3.1.7 Buildings designed for low temperature<br />
heating and high temperature cooling<br />
The buildings themselves are designed to have a low<br />
heating and cooling demand. Specifically, this involves<br />
constructing the buildings with very good thermal<br />
insulation and small ventilation losses, integrating<br />
mechanical ventilation with heat recovery, and limiting<br />
summer solar gains by means of effective shading. The<br />
characteristics of the buildings are summarised in Table 3.3.<br />
Limiting the heating and cooling demands in this way means<br />
that most of the remaining demand can theoretically be<br />
met by low exergy sources (this means heat demand is<br />
met by means of a low temperature heat supply, and the<br />
cooling demand by a high temperature cooling supply). It<br />
w<strong>as</strong> estimated that the mine <strong>water</strong> from different depths<br />
at Heerlen can be used to contribute significantly to these<br />
demands with only small temperature increments (and hence<br />
energy) required from supplementary systems.<br />
Table 3.3: Characteristics of buildings designed for low temperature heating and high temperature cooling<br />
Building Regulation NL Practice 2007 NL <strong>Mine</strong> <strong>water</strong> Lowex<br />
Thermal insulation<br />
Envelope Rc = 2.5<br />
Glazing U = 3.0<br />
Ventilation<br />
No system requirements<br />
Air tightness<br />
qv 10 < 200 (n50 = 3)<br />
Emission system<br />
No requirements<br />
HVAC system/efficiency<br />
No requirements (but in EPR)<br />
EPC dwellings<br />
0.8<br />
Heerleheide<br />
EC<br />
HH1<br />
24ºC<br />
Fig 3.5: Schematic view of the energy concept<br />
Thermal insulation<br />
Envelope Rc = 3.0<br />
Glazing U = 1.5<br />
Ventilation<br />
50% ME/50% MVHR<br />
Air tightness<br />
qv 10 = 100..150<br />
Emission system<br />
Radiators<br />
HVAC system/efficiency<br />
Condensing boilers<br />
Efficiency = 95%<br />
No cooling<br />
EPC dwellings<br />
0.8<br />
Thermal insulation<br />
Envelope Rc = 4.0<br />
Glazing U = 1.2<br />
Ventilation<br />
MVHR efficiency = 95%<br />
Air tightness<br />
qv 10 < 62.5 (n50