12.07.2015 Views

da ta sheet f111 - dual input flow ra te / to talizer - Klay Instruments

da ta sheet f111 - dual input flow ra te / to talizer - Klay Instruments

da ta sheet f111 - dual input flow ra te / to talizer - Klay Instruments

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Typical wiring diag<strong>ra</strong>m F111-P-CH-PB-OT-(PX)Typical wiring diag<strong>ra</strong>m F111-P-CH-OT-PXTERMINAL CONNECTORSF100 - seriesBATTERY POWEREDTERMINAL CONNECTORSF100 - series8 - 24V AC / DC POWER SUPPLY (BASIC)Modbus communication type CH: RS485 - 2 wireModbus communication type CH: RS485 - 2 wireBACommon ground26 28 29BACommon ground26 27 28 29Circuit depends ontype of signalSupply *SignalCommon ground12 13 14Flowme<strong>te</strong>r <strong>input</strong> Btype: PpulseCircuit depends ontype of signalSupply *SignalCommon ground12 13 14Flowme<strong>te</strong>r <strong>input</strong> Btype: PpulseCircuit depends ontype of signalSupply *SignalCommon ground9 10 11Flowme<strong>te</strong>r <strong>input</strong> Atype: PpulseCircuit depends ontype of signalSupply *SignalCommon ground9 10 11Flowme<strong>te</strong>r <strong>input</strong> Atype: PpulseMain supplyCommon groundCommon groundCommon ground3 4 5 6 7 8Power supply type PX:8 - 30V DC(not used in this example)Pulse output <strong>flow</strong> A - type OT:passive t<strong>ra</strong>nsis<strong>to</strong>r(not used in this example)Pulse output <strong>flow</strong> B - type OT:passive t<strong>ra</strong>nsis<strong>to</strong>r(not used in this example)Main supplyCommon groundCommon groundCommon ground3 4 5 6 7 8Power supply PX: 8 - 30V DCe.g. coun<strong>te</strong>r123456Pulse output <strong>flow</strong> A - type OT:passive t<strong>ra</strong>nsis<strong>to</strong>re.g. coun<strong>te</strong>r123456Pulse output <strong>flow</strong> B - type OT:passive t<strong>ra</strong>nsis<strong>to</strong>r+8 - 30V DC-Please no<strong>te</strong>: PX may be usedin combination with thebat<strong>te</strong>ry!PX will power the unit;the bat<strong>te</strong>ry will be disable<strong>da</strong>u<strong>to</strong>matically untill poweris disconnec<strong>te</strong>d.*Supply vol<strong>ta</strong>ge: 1.2 / 3.2V DC <strong>to</strong> sensor*Supply vol<strong>ta</strong>ge: 1.2 / 3.2V DC <strong>to</strong> sensor4F111


childminder.What about part-time childcare?Many childminders are happy <strong>to</strong> provide families with part-time places for children. They can drop children off at school and pick them up.Childminders can also <strong>ta</strong>ke your child <strong>to</strong> nursery or pre-school as part of the routine.How much does a childminder cost?Childminders set their charges themselves. The ave<strong>ra</strong>ge cost of a childminder in Waltham Forest is £5 per hour, although this will differ depending onlocation.T<strong>ra</strong>ining?All childminders are required <strong>to</strong> have comple<strong>te</strong>d the following t<strong>ra</strong>ining:Completion of “Unders<strong>ta</strong>nding how <strong>to</strong> set up a home-based childcare business”Paediatric First AidSafeguardingWe encou<strong>ra</strong>ge all childminders <strong>to</strong> do further t<strong>ra</strong>ining. Every childminder has an assigned Quality Childminding Development Officer who visits them andprovides support and advice, as well as <strong>to</strong> signpost the childminder <strong>to</strong> further t<strong>ra</strong>ining.Child Tax CreditIf you claim working <strong>ta</strong>x credits, you may be eligible for help with the cost of regis<strong>te</strong>red childcare that you pay for. The amount of <strong>ta</strong>x credits you can getis based on your ave<strong>ra</strong>ge weekly childcare costs. This can amount <strong>to</strong> 70% of your child care cost (up <strong>to</strong> £175 per child, per week).For more information visit www.gov.uk or call the Tax Credit Helpline on 0845 300 3900.No<strong>te</strong>: When claiming for assis<strong>ta</strong>nce with childcare costs please be aware that only regis<strong>te</strong>red childcare can be considered.A GUIDE TO USING THE VACANCY LISTThe London Borough of Waltham Forest has just under 300 regis<strong>te</strong>red childminders, however not every childminder gives us permission <strong>to</strong>advertise/promo<strong>te</strong> their vacancies. The at<strong>ta</strong>ched list is made up of childminders belonging <strong>to</strong> the Vacancy Scheme set up by the FIS.Whilst every effort has been made <strong>to</strong> ensure that the at<strong>ta</strong>ched information is accu<strong>ra</strong><strong>te</strong>, Waltham Forest Family Information Service cannot accept anyresponsibility of liability for any errors. We strongly recommend that you check the de<strong>ta</strong>ils with each provider. As we offer an impartial service we cannotPrin<strong>te</strong>d on 01 May 2013 Page 6 of17


DisplayTypeTechnical specificationGene<strong>ra</strong>lHigh in<strong>te</strong>nsity reflective numeric an<strong>da</strong>lphanumeric LCD, UV-resis<strong>ta</strong>nt.Dimensions 90 x 40mm (3.5" x 1.6").DigitsSeven 17mm (0.67") and eleven 8mm (0.31") digits.Various symbols and measuring units.Refresh <strong>ra</strong><strong>te</strong> User definable: 8 times/sec. - 1 time/30 secs.Option ZB T<strong>ra</strong>nsflective LCD with green LED backlight.Good readings in full sunlight and <strong>da</strong>rkness.No<strong>te</strong> ZB Only available for safe area applications.Ope<strong>ra</strong>ting <strong>te</strong>mpe<strong>ra</strong>tureOpe<strong>ra</strong>tional -30°C <strong>to</strong> +80°C (-22°F <strong>to</strong> +178°F).Intrinsically Safe -30°C <strong>to</strong> +70°C (-22°F <strong>to</strong> +158°F).Power requirementsType PB Long life Lithium bat<strong>te</strong>ry - life-time depends uponsettings and configu<strong>ra</strong>tion - up <strong>to</strong> 5 years.Type PC Intrinsically Safe long life lithium bat<strong>te</strong>ry - life-timedepends upon settings and configu<strong>ra</strong>tion - up <strong>to</strong> 5years.Type PD 8 - 24V AC / DC ± 10%. Power consumption max. 10Watt. Intrinsically Safe: 16 - 30V DC; powerconsumption max. 0.75 Watt.Type PF 24V AC / DC ± 10%. Power consumption max. 15 Watt.Type PL Input loop powered from sensor signal 4 - 20mA(type “A”) - requires type OT.Type PM 115 - 230V AC ± 10%. Power consumption max. 15 Watt.Type PX 8 - 30V DC. Power consumption max. 0.5 Watt.Type ZB 12 - 24V DC ± 10% or in<strong>te</strong>rnally powered with type PD/ PF / PM. Power consumption max. 1 Watt.No<strong>te</strong> PB/PF/PM Not availble Intrinsically Safe.No<strong>te</strong> PF/PM The <strong>to</strong><strong>ta</strong>l consumption of the sensors and outputsmay not exceed 400mA @ 24V.No<strong>te</strong>For Intrinsically Safe applications, consult the safetyvalues in the certifica<strong>te</strong>.Sensor exci<strong>ta</strong>tionType PB/PC/PX 3.2V DC for pulse signals and 1.2V DC for coil pick-up.No<strong>te</strong>This is not a real sensor supply. Only sui<strong>ta</strong>ble forsensors with a very low power consumption like coils(sine wave) and reed-switches.Type PD 1.2 / 3.2 / 8.2 / 12 / 24V DC - max. 50mA @ 24V DC.Type PD-XI 1.2 / 3.2 / 8.2V DC - max. 7mA @ 8.2V DC and mainspower supply vol<strong>ta</strong>ge (as connec<strong>te</strong>d <strong>to</strong> <strong>te</strong>rminal 1).No<strong>te</strong>In case PD-XI and signal A or U: the sensor supplyvol<strong>ta</strong>ge is according <strong>to</strong> the power supply vol<strong>ta</strong>geconnec<strong>te</strong>d <strong>to</strong> <strong>te</strong>rminal 1. Also <strong>te</strong>rminal 2 offers thesame vol<strong>ta</strong>ge.Type PF / PM 1.2 / 3.2 / 8.2 / 12 / 24V DC - max. 400mA @ 24V DC.Terminal connectionsTypeRemovable plug-in <strong>te</strong>rminal strip.Wire max. 1.5mm 2 and 2.5mm 2 .Da<strong>ta</strong> pro<strong>te</strong>ctionTypeEEPROM backup of all settings. Backup of running<strong>to</strong><strong>ta</strong>ls every minu<strong>te</strong>. Da<strong>ta</strong> re<strong>te</strong>ntion at least 10 years.Pass-code Configu<strong>ra</strong>tion settings can be pass-code pro<strong>te</strong>c<strong>te</strong>d.Hazardous areaIntrinsically Safe ATEX approval ref.: II 1 GD EEx ia IIB/IIC T4 T100°C.Type XIMaximum ambient +70°C (158°F).Explosion proof ATEX approval ref.: II 2 GD EEx d IIB T5.Type XF Dimensions of enclosure: 300 x 250 x 200mm(11.8” x 9.9” x 7.9”) L x H x D.Weight Type XF appr. 15 kg.EnvironmentElectromagnetic Compliant ref: EN 61326 (1997), EN 61010-1 (1993).compatibilityCasingGene<strong>ra</strong>lWindowSealingControl keysPolycarbona<strong>te</strong> window.Silicone.Three industrial micro-switch keys. UV-resis<strong>ta</strong>ntsilicone keypad.Aluminum wall / field mount enclosuresGene<strong>ra</strong>l Die-cast aluminum wall/field mount enclosure IP67 /NEMA 4X with 2-component UV-resis<strong>ta</strong>nt coating.Dimensions 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D.Weight 1100 gr.Type HA Cable entry: 2 x PG9 and 1 x M20.Type HM Cable entry: 2 x M16 and 1 x M20.Type HN Cable entry: 1 x M20.Type HO Cable entry: 2 x M20.Type HP Cable entry: 6 x M12.Type HT Cable entry: 1 x 1 / 2 " NPT.Type HU Cable entry: 3 x 1 / 2 " NPT.Type HV Cable entry: 4 x M20.Type HZ Cable entry: no holes.GRP wall / field mount enclosuresGene<strong>ra</strong>l GRP wall/field mount enclosure IP67 / NEMA 4X,UV-resis<strong>ta</strong>nt and flame re<strong>ta</strong>r<strong>da</strong>nt.Dimensions 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D.Weight 600 gr.Type HD Cable entry: no holes.Type HE Cable entry: 2 x Ø 16mm and 1 x Ø 20mm.Type HF Cable entry: 1 x Ø 22mm ( 7 / 8 ").Type HG Cable entry: 2 x Ø 20mm.Type HH Cable entry: 6 x Ø 12mm.Type HJ Cable entry: 3 x Ø 22mm ( 7 / 8 ").Type HK Flat bot<strong>to</strong>m, cable entry: no holes.Panel mount enclosuresDimensions 130 x 120 x 60mm (5.12" x 4.72" x 2.36") - W x H x D.Panel cut-out 115 x 98mm (4.53" x 3.86") L x H.Type HB Die-cast aluminum panel mount enclosure IP65 /NEMA 4.Weight 600 gr.Type HC GRP panel mount enclosure IP65 / NEMA 4,UV-resis<strong>ta</strong>nt and flame re<strong>ta</strong>r<strong>da</strong>nt.Weight 450 gr.ABS wall / field mount enclosuresGene<strong>ra</strong>l Silicone free ABS wall/field mount enclosure IP65with EPDM and PE sealings. UV-resisi<strong>ta</strong>nt polyes<strong>te</strong>rkeypad (old HD enclosure).Dimensions 130 x 114 x 71mm (5.1" x 4.5" x 2.8") - W x H x D.Weight 450 gr.Type HS Cable entry: no holes.10F111


Signal <strong>input</strong>sFlowme<strong>te</strong>rType P Coil / sine wave (minimum 20mVpp or 80mVpp -sensitivity selec<strong>ta</strong>ble), NPN/PNP, open collec<strong>to</strong>r, reedswitch,Namur, active pulse signals 8 - 12 and 24V DC.Frequency Minimum 0Hz - maximum 7kHz for <strong>to</strong><strong>ta</strong>l and <strong>flow</strong> <strong>ra</strong><strong>te</strong>.Maximum frequency depends on signal type andin<strong>te</strong>rnal low-pass fil<strong>te</strong>r. E.g. reed switch withlow-pass fil<strong>te</strong>r: max. frequency 120Hz.K-Fac<strong>to</strong>r 0.000010 - 9,999,999 with variable decimal position.Low-pass fil<strong>te</strong>r Available for all pulse signals.Option ZF coil sensitivity 10mVpp.Type A(0)4 - 20mA. Analog <strong>input</strong> signal can be scaled <strong>to</strong> anydesired <strong>ra</strong>nge within 0 - 20mA.Type U0 - 10V DC. Analog <strong>input</strong> signal can be scaled <strong>to</strong> anydesired <strong>ra</strong>nge within 0 - 10V DC.Accu<strong>ra</strong>cy Resolution: 14 bit. Error < 0.025mA / ± 0.125% FS.Low level cut-off prog<strong>ra</strong>mmable.Span0.000010 - 9,999,999 with variable decimal position.Up<strong>da</strong><strong>te</strong> time Four times per second.Vol<strong>ta</strong>ge drop Type A: 2.5V @ 20mA.Load impe<strong>da</strong>nce Type U: 3kΩ.Relationship Linear and square root calculation.No<strong>te</strong>For signal type A and U: ex<strong>te</strong>rnal power <strong>to</strong> sensor isrequired; e.g. type PD.Pulse outputFunctionFrequencyType OAType ORType OTSignal outputsPulse output - t<strong>ra</strong>nsmitting accumula<strong>te</strong>d <strong>to</strong><strong>ta</strong>l.Max. 64Hz. Pulse length user definable between7.8msec up <strong>to</strong> 2 seconds.two active 24V DC t<strong>ra</strong>nsis<strong>to</strong>r outputs (PNP);max. 50mA per output (requires PD, PF or PM).two electro-mechanical relay outputs - isola<strong>te</strong>d;max. switch power 230V AC (N.O.) - 0.5A per relay(requires PF or PM).two passive t<strong>ra</strong>nsis<strong>to</strong>r outputs (NPN) - not isola<strong>te</strong>d.Max. 50V DC - 300mA per output.Communication optionFunction Reading display information, reading / writing allconfigu<strong>ra</strong>tion settings.Pro<strong>to</strong>col Modbus ASCII / RTU.Speed1200 - 2400 - 4800 - 9600 baud.Addressing Maximum 255 addresses.Type CB RS232Type CH RS485 2-wireType CIRS485 4-wireType CT TTL Intrinsically Safe.Ope<strong>ra</strong>tionalOpe<strong>ra</strong><strong>to</strong>r functionsDisplayed • Flow <strong>ra</strong><strong>te</strong> and / or <strong>to</strong><strong>ta</strong>l <strong>flow</strong> A.functions • To<strong>ta</strong>l and accumula<strong>te</strong>d <strong>to</strong><strong>ta</strong>l <strong>flow</strong> A.• Flow <strong>ra</strong><strong>te</strong> and / or <strong>to</strong><strong>ta</strong>l <strong>flow</strong> B.• To<strong>ta</strong>l and accumula<strong>te</strong>d <strong>to</strong><strong>ta</strong>l <strong>flow</strong> B.• To<strong>ta</strong>l A and <strong>to</strong><strong>ta</strong>l B can indivi<strong>dual</strong>ly be reset <strong>to</strong> zeroby pressing the CLEAR-key twice.To<strong>ta</strong>lDigits7 digits.UnitsL, m 3 , GAL, USGAL, kg, lb, bbl, no unit.Decimals 0 - 1 - 2 or 3.No<strong>te</strong>To<strong>ta</strong>l can be reset <strong>to</strong> zero.Accumula<strong>te</strong>d <strong>to</strong><strong>ta</strong>lDigits11 digits.Units / decimals According <strong>to</strong> selection for <strong>to</strong><strong>ta</strong>l.No<strong>te</strong>Can not be reset <strong>to</strong> zero.Flow <strong>ra</strong><strong>te</strong>DigitsUnits7 digits.mL, L, m 3 , Gallons, kg, Ton, lb, bl, cf, RND, ft 3 , scf,Nm 3 , Nl, igal - no units.Decimals 0 - 1 - 2 or 3.Time units /sec - /min - /hr - /<strong>da</strong>y.AccessoriesMounting accessoriesACF02S<strong>ta</strong>inless s<strong>te</strong>el wall mounting kit.ACF05S<strong>ta</strong>inless s<strong>te</strong>el pipe mounting kit (worm gear clampsnot included).ACF06Two s<strong>ta</strong>inless s<strong>te</strong>el worm gear clamps Ø 44 - 56mm.ACF07Two s<strong>ta</strong>inless s<strong>te</strong>el worm gear clamps Ø 58 - 75mm.ACF08Two s<strong>ta</strong>inless s<strong>te</strong>el worm gear clamps Ø 77 - 95mm.ACF09Two s<strong>ta</strong>inless s<strong>te</strong>el worm gear clamps Ø 106 - 138mm.ACF10Cus<strong>to</strong>mized Grevopal <strong>ta</strong>gpla<strong>te</strong>s for ACF02 and ACF05,including s<strong>ta</strong>inless s<strong>te</strong>el screws.Dimension: 95mm x 12.5mm (3.75” x 0.50”).Cable gland accessoriesACF20For HA enclosure, includes O-rings.ACF25For HE enclosure, includes locknuts and O-rings.ACF26For HF enclosure, includes locknuts and O-rings.ACF27For HG enclosure, includes locknuts and O-rings.ACF28For HH enclosure, includes locknuts and O-rings.ACF29For HJ enclosure, includes locknuts and O-rings.ACF32For HM enclosure, includes O-rings.ACF33For HN enclosure, includes O-rings.ACF34For HO enclosure, includes O-rings.ACF35For HP enclosure, includes O-rings.ACF39For HT enclosure, includes O-rings.ACF40For HU enclosure, includes O-rings.Blind plug accessoriesACF50For HA enclosure, includes O-rings.ACF55For HE enclosure, includes locknuts and O-rings.ACF56For HF enclosure, includes locknuts and O-rings.ACF57For HG enclosure, includes locknuts and O-rings.ACF58For HH enclosure, includes locknuts and O-rings.ACF59For HJ enclosure, includes locknuts and O-rings.ACF62For HM enclosure, includes O-rings.ACF63For HN enclosure, includes O-rings.ACF64For HO enclosure, includes O-rings.ACF65For HP enclosure, includes O-rings.ACF69For HT enclosure, includes O-rings.ACF70For HU enclosure, includes O-rings.F11111


Ordering informationS<strong>ta</strong>n<strong>da</strong>rd configu<strong>ra</strong>tion: F111-P-AX-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F111 -_ -AX -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Flowme<strong>te</strong>r <strong>input</strong> signalA (0)4 - 20mA <strong>input</strong>.P Pulse <strong>input</strong>: coil, npn, pnp, namur, reed-switch.U 0 - 10V DC <strong>input</strong>.Analog output signalAX No analog output.CommunicationCB Communication RS232 - Modbus ASCII / RTU.CH Communication RS485 - 2-wire - Modbus ASCII / RTU.CI Communication RS485 - 4-wire - Modbus ASCII / RTU.CT Intrinsically Safe TTL - Modbus ASCII / RTU.CX No communication.Flow equationsEX No <strong>flow</strong> equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.HF Cable entry: 1 x Ø 22mm ( 7 /8”).HG Cable entry: 2 x Ø 20mm.HH Cable entry: 6 x Ø 12mm.HJ Cable entry: 3 x Ø 22mm ( 7 /8”).HK Flat bot<strong>to</strong>m, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.HT Cable entry: 1 x 1 /2”NPT.HU Cable entry: 3 x 1 /2”NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).Additional <strong>input</strong>sIX No additional <strong>input</strong>.OutputsOA two active t<strong>ra</strong>nsis<strong>to</strong>r outputs - requires PD, PF or PM.OR Two mechanical relay outputs - requires PF or PM.OT Two passive t<strong>ra</strong>nsis<strong>to</strong>r outputs - s<strong>ta</strong>n<strong>da</strong>rd configu<strong>ra</strong>tion.Power supplyPB Lithium bat<strong>te</strong>ry powered.PC Lithium bat<strong>te</strong>ry powered - Intrinsically Safe.PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PL Input loop powered from sensor signal type “A” - requires OT.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply).Tempe<strong>ra</strong>ture <strong>input</strong> signalTX No <strong>te</strong>mpe<strong>ra</strong>ture <strong>input</strong> signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil <strong>input</strong> 10mVpp.ZX No options.The bold marked <strong>te</strong>xt con<strong>ta</strong>ins the s<strong>ta</strong>n<strong>da</strong>rd configu<strong>ra</strong>tion.Available Intrinsically Safe.Specifications are subject <strong>to</strong> change without notice.<strong>Klay</strong> <strong>Instruments</strong> bvNijverheidsweg 5, 7991 CZ, DwingelooP.O. box 13, 7990 AA, DwingelooThe NetherlandsTel.: +31 (0)521 591550Fax.: +31 (0)521 592046info@klay.nlwww.klay.nl12Copyright: Fluidwell bv - 2010 - KLAY-DSF111-0910-EN

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!