<strong>Hoval</strong> <strong>BioLyt</strong> (<strong>50</strong>-<strong>70</strong>)Technical Data<strong>Hoval</strong> <strong>BioLyt</strong>Type (<strong>50</strong>) (<strong>70</strong>)• Nominal output kW 49 69• Daily output 3 approx. kWh 1100 1400• Heat input at nominal output kW 54 74• Heat output area kW 14-49 20-69• <strong>Pellet</strong>s Ø mm 6-8 6-8Length mm 5-30 5-30• Maximum <strong>boiler</strong> flow temperature °C 80 80• Minimum <strong>boiler</strong> operating temperature °C 60 60• Minimum <strong>boiler</strong> back flow temperature °C 45 45• Exhaust temperature with nominal output °C 1<strong>70</strong> 1<strong>70</strong>• Exhaust temperature with lowest nominal output °C 90 90• Carbon dioxide CO 2% 12 12• Operating-/test pressure bar 3,0/4,5 3,0/4,5• Boiler efficiency at nominal output % > 90 > 90• Exhaust mass flow rate at nominal output watercontent of pellets 10 %kg/h 120 1<strong>70</strong>• Exhaust mass flow rate at lowest nominal output kg/h 38 53• Flow resistance pellets<strong>boiler</strong> z-value 1,5 1,5• upstream resistance at 10 K mbar 25 55• upstream resistance at 20 K mbar 7 16• Water flow at 10 K m³/h 4,2 6,4• Water flow at 20 K m³/h 2,1 3,2• Boiler water content Liter 180 215• Fuel-loading chamber capacity Liter 240 240• Ash area capacity Liter 65 65• Thickness of insulation of <strong>boiler</strong> body mm 80 80• Boiler weight(without lagging, burner, pellets hopper) kg 390 520• Boiler weight(with lagging, burner, pellets hopper) kg 640 780Thermal flow safeguard• Switching point of thermal flow safeguard °C 95 95• Minimal flow of water(cold water 10 °C)m³/h 2,0 2,0• Minimum required cold water flow pressure bar 2 2Exhaust plant 1• minimum downward <strong>boiler</strong> pressure Pa 5 5• Electrical intake capacity in operation Watt 1<strong>70</strong> 1<strong>70</strong>• Electrical intake capacity during ignition Watt 1800 1800• Electrical intake capacity during introduction of pellets Watt 1900 1900• Maximum current intake 2 A 13 131The installation of a damper is generally recommended.If there is a flue draught of over 20 Pa it is compulsory.Explosion door is required.2Min. 13 A protection because of operating current.3Taking account of the filling periodsPumping system basic kit type RAS 41Output length [m]maximum possibleoutput height [m]15 bis 25 1,810 bis 15 2,85 bis 10 4,5Subject to modification, 1.6.2010455

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!