<strong>SUBMITTAL</strong> <strong>RD050MHXCA</strong><strong>Job</strong> <strong>Name</strong><strong>Location</strong><strong>Purchaser</strong>EngineerSubmitted toReferenceUnit Designation Schedule #SpecificationsPerformancePowerFanAirflowCompressorRefrigerantPipingConnectionsDimensionsSound LevelOperatingTemperatureRangeUS TonNominalCapacityCooling (Btu/h) 48,000Heating (Btu/h) 54,000Cooling (Btu/h) 47,500Heating (Btu/h) 52,500System Modulation (%) 17 - 100With Ducted UnitsSEER / HSPF With Non-DuctedUnitsHeating COP13.10 / 7.913.9 / 8.103.77Voltage (ø/V/Hz)1/208 - 230/60NominalRunningCooling20.0Current (A) Heating18.6Circuit Breaker (MCCB/ELB/ELCB)40AType/ControlPropeller/BLDCMotorQty.2Output (W)130Airflow Rate(CFM)CoolingHeating3,4003,600ModelTypeNumberPiston Displacement (in³/Rev)TypeLubricantCharging (fl. Oz)TypeFactory Charge (oz.)Charged ForLiquid (inches)Suction (inches)Installation Max. Length (Feet)Limitation Max. Height (Feet)W x H x D (inches)Weight (lbs.)Outdoor Noise Level (dB)R410A14125 feet3/85/82299836 3/4 x 46 x 14 3/4238Cooling (°F) 23 - 115Heating (°F)With Ducted IndoorUnitsWith Non-DuctedIndoor UnitsControl Communication Cable (AWG #) Shielded AWG 16High pressure switchCompressor/accumulator crank caseMechanical TypeheaterProtectionPCB fuseDevicesOver-voltage protectionElectronic TypeCurrent transformerFan motor voltage protectionIndoor UnitsTotal Capacity (%)50 - 130% of outdoor capacityMax. Indoor Unit Quantity8Safety CertificationsETL & ETLc*Nominal cooling capacities are based on: Indoor temperature: 80⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB.*Nominal heating capacities are based on: Indoor temperature: 70⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB.Quietside maintains a policy of ongoing development, specifications are subject to change without notice.Quietside West : 8750 Pioneer Blvd, Santa Fe Springs, CA 90670 • Phone : 888-699-6067 • Fax : 562-699-4351Quietside Central : 3001 Northern Cross Blvd. Suite 361, Fort Worth, TX 76137 • Phone : 817-838-6066 • Fax : 817-838-8670Quietside East : 6 Pine Hill Drive, Carlisle, PA 17013 • Phone : 1-877-262-4731 • Fax : 717-243-7917www.SamsungSystemAC.com4G5T450FUCEXTwin BLDC Rotary12.624POE4453-4 - 75DVM Mini Heat Pump CondenserPage 1 of 2ConstructionThe unit shall be galvanized steel with abaked on powder coated finishHeat ExchangerThe heat exchanger shall be mechanicallybonded fin to copper tubeControlsThe unit shall be operated via a DDC typesignalControls shall integrate with a BMS systemControl wiring shall be 16AWG shieldedwireRefrigerant SystemThe refrigerant shall be R410AThe compressor shall be hermeticallysealed, inverter controlled, Twin BLDCRotaryRefrigerant flow shall be controlled by EEV(electronic expansion valve) at indoor unitsQS-DVM-0211A


<strong>SUBMITTAL</strong><strong>RD050MHXCA</strong>DVM Mini Heat Pump CondenserPage 2 of 2Unit: mm (inch)No.1234<strong>Name</strong>Suction pipe connectionLiquid pipe connectionCondensate drain holePower & communication wiringwww.SamsungSystemAC.comDescription3/8"5/8"ø 20 mm (fitting provided)ø 1" X 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!