AIR VALVE / CENTER SECTION DISASSEMBLYTools Required :Pro-Flo ®• 3/8" Hex Head Wrench• 1/4" Hex Head Wrench• Snap Ring Pliers• O-Ring PickPro-Flo V• 3/16" Hex Head Wrench• 1/4" Hex Head Wrench• Snap Ring Pliers• O-Ring PickCAUTION: Before any maintenance or repair is attempted, the compressed air lineto the pump should be disconnected and all air pressure allowed to bleed from thepump. Disconnect all intake, discharge, and air lines. Drain the pump by turning itupside down and allowing any fluid to flow into a suitable container. Be aware ofhazardous effects of contact with your process fluid.The Wilden <strong>P15</strong> and <strong>PV15</strong> metal pumps utilize a revolutionary Pro-Flo ® airdistribution system. Proprietary composite seals reduce the co efficient of frictionand allow lube-free operation. The Pro-Flo ® air distribution system is designed toperform in on/off, non-freezing, non-stalling, tough duty applications.Step 1Loosen the air valve bolts utilizing a3/8" hex head wrench.Step 2Remove muffler plate and air valvebolts from air valve assemblyexposing muffler gasket forinspection. Replace if necessary.Step 3Lift away air valve assemblyand remove air valve gasket forinspection. Replace if necessary.WIL-10110-E-02 8/06 17 WILDEN PUMP & ENGINEERING, LLC