12.07.2015 Views

GEPVP CPD 4 (EN12150-2).EN.indd - Glass for Europe

GEPVP CPD 4 (EN12150-2).EN.indd - Glass for Europe

GEPVP CPD 4 (EN12150-2).EN.indd - Glass for Europe

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Construction Products DirectiveFigure 3 – Example of a CE Marking label <strong>for</strong> System of Attestation of Con<strong>for</strong>mity 101234 1AnyCo Ltd, PO Box 21, B-10500501234-<strong>CPD</strong>-00234 26mm Thermally toughened (FR) glass<strong>EN</strong> 12150-2Thermally toughened soda lime silicate safety glass(fire resistant), intended to be used in buildings andconstruction works8CharacteristicsResistance to fire E30 3Reaction to fire A1*External fire per<strong>for</strong>manceBullet resistanceExplosion resistanceBurglar resistancePendulum body impact resistanceResistance against sudden temperaturechanges and temperature differentialsWind, snow, permanent and imposedload resistanceDirect airborne sound insulationThermal propertiesNPDNPDNPDNPD1(C)1200K6mm31(-2;-3)dB5,6W/(m 2 .K)Radiation properties:Light transmittance and reflectance 0,85/0,11Solar energy characteristics 0,83/0,131Identification number of the certification body2Certificate number3Reference to the certification report. Traceable from the certification report will be detail(s) of the “virtual kit(s)”used <strong>for</strong> the fire testing.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!