Data SheetSS/SR250B_2<strong>Inform</strong> IT<strong>250mm</strong> <strong>Multipoint</strong> <strong>Strip</strong> <strong>Chart</strong> <strong>Recorder</strong>SR250B■ 12-channel recording on <strong>250mm</strong> chart– with individual trace colors■ Universal process inputs– accepts thermocouples, RTDs, mA, mV & V■ Clear text annotation on chart– time, date, scales, speed, alarms and batch■ High clarity graphics display– shows process status at a glance■ Dust- and water-resistant to IP65 (NEMA3)– for harsh industrial environments■ Modbus serial communications– provide full integration with your control systemSR250B– Simplicity and ease of use in arugged, compact <strong>250mm</strong> recorder


<strong>250mm</strong> <strong>Multipoint</strong> <strong>Strip</strong> <strong>Chart</strong> <strong>Recorder</strong>SR250BSS/SR250B_2SR250BThe SR250B provides accurate and reliable recording of upto 12 process signals on a <strong>250mm</strong> wide chart. In-built textprinting capabilities give clear annotation on the chart oftime, date, scales and other process information.The clear view of process status from the LCD display, withthe simplicity of chart and pen replacement, make theSR250B extremely easy to operate.The recorder is designed for panel-mounting and providesIP65 (NEMA3) dust and water protection on the front face,making it suitable for use in harsh environments.The SR250B can be configured for a wide range of inputtypes and chart speeds and is ideal for most industrialrecording applications.Application areas include:■ Heat Treatment■ Ceramics Manufacture■ Cold Storage■ Power GenerationProcess ConnectionsUp to 12 Universal Inputs• Thermocouple• RTD• mA• millivolts• Volts• Up to 12 Traces• <strong>Chart</strong> Annotation• Alarm Messages• Time/Date• Trace Indentifiers45mA TransmitterPower Supply12 x Relay Outputs2 x 70mA TransmitterPower SupplyRS485 Modbus RTU1 x Digital InputStandardOptional2


<strong>250mm</strong> <strong>Multipoint</strong> <strong>Strip</strong> <strong>Chart</strong> <strong>Recorder</strong>SR250BSS/SR250B_2RecordingThe SR250B’s high-speed multi-point printing system updatesall 12 traces in 2.2 seconds. This system produces continuouslines on the chart at speeds of up to 500mm/hr.The printing sequence is intelligently managed by the recorder’scontrol system to give priority to fast-changing signals, ensuringthe most comprehensive process record is traced on the chart.The SR250B supports full text printing to provide detailedannotation on the chart. In addition to the time, date, channelidentity and chart speed, the recorder can print scales for eachchannel, alarm messages and an Operator-entered batch name.The 'Easy-view' facility enables the user to see the latestrecordings at the push of a button.OperationA graphic liquid crystal display (LCD) provides exceptional clarityfor day-to-day operation and for configuration.During normal operation the display cycles through eachchannel in sequence, showing the measured value, engineeringunits, description and channel identifier.Clear text prompts on the LCD display assist the Operator inaccessing functions such as chart reload and alarmacknowledge. Tactile membrane keys on the front of therecorder are used to access these functions. A second, identicalkeypad is provided inside the recorder for use when the door isopen.Unique Post-incident Analysis(Cue-and-Review)The SR250B’s unique 'Cue-and-Review' facility allows the userto rapidly search any part of the roll chart for process events oralarm occurrence – enabling rapid and accurate analysis ofprocess records.Password protection prevents unauthorized access to therecorder’s configuration.Quickly-fitted pen cartridges and an easily-removable chartcassette ensure simple and efficient pen and chart replacement.3


<strong>250mm</strong> <strong>Multipoint</strong> <strong>Strip</strong> <strong>Chart</strong> <strong>Recorder</strong>SR250BSS/SR250B_2Set-upThe SR250B can be easily set up to match your process in eitherof two ways:Entry of the correct password via the keypad on the front of theunit gives access to the recorder's configuration. A simple menustructure with clear text descriptions provides an intuitiveapproach to the recorder set-up.The preferred configuration method for multiple SR250Brecorders is by means of the PC Configurator. This Windowsbasedpackage provides a simple 'point-and-click' approach togenerating a full recorder configuration off-line. The completedconfiguration can be printed-out or saved onto disk before beingdownloaded to the recorder.An SR250B interface cable is used to provide the connectionbetween the PC’s serial port and the configuration port on therecorder.Option ModulesAll recorders are fitted with at least one universal input modulefor analog process signals plus a transmitter power supply for upto two 2-wire transmitters.The capabilities of your recorder can be extended by theaddition of further option modules. Each recorder can supportup to 2 input modules plus 3 option modules.I/O OptionsTypeStandardUniversalInputs3, 6, 9 or 12OptionRelays0 12TransmitterPower Supply (loops)2 12SerialCommunicationsX ✓4


<strong>250mm</strong> <strong>Multipoint</strong> <strong>Strip</strong> <strong>Chart</strong> <strong>Recorder</strong>SR250BSS/SR250B_2Application Function Overview09:00 PaA PaANOThe recorder prints time, date and chart speed automatically at regular intervals.Channel scales and batch identifiers can also be printed on the chart periodically oron demand.Up to 24 process alarms can be set up within the recorder. Alarm status can beprinted on the chart and the alarms can operate relay outputs or change the chartspeed.5V0VNCA maximum of 12 relays can be fitted within the recorder for use as alarm outputs. Asingle common relay can be set to be triggered by multiple alarms.A digital input is provided on every Input Module for remote changing of chart speedor for alarm acknowledgment.RS485 2- or 4-wire communications using Modbus protocol provides a real-time linkto SCADA systems or PLCs.Temperature RecordingRecording of temperature, using both direct-connectedthermocouples and RTDs or 2-wire field-mountedtransmitters, is common in a wide range of industries suchas Aerospace, Car component, Food, Chemical and Kiln/Ovens.The SR250B can accept direct connection to all standardthermocouples, Pt100 resistance thermometers and 4 to20mA transmitters, and record on up to 6 channels ordatalog up to 12 inputs.Operator messages allow printing of configurable messages such as'Start of Test' or 'Cycle Complete' for a clear record of the batch.For electric ovens fit the 500V isolator card to avoid conductance on thethermocouple which causes noise on the chart.SR250BTemperature Monitoring and AlarmsIn food production, it is essential to monitor theconditions in Cold Stores and TemperaturecontrolledRooms to provide the user with a recordthat the goods have been stored at the correcttemperature.The simplest and easiest way to do this is with theSR250B strip chart recorder, which can take up to6 inputs from RTDs spread across a cold store or anumber of food preparation areas.At a chart speed of 20mm/hour, the unit providesrecording for one month and, when fitted with relayoutput modules, provides alarm functions.TemperatureSensorConnectionsLoading andUnloading BayFrozen Food Store(not drawn to scaleas stores may be verylarge – e.g. 10,000m 2and larger)Temperature Sensors(individual cable runs tothe SR250B <strong>Recorder</strong>ensure accuracy andprofile of store )Racking andStorage PalletsControl CabinSR250B5


<strong>250mm</strong> <strong>Multipoint</strong> <strong>Strip</strong> <strong>Chart</strong> <strong>Recorder</strong>SR250BSS/SR250B_2Specification<strong>Chart</strong>TracesUp to 12ColorsChannels 1 to 6Channels 7 to 12Magenta, Red, Black, Green,Blue and BrownBi-color, Z-tracesPen life3 months typically (at 20mm/hr with normal scale printing)<strong>Chart</strong>25m Roll chartQuick-load cassetteStandard chart graduation 100 divisions80, 120, 140, 150 divisions also available<strong>Chart</strong> speedConfigurable between 1 and 1500mm/hr in 1mm/hr stepsRemote speed changeTrace response2.2s for print-out of 12 traces1.5s for print-out of 6 tracesTrace resolution0.2mmText messages1 operator message for batch identification (20-characters)24 alarm messages (20 characters)OperationGraphics display – backlit LCDCharacters 10.4mm high– process variables5.1mm high – textDisplay of process variableEngineering range –999 to +9999LanguagesUser-configurable for English, French or GermanKeysSealed tactile membraneduplicate keypads on door andinside caseAnalog InputsNumber3 or 6 Standard9 or 12 OptionalInput sampling rate125ms per channel – 12 channels in 1.5sTypeUniversally configurable for:Thermocouple (THC)Resistance thermometer (RTD)Millivolt, Current, Voltage, ResistanceLinearizer functionsProgrammable for all inputs including √, x 3 / 2, x 5 / 2THC types B, E, J, K, R, S, T, L, N, Pt100Two 20-breakpoint custom linearizersBroken sensor detectionProgrammable to drive Upscale or DownscaleRTD short/open circuit detectionCold junction compensationAutomatic CJC incorporated as standard< 0.05°C per °C (0.1°F per °F)/change in ambientInput impedanceCurrentVoltagemV & THC10Ω500kΩ>10MΩ2-wire transmitter power supply45mA max. (2 loops), fitted as standardAdditional loops can be powered from optional TXPSU modulesInputChannel-to-channelChannel to ground12V DC dielectric strength500V DC dielectric strengthCommon mode rejection>120dB at 50/60Hz with 300Ω imbalance resistanceSeries mode rejection>60dB at 50/60HzTemperature stability0.02% of reading/°C (0.01% of reading/°F) or 2µV/°C(1µV/°F) (whichever is greater)Long term drift< 0.01% of reading or ±5µV annuallyFilteringOff, 5 to 60s digital filter6


<strong>250mm</strong> <strong>Multipoint</strong> <strong>Strip</strong> <strong>Chart</strong> <strong>Recorder</strong>SR250BSS/SR250B_2Alarms24 high/low process alarms with programmable leveland time hysteresis4 real-time events with programmable on-time and durationElectricalPower supply85 to 265V 50/60Hz24V DC ±4V (optional)Line interruption80ms loss, auto-reset and restartPower consumption35VA maxElectrical safetyEN61010-1, IEC348CSA (optional)Electrical connectionsScrew terminalsOption Modules3- or 6-relay output moduleUniversally assignable to any alarm signalRelay type Single pole changeoverVoltage 250V AC 30V DCCurrent 5A AC 5A DCLoading (non-inductive) 1250VA 150WNote. The total load for all relays within the instrument must notexceed 36A.2-wire transmitter power supply moduleTwo isolated 24V outputs (45mA each)Each output capable of driving 2 loopsRS485 serial communication (Modbus) moduleEIA communications standard RS485 (2- or 4-wire)ProtocolModbus RTU (slave)Baud rate User selectable up to 9600Isolation500V from rest of instrumentPhysicalSize326.8mm (12.87 in.) x 147mm (5.78 in.)x 230mm (9.00 in.) (depth behind panel)Weight


<strong>250mm</strong> <strong>Multipoint</strong> <strong>Strip</strong> <strong>Chart</strong> <strong>Recorder</strong>SR250BSS/SR250B_2...SpecificationInput Ranges and AccuracyInput RangesInputTypeMin.ValueMax.ValueMin. SpanMillivolts– 200020002. 5Volts– 20200.25Milliamps– 1001000.25Resistance0 800010Accuracy (% ofreading)± 0.1%o r ± 10µV± 0.2%o r ± 2mV± 0.2%o r ±2µA± 0.2%o r ± 0.08ΩThermocouple and RTD Ranges and AccuracyTHC/RTD°C °FTypeM in.Max.Min.SpanA ccuracyM in.Max.Min.SpanAccuracyTypeB– 181800710± 2.0*0 32721278± 3.6*TypeE– 10090045± 0.5– 148165281± 0. 9TypeJ– 10090050± 0.5– 148165290± 0. 9TypeK– 100130065± 0.5– 1482372117± 0. 9TypeL– 10090050± 0.5– 148165290± 0. 9TypeN– 200130090± 0.5– 3282372162± 0. 9TypeR & S – 181700320± 0.1*0 3092576± 1.8*TypeT– 25030060± 0.5– 418572108± 0. 9* Performance accuracy is not guaranteed below 300ºC (572ºF) for B, R and S thermocouplesM in. span below zero Type T 70ºC (126ºF)Type N 105ºC (189ºF)THC standards DIN 43710IEC 584RTD***– 20060025± 0.5** – 328111245± 0.9* ***For temperatures between 300 and 600ºC (527 and 1112ºF) accuracy is ± 1 .0ºC ( ± 1.8ºF)***RTD,3-wire platinum, 100Ω perDIN43760 standard (IEC751), with range of 0 to 400Ωs8


<strong>250mm</strong> <strong>Multipoint</strong> <strong>Strip</strong> <strong>Chart</strong> <strong>Recorder</strong>SR250BSS/SR250B_2Overall DimensionsDimensions in mm (in.)326.8 (12.87)24.2(0.95)230.0 (9.00)219.9 (8.65)147.0(5.78)302.8 +0.8–0.0+0.03–0.00(11.92 )260.0 (10.25)with terminal cover fitted138.0 +0.8–0.0+0.03(5.43 )–0.00PanelCut-out30 (1.2)Note. Max. mounting angle 30° from verticalElectrical ConnectionsNote. Refer to instrumentcode for module positionsA, BAnalog InputConnector1234567891011121314151617181920+Analog I/P 1–3 rd lead RTD+Analog I/P 2–3 rd lead RTD+Analog I/P 3–3 rd lead RTD+Analog I/P 4–3 rd lead RTD+Analog I/P 5–3 rd lead RTD+Analog I/P 6–3 rd lead RTDLogic I/P0VInstrument viewed from rearA B E F G HE, FRelay Output1234567891011121314151617181920NCNOCNCNOCNCNOCNCNOCNCNOCNCNOCRelay 1Relay 2Relay 3Relay 4Relay 5Relay 6E, F, GTransmitter d.c.Power Supply1234567891011121314151617181920++––––++––HPower Supply1234567824VSpareSpare24VLNE+–+24V0VLineNeutralEarth+–+–ACDC2-wire TransmitterDC PowerGRS485 Comms1234567891011121314151617181920––++–++–––TX 4-wireTX 4-wireSpareTX/RX 2-wire & RX 4-wireTX/RX 2-wire & RX 4-wireSpareCommon9


<strong>250mm</strong> <strong>Multipoint</strong> <strong>Strip</strong> <strong>Chart</strong> <strong>Recorder</strong>SR250BSS/SR250B_2Ordering <strong>Inform</strong>ationS R250B <strong>Multipoint</strong> <strong>Chart</strong> <strong>Recorder</strong>S R250B / XXS/ X00Number of Traces and Input Channels36912BuildABB StandardCSA (pending)UL (pending)Option Module ENone3 relays6 relaysTransmitter power supply unitOption Module FNone3 relays6 relaysTransmitter power supply unitOption Module GNoneModbus serial communicationsTransmitter power supply unitCase OptionStandard panel mountStandard + terminal cover<strong>Chart</strong> Type0 30 60 91 2BCU/ X X X / X X X XXRollchart1Power Supply85V to 265V AC24V DCProgramming/Special FeaturesConfigured to factory standardConfiguredto customer requirements – seeConfiguration Detailsopposite036T036T0ST1223STCMAccessoriesPC Configurator kit (part no. C100/0700)Licensing, Trademarks and CopyrightsModbus is a trademark of Modicon, Inc.Windows is a trademark of the Microsoft Corp.10


<strong>250mm</strong> <strong>Multipoint</strong> <strong>Strip</strong> <strong>Chart</strong> <strong>Recorder</strong>SR250BSS/SR250B_2Configuration DetailsFor instrument configuration please complete this form and return it with your order.Channel123456789101112STInputTypemALinearizationTypeUnitsTHC and Pt100LinearizerRangeZeroSpanZeroRangeSpanmA, mV, V and ResistanceDisplayZeroSpanNone4 200 1000Unitse.g.1e.g.2ote. DefaultmAN one– – – 4 200 100barTHCR °C 0 1400– – – – –is as ST aboveN configuration.11


<strong>250mm</strong> <strong>Multipoint</strong> <strong>Strip</strong> <strong>Chart</strong> <strong>Recorder</strong>SR250BSS/SR250B_2ABB has Sales & Customer Supportexpertise in over 100 countries worldwidewww.abb.comThe Company’s policy is one of continuous productimprovement and the right is reserved to modify theinformation contained herein without notice.Printed in UK (02.04)© ABB 2004SS/SR250B Issue 2ABB LimitedHoward Road, St NeotsCambridgeshirePE19 8EUUKTel: +44 (0)1480 475321Fax: +44 (0)1480 217948ABB Inc.125 E. County Line RoadWarminsterPA 18974USATel: +1 215 674 6000Fax: +1 215 674 7183

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!