Spiral Ducting (per metre) 3 4 5Standard Overall Pressure Drops.90° Bend DuctsFittingLow-Loss Filters (Set)Standard Filters (Set)Static35Pa50PaSpiral DuctsCalculating system velocities and Duct Sizing for Exhaust Canopy SystemsCanopy systems should run at a minimum of 8ms-1. While from a particleejection point of view it is often better to run at higher velocities, the extraenergy and higher fan power requirements often make this undesirable. Itshould also be noted that noise generated by duct turbulence will increasewith the velocity. Duct velocity is a function of the volume flow through theduct, and the area of the duct.System Velocities and Duct SizingVolume (m 3 s-1) = Velocity (ms-1) x Area (m 2 ) therefore Area= Volume / Velocitye.g. If you require 2000 l/s for the Hood and a Velocity of 8 metres per second, thenArea = 2m 3 s-1/8ms-1 = 0.25m 2 .To convert this area into an equivalent round duct diameter, divide by Pi, find theSquare root of the answer and multiply by 2.To get an equivalent Square size, take the square root of the area. e.g. Round Ductdiameter = 0.25m 2 / 3.14 = 0.0796 SQRT = 0.282 x 2 = .564m 2 e.g. Square Duct dimension= SQRT 0.25m 2 = 0.5m i.e. 500mm x 500mm© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 309


Guide for selecting kitchen fansFANSCATALOGUESelecting <strong>Fans</strong>Whatever the application, airflow and pressure required, <strong>Fans</strong> <strong>Direct</strong> offers afull range of fans, controllers and accessories to suit and complete yourkitchen exhaust system.MVCFrom all metal construction roof mounted centrifugal and axial fans to Inlineadjustable pitch axial and backward curved centrifugals, our fully tested andengineered fans offer optimal performance with quiet operation and ease ofinstallation and maintenance.Roof Mounted Kitchen Canopy <strong>Fans</strong>Range Code Type Flows to: m 3 /s Pressures: Sound:MVC Centrifugal 4 High/Med LowVD Axial 16 Med/Low MedKMV Centrifugal 4 High/Med LowInline <strong>Fans</strong> for Canopies and supply air systems.AXRange Code Type Flows to: m 3 /s Pressures: Sound:FEF Axial 5.5 Low LowAX Axial 6.0 Low/Med/High MedICQ Centrifugal 3.5 High/Med LowSCD Centrifugal 3.5 High/Med LowRoof Mounted Supply Air <strong>Fans</strong>Range Code Type Flows to: m 3 /s Pressures: Sound:CSCS Centrifugal 2.3 High/Med LowSelecting Speed ControlsThere are many speed control options available with features and benefits tosuit particular applications. <strong>Fans</strong> <strong>Direct</strong> is able to provide job specific advicetaking into account site and client requirements. The following tables providea general guide to selecting speed controls.VDSingle Phase-Electronic Speed ControllersFor Against CommentsLow CostShould not control fans below 60% offull speed. Energy inefficient. Cancreate motor ‘hum’ at low speedsGenerally good for use with smallfans below 0.5kW. Not suitablefor foot or flange mount motors.Single Phase-Transformer Speed ControllersFor Against CommentsVery quiet fan operation, moreefficient than electronic controllers.CostThe best speed control to usewith single phase fans. Can beused with external rotor motorsup to 2kW.KMVThree Phase-Transformer Speed ControllersFor Against CommentsVery quiet fan operation. Cost and size Easy, five step speed controlfor external rotor motorsThree and Single Phase-Variable Speed DriveICQFor Against CommentsVery quiet fan operation , widespeed range, control inputs andsignals.ComplexityThe best way to control threephase fans.Note: It is not recommended to speed control conventional single-phase motors with triac type controllers due toheat build up and noise.310 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 311


FANSCATALOGUEAncillaries, Speed Controllers& Switches312 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Flanges 314Inlet Cones - Guards316Foot Brackets / Mounting Brackets 317Vibration Isolators 321Non Return Dampers 323Grilles and Diffusers 324Aquaseals, Extension Tubes, Flexible Duct 327Speed Controllers and Switches 328© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 313


FANSCATALOGUEFlangesFLA-AX Flanges for all AX Series <strong>Fans</strong>Manufactured from heavy gauge galvanised steel, supplied in pairs. Note thathole diameters are nominal, holes for most sizes are slot type for easierinstallationF=No. of GØ holesequi-spaced on Hp.c.d.Fan Size A F G H315 30* 8 9.5 356400 30* 12 10 438450 30* 12 10 488500 30* 12 10 541560 30* 16 10 605630 30* 16 10 674710 40 16 12 765800 50 16 12 865900 50 16 12 966NOTE: * Pressed type flange.Fan Size A F G H1000 65 16 14 10701100 65 16 14 11851200 65 16 14 13201400 65 24 14 14801500 65 24 14 15601600 65 24 14 16851800 65 24 14 18902000 65 24 14 2080FLA-FEF Flanges for all FEF Series <strong>Fans</strong>Manufactured from spun galvanised steel, supplied in pairs. Note that hole diametersare nominal, holes for most sizes are slot type for easier installationFan Size A B C D E F G Kg200 255 202 231 20 9 7 4 0.2250 306 256 282 20 9 7 4 0.25300 360 310 336 20 9 7 4 0.3350 420 356 395 30 9 9.5 8 0.35400 465 400 438 30 9 9.5 12 0.4450 515 451 488 30 9 9.5 12 0.5500 565 503 541 30 9 9.5 12 0.7560 630 560 605 30 9 11.5 16 0.75630 710 634 674 30 9 11.5 16 0.8314 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


FlangesFLA-ICQ / FLA-SCDQ Flanges for all ICQ and SCDQ Series <strong>Fans</strong>Light weight square flange manufactured from galvanised sheet steel withcorner fixing points, supplied in pairs.Fan Size A B C D kg315 480 410 445 35 1.75355 520 450 485 35 2400 570 500 535 35 2.1450 620 550 585 35 2.3Fan Size A B C D kg500 720 650 685 35 2.75560 770 700 735 35 3630 870 800 835 35 3.5FLA-SCD/FLA-TCD Flanges for all rectangular duct fansLight weight square flange manufactured from galvanised sheet steel withcorner fixing points, supplied in pairs.SCDFan Size A B C D E F G Kg280 570 500 535 35 420 350 385 1.85315 570 500 535 35 420 350 385 1.85355 670 600 635 35 470 400 435 1.85400 720 650 685 35 520 450 485 2450 770 700 735 35 570 500 535 2.3500 870 800 835 35 620 550 585 2.75560 970 900 935 35 670 600 635 3.05630 1070 1000 1035 35 920 850 885 3.7710 1170 1100 1135 35 970 900 935 3.95TCDFan Size A B C D E F G Kg315 570 500 535 35 555 485 520 2.1355 670 600 635 35 662 592 627 2.1400 720 650 685 35 760 690 725 2.45450 770 700 735 35 820 750 785 2.75500 870 800 835 35 910 840 875 3.3560 970 900 935 35 970 900 935 3.5© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 315


FANSCATALOGUEInlet ConesCIC Inlet Cones for all AX/AT/AC/AY/AZ/AB Series <strong>Fans</strong>Manufactured from heavy gauge galvanised steel with a single boltedflange. Standard accessory losses (k) 0.38Pressure drop (Pa) = 0.6 x k x Velocity 2 (m/s)Note: Cone flange holes match fan cases and flanges.Fan Size E F kg315 93 405 2400 103 490 3450 110 545 4500 118 605 5560 93 680 6630 104 765 9710 117 855 11800 130 950 13900 150 1060 20Fan Size E F kg1000 165 1170 231100 188 1375 321200 210 1545 401400 230 1750 451500 255 760 481600 265 1900 -1800 300 2100 -2000 340 2340 -GuardsCGD GuardsManufactured from heavy gauge galvanised steel and zinc plated steelmesh. Standard accessory losses (k) 0.75Pressure drop (Pa) = 0.6 x k x Velocity 2 (m/s)Note: CGD Guards include a flange ring for attachment to fans. Guardswithout flange rings are available as a more economical option and are fitteddirectly to the fan flange.Fan SizekgFan Sizekg315 0.5400 1.5450 1.7500 2.3560 2.8630 3.2710 3.7800 4900 71000 71100 81200 81400 101500 131600 151800 182000 20316 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Foot Brackets / Mounting BracketsFoot Mounting Brackets for all duct mounted axial <strong>Fans</strong>Manufactured from heavy gauge galvanised steel, supplied in pairs.Note: Foot Bracket holes match fan case and flanges in each diameter.Fan SizeHFan SizeH315 220350** 290400* 290450* 330500* 380560* 420630* 500710 540800 720900 8101000 9101100 9601200 10901400 12401500 13401600 14401800 16402000 1840**FEF350 only.* Suits AX and FEF models.Foot-FEF-Small, Mounting Brackets for all FEF200, 250,300 <strong>Fans</strong>Manufactured from galvanised sheet, supplied in pairs.For Fan Size A B C D KG200, 250, 200 50 64 47 1.6 0.1CB150 Mounting Bracket for all K and KS ModelsDesigned to mount small diameter fans under floors or in ceiling spaces.Manufactured from corrosion protected steel with rubber bush for vibrationisolation. Includes TCB200-350 bracket as part of the assembly. Refer toTCB200-350 specifications for details.Part A B C D KGCB150 150 50 25 57 0.3© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 317


Foot Brackets / Mounting BracketsFANSCATALOGUETCB200-350 Mounting Brackets for all K and KS Series <strong>Fans</strong>Designed to mount small diameter fans under floors or in ceiling spaces.Manufactured from galvanised sheet steel.Part A B C D KGTCB200-350 130 107 30 40 0.15ICF Mounting Brackets for all ICQ, SMD, SCD and TCD ModelsUsed to mount square or rectangular inline fans in ceiling spaces or underfloors. Manufactured from galvanised sheet, supplied in pairs.For Fan Size A B KG310 650 600 1.65355 750 700 1.9400 800 750 2.1450 850 800 2.2For Fan Size A B KG500 950 900 2.4560 1050 1000 2.65630 1150 1100 2.9710 1250 1200 3.1FK Clamp / Mounting Bracket for all circular models 125mm-315mmUsed to mount circular fans or connect to rigid / flexible ducting systems.Manufactured from galvanised sheet steel with neopreneFor Fan Size A KG125 125 0.3150 150 0.35200 200 0.4250 250 0.5315 315 0.7318 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Vibration IsolatorsRHE Rubber Isolation Hanger ElementA low cost, low deflection hanger element for effective isolation of noise andvibration from mechanical equipment. Typically used for trapeze supportedpiping, packaged air conditioners, fan coil units and fans. Particularly usefulwhere space is limited.FeaturesColour coded for easy identificationCorrosion proof - all metal elements embedded in the elastomerFurther Technical InformationDetailed technical information is available from the manufacturer, GPEmbelton and Co Pty Ltd. A PDF catalogue is available for <strong>download</strong> atwww.embelton.com.auRHE1RHE2TypeColourCodeMax LoadKgBlue 17White 25Red 40Green 55White 70Red 100Green 160Grey 250StaticDefl. MMH L W D A G E5 27 45 25 22 36 10 26 32 60 30 25 45 163RH Rubber Isolation HangerA low cost, low deflection hanger for effective isolation of noise and vibrationfrom mechanical equipment. Typically used for piping, packaged airconditioners, fan coil units and fans.FeaturesThe active element is colour coded for easy identificationHeavy duty steel cageFully weather proofResistant to failure caused by fire or mechanical damageFurther Technical InformationDetailed technical information is available from the manufacturer, GPEmbelton and Co Pty Ltd. A PDF catalogue is available for <strong>download</strong> atwww.embelton.com.auRH1RH2TypeColourCodeMax LoadKgBlue 17White 25Red 40Green 55White 70Red 100Green 160Grey 250StaticDefl. MMH L W D G5 31 75 60 50 106 41 130 75 65 16© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 319


FANSCATALOGUEVibration IsolatorsNR Rubber MountingA low cost rubber/steel mounting for effective isolation of noise and vibrationfrom mechanical equipment with speeds of 1,000 rpm and higher.FeaturesColour coded for easy identificationCorrosion proof - metal all elements embedded in the elastomerNon-skid ribbed baseFurther Technical InformationDetailed technical information is available from the manufacturer, GPEmbelton and Co Pty Ltd. A PDF catalogue is available for <strong>download</strong> atwww.embelton.com.auTypeNR1NR2NR3ColourCodeMax LoadKgBlue 17White 25Red 40Green 55Grey 80White 70Red 100Green 160Grey 250White 145Red 200Green 300StaticDefl. MMH L W D A G K E5 28 80 45 60 36 M10 8.5 56 32 98 60 76 45 M10 8.5 66 44 140 85 104 68 M12 14 7NR4Grey 500Blue 380White 580Red 850Green 13006 46 166 110 128 100 M16 14 9SHS Isolation HangerA steel spring hanging mount for effective isolation of noise and vibrationfrom mechanical equipment.FeaturesColour coded for easy identificationFully weather proofedRugged, heavy gauge steel cageNon-skid ribbed baseFurther Technical InformationDetailed technical information is available from the manufacturer, GPEmbelton and Co Pty Ltd. A PDF catalogue is available for <strong>download</strong> atwww.embelton.com.auTypeMax Load KgStatic Defl.MMSpringColoursSHS-9 10 33 YellowH L W D GSHS-10 15 33 BrownSHS-11 30 33 BlueSHS-12 50 28 BlackSHS-13 75 25 Red86 130 75 65 12SHS-14 125 25 GreenSHS-16 175 20 GreySHS-17 200 15 Orange320 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Vibration IsolatorsXS-XL Open Spring MountSteel spring mount for effective isolation of noise and vibration frommechanical equipment. Easily installed and the spring can be easilyinterchanged to give a wide range of load/deflection characteristics.FeaturesColour coded for easy identificationFully weather proofedRubber isolated bolt hole in baseBuilt in levelling bolt with locking cap screw (XL only)Separate top and bottom locating cupsHeavy duty stable steel springFurther Technical InformationDetailed technical information is available from the manufacturer, GPEmbelton and Co Pty Ltd. A PDF catalogue is available for <strong>download</strong> atwww.embelton.com.auTypeMax Load KgStatic Defl.MMSpringColoursXS-9 10 33 YellowH A G J K EXS-10 15 33 BrownXS-11 30 33 BlueXS-12 50 28 BlackXS-13 75 25 Red84 60 12 - 16 12XS-14 125 25 GreenXS-16 175 20 GreyXS-17 200 15 OrangeTypeMax LoadKgStatic Defl.MMSpringColoursXL-89 10 40 WhiteH A G J K EXL-90 20 38 VioletXL-91 35 35 Violet/BlackXL-92 50 33 YellowXL-93 100 33 BrownXL-94 150 30 BlueXL-95 200 30 Black127 80 M16 M10 2013XL-96 250 28 Red 132 80 M16 M10 20 13© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 321


FANSCATALOGUEVibration IsolatorsCLM Seismic MountingAn integrated, stand alone six direction restrained spring mounting with cuplocated springs and internal level adjustment. CLM Mounts are rated to thestatic force restraint requirements of:AS1170.4 for application up to maximum equipment loads in all Australianseismic zones.NZS4219 for application with reduced equipment load range in New Zealand.ApplicationWhere equipment requires the use of a spring type mounting for high degreeisolation under normal operating conditions but with the facility to restrainequipment from excessive motion in any direction due to displacementinputs imparted by the foundation through earthquake activity.FeaturesHeavy duty stable steel springAcoustically isolating location cupSingle adjustable central vertical restraint and levelling boltFully weather proofedConstructionHot dipped galvanised steel housing, oil resistant high frequency spring baselocation cup. All other components including spring are zinc plated.Mounting SelectionWhen selecting mountings for seismic applications, it is recommended thatthe calculated mass of the equipment be increased by 20% to ensure staticdeflections are conservative. For equipment using more than four mountingpoints, distribution of the mounting should be such that each has equalloading. If this cannot be done, mounting selections must be made on thebasis of matching static deflections as closely as possible.Further Technical InformationThis overview provides minimum detail and should not be used for final designpurposes. Reference should be made to the relevant earthquake standardsfor the country concerned. Detailed technical information specific to thecorrect selection of seismic mounts is available from the manufacturer, GPEmbelton and Co Pty Ltd. www.embelton.com.auTypeMax Load KgStatic Defl.MMSpringColoursCLM-89 10 40 WhiteCLM-90 20 38 VioletCLM-91 35 35 Violet/BlackCLM-92 50 33 YellowCLM-93 100 33 BrownCLM-94 150 30 BlueCLM-95 200 30 BlackCLM-96 250 28 RedCLM-97 300 28 GreenCLM-98 400 25 GreyHoriz. RestraintCapacity3.5kNVert. RestraintCapacity7kN322 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Non Return DampersNRD-Non Return Damper for rectangular or square fan and duct applicationsNRD’s are shutter type dampers designed to provide an effective back draftseal in ducted systems. These dampers can be installed either vertically orhorizontally.ConstructionFlaps are fabricated from extruded PVC. Frames are fabricated fromanodised aluminium with polymer corner joints.Damper SelectionStandard sizes are listed in the table below to allow selections for insertion intoduct systems. To select dampers for specific fans whether duct or roofmounted, refer to <strong>Fans</strong>Select electronic selection software available for<strong>download</strong> at www.fansdirect.com.au.Square Standard ModelsPart A B kgNRD-001 344 - 0.8NRD-002 394 - 1NRD-003 457 - 1.2NRD-004 499 - 1.4NRD-005 544 - 1.7NRD-006 605 - 2NRD-007 696 - 2.6NRD-008 760 - 2.7NRD-009 840 - 3.1NRD-010 1040 - 5.2Note: Alternative, non standardsizes are readily available. Contactyour nearest <strong>Fans</strong> <strong>Direct</strong> sales officefor specific availability.Rectangular Standard ModelsPart A B kgNRD-011 223 497 0.8NRD-012 280 597 1NRD-013 302 647 1.1NRD-014 325 697 1.2NRD-015 355 797 1.3NRD-016 408 897 1.5NRD-020 347 497 1.2NRD-021 397 597 1.5NRD-022 447 647 1.8NRD-023 497 697 1.9NRD-024 547 797 2.6NRD-025 597 897 2.7NRD-026 847 997 3.1NRD-027 897 1097 5.2RSK-Non Return Damper for circular fan and duct applicationsRSK’s are butterfly type dampers designed to provide an effective back draftseal in ducted systems. These dampers can be installed either vertically orhorizontally.ConstructionCases are fabricated from roll formed galvanised sheet. Butterfly elementsare made from lightweight aluminium sheet held in the closed position withlow resistance steel springs.Part A D B CRSK125 125 100 33 44RSK150 150 100 34 43RSK200 150 140 55 62RSK250 250 140 54 62RSK300-S 300 - - -RSK315* 315 140 60 55RSK350-S 350 - - -* May be used with RED315-300 Reducer for use with300mm fans and ducts.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 323


FANSCATALOGUEGrilles and DiffusersRDJ Round Diffuser Jet OutletDesigned to jet the airflow right down to the floor which aids in mixing andcirculating the air. The airflow volume is easily adjustable by pushing/ turningthe central knob which activates opposed blade dampers making finetuning quick and easy.FeaturesFlush mountingEasy fitment with snap in ceiling fixingEasy clean non reflective white surfaceFully adjustable flowPart A B C D kgRDJ150 150 235 5 95 0.3RDJ200 200 290 5 120 0.6RDO Round Diffuser OutletManufactured from high impact ABS for long term strength and rigidity. Fullyadjustable by rotating the centre cone from total shutoff to fully open. Thestandard colour is off-white. It allows for smooth, quiet airflow that expandsout in a concentric pattern across the ceiling.Features include;Easy one touch adjustment for air flow controlEasy fitment with snap in ceiling fixingTough high impact ABSPart A B C D kgRDO200 200 320 15 90 0.7RDO250 250 400 15 100 1RDO300 300 440 20 100 1.3RAG Return Air GrilleReturn air grilles are manufactured from metal and offer an attractive lowprofile finish for all exhaust air applications. The grilles are supplied with neckadapters for easy connection to commonly used duct sizes. Ideal for ductedair extraction in bathrooms, laundries and toilets.Features include;All metal constructionSizes to suit a wide range of applicationsWhite finishPart A B C D kgRAG150 150 120 200 155 0.6RAG200 150 125 250 210 0.8RAG200W 200 125 250 210 0.8RAG250 200 125 300 260 1RAG300 250 125 350 310 1.3PFG150* 150 151 235 180 0.3* All plastic model324 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Grilles and DiffusersEVS GrilleManufactured from stainless steel, this round flush vent is ideal for under –eave venting. The open mesh face allows it to be used in either wall orceiling applications as an outlet or supply vent. Supplied with insect mesh,screws and rubber gasket.FeaturesFlush mounting18/10 stainless steelRear flange for duct attachmentPart A B C DEVS100 100 150 50 6EVS125 125 185 50 6EVS150 150 210 60 6EVS200 200 265 70 6GVS Gravity Louvred DamperManufactured from stainless steel, this gravity louvred vent, sometimes knownas a flap vent, is designed to provide wall mounted external exhaust forducted systems. The air pressure operated louvres prevent back drafts whenfans are not in use. Supplied with insect mesh, screws and rubber gasket.FeaturesFlush mounting18/10 stainless steelRear flange for duct attachmentPrevents back draftsPart A B C D EGVS100 100 155 50 17 155GVS125 125 180 50 23 180GVS150 150 180 60 23 180GVS200 200 265 75 23 265DVS GrilleManufactured from stainless steel, this dome style vent is ideal for use as asupply or exhaust opening through walls where weather protection is a keyconsideration. Supplied with insect mesh, screws and rubber gasket.Features include;Flush mounting18/10 stainless steelRear flange for duct attachmentCan be used for supply or exhaust airPart A B C DDVS100 100 150 50 10DVS125 125 185 50 10DVS150 150 210 60 10DVS200 200 265 70 10© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 325


FANSCATALOGUEGrilles and DiffusersEVP GrilleManufactured from ABS plastic, this square flush vent is ideal for under - eaveventing. Suitable for use in either wall or ceiling applications as an outlet orsupply vent. Supplied with glass fibre insect mesh.FeaturesFlush mountingDurable ABS plasticRear flange for duct attachmentSnap fit front grille for easy installation and cleaning.Part A B C DEVP100 100 153 30 18EVP125 125 185 30 18EVP150 150 250 30 13EVP200 200 250 30 13E153185250250GVP Gravity Louvred DamperManufactured from ABS plastic, this gravity louvred vent, sometimes known asa flap vent, is designed to provide wall mounted external exhaust for ductedsystems. The air pressure operated louvres prevent back drafts when fans arenot in use. Supplied with glass fibre insect mesh.FeaturesFlush mountingDurable ABS plasticRear flange for duct attachmentPrevents back draftsSnap fit front grille for easy installation and cleaning.Part A B C D EGVP100 100 154 30 15 154GVP125 125 188 30 15 188GVP150 150 250 30 12 250GVP200 200 250 30 12 250326 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Aquaseals, Extension Tubes, Flexible DuctAQS Aquaseal Roof FlashingDesigned to allow watertight penetrations of metal roofs where productssuch as tube mounted fans are to be installed. Manufactured from EPDMrubber with aluminium inserts, the flashings are simple and quick to install.PartBase SizeO.D. Range at 25°Roof PitchO.D. Range at 45°Roof PitchTemp RangeColourAQS1 115 x 115 8-50mm 8-40mm -40° to 115° Black/AlumAQS2 155 x 155 10-90mm 10-70mm -40° to 115° Black/AlumAQS3 203 x 203 40-100mm 40-90mm -40° to 115° Black/AlumAQS4 255 x 255 75-150mm 75-135mm -40° to 115° Black/AlumAQS5 305 x 305 125-200mm 125-180mm -40° to 115° Black/AlumAQS6 355 x 355 145-250mm 145-230mm -40° to 115° Black/AlumAQS7 432 x 432 195-300mm 195-250mm -40° to 115° Black/AlumAQS8 540 x 600 230-380mm 230-355mm -40° to 115° Black/AlumMON Extension TubeMon extension tubes are used in conjunction with AQS Aquaseals to allowroof mounting of circular fans and cowls (RCR Series <strong>Fans</strong>, MAD Cowls).Manufactured from galvanised sheet steel with crimped ends and locatingridges for easy connection to fans and cowls. Tubes can easily be joined toaccommodate steeper roof pitch angles. Powder coat colours are availableas an option when ordering.Part Diameter LengthMON 150 150 600MON 200 200 600Part Diameter LengthMON 250 250 600MON 300 300 600MCU Metallised Core Duct (Uninsulated)A quality duct of metal / polyester laminate construction. High tensilebonded helical wire provides excellent shape retention through bendsensuring ducts retain maximum flow characteristics.MCI Metallised Core Duct (Insulated)Manufactured to the same specifications as MCU duct with the addition ofpolyester Insulation blanket (50mm) and a metallised outer fire jacket.SpecificationsFire Rated AS/NZS 4254-2002. Operating Temperature: -20ºC to +80ºCOperation Pressure: -190pa to 1200paPart Diameter LengthMCU/MCI 100 100 6mMCU/MCI 150 150 6mMCU/MCI 200 200 6mPart Diameter LengthMCU/MCI 250 250 6mMCU/MCI 300 300 6mRED ReducerUsed to transition European standard size fans to local ducting specification.Fabricated from spun aluminium or spot welded galvanised sheet.Sizes315 to 300mm and 160 to150mmNoteWhen using reducers the performance of fans will be de-rated byapproximately 6-7%© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 327


Speed Controllers and SwitchesFANSCATALOGUEIntroduction to Speed ControlThe use of different types of speed controllers allows overall fan capacity,sound level and absorbed power to be managed according to demandrequirements. In many instances, the peak capacity of installed fans may onlybe required for limited duration or to meet specific demand situations.Running fans at full capacity when demand requires less than 100% duty hasbeen identified as a significant source of energy waste in ventilation systems.By incorporating fan speed control, particularly when directed by feedbackfrom electronic management systems, the energy efficiency of installedventilation plant can be greatly increased.The types of speed control most often applied to fans are:TriacStar/Delta SwitchTransformerVSDUsed to control single phase external rotor motors.Simple two speed switching of three phase motors.Ideal for three phase external rotor motors.Highest performance for single or three phase motorsSelecting The Right Speed Control OptionTo simplify the task of selecting the most appropriate method of speedcontrol, all products manufactured by <strong>Fans</strong> <strong>Direct</strong> are cross referenced to thevarious controllers available. When selecting fans using our electronicselection software, <strong>Fans</strong>Select, the relevant speed control option (or options)by model are listed under the ancillaries tab. <strong>Fans</strong>Select is available for<strong>download</strong> at www.fansdirect.com.au.For project wide support regarding speed control methods and costs,contact your local <strong>Fans</strong> <strong>Direct</strong> sales office.The following tables provide a general guide to selecting speed controlstaking into account performance, cost and complexity. The following pagesprovide more detailed information.Single Phase-Electronic Speed ControllersFor Against CommentsLow CostShould not control fans below 60% offull speed. Energy inefficient. Cancreate motor ‘hum’ at low speedsGenerally good for use with smallfans below 0.5kW. Not suitablefor foot or flange mount motors.Single Phase-Transformer Speed ControllersFor Against CommentsVery quiet fan operation, moreefficient than electronic controllers.CostThe best speed control to usewith single phase fans. Can beused with external rotor motorsup to 2kW.Three Phase-Transformer Speed Controllers (for external rotor motors)For Against CommentsVery quiet fan operation. Cost and size Easy, five step speed controlfor external rotor motorsThree and Single Phase-Variable Speed DriveFor Against CommentsVery quiet fan operation , widespeed range, control inputs andsignals.Cost and ComplexityThe best way to control threephase fans.Note: It is not recommended to speed control conventional single-phase motors with triac type controllers due toheat build up and noise.328 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Speed Controllers and SwitchesPart IP20Part IP54Motor OutputkWDRV Series Variable Speed DrivesThe DRV Series is a range of high performance speed controllers that changemotor speeds by modifying the frequency of the electrical supply. Currentgeneration drives offer exceptional efficiency of up to 98% and can besupplied for use as components in building management systems or forapplication to individual or groups of fans.DRV Drives are BACnet compatible as standard for integration with BMSnetworks although Modbus RTU and Metasys N2 versions are available.When selected in combination with higher efficiency motors, intelligent speedcontrol offers the highest energy savings currently available in HVACapplications.FeaturesIntegrated network connectivity with multiple standards.Sleep / Wake mode for demand management.Low load detection to sense system mechanical problems.Smartcard data storage.High switching frequency of up to 16kHz for quiet motor operation.Available with either IP20 or IP54 enclosures.On board temperature control ensures uninterrupted drive performance.Flexibility to work with BM Systems or stand alone applications.Simple and intuitive keypad / LCD interface.Compact size.Ethernet communications option available.Selecting The Right VSD OptionTo simplify the task of selecting the most appropriate VSD, all productsmanufactured by <strong>Fans</strong> <strong>Direct</strong> are cross referenced to the various drivesavailable. When selecting fans using our electronic selection software,<strong>Fans</strong>Select, the relevant VSD option (or options) by model are listed under theancillaries tab. <strong>Fans</strong>Select is available for <strong>download</strong> atwww.fansdirect.com.au.Installation and commissioningCorrect installation, wiring and setup of VSD’s is essential to avoid damage tothe drives and to ensure Electro-Magnetic Compliance (EMC) regulations areadhered to. For project specific support regarding selection and installationof VSD’s contact your local <strong>Fans</strong> <strong>Direct</strong> sales office.Max Cont.CurrentDRV20-01100-3 DRV54-01100-3 1.1 2.8DRV20-01500-3 DRV54-01500-3 1.5 3.8DRV20-02200-3 DRV54-02200-3 2.2 5DRV20-03000-3 DRV54-03000-3 3 6.9DRV20-04000-3 DRV54-04000-3 4 8.8DRV20-05500-3 DRV54-05500-3 5.5 11DRV20-07500-3 DRV54-07500-3 7.5 15.3DRV20-11000-3 DRV54-11000-3 11 21DRV20-15000-3 DRV54-15000-3 15 29DRV20-18500-3 DRV54-18500-3 18.5 35DRV20-22000-3 DRV54-22000-3 22 43DRV20-30000-3 DRV54-30000-3 30 56DRV20-37000-3 DRV54-37000-3 37 68DRV20-45000-3 DRV54-45000-3 45 83DRV20-55000-3 DRV54-55000-3 55 104DRV20-75000-3 DRV54-75000-3 75 138Frame SizeWDRV20WDRV54HDRV201 100 184 386 5602 155 236389H DRV54 D DRV20D219DRV54KgDRV20KgDRV54264 5 9552 262 7 123 250 331 544 260 302 15 254 310 386 547 703 298 346 30Notes: For sizes 1-4 (DRV20) and 1-3 (DRV54) drives, the continuous ratings given are for maximum40°C [50°C with derating], 1,000m altitude and 3.0kHz switching. For size 4 DRV54 drive, thecontinuous rating given is for maximum 35°C [40°C with derating], 1,000m altitude and 3.0kHzswitching. Select drives on actual motor full load current. All drives include keypad and internalEMC filters.40© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 329


FANSCATALOGUESpeed Controllers and SwitchesVA Series Speed ControllerThe VA series of speed controllers offers a comparatively low cost option forvarying the flow, power consumption and sound levels of single phase fanswith a current rating of up to 10 amps. Speed control ranges from 100%down to approximately 30%.NotesVA speed controllers are recommended for external rotor motor fans toensure adequate cooling under speed control conditions. They should notbe used to speed control fans with conventional foot or flange mount singlephase motors other than models designated as being speed controllable.Refer to the wiring diagram packaged with the controller for specificinstructions relating to installation. PSC (Permanent Split Capacitor) motorscan be installed with three wire configuration to help minimise motor hum.When more than one fan is to be controlled, the fans should be of the sametype and capacity with the combined full load current not exceeding 85% ofthe controller FLC rating.Part Notes Max. Amps MountingVA500B On/Off Switch, Triac Control 2.0 Wall PlateVA500-PIL Plug in Triac Control 2.0VA500-GAW* On/Off Switch, Triac Control, FWD/REV Switch 2.0 Wall PlateVA700B-NEON On/Off Switch, Triac Control, Neon Indicator 2.9 Wall PlateVA700B-FITTED Equipment or enclosure mount, no switch 2.9 BracketVA1200B On/Off Switch, Triac Control 5.0 Wall PlateVA2400 On/Off Switch, Triac Control 10.0 Wall Plate* For use with GAW230 and GAW300 wall and window fans only.RE and RD Series Speed ControllerThe RE (single phase) and RD (three phase) series of speed controllers offers 5step speed adjustment using transformer type voltage control. Speed controlranges from 100% down to approximately 30%.NotesRE and RD speed controllers are recommended for external rotor motor fansto ensure adequate cooling under speed control conditions. They should notbe used to speed control fans with conventional foot or flange mount motorsother than models designated as being speed controllable by voltageadjustment. Refer to the wiring diagram packaged with the controller forspecific instructions relating to installation.When more than one fan is to be controlled, the fans should be of the sametype and capacity with the combined full load current not exceeding 85% ofthe controller FLC rating.PartV/PhaseMax.AmpsProtection D H W KgRE1.5G 240 Single 1.5 IP54 80 180 105 2RE2G 240 Single 2.0 IP54 114.5 230 166 2.2RE3.5G 240 Single 3.5 IP54 114.5 230 166 3.5RE6G 240 Single 6.0 IP54 114.5 230 166 5RE7.5G 240 Single 7.5 IP54 115 284 240 6RE9G 240 Single 9.0 IP54 115 284 240 10.5RE12 240 Single 12.0 IP21 148 323 270 10.5RE14G 240 Single 14.0 IP54 148 323 270 12.5RD1G 415 Three 1.0 IP54 115 284 240 4.5RD2G 415 Three 2.0 IP54 115 284 240 7.2RD3G 415 Three 3.0 IP54 146 323 270 10.8RD4 415 Three 4.0 IP21 146 323 270 11RD5.2G 415 Three 5.2 IP54 146 323 270 15.6RD7 415 Three 7.0 IP21 146 323 270 15.6330 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Speed Controllers and SwitchesStar / Delta Switch Speed ControllerStar/Delta switches allow speed control of three phase motors. They provideon/off and high/low speed by changing between the star or delta wiringconfiguration of the motor. Suitable for all three phase external rotor motorsand most three phase motors fitted to axial flow fans.NotesTwo versions are available for either recessed panel mount or surface mount.The switches do not provide motor protection.Part Max. Amps Mounting Protection DimensionsSD SWITCH 20 Panel (recessed) IP65 (from front) H110 x D50 x W50SD 20 Surface IP65 H140 x D120 x W80ROTV Run On TimerRun on timers are wired with a permanent active feed allowing the fanplugged into the unit to continue running for a pre-determined time periodafter the wall switch has been turned off. Ideal for use in toilets andbathrooms where continued extract ventilation after leaving the room is apractical solution.NotesROTV’s are available in pre-wired configuration with four pin plugs or as abare unit for wiring in on site. Run on time can be set from 2 to 20 minutes bysimple screw driver adjustment.Part Max. Amps Mounting DimensionsROTV-PIL (4 Pin Plug In Lead) 5 Surface H115 x D52 x W115ROTV (Wire In Unit) 5 Surface H115 x D52 x W115© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 331


FANSCATALOGUE332 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


<strong>Fans</strong> and Air Movement Essentials1 Properties of airFor the purposes of this section we will assume that it is air that will bemoved by the various types of fans.The air we breathe is made up of a mixture of gasses - nitrogen 78%,oxygen 21% and 1% trace gasses including carbon dioxide. All of thesegasses have mass In the atmosphere, the weight of these gassesproduce a pressure (approx, 101,325 Pa at sea level depending on theweather).The mass and pressure result in air having a density 1.2kg m 3 which isconsidered the standard density of air. Air Density changes withconditions and can be affected by temperature as well as atmosphericvariations due to high and low pressure systems. Higher or lower altitudealso correspond with higher or lower density and pressure.2 Air flow and air pressureAs fans provide the means to move air, the relevant variables are thevolume flow rate required and the pressure that must be overcome inorder to deliver the volume. The graphical intersection of volume air flowand pressure required (in an X Y scatter chart) describes the fanperformance duty needed for a particular application.2.1 Measurement of air flowAir flow is the measurement of the quantity of air that is conveyed in agiven time period;L/s (litres per second)m 3 s -1 (cubic metres per second)m 3 hr -1 (cubic metres per hour)CFM (cubic feet per minute)2.2 Measurement of air pressureAir pressure is the force per unit area exerted by air;Pa (Pascals)KPa (Kilopascals)In.WG (Inches Water Gauge)Mm.H2O (mm water gauge)PSI (Pounds per square inch)In relation to fans and air movement there are five pressure variables tobe considered.Static pressureThe difference between the absolute pressure at a point in an airstream,usually inside a duct and the pressure of the outside atmosphere. Staticpressure acts equally in all directions, is independent of velocity and is ameasure of the potential energy available in an air stream.Velocity pressureIs the measure of energy available in an airstream and is always positive.Total PressureThe sum of static and velocity pressure. It is a measure of the total energyavailable in an air stream.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 333


<strong>Fans</strong> and Air Movement EssentialsFANSCATALOGUEFan total pressureThe difference between the mean total pressure at the fan outlet andthe total pressure at the fan inlet.Fan impeller typesFan static pressureThe fan static pressure is a defined quantity used in rating fans andcannot be measured directly. It is the fan total pressure minus thevelocity pressure corresponding to the mean air velocity at the fan outlet.Note that it is not the difference between the fan static pressure at theoutlet and the static pressure at the inlet; that is, it is not the externalsystem static pressure.3 How fans workA fan is a rotating bladed device which continuously applies energy toair or gas passing through it. There are three main components to a fan;the impeller, a means to drive the impeller and the casing.Energy is transferred to the air by rotation of the impeller being one of thethree main types commonly used; centrifugal, axial or mixed flow.CentrifugalIn the centrifugal type, it is the centrifugal force generated by the massof air contained within the impeller at any given instance, as well as theforce exerted by the angle of the blades to the entering air which gives itboth static and velocity pressure and therefore moves air through thesystem.In the axial type there is little or no centrifugal action; the blades beingset at an angle relative to the direction of air entry generate a lift orpressure difference.In the mixed flow type, energy is imparted to the air by a combination ofcentrifugal force and lift. As the name suggests, this type of fan displaysa mix of characteristics seen in both axial and centrifugal fans.Axial (sickle blade type)The casing is not simply an enclosure for the impeller to channel air in acertain direction. It plays an important part in the aerodynamicperformance particularly in the case of centrifugal and mixed flow fanswhen it is often the major element which converts velocity energy touseful potential energy (static pressure) and in axial fans where impellertip clearance is important.4 Fan type characteristics4.1 CentrifugalMixed FlowAir enters the impeller axially and is discharged radially into a volute orscroll shaped casing. These fans offer medium to low volume flow rates atmoderate to high pressures. The main varieties are characterised by thetype and angle of the impeller blades.A) Backward types may consist of aerofoil sections or single thicknessblades, the latter being either curved or straight. These impellers typicallyhave few blades. The pressure curve generated by this impeller type isrelatively steep over the working range and the power curve has a nonoverloadcharacteristic. Very good efficiencies are possible with this typeof impeller.B) Forward curve types are characterised by a larger number of shallowblades sloping forward in the direction of rotation. The power curve forthis type of fan rises steeply from zero to maximum flow making this typeprone to overloading its driving motor if operated beyond the rated dutypoint. It will handle relatively large volumes of air at lower operatingspeeds however, overall efficiency is less than backward inclinedblading.334 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


<strong>Fans</strong> and Air Movement EssentialsC) Radial blades produce a near straight power curve from a minimumat zero flow to a maximum at maximum air flow although the curve is notas steep as for a forward curve impeller. The blades tend to be selfcleaning and can handle moderately dirty conditions.4.2 AxialIn this type, air enters and leaves the fan axially in a straight throughconfiguration. Duties are usually medium to high volume flow at mediumto low pressures. In its simplest form a single impeller is direct driven by amotor in a cylindrical casing. The discharge flow embodies apronounced swirl or twist to the airstream which may, if not corrected,materially increase the resistance of the downstream portion of thesystem. This swirl can be removed by fitting guide vanes either upstreamor downstream of the fan. The removal of swirl increases the efficiency ofthe fan. A further variation to remove swirl is the use of twoindependently driven contra-rotating impellers within a single casing.Axial types have non overloading power characteristics and can displayvery good efficiencies.4.3 Mixed FlowThis type of fan has an air path through the impeller which hascharacteristics of both axial and centrifugal types. Mixed flow impellersare designed to provide both axial and radial discharge. Higher fanstatic pressures are achievable with this type of impeller compared toaxial fans.5 Presenting Fan PerformanceFan performance is typically represented graphically using x-y scattercharts with points plotted at intersections of static pressure and air flow.Data series presenting the working range of the fans are plotted tographically illustrate performance as a line or curve. Multiple fans ofsimilar type, for example axial flow fans with adjustable pitch blades, arepresented as groupings of curves within the one graph.900800700600500400300Static Pressure, Pa20010010°15°20°25°30° 35° 40°00 1 2 3 4 5 6 7Volume m 3 /s© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 335


<strong>Fans</strong> and Air Movement EssentialsFANSCATALOGUE5 Fan DutyThe points along the fan curve represent the outflow of air at varyinglevels of system resistance (static pressure). The required fan performancefor flow rate at the designed pressure level is the duty point that the fan isrequired to meet. Represented graphically, the duty that is required is apoint along a calculated curve known as the system curve.350300Pressure (Pa)25020015010050Fan CurveSystem CurveDuty Point00 1000 2000 3000 4000 5000 6000 7000Air Flow (L/s)It should be remembered that the fan performance presented in thiscatalogue has been derived through testing to recognised standards. Inarriving at duty requirements for fans, designers are advised to pay closeattention when determining overall system resistance to ensure that fansperform to published levels.6 Fan ApplicationsAlthough typically thought of as a means to provide airflow in airconditioningsystems, fans are applied to a diverse range of airmovement tasks in a wide range of environments. The following sectionsprovide an overview of more specialised fan applications.6.1 Smoke SpillSuch systems are intended to limit and control the movement of smokeduring a fire.The most common technique involves pressurizing the areas on eitherside of the compartment where the fire is located and exhausting fromthe fire area.This method creates a ‘pressure sandwich’ which tends to move air (andthus smoke) from the protected areas towards the fire whilst movingsmoke out of the fire area. Although this does introduce fresh oxygen tothe fire area, most systems are aimed at protecting the occupants andequipment in the compartments adjacent to allow evacuation and toallow firemen clear access to the fire to extinguish it.Generally in Australia, smoke spill fans fall into two categories.Tested to withstand 200°C for two hours.Tested to withstand 300°C for one half of one hour.If an area that requires smoke spill fans has fire sprinklers serving it, thenfans tested for 200°C for two hour are acceptable.Smoke-spill fans have to be tested to Standard AS4429:1999 and conformwith the requirements of AS/NZS1668.1:1998.336 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


<strong>Fans</strong> and Air Movement Essentials6.1 Smoke Spill <strong>Fans</strong> (continued)Smoke spill fans can be roof mounted, plate mounted, in line axial, in linecentrifugal.For 300°C 30min smoke spill <strong>Fans</strong> in buildings without sprinkler systems,dampers shall remain open in the event of fire.<strong>Fans</strong> <strong>Direct</strong> utilises a fusible link – Damper Open device on all VD and LEfans in 300°C 30 min smoke spill applications6.2 Hazardous Location <strong>Fans</strong>The selection of fans in hazardous locations has to take into account foursets of information.The area classification.The gas group.The “T” rating or ignition temperature of the hazard.The required “IP” rating of the apparatus.6.2.1 Area ClassificationThe areas are classified into ZONES, and these zones are based on thefrequency of the appearance of an explosive atmosphere and theduration for which it can last.Summarized as follows:Gases and VapoursZone 0Area in which an explosive gas-air mixture is continuously present orpresent for long periods.Zone 1Combustible or conductive dusts are present. Area in which an explosivegas-air mixture is likely to occur for short periods in normal operation.Zone 2Area in which an explosive gas-air mixture is not likely to occur, and if itoccurs it will only exist for a very short time due to an abnormal condition.DustZone 20Area in which an explosive dust-air mixture is continuously present orpresent for long periods.Zone 21Combustible or conductive dusts are present and is likely to occur forshort periods in normal operation.Zone 22Area in which an explosive dust mixture is not likely to occur, and if itoccurs it will only exist for a very short time due to an abnormal condition.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 337


<strong>Fans</strong> and Air Movement EssentialsFANSCATALOGUE6.2.2 Gas GroupsGas Groups are divided into two categories.Group 1.Coal Mining Industry. (Methane)Group IIOther Industries.Group II is further subdivided as follows and the representative gases foreach group are shown as well:Group I - MethaneGroup IIA - PropaneGroup IIB - EthyleneGroup IIC - Hydrogen6.2.3 Temperature or “T” ratingThe source of ignition in a hazardous area can be an arc or a spark oreven a hot surface.Since electrical equipment generates heat in normal operation we needto ensure that a hot surface on electrical apparatus cannot ignite asurrounding explosive gas atmosphere or a dust cloud or layer.All hazardous materials have what is known as an “Ignition Temperature”.This is the minimum temperature at which the hazardous material whenmixed with air will ignite and sustain combustion, without an ignitionsource (auto-ignition or spontaneous ignition).The temperature of a layer on the surface of the equipment.Eg. if the ignition temperature of the dust layer is 275° C then theequipment T rating must not exceed 200ºC or T3.6.2.4 Ingress Protection (IP) RatingsDesignationFirst digit protection againstcontact and ingress of foreignbodies.Second digit protection againstwater.IP44IP54IP55IP56IP65IP66Protection against contact withparts inside the enclosure byforeign objects including wireswith a diameter greater than1mm.Protection against contact withparts inside the enclosure byforeign objects including dust.Protection against dust ingress isnot total but not in amounts thatwill interfere with the operation ofthe equipment.Complete protection againstcontact with parts inside theenclosure by foreign objectsincluding dust.Protection against water sprayedfrom any direction.Protection against water sprayedfrom any direction.Protection against beamedwater directed by a nozzle.Protection against stronglybeamed water jets or heavyseas.Protection against beamedwater directed by a nozzle.Protection against stronglybeamed water jets or heavyseas.338 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


<strong>Fans</strong> and Air Movement Essentials6.2.5 Types of motors used in Hazardous locationsEXNIs a level of protection that states the motor will in normal operation notignite a surrounding area, and that any ignition is unlikely to happen.EXEExe protection is also known as increased safety, this level of protection issuch that the motor does not produce arcs or sparks under normal use.Generally used in spray booth applications.EXDThese are motors that are built to withstand an internal explosion withinthe motor casing and will not transmit any flame or spark that couldignite surrounding gas or vapours. They also operate at external surfacetemperatures that do not allow ignition of surrounding gas or vapours.DIPThese motors use suitable enclosures to prevent arcs and sparks or heatto be liberated inside the enclosure to ignite any exterior dust on or nearthe motor. Used in heavily dust laden environments.6.3 Fresh Air Supply <strong>Fans</strong>Fresh air is introduced to air conditioned spaces to maintain adequateventilation rates and to flush out contaminants. The level of fresh airintroduced depends mainly on the type and function of the space andthe number of occupants utilising the area at any given time.These fans should deliver fresh air ventilation rates in accordance withAustralian Standard (AS) 1668 Part 2, which range from 7.5 litres persecond per person to 15 litres per second per person.These fans are also known as supply air fans and can be roof units, in lineaxial, centrifugal or any type of fan depending on the design.6.4 Car Park Exhaust and Supply <strong>Fans</strong>Compliance with AS1668.2 requires that the internal environment of a carpark is safe for occupants and that if the internal air quality is acceptableto health, it is concluded that the air quality of any discharges eitherthrough mechanical or natural ventilation are equal to or better thanthat in the car park.Car park exhaust fans should always have aluminium impellers, F classmotors are acceptable.Car park supply fans can have plastic, glass reinforced nylon or fibrereinforced plastic impellers, again class F motors are acceptable.Car park supply fans can also have aluminium impellers however plasticis less costly.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 339


<strong>Fans</strong> and Air Movement EssentialsFANSCATALOGUE6.5 Stairwell PressurisationStairwells are frequently the primary escape routes for the occupants of abuilding in a fire emergency.In addition, the stairwells may be the primary access routes for the firefighting teams responding to the emergency. Thus, it is critical that theyremain clear of smoke for as long as is necessary to safely evacuate thebuilding and bring the fire under control.Most high rise buildings employ a stairwell pressurization system to keepthe stairs clear of smoke while operating at a low enough pressure thatan average person can open the doors to enter or exit the stairwell ontheir way to safety.Stairwell pressurization fans are fairly standard in construction and areusually in line axial type, but not limited to this type of fan. Standardmotors meet the code requirements.7 Fan Laws7.1 About Fan LawsIt is not practical to test fans of every size with differing variables such asgas density or rotational speed. Fortunately, by the use of fan laws, theperformance of geometrically similar fans of different sizes or speeds canbe predicted with sufficient accuracy for practical purposes. These lawsare most often used to calculate changes in flow rate, pressure, soundand power of a fan when size, rotational speed or gas density ischanged. In the following laws, the suffix ‘1’ has been used for the initialknown values and the suffix ‘2’ for the changed values and the resultingcalculated value.7.1.1 Fan Law for VolumeVolume ∝ Speed. Volume flow changes in direct proportion to fanspeed.Qæ N= Q çöæD÷ çö2 22 1ç÷ ç ÷ è N1øèD1ø3Where: Q = flow rate, N = fan rotational speed, D = impeller diameter7.1.2 Fan Law for PressurePressure ∝ Speed 2. Pressure changes in direct proportion to the square ofthe fan speed ratio.æ NP =ç2P1è N212ö æ D2÷çø è D12ö æ r ö2÷ç÷ø è r1øWhere: P = pressure N = fan rotational speed, D = impeller diameter,ρ = density of air340 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


<strong>Fans</strong> and Air Movement Essentials7.1.3 Fan Law for PowerPower ∝ Speed 3 Power required changes in direct proportion to thecubed power of fan speed.W2æ N= Wç1è N213ö æ D2÷çø è D15ö æ r ö2÷ç÷ø è r1øWhere: W = power N = fan rotational speed, D = impeller diameter,ρ = density of air7.1.4 Fan Law for SoundPower ∝ Log (speed)æ N ö æ ö2D2Lw = +ç÷ +ç÷2Lw150Log1070Log10+ 20Logè N1ø è D1øæ r ö2ç÷è r1øWhere: Lw = sound power level, N = fan rotational speed, D = impellerdiameter, ρ = density of air10<strong>Fans</strong> <strong>Direct</strong> acknowledges the Australian Institute Of Refrigeration, Air Conditioning and Heating (AIRAH) for theirpermission to reproduce extracts from their technical bulletin DA13 in this catalogue section.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 341


FANSCATALOGUEInstallation and MaintenanceDelivery:Upon receipt of fans, thoroughly inspect units for any damage sustainedduring transit. If damaged, contact <strong>Fans</strong> <strong>Direct</strong> or your supplying distributorimmediately.Site Storage:If the fan is not installed immediately, it should be stored in a clean, dry andpreferably warm environment. Fan impellers should be rotated occasionallyto prevent motor bearing damage.Safety:Rotating fan impellers and electric motors can be dangerous topersonnel, only experienced qualified persons should carry out work on theseproducts. The following precautions must be taken:¨¨¨¨¨Electrically isolate the fan motor prior to undertaking any work.Check that all fasteners, particularly impeller fasteners, are tight prior tostart up. Do not re-use locking fasteners.Loose objects are not only a safety hazard but may also cause majordamage. Ensure all attachments of any sort are secure and can not bedrawn into the impeller.Always use protective guards where fans are accessible to personnelor directly exposed to habitable areas.Ensure that loose debris will not be sucked into the fan prior to fan startup. All duct work should be clean.Electrical Supply:Check that suitable supply is available. The voltage, frequency, number ofphases and full load amperage are marked on the fan nameplate. Beforeinstallation the resistance to earth should be measured and if less than1 mega ohm the motor should be tried out before applying mains voltage.Wiring:Refer to the latest product datasheet for individual model wiring instructions. Itis the responsibility of the user to connect thermal contacts where providedto protect the motor. It is a condition of our warranty that all equipmentsupplied is installed according to the requirements of AS/NZS3000:2007Australian/New Zealand wiring rules. Check carefully the motor nameplateand associated connection diagrams prior to wiring.Three phase motors require a trial connection to the supply to ensure correctdirection of rotation as marked on the casing. Interchange any two phasesof the 3 phase supply to change the direction of rotation. For External Rotormotors only, some three phase fans must be wired in “Star”, if wired in “Delta”they will burn out and motor warranty is void. Others may be wired in either“Star” or “Delta”, dependent on speed required. Please check the wiringdiagram supplied with the motor. Check rotation direction in both speeds.342 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Installation and MaintenanceCircuit Protection:Fuses in the circuit should be regarded as protecting the wiring to the motorand not motor overload protection. Single phasing protection and currentoverload protection must be provided. Failure to provide this protection willvoid the warranty. The overload protection devices must be correctly set toprotect the motor. Motors fitted with thermistor or thermostatic overheatprotection (wires marked “TK”) must be suitably wired into the control circuitto interrupt motor power supply on winding temperature rise.Motors:All standard motors are suitable for operation in air temperatures between-20° and +40°. If higher temperatures are required, contact your nearest <strong>Fans</strong><strong>Direct</strong> representatives for advice.Starting:All fans are suitable for direct-on-line starting manually or automatically up toand including 5.5kW. The number of starts should be limited to no more thanfour direct-on-line starts per hour or, no more than eight starts per hour formotors up to 1kW.Maintenance Checking:Inspection of the fan is recommended initially after 3 months to ensure thatthere is no build up of dirt or other matter that would cause overheating ofthe motor. Standard motors are not suitable to handle saturated aircontaining water droplets or some corrosive fumes. For severe applications,special motors and finishes may be required. For axial fans the blades andmotor should be clean and the tightness of the fastenings should bechecked. Overloads should be inspected to ensure correct operation. Due tothe different periods of operation from the time of installation andconditions of use, no rigid inspection and maintenance periods can berecommended. It is suggested that the inspection and if necessary cleaning /bearing check should be carried out at regular intervals of a maximum of sixmonths.Note:Before proceeding with routine maintenance ensure that:-¨¨the fan and speed control, if fitted, are electrically isolated.sufficient time is allowed for impeller to stop completelyIt is recommended that all <strong>Fans</strong> <strong>Direct</strong> products are maintained inaccordance with the HVAC “Standard Maintenance Specification forMechanical Services in Buildings” - Volume II Ventilating and Air Conditioning.Maintenance Instructions:To obtain maximum service life of your fans, it is recommended the followingmaintenance be implemented and recorded in a plant log book.1. Ensure air intake space is unobstructed to avoid overheatingthe motors.2. On a weekly basis use an air hose to ensure all airways are clear andfree of dust if the fans are not used.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 343


FANSCATALOGUEInstallation and Maintenance3. Do not wash the fan motor down unless the motor is IP66 rated.4. On a quarterly basis1. Check motor terminals for tightness and contact.2. If terminal lugs are discoloured, re-terminate.3. Check the operation of starting equipment, ensuring allterminations are tight.4. Check mechanical operation of thermistor relay (if fitted).5. Check operation of space heaters ( if fitted).5. On a six (6) monthly basis, in addition to the above in item 41. Check stator resistance (compare to original and enter in logbook).2. Check supply voltage at motor terminals.3. Check bearings for noise / overheating.4. Check the tightness of fastening.6. On an annual basis, in addition to the above in items 4 and 51. Strip motor out and clean thoroughly.2. Check bearings for wear / damage - Replace as necessary.3. Check all fastenings and impeller blades for cracks or damage -Replace as necessary.4. After re-assembly, check and record:Full load CurrentFull load VoltagesFull load Speed7. Ensure plant log book records commissioning data and comparemaintenance data to original.8. Contact your nearest <strong>Fans</strong> <strong>Direct</strong> office for any part replacement.Cleaning ImpellersIt is recommended that a stiff brush be used to remove any build up of dirt.Care should be taken not to damage or distort the impeller blades. Ifthorough cleaning on site is not possible, proceed as follows:-1. Remove the impeller by removing retaining screw to take impellerout from motor shaft while retaining motor shaft key. ExternalRotor Motor Axial and Centrifugal fan impellers cannot be removedfrom motor and they have to be cleaned on site.2. Remove all loose dirt using a stiff brush3. Sponge the impeller with warm soapy water4. Rinse thoroughly in clean water and wipe dryDO NOT USE SOLVENTS OR CAUSTIC FLUIDSUNDER NO CIRCUMSTANCES MUST THE MOTOR BE SUBMERGED IN WATER344 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Installation and MaintenanceInstallation Guide for Roof Mount <strong>Fans</strong>1. Ensure that curbs / upstands are flat true square.2. Ensure a suitable foam sealant strip to fix on top ofcurbs / upstands to prevent air leakage through thegap between the curbs / upstands and the fan bases.3. Ensure roofing screws are fastened securely throughthe side midway through the skirt to preventwater leakage to the building4. Ensure roof vertical discharge fans with shutterdampers are installed with the hinge line parallel withthe slope of the roof.5. Ensure the connecting duct size matches thespecified size for the fan.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 345


Installation and MaintenanceFANSCATALOGUEInstallation Guide for Duct Mount <strong>Fans</strong>1. Install inlet cones to fan inlet if no duct connection tofans.2. <strong>Fans</strong> should be mounted at least one fan diameter ‘D’from any obstruction.3. <strong>Fans</strong> should never be terminated abruptly at thedischarge outlet. Install a two diameter ‘D’ duct pieceor 1.26 diameter ‘D’ and one diameter ‘D’ lengthexpander.4. Expanders at inlet side of fans should not have aninclusive angle greater than 15° and a duct should beinstalled at the outlet of fans.5. In confined spaces do not connect 90° small radiuscircular bends. A square bend with turning vanes ispreferable.6. Flexible duct connectors either side of fans should betaut.346 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 347


FANSCATALOGUEFan Trouble Shooting1. ElectricalProblem Possible Cause ActionFan not running No electrical supply Check electrical supply and ensurecorrect match to motor requirement.Overload devices trippedBlown fuse or tripped circuit breakerLoose electrical connections in junctionboxReset overloads.Check motor and wiring before resettingcircuit breaker or replacing fuses.Check all connections and tighten orreplace terminal lugs.Wrong rotation direction Incorrect wiring Check wiring against diagram in junctionbox or on fan datasheet and correct asnecessary. For three phase fans, reverseany two supply cables.Humming sound from motor Incorrect electrical supply Check motor plate matches electricalsupply.Electronic speed controllerIncorrectly installed VSD speed controllerOverloaded motorImbalanced phases in three phase supplyReplace with transformer type controller.Check installation of VSD againstmanufacturers specifications.Ensure correct motor is fitted for theimpeller size and/or pitch angle (axials).Check that supply phases are correctFan rotates in alternating directions Capacitor faulty or not correctly wired Check wiring and replace if faulty.Excessive current draw Undersized motor for required duty Check motor plate and replace motor ifrequired.Incorrect blade pitch angle (adjustablepitch axial fans)Impaired rotation of impellerIncorrect electrical supplyThree phase motor operating with onephase disconnectedMotor incorrectly wired for star or deltaoperationCheck and adjust pitch angles.Check for obstructions to impeller spinningfreely.Check that supply matches motor plate.Check power supply or motor windings.Check motor plate and wiring diagramand correct as required.Overheating Frequent start ups Check control system and adjust downnumber of starts per hour to eight or less.Dirty cooling fins on motorBlocked cooling vents on motor shroudsCooling fan not fitted to motor out ofairstreamMotor incorrectly wired for star or deltaoperationClean motor.Clear dirt and obstructions from coolingvents.Check fitment of cooling fan.Check motor plate and wiring diagramand correct as required.348 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Fan Trouble Shooting2. General MechanicalProblem Possible Cause ActionVibration Damaged impeller Check for chipped of broken blades andreplace as necessary.Bent motor shaftOut of balance impellerNormal vibration not isolated fromstructureDirty fan bladesReplace motor.Remove and re-balance impeller.Ensure correctly load rated anti vibrationisolators are fitted.Clean blades as required.Bearing noise Inadequate lubrication Grease as required.Failed bearingsReplace as required.Seal squeal Dry shaft seals Lubricate as required.Air squeal or whistling Poor seals at duct / fan joins Re-seal as required.Impeller / Fan excessively noisy Bent blades Remove and replace blades whererequired, note that impeller may need tobe re-balanced as a complete assembly.Dirt build up on bladesLoose blades at hubImpeller touching caseFan running in stallImpeller loose on motor shaftInadequate blade tip clearanceImpeller misaligned with inlet cone(centrifugal)Damage to inlet cone (centrifugal)Clean blades as required.Check fitment of each blade at its rootand ensure all hub nuts and bolts aretightened to correct torque settings.Motor may have moved out of alignmenton its mounting plate. Loosen motor boltsand adjust position until blades are free.Check that the fan’s rated performance isnot selected too high on the publishedperformance curve and replace orchange duct / system design to reducethe load on the fan.Check and tighten to specified torquesetting.Impeller may need to be trimmed andre-balanced.Check and adjust as required.Repair or replace as required.3. General PerformanceProblem Possible Cause ActionAir flow low Air leakage in duct system Check connections throughout.Ducting is undersizedIncorrect pitch angle (axial fans)Wrong sized fanFan running in reverse directionUndersized ducting and fittings willincrease system pressure and reduce flowaccordingly. Unless changes can bemade to the ducting a higher rated fanwill need to be installed.Check pitch angles against fanspecification and correct as required.Check against system requirements andreplace as required.Check fan rotation and wiring to correct.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 349


FANSCATALOGUEFan Trouble Shooting3. General Performance (continued)Problem Possible Cause ActionDampers not adjusted correctlyTurbulence in duct systemDirty filtersLow fan speedCheck position of all system dampers andcorrect as necessary.Install guide vanes to inlet side of axial fansto prevent air rotation. Install turning vanesin bends. Ensure transitions are designedwith appropriate length and angle toprevent losses.Remove filters and re-check performance,clean as required and reinstall.Check motor plate for correct shaft speedand change if required. Check speedcontrol device settings and correct asrequired.Air flow high Ducting is oversized Oversized ducting and fittings will reducesystem pressure and increase flow. Installdampers or speed control devices to fansto bring system back to correct balanceWrong sized fanIncorrect pitch angle (axial fans)Check against system requirements andreplace as required.Check pitch angles against fanspecification and correct as required.350 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 351


Terms & Conditions - Australia1. GENERALIn these terms and conditions (unless the context requires otherwise):“Carrier” means a Carrier nominated by the Company to take delivery of the Goods;“Company” means <strong>Fans</strong> <strong>Direct</strong> Pty Ltd ABN: 80 087 430 715“Consignment Address” means the delivery address of the Customer stated in an Order or otherwiseagreed by the Company;“Customer” means any person who enters into a contract with the Company for the purchase ofGoods and includes:(i) any successors or permitted assigns; and(ii) if the Customer consists of more than one person both of them jointly and eachof them severally;“Goods” means any goods supplied or to be supplied by the Company as specified in an Orderaccepted by the Company.“GST” means GST within the meaning of A New Tax System ( Goods and Services Tax ) Act 1999 (asamended) ( “GST Act” )“Order” means a Customer order placed with the Company for the supply of Goods;“Related Body Corporate” has the same meaning as in the Corporations Act.2. QUOTATIONSA quotation by the Company shall be an invitation to treat, and shall not constitute an offer. Anymodification to a quotation will be effective only if it is expressed in writing and signed by a dulyauthorised officer of the Company.3. CONTRACT FOR SALE OF GOODS3.1 Each Order constitutes an offer by the Customer to acquire the Goods subject strictly to these termsand conditions and to the exclusion of any other terms and conditions asserted by the Customer. Acontract will be made between the Company and the Customer for the supply of Goods only when anOrder is accepted by the Company in writing, orally or by conduct.3.2 The Company may at any time refuse to extend credit to the Customer and need not give any reasonfor its refusal.3.3 These terms and conditions supersede all previous terms and conditions and may only be varied ifauthorised in writing on behalf of the Company.4. PAYMENT4.1 The price for the Goods must be paid within 30 days from the date of delivery of the Goodsto the Customer unless other terms of payment are expressly stated in writing and signed by theCompany.4.2 In the event the Customer fails to make payment to the Company when payment falls due, theCompany shall have the right, without prejudice to any other right or remedy the Company may beentitled, to charge interest on any overdue invoice at a rate of 2% per annum in excess of the rate ofpenalty interest current at the date of default pursuant to the Penalty Interest Rate Act 1983 (Vic)calculated and payable daily and compounded from the due date until the invoice is paid in full. TheCustomer also must pay all costs and expenses (including legal costs), which may be incurred by theCompany in the recovery of the overdue amounts. Any payment by the Customer shall be creditedfirst against any interest so accrued and the balance, if any, shall be applied in reduction of theoutstanding balance of the price.4.3 Notwithstanding that the Customer may be granted time to pay for the Goods and/or services orcredit facilities are provided, the Customer must, in the event the Goods are sold and the proceeds ofsale received, where applicable, comply with clause 9.4.4 The extension of credit facilities and the terms upon which such credit is provided are, in all cases atthe sole discretion of the Company and are subject to confirmation on the receipt of an Order. In anyevent the Company retains the right to withdraw credit facilities at any time prior to delivery ofGoods.5. PRICES & GST5.1 All prices must be as quoted or be in accordance with the Company's current price at the time of theOrder whichever is the higher. Verbal quotations are subject to written confirmation.5.2 All listed, published or quoted prices (unless otherwise expressly indicated) are exclusive of anyapplicable GST or any other applicable taxes, duties, costs and charges associated with the delivery ofthe Goods, and all such taxes, duties, costs and charges shall be included as an additional item to theinvoiced price.6. DELIVERY OF GOODS6.1 The Company will use its best endeavours to meet all quoted delivery or consignment dates but theCompany will not be liable to the Customer for any delay in delivery caused by any reasonwhatsoever.6.2 If the Customer wishes to use its own carrier, delivery of the Goods shall be ex-Company’s store andthe Customer shall pay all freight and insurance costs ex-Company’s store and shall indemnify theCompany against all actions, suits, proceedings, claims demands and all losses, expenses andliabilities, howsoever arising, for the transportation of the Goods delivered ex-Company’s store.6.3 In the event of any delay caused by the Customer or caused by industrial disputes, including strikesand lockouts, circumstances such as fire, war, mobilisation or any other cause beyond the reasonablecontrol of the Company, the Company, at its option, may extend the quoted delivery or consignmentdates or consign part of an Order or suspend consignment during that period of delay or may cancelthe order and the Customer shall not be relieved of the obligation to accept and pay for an Order, orany part of an Order, in accordance with clause 4, as a result of any such extensions, partialconsignments or suspensions.6.4 Delivery times made known to the Customer will be estimates only and the Company will not beliable for late delivery or non-delivery and under no circumstances will the Company be liable for anyloss, damage or delay occasioned to the Customer or its customers arising from late or non-deliveryof the Goods.6.5 The Company will be conclusively presumed to have delivered the Goods in accordance with theseterms and conditions if the Goods are delivered to the Consignment Address, whether or not theCompany obtains a receipt or signed delivery docket for the Goods from any person.6.6 If delivery cannot be affected, the Company may store the Goods or redeliver the Goods to theCustomer and the Customer must pay or indemnify the Company for all costs and expenses incurred.6.7 The Company will not be responsible for any loss or damage to Goods in transit. The Company willrender to the Customer such assistance as may be necessary to press claims on the Carriers providedthe Customer must have notified the Company and the Carrier in writing immediately of any loss ordamage is discovered on receipt of Goods and must lodge a claim on the Carrier within 3 days of thedate of receipt of the Goods.6.8 In the event of the Company agreeing to the return of the Goods or any part thereof by theCustomer, the Goods will be at the Customer’s risk until such time as the Goods reach the Company’spremises. Made to order Goods or Goods that are not a stock item will not be accepted for return.All expenses of return will be borne by the Customer and a 20% handling charge will be applied toany Goods accepted for return. Any Goods accepted for return must be returned to the place ofmanufacture or distribution. Where an order is cancelled after production of the ordered items orservices, a 20% cancellation fee may be charged.7. STORAGE OF GOODSIn the event that, after notification to the Customer that the Goods are ready for delivery, delay indelivery is caused by the Customer or caused by industrial disputes, including strikes and lockouts,circumstances such as fire, war, mobilisation or any other cause beyond the reasonable control of theCompany, the Company shall be entitled, at its option, to arrange suitable storage, whether at itspremises or elsewhere, and shall take reasonable steps to protect the Customer’s interest in theGoods. The Customer shall pay all costs of storage, insurance, demurrage, handling and othercharges associated with such storage.8. RISK AND SUPPLY8.1 All Goods sold to the Customer shall be at the Customer’s risk immediately upon delivery to orcollection by the Customer, the Customer’s nominee, the Customer’s carrier, except where Goods areheld for the Customer in accordance with clause 7, in which case risk shall pass to the Customer onthe date being seven (7) days from the date of notification to the Customer that the Goods are readyfor delivery.8.2 The Company reserves the right to: (a) withhold supply to the Customer where: (i) the Company hasinsufficient Goods to fulfil the Order, (ii) the Goods and/or services ordered have been discontinued,(iii) the Customer is in breach of any contract with the Company, or (iv) the Company otherwiseconsiders it appropriate for any other reason; (b) supply by instalments. The exercise of these rightsby the Company or delay in supply for any other reason does not entitle the Customer to terminateany contract with the Company or claim any loss or damage.8.3 The Customer shall provide at the delivery place free of charge all hoisting facilities of adequate sizeand capacity to lift the Goods without disassembling. Unless the Company otherwise agrees allGoods to be hoisted will not be disassembled in any way to suit the hoisting facilities provided. TheCustomer agrees to pay any additional costs thereby incurred which will be added to the contractprice.9. TITLE OF GOODS9.1 The property in the Goods will not pass to the Customer until payment in full on any accountwhatsoever has been received by the Company and the Customer’s cheque has been honouredwhether or not that account relates to the sale of the Goods. If the Customer fails to honour any ofthese terms and conditions of sale, the Company, without notice, will have the right to takepossession of the Goods which are the subject of this reservation of title, or trace the proceeds of thesale thereof, as the case may be, and to recover the full amount owing to the Company together withinterest and costs, if any.9.2 The Customer acknowledges that until property and ownership in the Goods passes to the Customerin accordance with sub-clause 9.1, the Customer is in possession of those Goods for and on behalf ofthe Company as a fiduciary bailee and agent and is only authorised to sell the Goods (in theCustomer’s own name and not as agent of the Company) in the ordinary course of the Customer’sbusiness.9.3 The Customer shall keep and safely store the Goods on its premises separately and in such mannerthat the Goods are readily identifiable as the property of the Company and shall display suchidentification as may from time to time be requested by the Company.9.4 If payment for any Goods is overdue, the Company is entitled, without prejudice to any of its otherrights and remedies, to repossess the Goods and to enter into any premises upon which the Goodsare stored (forcibly if necessary), without notice, for this purpose.FANSCATALOGUE9.5 Until such time as the Company receives payment in full for any Goods, if the Customer sells orreceives any payment from a customer or insurer in respect of the Goods, (a) the Customer must: (i)deposit the proceeds of any such sale or disposition and any insurance proceeds (or claim thereto) intoa separate and identifiable bank account which shall not be overdrawn; (ii) not mix such proceeds withany other moneys; and (iii) account to the Company for such proceeds, and (b) the Company will beentitled to trace all proceeds of sale of the Goods received by the Customer through the relevantaccount or any other account maintained by the Customer.9.6 If the Customer incorporates or mixes Goods supplied by the Company (the property in which has notpassed to the Customer in accordance with this clause 9) with other Goods not supplied by theCompany, the resulting product shall be the property of the Company. The rights of the Company inrespect of the resulting product shall be the same as those provided for in this clause 9 in respect ofGoods the property in which has not passed to the Customer, except that in exercising these rights theCompany shall account to the Customer (on a pro rata basis) for that part of the realised value of theresulting products which is attributable to: (a) the Goods not supplied by the Company; and (b) theCustomer’s cost of manufacture.9.7 Nothing in sub-clauses 9.1 to 9.6 inclusive shall affect the Company’s rights as an unpaid vendor. Thisclause 9 is not intended to create a charge over the Goods or over any book debts or proceeds of salein respect of the sale of the Goods. To the extent that any part of this clause is construed as creating acharge, the offending words shall be deleted.10. WARRANTY/LIABILITY10.1 The Company agrees and acknowledges that the Customer is entitled to all rights and remedies in respect ofthe Goods which the Customer has under the Trade Practices Act and similar State and Territory laws andwhich cannot be lawfully excluded, restricted or modified. These terms and conditions do not purport to,and do not have the effect of, excluding, restricting or modifying the exercise of any such right or remedy orthe liability of the Company in respect of any such right or remedy.10.1 The Company warrants that all Goods manufactured or supplied by it will be free of defects inworkmanship and materials for a period of 12 months from the date of commissioning but notexceeding eighteen (18) months from the date of invoice to the Customer provided that the Goodsare installed according to the requirements of AS/NZS3000:2007 Australian/New Zealand wiring rules.The Customer does not have any rights or remedies in respect of the Goods other than the rights andremedies expressly provided for in these terms and conditions or agreed and acknowledged by theCompany in these terms and conditions.10.2 Subject always to Clauses 10.1 and 10.4:(a) all conditions, warranties and guarantees other than those expressly provided for in these termsand conditions or agreed and acknowledged by the Company in these terms and conditions areexcluded to the fullest extent permitted by law; and(b) the Company will not be liable to the Customer for any loss caused (in whole or in part) by orarising out of any use of the Goods or any defect resulting from:(i) normal wear and tear or accident;(ii) misuse or other unsuitable or unauthorised use of the Goods or negligence or error instoring, maintaining or handling the Goods or equipment with or on which it operates.Reference will be made to appropriate standards issued by the Standards Associationof Australia and by the Company in determining the suitability of any use made of theGoods;(iii) incorrect installation or assembly of or failure to service the Goods or to otherwisefollow the Company’s service instructions including permitting repairs, installation,assembly or service by personnel not approved by the Company or replacements ofparts not manufactured or supplied by the Company.(iv) modifications or changes to the Goods without the Company’s prior writtenauthorisation; or(v) any other unauthorised act or fault by the Customer or a third party.10.4 Where the Customer is a consumer under the Trade Practices Act or similar State and Territory lawsand Goods supplied or services provided to the Customer are not of a kind ordinarily acquired forpersonal, domestic or household use or consumption, then unless the Customer establishes thatreliance on this provision would not be fair and reasonable, the liability for a breach of a condition orwarranty implied into these terms and conditions by the Trade Practices Act or by any similar State orTerritory laws (other than a condition implied by section 69 of the Trade Practices Act or by theequivalent provisions of any similar State or Territory laws) is limited to any one of the following asdetermined by the Company:(a) in the case of Goods supplied:(i) the replacement of the Goods or the supply or equivalent Goods;(ii) the repair of the Goods;(iii) the payment of the cost or replacement of the Goods or of acquiring equivalent Goods; or(iv) for the payment of the cost of having the Goods repaired.(b) in the case of services provided:(i) the supply of the services again; or(ii) the payment of the cost of having the services supplied again.10.5 The Customer acknowledges that neither the Company nor any person purporting to act on its behalfhas made any representation or given any promise or undertaking which is not expressly set out in theOrder or these terms and conditions whether as to the fitness of the Goods for any particular purposeor any other matter.11. SPECIFICATIONS AND INFORMATIONWhere the Company is not the manufacturer, the Company relies on the specifications and warrantiessupplied by the manufacturer.12. INTELLECTUAL PROPERTY12.1 The Customer acknowledges that all rights in respect of patents, copyrights, design rights, trade marksor other industrial or intellectual property rights connected with the Goods shall not pass to theCustomer. The Customer shall indemnify the Company against any and all liabilities, claims and costsincurred by or made against the Company as a direct or indirect result of carrying out of any workrequired to be done on or to the Goods in accordance with the requirements or specifications of theCustomer involving any infringement or alleged infringement of any rights of any third party.12.2 If any action, suit, proceeding, claim or demand is brought or made alleging that the sale, use or anyother dealing with the Goods infringes the trade mark, trade name, patent, copyright, registereddesign or any other intellectual or industrial property rights of third parties, the Customer shallforthwith notify the Company thereof and give every assistance to the Company in connectiontherewith as the Company may reasonably require and shall not itself handle, deal with or compromiseany such action, suit, proceedings, claim or demand except with the prior written consent of theCompany.13. CANCELLATIONNo Order may be cancelled except with the Company’s consent in writing and on terms which willindemnify the Company against all losses.14. TERMINATION14.1 The Company will be entitled to terminate any Order with the Customer or revoke any credit termsgranted if the Customer fails to punctually pay moneys due to the Company, has any security enforcedagainst it, commits an act of bankruptcy or, being a company, passes a resolution for winding up(except for the purposes of reconstruction) or a court makes an order winding up the Customer or ifthe Company notifies the Customer that it is of the view that the Customer or any Related BodyCorporate of the Customer is in financial difficulties.14.2 Upon the occurrence of a termination event referred to in Clause 14.1, the Company reserves the rightto cancel an Order with the Customer (to the extent that the Order remains unperformed) in whole orin part without any liability attaching to the Company, stop any Goods in transit and dispose of theGoods produced for or supplied to the Customer, to a third party and all moneys owing to theCompany in respect of any Order will be immediately payable by the Customer.14.3 Termination is without prejudice to any right or obligation, which may have accrued prior totermination.15. CLAIMS AND DISPUTESAny claims as to quality or quantity of Goods supplied must be made within 7 days of delivery of theGoods to the Customer. In the event of a dispute between the Customer and the Company relating toeither the quality, quantity or delivery of the Goods, the Customer agrees to pay the Company all suchamounts owing to the Company by the Customer until such time as the dispute is resolved.16. FORCE MAJEURE16.1 The Company will not be liable for any loss incurred as a result of delay or failure to meet an acceptedOrder or to observe any of these terms and conditions (other than an obligation to pay money) due toan event of force majeure, being any cause or circumstance beyond the Company's control, includingbut not limited to any failure or delay in performance caused by any strikes, lockouts, labour disputes,fires, acts of God or public enemy, malicious or accidental damage, delays in transport, breakdowns inmachinery or restrictions or prohibitions by any government or any or any semi-governmentauthorities or embargoes.16.2 During the continuance of an event of force majeure affecting the Company, its obligations hereunderwill be suspended and will resume as soon as possible after the cause or circumstance has ceased tohave effect.17. SEVERABILITYIf any of these terms or conditions infringes any law in Australia they must be read down so that theydo not infringe that law, otherwise such parts will be deemed void and severable.18. GOVERNING LAWThese terms and conditions are governed by and must be construed in accordance with the laws ofVictoria and the Customer hereby agrees to submit to the exclusive jurisdiction of the courts of Victoriaand any court of appeal there from.19. MISTAKEAny mistake on any quotation, Order, invoice, delivery document or other document issued by theCompany in relation to the Goods shall not be binding on the Company and the Company may in itsdiscretion issue such amended document as is required to rectify such mistake. The Customer shallcomply with the Company’s amended document.352 © <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


Terms & Conditions - New Zealand1. GENERALIn these terms and conditions (unless the context requires otherwise):“Carrier” means a Carrier nominated by the Company to take delivery of the Goods;“CGA” means the Consumer Guarantees Act 1991;“Company” means <strong>Fans</strong> <strong>Direct</strong> Pty Ltd“Consignment Address” means the delivery address of the Customer stated in an Order or otherwise agreed by theCompany;“Customer” means any person who enters into a contract with the Company for the purchase of Goods andincludes:(i) any successors or permitted assigns; and(ii) if the Customer consists of more than one person both of them jointly and eachof them severally;“Goods” means any goods supplied or to be supplied by the Company as specified in an Orderaccepted by the Company.“GST” means the goods and services tax chargeable under the Goods and Services Tax Act, 1985 (as amended) (“GST Act” )“Order” means a Customer order placed with the Company for the supply of Goods;“Related Company” means a related company as that term is defined in the Companies Act, 1993.2. QUOTATIONSA quotation by the Company shall be an invitation to treat, and shall not constitute an offer. Any modification to aquotation will be effective only if it is expressed in writing and signed by a duly authorised officer of the Company.3. CONTRACT FOR SALE OF GOODS3.1 Each Order constitutes an offer by the Customer to acquire the Goods subject strictly to these terms and conditionsand to the exclusion of any other terms and conditions asserted by the Customer. A contract will be made betweenthe Company and the Customer for the supply of Goods only when an Order is accepted by the Company in writing,orally or by conduct.3.2 The Company may at any time refuse to extend credit to the Customer and need not give any reason for its refusal.3.3 These terms and conditions supersede all previous terms and conditions and may only be varied if authorised inwriting on behalf of the Company.4. PAYMENT4.1 The price for the Goods must be paid on delivery of the Goods to the Customer unless other terms of payment areexpressly stated in writing and signed by the Company.4.2 In the event the Customer fails to make payment to the Company when payment falls due, the Company shall havethe right, without prejudice to any other right or remedy the Company may be entitled, to charge interest on anyoverdue invoice at a rate of 1.5% per month calculated and payable daily and compounded from the due date untilthe invoice is paid in full. Interest shall accrue after as well as before judgment and shall be payable on demand.The Customer also must pay all costs and expenses (including legal costs on a solicitor and own client basis), whichmay be incurred by the Company in the recovery of the overdue amounts. Any payment by the Customer shall becredited first against any interest so accrued and the balance, if any, shall be applied in reduction of the outstandingbalance of the price.4.3 Notwithstanding that the Customer may be granted time to pay for the Goods and/or services or credit facilities areprovided, the Customer must, in the event the Goods are sold and the proceeds of sale received, where applicable,comply with clause 9.4.4 The extension of credit facilities and the terms upon which such credit is provided are, in all cases at the solediscretion of the Company and are subject to confirmation on the receipt of an Order. In any event the Companyretains the right to withdraw credit facilities at any time prior to delivery of Goods.5. PRICES & GST5.1 All prices must be as quoted or be in accordance with the Company's current price at the time of the Orderwhichever is the higher. Verbal quotations are subject to written confirmation.5.2 All listed, published or quoted prices (unless otherwise expressly indicated) are exclusive of any applicable GST orany other applicable taxes, duties, costs and charges associated with the delivery of the Goods, and all such taxes,duties, costs and charges shall be included as an additional item to the invoiced price.6. DELIVERY OF GOODS6.1 The Company will use its best endeavours to meet all quoted delivery or consignment dates but the Company willnot be liable to the Customer for any delay in delivery caused by any reason whatsoever.6.2 If the Customer wishes to use its own carrier, delivery of the Goods shall be ex-Company’s store and the Customershall pay all freight and insurance costs ex-Company’s store and shall indemnify the Company against all actions,suits, proceedings, claims demands and all losses, expenses and liabilities, howsoever arising, for the transportationof the Goods delivered ex-Company’s store.6.3 In the event of any delay caused by the Customer or caused by industrial disputes, including strikes and lockouts,circumstances such as fire, war, mobilisation or any cause beyond the reasonable control of the Company, theCompany, at its option, may extend the quoted delivery or consignment dates or consign part of an Order orsuspend consignment during that period of delay or may cancel the order and the Customer shall not be relieved ofthe obligation to accept and pay for an Order, or any part of an Order, in accordance with clause 4, as a result of anysuch extensions, partial consignments or suspensions.6.4 Delivery times made known to the Customer will be estimates only and the Company will not be liable for latedelivery or non-delivery and under no circumstances will the Company be liable for any loss, damage or delayoccasioned to the Customer or its customers arising from late or non-delivery of the Goods.6.5 The Company will be conclusively presumed to have delivered the Goods in accordance with these terms andconditions if the Goods are delivered to the Consignment Address, whether or not the Company obtains a receipt orsigned delivery docket for the Goods from any person.6.6 If delivery cannot be effected, the Company may store the Goods or redeliver the Goods to the Customer and theCustomer must pay or indemnify the Company for all costs and expenses incurred.6.7 The Company will not be responsible for any loss or damage to Goods in transit. The Company will render to theCustomer such assistance as may be necessary to press claims on the Carriers provided the Customer must havenotified the Company and the Carrier in writing immediately if any loss or damage is discovered on receipt of Goodsand must lodge a claim on the Carrier within 3 days of the date of receipt of the Goods.6.8 In the event of the Company agreeing to the return of the Goods or any part thereof by the Customer, the Goods willbe at the Customer’s risk until such time as the Goods reach the Company’s premises. Made to order Goods orGoods that are not a stock item will not be accepted for return. All expenses of return will be borne by theCustomer and a 20% handling charge will be applied to any Goods accepted for return. Any Goods accepted forreturn must be returned to the place of manufacture or distribution. Where an order is cancelled after productionof the ordered items or services, a 20% cancellation fee may be charged.7. STORAGE OF GOODSIn the event that, after notification to the Customer that the Goods are ready for delivery, delay in delivery is causedby the Customer or caused by industrial disputes, including strikes and lockouts, circumstances such as fire, war,mobilisation or any other cause beyond the reasonable control of the Company, the Company shall be entitled, at itsoption, to arrange suitable storage, whether at its premises or elsewhere, and shall take reasonable steps to protectthe Customer’s interest in the Goods. The Customer shall pay all costs of storage, insurance, demurrage, handlingand other charges associated with such storage.8. RISK AND SUPPLY8.1 All Goods sold to the Customer shall be at the Customer’s risk immediately upon delivery to or collection by theCustomer, the Customer’s nominee or the Customer’s carrier, except where Goods are held for the Customer inaccordance with clause 7, in which case risk shall pass to the Customer on the date being seven (7) days from thedate of notification to the Customer that the Goods are ready for delivery.8.2 The Company reserves the right to: (a) withhold supply to the Customer where: (i) the Company has insufficientGoods to fulfil the Order, (ii) the Goods and/or services ordered have been discontinued, (iii) the Customer is inbreach of any contract with the Company, or (iv) the Company otherwise considers it appropriate for any otherreason; (b) supply by instalments. The exercise of these rights by the Company or delay in supply for any otherreason does not entitle the Customer to terminate any contract with the Company or claim any loss or damage.8.3 The Customer shall provide at the Consignment Address free of charge all hoisting facilities of adequate size andcapacity to lift the Goods without disassembling. Unless the Company otherwise agrees all Goods to be hoisted willnot be disassembled in any way to suit the hoisting facilities provided. The Customer agrees to pay any additionalcosts thereby incurred which will be added to the contract price.9. TITLE TO GOODS9.1 The property in the Goods will not pass to the Customer until payment in full on any account whatsoever has beenreceived by the Company and the Customer’s cheque has been honoured whether or not that account relates to thesale of the Goods. If the Customer fails to honour any of these terms and conditions of sale, the Company, withoutnotice, will have the right to take possession of the Goods which are the subject of this reservation of title, or tracethe proceeds of the sale thereof, as the case may be, and to recover the full amount owing to the Company togetherwith interest and costs, if any.9.2 The Customer acknowledges that until property and ownership in the Goods passes to the Customer in accordancewith sub-clause 9.1, the Customer is in possession of those Goods for and on behalf of the Company as a fiduciarybailee and agent and is only authorised to sell the Goods (in the Customer’s own name and not as agent of theCompany) in the ordinary course of the Customer’s business.9.3 The Customer shall keep and safely store the Goods on its premises separately and in such manner that the Goodsare readily identifiable as the property of the Company and shall display such identification as may from time to timebe requested by the Company.9.4 If payment for any Goods is overdue, the Company is entitled, without prejudice to any of its other rights andremedies, to repossess the Goods and to enter into any premises upon which the Goods are stored (forcibly ifnecessary), without notice, for this purpose.9.5 Until such time as the Company receives payment in full for any Goods, if the Customer sells or receives anypayment from a customer or insurer in respect of the Goods, (a) the Customer must: (i) deposit the proceeds ofany such sale or disposition and any insurance proceeds (or claim thereto) into a separate and identifiable bankaccount which shall not be overdrawn; (ii) not mix such proceeds with any other moneys; and (iii) account to theCompany for such proceeds, and (b) the Company will be entitled to trace all proceeds of sale of the Goodsreceived by the Customer through the relevant account or any other account maintained by the Customer.9.6 If the Customer incorporates or mixes Goods (the property in which has not passed to the Customer inaccordance with this clause 9) with other goods not supplied by the Company, the resulting product shall be theproperty of the Company. The rights of the Company in respect of the resulting product shall be the same asthose provided for in this clause 9 in respect of Goods the property in which has not passed to the Customer,except that in exercising these rights the Company shall account to the Customer (on a pro rata basis) for thatpart of the realised value of the resulting products which is attributable to: (a) the goods not supplied by theCompany; and (b) the Customer’s cost of manufacture.9.7 The Customer grants the Company a security interest in the Goods and in the proceeds of the Goods in theevent that they are sold or disposed of. The Company’s security interest shall serve as security for all amountsowing by the Customer at any time from any cause. The Customer shall provide the Company with suchinformation as may be necessary for the registration of its security interest in terms of the Personal PropertySecurities Act 1999. The Customer agrees that the Company shall not be obliged to send the Customer a copy ofany financing statement which it may register on the Personal Property Securities Register.10. WARRANTY/LIABILITY10.1 These terms and conditions do not purport to, and do not have the effect of, excluding, restricting or modifyingthe exercise of any right or remedy which the Customer may have under the CGA, to the extent that it isapplicable, and subject to Clause 10.6.10.2 The Company warrants that all Goods manufactured or supplied by it will be free of defects in workmanshipand materials for a period of 12 months from the date of commissioning but not exceeding eighteen (18)months from the date of invoice to the Customer provided that the Goods are installed according to therequirements of AS/NZS3000:2007 Australian/New Zealand wiring rules. The Customer does not have anyrights or remedies in respect of the Goods other than the rights and remedies expressly provided for in theseterms and conditions or agreed and acknowledged by the Company in these terms and conditions.10.3 Subject always to Clause 10.1:(a) all conditions, warranties and guarantees other than those expressly provided for in these terms andconditions or agreed and acknowledged by the Company in these terms and conditions are excluded tothe fullest extent permitted by law; and(b) the Company will not be liable to the Customer for any loss caused (in whole or in part) by or arising outof any use of the Goods or any defect resulting from:(i) normal wear and tear or accident;(ii) misuse or other unsuitable or unauthorised use of the Goods or negligence or error in storing,maintaining or handling the Goods or equipment with or on which it operates. Reference will bemade to appropriate standards issued by Standards New Zealand (or its successor) and by theCompany in determining the suitability of any use made of the Goods;(iii) incorrect installation or assembly of or failure to service the Goods or to otherwise follow theCompany’s service instructions including permitting repairs, installation, assembly or service bypersonnel not approved by the Company or replacements of parts not manufactured or suppliedby the Company.(iv) modifications or changes to the Goods without the Company’s prior written authorisation; or(v) any other unauthorised act or fault by the Customer or a third party.10.4 Subject to Clause 10.1, our liability under any warranty given in respect of the Goods is limited to any one of thefollowing as determined by the Company:(a) the replacement of the Goods or the supply or equivalent Goods;(b) the repair of the Goods;(c) the payment of the cost or replacement of the Goods or of acquiring equivalent Goods; or(d) for the payment of the cost of having the Goods repaired.10.5 The Customer acknowledges that neither the Company nor any person purporting to act on its behalf has madeany representation or given any promise or undertaking which is not expressly set out in the Order or theseterms and conditions whether as to the fitness of the Goods for any particular purpose or any other matter.10.6 Where the Customer acquires the Goods for the purposes of its business, the CGA shall not apply. In the case ofresale by the Customer, the Customer shall: (a) inform its customers in writing that the Company does notundertake to repair or replace the Goods; (b) contract out of the CGA to the extent allowed by law; (c) not giveany warranties that exceed the warranties given by the Company; (d) indemnify the Company in respect of anyclaims arising from the manner in which the Customer installed or dealt with the Goods for its customer.11. SPECIFICATIONS AND INFORMATIONWhere the Company is not the manufacturer, the Company relies on the specifications and warranties suppliedby the manufacturer.12. INTELLECTUAL PROPERTY12.1 The Customer acknowledges that all rights in respect of patents, copyrights, design rights, trade marks or otherindustrial or intellectual property rights connected with the Goods shall not pass to the Customer. TheCustomer shall indemnify the Company against any and all liabilities, claims and costs incurred by or madeagainst the Company as a direct or indirect result of carrying out of any work required to be done on or to theGoods in accordance with the requirements or specifications of the Customer involving any infringement oralleged infringement of any rights of any third party.12.2 If any action, suit, proceeding, claim or demand is brought or made alleging that the sale, use or any otherdealing with the Goods infringes the trade mark, trade name, patent, copyright, registered design or any otherintellectual or industrial property rights of third parties, the Customer shall forthwith notify the Companythereof and give every assistance to the Company in connection therewith as the Company may reasonablyrequire and shall not itself handle, deal with or compromise any such action, suit, proceedings, claim or demandexcept with the prior written consent of the Company.13. CANCELLATIONNo Order may be cancelled except with the Company’s consent in writing and on terms which will indemnify theCompany against all losses.14. TERMINATION14.1 The Company will be entitled to terminate any Order with the Customer or revoke any credit terms granted ifthe Customer fails to punctually pay moneys due to the Company, has any security enforced against it, commitsan act of bankruptcy or, being a company, passes a resolution for winding up (except for the purposes ofreconstruction) or a court makes an order winding up the Customer or if the Company notifies the Customerthat it is of the view that the Customer or any Related Company of the Customer is in financial difficulties.14.2 Upon the occurrence of a termination event referred to in Clause 14.1, the Company reserves the right to cancelan Order with the Customer (to the extent that the Order remains unperformed) in whole or in part without anyliability attaching to the Company, stop any Goods in transit and dispose of the Goods produced for or suppliedto the Customer, to a third party and all moneys owing to the Company in respect of any Order will beimmediately payable by the Customer.14.3 Termination is without prejudice to any right or obligation, which may have accrued prior to termination.15. CLAIMS AND DISPUTESAny claims as to quality or quantity of Goods supplied must be made within 7 days of delivery of the Goods tothe Customer. In the event of a dispute between the Customer and the Company relating to either the quality,quantity or delivery of the Goods, the Customer agrees to pay the Company all such amounts owing to theCompany by the Customer until such time as the dispute is resolved.16. FORCE MAJEURE16.1 The Company will not be liable for any loss incurred as a result of delay or failure to meet an accepted Order orto observe any of these terms and conditions (other than an obligation to pay money) due to an event of forcemajeure, being any cause or circumstance beyond the Company's control, including but not limited to any failureor delay in performance caused by any strikes, lockouts, labour disputes, fires, acts of God or public enemy,malicious or accidental damage, delays in transport, breakdowns in machinery or restrictions or prohibitions byany government or any or any semi-government authorities or embargoes.16.2 During the continuance of an event of force majeure affecting the Company, its obligations hereunder will besuspended and will resume as soon as possible after the cause or circumstance has ceased to have effect.17. SEVERABILITY AND NON-WAIVER17.1 If any of these terms or conditions infringes any law in New Zealand they must be read down so that they donot infringe that law, otherwise such parts will be deemed void and severable.17.2 No waiver of any of these terms and conditions by the Company shall be binding unless it is in writing. Failureby the Company to exercise a right is not a waiver of that right.18. GOVERNING LAWThese terms and conditions are governed by and must be construed in accordance with the laws of New Zealandand the Customer hereby agrees to submit to the exclusive jurisdiction of the courts of New Zealand and anycourt of appeal there from.19. MISTAKEAny mistake on any quotation, Order, invoice, delivery document or other document issued by the Company inrelation to the Goods shall not be binding on the Company and the Company may in its discretion issue suchamended document as is required to rectify such mistake. The Customer shall comply with the Company’samended document.© <strong>Fans</strong> <strong>Direct</strong> 2011 www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326 353