13.07.2015 Views

Catalogue For Print Version 21 FINAL - Fans Direct

Catalogue For Print Version 21 FINAL - Fans Direct

Catalogue For Print Version 21 FINAL - Fans Direct

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

PRODUCT DATAVD, DQ/DS Roof Mounted Adjustable Pitch AxialproductVD, DQ, DS - Roof Mounted Adjustable Pitch Axial Flowdimensions mm400 - 1120poles & duty2 - 8 / up to 22,000 L/sapplicationA highly competitive general purpose range for input or extract ventilation.Smoke spill available in VD models.VD Vertical Discharge ExhaustDQ Down Discharge AxialDS Supply Air AxialSpecificationsBases for all models are of galvanised steel construction. Caps, wind bandsand shutter flaps are manufactured from UV stabilised polymer, fibreglass orgalvanised steel. The flap mounting mechanism is designed to prevent waterleaking into the fan. Special materials and finishes are available for hazardousenvironments and special circumstances. Available in optional Colorbondcolours.TestingUnits comply with AS4429 and AS1668 pt1 for Smoke Spill applications (VDOnly). Rated fan performance has been determined by testing to ISO 5801Pt1 (1997) and BS848 Pt1 (1998). Fan sound data has been determined bytesting to AMCA 300.ImpellersAerofoil adjustable pitch impellers are available in a range of materials,including pressure die cast aluminium, injection moulded glass reinforcedpolypropylene (GRP) and nylon. Impellers are balanced to ISO1940 GradeG6.3.MotorsMotors are of TEFC design. Motor enclosure features IP54 protection. Motorwindings incorporate class ‘ F’ insulation as standard although class ‘ H’ isreadily available. Motor bearings are sealed for life and maintenance free.Auto-reset thermal contacts are generally provided, either integrally wired orterminated at wiring connection bar.Wiring diagrams and latest dataRefer to the latest product datasheet for individual model wiring instructions,data and specifications. Datasheets are available from our electronicselection software <strong>Fans</strong>Select downloadable at www.fansdirect.com.auIt is the responsibility of the user to connect the thermal contacts whereprovided to protect the motor. It is a condition of our warranty that allequipment supplied is installed according to the requirements ofAS/NZS3000:2007 Australian/New Zealand wiring rules.VDSize A B C D E F kg400 530 440 480 315 50 183 30500 645 545 556 445 80 253 40560 715 615 626 445 80 253 50630 795 695 686 511 80 286 60710 840 740 776 515 80 286 70800 960 810 816 635 80 323 801000 1160 1010 1034 635 80 223 130DQ / DSSize A B C D E F kg400 530 440 710 391 50 183 30500 645 545 820 466 80 253 40560 715 615 820 466 80 253 50630 795 695 960 545 80 286 601000 840 740 1234 585 80 286 701000 960 810 1234 670 80 323 801120 1160 1010 1410 710 80 323 130© <strong>Fans</strong> <strong>Direct</strong> www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


PRODUCT DATAVD Envelopes By Ø and Motor SpeedPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performanceenvelopes have been grouped by motor speed for each fan model’s available diameter. Note that scales for all charts arelinear. We strongly recommend that these curves be used as a guide only. <strong>For</strong> detailed performance capability refer to our fanselection software <strong>Fans</strong>Select available for free download at www.fansdirect.com.auVD Vertical Discharge Adjustable Adjustible Pitch - 400mm5004002 PoleVD Vertical Discharge ExhaustPressure (Pa)3002001004 Pole6 Pole8 Pole00 0.5 1 1.5 2 2.5 3 3.5Air Flow (m3/s)Suggested SpecificationAdjustable Pitch Axial Flow Exhaust/Supply type fans shall be of the VD,DQ/DS Series manufactured by <strong>Fans</strong><strong>Direct</strong> Pty Ltd.Axial Flow impellers shall be driven byTEFC motors with sealed for lifebearings. Fan bases, and caps shall beweather proof and fabricated fromUV resistant ABS polymer, fibreglassand corrosion protected steel.All fans shall be fully tested inaccordance with the requirements ofISO 5801 Pt 1 (1997) and BS 848 Pt1(1998) for air flow and AMCA 300 forsound. VD units shall comply with therequirements of AS4429 and AS1668 pt1 for smoke spill applicationsPressure (Pa)VD Vertical Discharge Adjustable Adjustible Pitch - 500mm6005002 Pole4003004 Pole2006 Pole1008 Pole00 1 2 3 4 5 6Air Flow (m3/s)VD VD Vertical Discharge Adjustable Adjustible Pitch - 560mm8007002 Pole600AncillariesPressure (Pa)5004003002004 Pole6 Pole1008 Pole00 1 2 3 4 5 6 7 8Air Flow (m3/s)800VD Vertical Discharge Adjustable Adjustible Pitch - 630mmPressure (Pa)70060050040030020010002 Pole4 Pole6 Pole8 Pole0 2 4 6 8 10 12Air Flow (m3/s)© <strong>Fans</strong> <strong>Direct</strong> www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


PRODUCT DATAVD Envelopes By Ø and Motor SpeedPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performanceenvelopes have been grouped by motor speed for each fan model’s available diameter. Note that scales for all charts arelinear. We strongly recommend that these curves be used as a guide only. <strong>For</strong> detailed performance capability refer to our fanselection software <strong>Fans</strong>Select available for free download at www.fansdirect.com.au350VD VD Vertical Discharge Adjustable Adjustible Pitch - 710mm3002504 PoleVD Vertical Discharge ExhaustPressure (Pa)200150100506 Pole8 Pole00 2 4 6 8 10Air Flow (m3/s)Pressure (Pa)VD Vertical Discharge Adjustable Adjustible Pitch - 800mm4504004 Pole3503002502001506 Pole1008 Pole5000 2 4 6 8 10 12 14Air Flow (m3/s)Pressure (Pa)VD VD Vertical Discharge Adjustable Adjustible Pitch - 1000mm5004504004 Pole3503002502001506 Pole1008 Pole5000 5 10 15 20 25 30Air Flow (m3/s)© <strong>Fans</strong> <strong>Direct</strong> www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326


PRODUCT DATADQ/DS Envelopes By Ø and Motor SpeedPerformance Envelope CurvesThe performance curves on this page offer a guide to the duties covered within the model range described. Performanceenvelopes have been grouped by motor speed for each fan model’s available diameter. Note that scales for all charts arelinear. We strongly recommend that these curves be used as a guide only. <strong>For</strong> detailed performance capability refer to our fanselection software <strong>Fans</strong>Select available for free download at www.fansdirect.com.auDQ/DS DQ/DS Adjustable Axial Pitch - 400mm Axial - 400mm3503002 Pole250DQ Down Discharge AxialDS Supply Air AxialPressure (Pa)2001501005004 Pole6 Pole8 Pole0 0.5 1 1.5 2 2.5 3 3.5Air Flow (m3/s)DQ/DS DQ/DS Adjustable Axial Pitch - 500mm Axial - 500mm4003503002 PolePressure (Pa)2502001504 Pole1006 Pole508 Pole00 1 2 3 4 5Air Flow (m3/s)DQ/DS DQ/DS Adjustable Axial Pitch - 560mm Axial - 560mm6005002 PolePressure (Pa)4003002001004 Pole6 Pole8 Pole00 1 2 3 4 5 6 7Air Flow (m3/s)DQ/DS DQ/DS Adjustable Axial Pitch - 630mm Axial - 630mm4003503002 PolePressure (Pa)2502001504 Pole1006 Pole508 Pole00 2 4 6 8 10Air Flow (m3/s)© <strong>Fans</strong> <strong>Direct</strong> www.fansdirect.com.au Tel. Australia 1300 733 833 NZ 0800 100 326

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!