12.07.2015 Views

Technical Bulletin

Technical Bulletin

Technical Bulletin

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

R56 Series Instrument ManifoldsPressure Ratings up to 6000 psigCatalog No. V56/V46-3Nov. 2004Valve FeaturesBAR HANDLESET SCREWSTEMBleed, Block and Equalizer valve for V56 seriesManifolds & V46 series Gauge Root ValvesPACKING NUTLOCK NUTBONNETLOCKINGPINSHEVRON PACKINGSTEM TIPValves for Manifolds and Gauge Root ValvesNon-rotating stem tip at closure for long-life and leak-tightshutoff. Blunt VEE tip.Exclusive 4-piece chevron PTFE packing design providesfar improved sealing integrity. Optional Grafoil packing.Isolated Threads : Packing located below threads preventsmedia contamination and thread lubricant washout.Stem is mechanically ENGAGED with the bonnet as well asthreaded with the packing nut for max. safety.Safety Locking Pin ensures the valve fastened to the bodywhen excessive opening torque is applied, and is vibrationtested to MIL-STD-167-1 (SHIPS).Sturdy T-Bar handle:a.B.D-Pro VBR56 Manifolds FeaturesSimple to installBurr-free internal surfaceS316 constructionOperating at 6000 psig (413 bar)Standard PTFE and optional*Grafoil packingEvery valve is factory tested withnitrogen 1000 psig (68 bar).VBR56-2V-8NBlock and Bleed2 valve Remote Mount ManifoldPipe to pipe ½ female NPTBleed port ½ female NPTFlow measurement diagramGauaeRootValveOrifice PlateFlowProcess LineProcessSideImpulseLineVBR56-3V-8NBlock and Equalizer3 valve Remote Mount ManifoldPipe to pipe ½ f emale NPTBleed port ¼ female NPTManifoldBlockValveHigh LowTransmitterInstrumentSideManifoldEqualizerValveVBR56-5V-8NBlock, Equalizer and Bleed5 valve Remote Mount ManifoldPipe to pipe ½ f emale NPTBleed port ¼ f emale NPTQuality SystemApprovalASME AccreditedNuclear & ISO9001Quality SystemDk-Lok Tube Fitting Certification ListingD-Pro Valve Certification Listing56/46 Serieswww.dklok.comwww.dklokusa.com


Manifolds56 SeriesDesignD-Pro Manifold design meets hydrostatic test at 1.5 times the working pressure.Safety Locking Pin preventing detachment of bonnet from body is vibration tested to MIL-STD-167-1Pressure boundary wetted parts are selected to Chapter III, Material of B31.1, 123 Acceptable Materials.Ordering Information and <strong>Technical</strong> DataManifoldTypeRemoteMountDirectMountOrderingNumberVBR56-2V-8NVBR56-3V-8NVBR56-5V-8NVBD56-2V-8NVBD56-3V-8NVBD56-5V-8NEnd ConnectionsProcessInstrument1/2" Female NPT1/2" Female NPT1/2" Female NPT1/2" FemaletoFlangePressure RatingPTFE packingpsig (bar)6000 (413) at100 F (37C)3000 (210) at450 F (232C)Temperature RatingPTFE Grafoilpacking packing-53C to232C(-65F to450F)-53C to523C(-65F to973F)Orifice ofBlock Valvemm ( in.)WeightKg (lb)3.2 (0.126) 0.78 (1.71)6.4 (0.251) 1.92 (4.23)2.1 (4.59)3.2 (0.126) 1.6 (3.5)6.4 (0.251) 1.64 (3.6)3.1 (6.8)Pressure Rating optional Grafoil packing: 1715 psig (118 bar) at maximum temperature 973F (523C).To order the optional Grafoil packing, add -GF to the ordering number. i.e., VBR56-3V-8N-GFOperation and Application2-valveVBR56-2V & VBD56-2V seriesFor isolating, calibrating and drainingpressure gauges and transmittersIn operation, the block valve isnormally open when the bleed valveis closed. To remove the instrument,close the block valve first, and openthe bleed valve to relieve pressureupstream of the block valve.For calibration, by connecting acalibration gauge to the bleed port,able to check the calibration of theinstrument without removing it fromthe installation.3-valveVBR56-3V & VBD56-3V seriesFor measuring flow or level usinga differential pressure transmitter.In operation, both block valves areopen while the equalizer valve isclosed to read a differential pressureto the pressure gauge or transmitter.To zero the instrument, close theblock valve first then open theequalizer valve and zero adjust theinstrument.To remove the instrument, closeblock valves first, then unscrew thebleeding plug to relieve pressurebetween the manifold andinstrument.5-valveVBR56-5V & VBD56-5V seriesFor measuring flow or level using a differentialpressure transmitter or gauge with bleeding,calibration and test functions.In operation, both block valves areopen while the equalizer and bleedvalves are closed to read adifferential pressure to the pressuregauge or transmitter. To zero theinstrument, close block valves andbleed valve, and open the equalizervalve and zero adjust the instrument.For calibration, connect the bleedport to a pressure gauge to checkthe calibration of the instrument.Packing adjustment : Extreme or rapid temperature cycle may require packing adjustment to maintain a leak-free system.Tightening the Locknut on the bonnet is for the packing adjustment.D-Pro V46 series Gauge Root ValvesD-Pro Gauge Root Valves offer a safe way of positioning gauges and installing pressure switches.DesignThis valve is designed to ASME B16.34 Class 2500S316 construction with the minimum schedule 160 pipe wall on valve inletV46GRL Series : Extended body allowing 4.0" of pipe insulationFeatures1/2" and 3/4" male to 1/2" female end connections1/2" female gauge ports standardNon-rotating stem tip designSour gas option to NACE MR0175 latest version3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!