12.07.2015 Views

Policy for the Prescription, Administration and Monitoring Of Oxygen ...

Policy for the Prescription, Administration and Monitoring Of Oxygen ...

Policy for the Prescription, Administration and Monitoring Of Oxygen ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Tracheostomy maskDESCRIPTIONMask designed <strong>for</strong> “neck breathing patients”. Fits com<strong>for</strong>table over tracheostomy or tracheotomy.Exhalation port on front of mask. This is a variable per<strong>for</strong>mance device.PURPOSEThis is a variable per<strong>for</strong>mance device <strong>for</strong> patients with a tracheostomy or tracheotomy. Theoxygen delivered will be influenced by <strong>the</strong> oxygen flow rate <strong>and</strong> <strong>the</strong> patient’s tidal volume <strong>and</strong>breathing rate.ACTION1 Gently place mask over <strong>the</strong> patient’sairway, position <strong>the</strong> strap behind <strong>the</strong>head <strong>the</strong>n carefully pull both endsthrough <strong>the</strong> front of <strong>the</strong> mask untilsecure.2 Adjust <strong>the</strong> oxygen flow rate toachieve <strong>the</strong> desired target saturationrange. Start at 4 l/min <strong>and</strong> adjust <strong>the</strong>flow up or down as necessary toachieve <strong>the</strong> desired oxygensaturation range.RATIONALEEnsure a com<strong>for</strong>table fit <strong>and</strong> delivery ofprescribed oxygen is maintained.To ensure that <strong>the</strong> correct amount ofoxygen is given to keep <strong>the</strong> patient in <strong>the</strong>target range.3 For any prolonged period ofoxygen treatment via atracheostomy mask humidificationshould be considered ei<strong>the</strong>r via acold or heated system.4 If <strong>the</strong> patient is requiring anemollient <strong>for</strong> <strong>the</strong> treatment of dryskin secondary to oxygen <strong>the</strong>rapy awater based product should beused. Suitable products includeaqua gel <strong>and</strong> aqueous creamParaffin based products should not be usedin any circumstance as <strong>the</strong>y are flammablewith oxygen<strong>Policy</strong> <strong>for</strong> <strong>the</strong> prescription, administration<strong>and</strong> monitoring of emergency oxygen in adultsPage 28 of 34

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!