12.07.2015 Views

JM Aerofoil - Angus Air

JM Aerofoil - Angus Air

JM Aerofoil - Angus Air

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CASED 12Performance DataTelephone:01206 222 555Fax:01206 222 9051 Phase 3 Phase1 - 40<strong>JM</strong>/16/4/5/40 3 - 45<strong>JM</strong>/16/4/5/40 5 - 45<strong>JM</strong>/16/2/5/142 - 45<strong>JM</strong>/16/4/5/30 4 - 40<strong>JM</strong>/16/2/5/22Email:fans.uk@flaktwoods.com6 - 40<strong>JM</strong>/16/4/5/40 8 - 45<strong>JM</strong>/16/4/5/40 10 - 45<strong>JM</strong>/16/2/5/207 - 45<strong>JM</strong>/16/4/5/34 9 - 40<strong>JM</strong>/16/2/5/32 11 - 45<strong>JM</strong>/20/2/6/34Express Website:www.flaktwoods.com/expressFan Selector:www.flaktwoods.com/fanselector<strong>JM</strong> <strong>Aerofoil</strong> fan40<strong>JM</strong> - 45<strong>JM</strong>5111049Sound pressure levels quoted are average dBA at 3m distance over a sphere, under freefield conditions and are presented for comparative purposes only .12 3678Fans that include BT or CT motors can be continuously operated at temperatures upto 70°C. When these fans are operating in excess of 50°C they should be run at fullspeed only.For Short cased fans please omit the prefix from the product number and state S-type onenquiries/orders. Product numbers shown are for Long cased fans.Bold text denotes Super Expr ess Product, next day deliver y available if or deredby 4pm.Electrical DataRefProductCodeSpeedrev/minMotorProductNumberPitchAngle(°)MotorRating(kW)220-240V/50Hz/1φFull LoadCurrent(at 230V)(A)StartingCurrent(at 230V)(A)WiringDiagramRefSpeed ControllerElectronicTransformer1 40<strong>JM</strong>/16/4/5/… 1420 BT9 DX411452 40 0.32 2.2 5 CD1705 ME1.3 MT1.5 52 1.50 1.31 1.07SoundLeveldBAm 3 /s at Pa (Static)0 50 100 150 200 250 300 400 500 6004 40<strong>JM</strong>/16/2/5/… 2840 CT9 JL411203 18-22 1 6.8 21 CD1705 N/A N/A 66 1.92 1.87 1.81 1.75 1.69 1.61 1.54 1.35 1.102 45<strong>JM</strong>/16/4/5/… 1420 BT9 JL461452 24-30 0.32 2.2 5 CD1705 ME1.3 MT1.5 52 1.82 1.62 1.41 1.133 45<strong>JM</strong>/16/4/5/… 1420 CT5 DX461466 40 0.39 2.9 5.6 CD1705 ME1.3 MT1.5 56 2.19 1.96 1.675 45<strong>JM</strong>/16/2/5/… 2840 CT9 JL461201 10-14 1 6.8 21 CD1705 N/A N/A 66 2.13 2.05 1.99 1.91 1.84 1.77 1.68 1.50 1.29 1.01RefProductCodeSpeedrev/minMotorProductNumberPitchAngle(°)MotorRating(kW)380-420V/50Hz/3φFull LoadCurrent(at 400V)(A)StartingCurrent(at 400V)(A)WiringDiagramRefSpeed ControllerTransformer6 40<strong>JM</strong>/16/4/5/… 1420 BT9 DX431452 40 0.29 1 3 CD1559 MT3.1 FWX1 52 1.50 1.32 1.07InverterSoundLeveldBAm 3 /s at Pa (Static)0 50 100 150 200 250 300 400 500 6009 40<strong>JM</strong>/16/2/5/… 2840 CT9 DX431203 8-32 1.6 3.8 17.5 CD1344 N/A FWX2 66 2.59 2.51 2.43 2.35 2.26 2.17 2.08 1.86 1.617 45<strong>JM</strong>/16/4/5/… 1420 BT9 JL481452 8-34 0.39 1.3 3.9 CD1559 N/A FWX1 52 1.99 1.77 1.51 1.228 45<strong>JM</strong>/16/4/5/… 1420 CT5 DX481460 40 0.53 1.8 4.9 CD1559 MT3.2 FWX1 56 2.20 1.96 1.6810 45<strong>JM</strong>/16/2/5/… 2840 CT9 JL481202 8-20 1.6 3.8 17.5 CD1344 N/A FWX2 66 2.71 2.64 2.56 2.48 2.40 2.32 2.23 2.04 1.8111 45<strong>JM</strong>/20/2/6/… 2840 F22 EX481205 8-34 3.8 7.2 64 CD1343 N/A FWX4 72 3.88 3.80 3.72 3.63 3.55 3.46 3.37 3.18 2.96 2.71Wiring diagrams can be found on pages 22-23The fan noise levels shown are for the specified operating point. When an electronic controller is incorporated, a magnetic not e (enhanced motor noise) can occur - par ticularly if the fan is operating at speeds well below maximum.For noise sensitive applications FWL recommend using an auto transformer speed controller . Fans are supplied at catalogue stat ed angle. Should you wish for the pitch angle to be adjusted, we would be happy to of fer a quotation

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!