12.07.2015 Views

18. MULTI-TYPE(V MULTI) PACKAGED AIR-CONDITIONER Split ...

18. MULTI-TYPE(V MULTI) PACKAGED AIR-CONDITIONER Split ...

18. MULTI-TYPE(V MULTI) PACKAGED AIR-CONDITIONER Split ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

V <strong>MULTI</strong><strong>18.</strong>2.7 Characteristics of fan• External static pressure table How to interpret the blower characteristics tableUnit: Pa (mmAq)Example : Case of FDR308-ATypeDuct specs. 1 spot closing (1) Standard (2) Square duct (3)Air flow(m 3 /min)FDR208-AFDR258-AFDR308-AFDR408-AFDR508-A1418202834Highspeed (4)Highspeed (4)StandardStandardStandardHighspeed (4)— — 50(5) 85(8.5) 50(5) 90(9)30(3) 65(6.5) 45(4.5) 80(8) 50(5) 85(8.5)25(2.5)40(4)60(6)70(7)45(4.5)50(5)80(8)80(8)50(5)50(5)85(8.5)85(8.5)40(4) 70(7) 50(5) 80(8) 55(5.5) 85(8.5)Notes (1) 1 spot closing: Round duct flange at center is removed and shieldwith a decorative panel (option).(2) Standard: ø200 ducts are installed at all blowout holes.(3) Square duct: All round ducts are removed and replaced with specialsquare duct flanges (option).(4) When operating at a high speed, invert the connection of whiteand red connectors on the flank of control box.Static pressure Pa (mmAq)40(4)20(2)0(0)Standard •Low2-spots blowerinternal resistance[Standard]3-spot blowerinternal resistanceSquare duct blower internal resistance–2(–2)Internal resistance without suction panel14Internal resistance without filter• High17 20 22Air flow (m 3 /min)1 2-spot blowout.....................Internal resistance increases morethan the standard 3-spot blowout.Approx. 14 (1.4) Pa (mmAq) at17m 3 /min.2 Square duct blowout...........Internal resistance decreasesmore than the standard roundduct (ø200 3-spot). 3 (0.3) Pa(mmAq) at 17 m 3 /nin. (Externalstatic pressure increases inreverse.).3 Decorative panel...................When the decorative panel is notused with the ceiling return type,the part of internal resistancerelated to the panel decrease. 3(0.3) Pa (mmAq) at 17mm 3 /min.ModelFDR208-AModelFDR258-A120(12)120(12)Static pressure Pa (mmAq)100(10)80(8)60(6)40(4)20(2)High speed •LowHigh speed •Upper limitStandard •Upper limitStandard • LowHigh speed • HighHigh speed •Lower limitStandard • HighStatic pressure Pa (mmAq)100(10)80(8)60(6)40(4)20(2)High speed • Upper limitStandard •Upper limitHigh speed •LowStandard • LowHigh speed • HighStandard • HighHigh speed • Lower limit0(0)0(0)2-spot blower internal resistance[Standard] 2-spot blower internal resistance–20(–2)10LowerlimitSquare duct blower internal resistanceInternal resistance without suction panelInternal resistance without filter12 14 15.5UpperAir flow (m 3 /min) limit[Standard]–20(–2)13Lowerlimit3-spot blower internal resistanceSquare duct blower internal resistanceInternal resistance without suction panelInternal resistance without filter14 16 18 20UpperAir flow (m 3 /min) limit707

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!