12.07.2015 Views

MSDS - Lucron Elitech Benelux

MSDS - Lucron Elitech Benelux

MSDS - Lucron Elitech Benelux

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>MSDS</strong>-IM URICHROM II Last updated : 14/04/09 Page : 2/4Concentrations (% weight/weight)SymbolsLimitsUsedName Components/Substances CAS N° of danger Toxicity Ecotoxicity [Conc.]URICHROM II Peptones NA Xi 20 not evaluated < 20Trizma base 77-86-1 Xi 20 not evaluated < 24. First aid measuresAs a general rule, in any doubts, accident, feeling of sickness, or if symptoms appear or persist, always seekmedical advice and show this document.A) Non-seeded reagentNever feed an unconscious person.In case of contact with eyes, verify if the victim wears lenses and if so, remove them.In case of inhalation:Possible dustMove to fresh air.Make blow the nose.In case of breathing difficulties, seek medical attention.In case of contact with skinIn case of contact with eyesRemains or possible dustImmediately, wash off with soap and plenty of water.Immediately, rinse opened eyes with plenty of water for at least 15 minutes.Seek medical advice and show this documentIf swallowedRinse mouth with water, then drink plenty of water (only if the person is conscious).Call a Poison Control Center and seek medical advice.Do not induce vomiting, unless in case of medical advice.Symptoms:Irritation of the eyes, the respiratory system and the skin.First-aid worker equipment:Lab coat, glasses, glovesAggravating circumstances:Unknown at the present timeB) Seeded reagentPrevious first aid measures, as well as additionnal precautions associated with the use of microbial cultures,should be taken in account.Contamination can occur via aerosol, projection or spillageIn case of contact with skinUse a disinfectantIn case of inhalation, ingestion or contact with the eyesidem A, seek medical advice.5. Fire-fighting measuresSuitable extinguishing mediaSpray water, powder or dry iceRisks associated to the product**If kits are stored in large quantity :Burning of plastic plates can produce toxic fumes.Equipment requiredMask for respiratory and eye protection.Special protective equipment and gloves for skin protection.*If the agar plate is seeded Inform help about localization and cautions to be taken.6. Accidental release measuresPersonal protection : Gloves Mask Lab coatDelimit the area : Limit the spreading by using absorbent materialIf agar is seeded : Prohibit admittance in the contaminated area Avoid draughtsDecontaminate the area with a disinfectantCollecting :Use of absorbent materialCleaning :Water or disinfectant (if agar seeded)Waste disposal : Specific container7. Handling and storageHandling :Usual precautionsStorage : In their original packaging, at 2-8°C. In a specific and safe storage room.Specific use :By authorized personnel, according to Instructions For Use and Good Laboratory Practices.


<strong>MSDS</strong>-IM URICHROM II Last updated : 14/04/09 Page : 3/48. Exposure controls / personal protectionIn general, additional personal protection is not required.Exposure limit value :NAExposure control :Not requiredFacility protective equipment : Shower Eyewash fountainPersonal protective equipment : Lab coat Glasses GlovesChemical resistant glovesSafety glassesHygienic measuresTake off immediately all contaminated clothing. Avoid contact with skin. Wash hands after use.When using the reagents, do not eat or drink.Protection of the environmentDo not empty the reagents, used or not used, into drains or in household refuse (cf. §13).9. Physical and chemical propertiesDescription :Colour:Odour :Flash point :Water solubility (20°C):pH:Gel / TranslucentColourlessNoneNANA710. Stability and reactivityStable under normal conditions of use and storage (2-8°C) until the expiry date indicated on the box.11. Toxicological informationThe toxicity of the preparation has been determined using the classification rules in Directive EC (Concentration limits /addition of substances)12. Ecological informationThe ecological effect have not yet been thoroughly investigated.13. Disposal considerationsDispose of material in accordance with the hygiene rules and current regulations for this kind of product in the country of use.14. Transport informationThe reagents of the kit should be transported in their original packaging, hermetically sealed.The symbol "Store at 2-8°C" only concerns long term storage (warehouse or final user's lab) and excludes the conditions oftransport and use.Transport typeLegislation typeRoad / RailADR / RIDexemptSeaIMDGexemptAirIATAexempt15. Regulatory informationDevice registered according to :Classification and labelling :Symbol of danger:Risk phrases :Safety phrases :DIRECTIVE 98/79/EC on in vitro diagnostic medical devicesDIRECTIVE 1999/45/ECNoneNoneNone


<strong>MSDS</strong>-IM URICHROM II Last updated : 14/04/09 Page : 4/416. Other informationReason of modification: Change § 1,2 and 3IndexR phraseS phraseNoneNoneThis product is exclusively intended for in vitro diagnostic useThe company does not assume any responsibility in case of inappropriate useThis Material Safety Data Sheet is a complement to the Instructions For Use (IFU) but does not replace it. The informationcontained herein was compiled from data presented in various technical sources ; it is believed to be accurate andrepresents our best knowledge at the present time.The company makes no warranty and does not assume any liability for the use of this information, or in case of inappropriatehandling of this product. Users should strictly respect the IFU. It is the user’s responsibility to determine the suitability of thisinformation and to adopt necessary safety precautions.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!