13.07.2015 Views

MSDS - Lucron Elitech Benelux

MSDS - Lucron Elitech Benelux

MSDS - Lucron Elitech Benelux

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MSDS</strong>-IM MYCOFAST Evolution 2 Last updated : 14/04/09 Page : 3/6Uu 10 4 Antibiotic agent Xi 20 not evaluated < 0,5Uu ≥ 10 5 HCl N 7647-01-0 C 10 not evaluated > 10Corrosive R phrases 34/37 S phrases 26/45D Doxycyclin 24390-14-5 Xn 25 not evaluated > 80Harmful R phrases 22/36/37/38 S phrases 26ROX Roxithromycin 80214-83-1 Xn 25 not evaluated > 80Harmful R phrases 22 S phrases 22/46/64OFX NaCl 7647-14-5 Xi 20 not evaluated > 20HCl N 7647-01-0 C 10 not evaluated > 10Ofloxacin 82419-36-1 None not evaluatedCorrosive R phrases 34/37 S phrases 22/26/45L Lincomycin 859-18-7 Xi 20 not evaluated > 80Irritant R phrases 36/37/38S phrases26SXT Sulfamethoxazole 723-46-6 Xi 1 not evaluated > 20Trimethoprim 738-70-5 NoneIrritant R phrases 36/37/38/43 S phrases 26E Erythromycin 114-07-8 None not evaluated≥ 10 4 Antibiotic agent None not evaluated4. First aid measuresAs a general rule, in any doubts, accident, feeling of sickness, or if symptoms appear or persist, always seekmedical advice and show this document.A) Non-seeded reagentRemove the person from the contaminated area.Never feed an unconscious person.In case of contact with eyes, verify if the victim wears lenses and if so, remove them.In case of accident by inhalationVials UMMt UMMlyo S. MhMove to fresh air.Tray Possible dust or projectionsMake blow the noseIn case of breathing difficulties, seek medical attention.In case of contact with skinVials UMMt UMMlyo S. MhImmediately, wash off with soap and plenty of water.Tray Possible dust or projectionsIn case of contact with eyesVials UMMt UMMlyo S. MhTrayPossible dust or projectionsIf swallowedVials UMMt UMMlyo S. MhImmediately, rinse opened eyes with plenty of waterfor at least 15 minutes.Seek medical advice and show this documentRinse mouth and drink plenty of water


<strong>MSDS</strong>-IM MYCOFAST Evolution 2 Last updated : 14/04/09 Page : 4/6Tray Possible dust or projectionsRinse mouth with water, then drink plenty of water (only if the person is conscious).Call a Poison Control Centre and seek medical advice.Do not induce vomiting, unless in case of medical advice.Symptoms:Irritation of the eyes, the respiratory system and the skin.First-aid worker equipment:Lab coat, glasses, glovesAggravating circumstances:Not known at the present timeB) Seeded reagentPrevious first aid measures, as well as additionnal precautions associated with the use of microbial cultures shouldbe taken in account.Reagents concerned : UMMt UMMt+UMMlyo WellsContamination can occur via aerosol, projection or spillageIn case of contact with skinAlso use a disinfectantIn case of inhalation, ingestion or contact with the eyesAfter, seek medical advice.5. Fire-fighting measuresSuitable extinguishing mediaRisks associated to the product**If kits are stored in large quantity :Equipment required*If the reagents are seeded :Spray water, powder or dry iceBurning of the plastic trays can produce toxic fumes.Mask for respiratory and eyes protection.Special protective equipment and gloves for skin protection.Inform help about localization and cautions to be taken.6. Accidental release measuresPersonal protection : Gloves Mask Lab coatDelimit the area : Limit the spreading by using absorbent materialIf reagents are seeded : Prohibit admittance in the contaminated areaDecontaminate the area with a disinfectantCollecting :Use of absorbent materialCleaning :Water or disinfectant (if reagents seeded)Waste disposal: Specific containerAvoid draughts7. Handling and storageHandlingUsual precautions to prevent vial breakages or tray sachet deterioration.Storage In their original packaging, at 2-8°C. In a specific and safe storage room.Specific useBy authorized personnel, according to Instructions For Use and Good Laboratory Practices.8. Exposure controls/personal protectionIn general, additional personal protection is not required.Exposure limit value :NAExposure control :Not requiredFacility protective equipment : Shower Eyewash fountainPersonal protective equipment : Lab coat Glasses GlovesChemical resistant glovesSafety glassesHygienic measuresTake off immediately all contaminated clothing. Avoid contact with skin. Wash hands after use.When using the reagents, do not eat or drink.Protection of environmentDo not empty the reagents, used ot not used, into drains or in household refuse (cf. §13).


<strong>MSDS</strong>-IM MYCOFAST Evolution 2 Last updated : 14/04/09 Page : 5/69. Physical and chemical propertiesUMMt UMMlyo S. Mh WellsDescription : Liquid Solid Liquid SolidLimpidColour: Yellow Orangey OrangeyWells :≥104 E SXT L OFX ROX D ≥105 10 4 10 3≥10 4 E SXT L OFX ROX D ≥10 5 10 4 10 3103 10 4 ≥105 D ROX OFX L SXT E ≥104after inoculationbefore inoculationUMMt UMMlyo S. Mh WellsOdour : NA NA NA NAFlash point : NA NA NA NAWater solubility : NA NA NA NApH: 5,9 6,20 6,10 6,3 (wells U.u 10 4 and ≥10 5 )10. Stability and reactivityStable under normal conditions of use and storage (2-8°C) until the expiry date indicated on the box.11. Toxicological informationThe toxicity of the various preparations has been determined using the classification rules in Directive EC (Concentrationlimits / addition of substances)12. Ecological informationThe ecological effect have not been thoroughly investigated.10 3 10 4 ≥105 D ROX OFX L SXT E ≥10 4U.u R.TEST IDTB Mh U.u R.TEST IDTB Mh13. Disposal considerationsDispose of material in accordance with the hygiene rules and current regulations for this kind of product in the country of use.14. Transport informationThe reagents of the kit should be transported in their original packaging, hermetically sealed.The symbol "Store at 2-8°C" only concerns long term storage (warehouse or final user's lab) and excludes the conditions oftransport and use.Transport typeLegislation typeRoad / RailADR / RIDexemptSeaIMDGexempt15. Regulatory informationDevice registered according to : DIRECTIVE 98/79/EC on in vitro diagnostic medical devicesClassification and labelling :DIRECTIVE 1999/45/ECSymbol of danger:XnRisk phrases : 22/34/36/37/38/43Safety phrases : 22/26/45/46/64AirIATAexempt


<strong>MSDS</strong>-IM MYCOFAST Evolution 2 Last updated : 14/04/09 Page : 6/616. Other informationReason of modification: Change § 1,2, and 3Indexn° R phrase2234363738Irritating to skin43 May cause sensitisation by skin contactn° S phrase22 Do not breathe dust26454664Harmful if swallowedCauses burnsIrritating to eyesIrritating to respiratory systemIn case of contact with eyes, rinse immediately with plenty of water and seek medical adviceIf case of accident or if you feel unwell, seek medical advice immediately (show the label where possible)If swallowed, seek medical advice immediately and show this container or labelIf swallowed, rinse mouth with water (only if the person is conscious)This product is exclusively intended for in vitro diagnostic useThe company does not assume any responsibility in case of inappropriate useThis Material Safety Data Sheet is a complement to the Instructions For Use (IFU) but does not replace it. The informationcontained herein was compiled from data presented in various technical sources ; it is believed to be accurate andrepresents our best knowledge at the present time.The company makes no warranty and does not assume any liability for the use of this information, or in case of inappropriatehandling of this product. Users should strictly respect the IFU. It is the user’s responsibility to determine the suitability of thisinformation and to adopt necessary safety precautions.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!