ADDITIONAL GROUND CONNECTIONS:To ensure proper system grounding the following additional connectionsmust be made. RCA Shields & <strong>SEQ</strong> case must be connected to case ofsource unit.RCA Shields -<strong>SEQ</strong> Case -Signal Ground from amplifier inputs (connect wire fromRCA Shields @ amplifier input to case of source unit)*Case Ground from <strong>SEQ</strong>(connect wire from <strong>SEQ</strong> case to case of source unit)** Four separate wires should terminate under the same screw at thecase of the source unit.**Preferably, this connection is made through a 1/4 amp, fast blow, fusedirectly to the car battery.Connecting the <strong>SEQ</strong>The <strong>SEQ</strong> has a special miniature circular 7 pin connector with goldplated pins. The connector snaps into place like other high qualityconnectors. To remove it, squeeze and then pull as shown:Don’t turn - Don’t twist - Don’t use hand tools!1. Squeeze finger grips to flex plastic coupling area. The locking tabswill deflect outward and unlock.2. Pull plug from receptacle.5