water faultsgas schematicservicesWATERFault Cause RemedyWater flows Cold water pipe kinked Check and re-route if necessaryfrom hot preventing flowtap but hasBlockage in cold pipe line Disconnect pipes after 1st connector andreduced flowcheck up to tapfrom coldCold tap not connectedCold tap failed or blockedRefer to installation instructionsDisconnect and inspectReduced flowfrom both hotand cold tapsReduced flowfrom either tapIf pump motorruns steadilyand will notstopBattery condition lowcausing pump torun slowlyIf new taps have been fittedthey may be restricting flowPump needs servicingPartially blocked pump filteror in-line filter, if fittedPump outlet pipe kinkedrestricting flowWater leakPipe kinking restricting flowBattery voltage may betoo low (below 10.5 volts)Pressure Switch settingproblemCheck battery state of charge,refer to electrical supply noteDisconnect and check that they have at least1/4” (6.3mm) boreRefer to pump servicing instructionsDismantle and clean if necessaryCheck and re-route if necessaryCheck all water connectionsCheck and re-route if necessaryCheck that there is water in the containerAdjust switch and/or re-charge batteryCheck all connections in pipework.Adjust settings.Typical gas schematic drawingNote: Depending on the caravan model, the gas isolation tap for the water heater maybe located close to the appliance.services5455