12.07.2015 Views

SASY 60i Busbar System

SASY 60i Busbar System

SASY 60i Busbar System

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SASY</strong> <strong>60i</strong> <strong>Busbar</strong> <strong>System</strong>NZM <strong>Busbar</strong> Adaptor, 3-pole 1) , for Copper Bars 12 - 30 x 5/10, Double-T-ProfileVT16206<strong>Busbar</strong> Adaptor NZM• NZM1-XAD160:For switches with standard connection frame-typeterminals. To be snapped onto the busbar by meansof a combi-base.Adaptor Length 200 mmSpecial Features: for connecting to the system at thetop through fixed connection bars included in thescope of delivery 2)• NZM2-XAD250:Use only in combinatiion with the auxiliary type(+)NZM2-XKR4. To be screwed onto the busbar bymeans of a claw-type of clamp.Adaptor Length 190 mmSpecial Features: For connecting to the system at thetop/bottom through a tubetype of connection at therear. Tube included in the scope of delivery.• NZM3-XAD550:Use only in combination with the a uxiliary type(+)NZM3-XKR13. To be screwed onto the busbar bymeans of a claw-type of clamp.Adaptor Length 270 mmSpecial Features: For connecting to the system at thetop through a tube-type connection at the rear. Tubeincluded in the scope of delivery.• Rated Operating Voltage 690 VVT17706Max. Adaptor Utilisation Designation Article No. UnitsRated Width per PackageOper. Current x LengthI e [A][mm]160 90 x 200 NZM1 NZM1-XAD160 104554 1PMC1PSC1PN1N1NS1VT17606250 106 x 190 NZM2 NZM2-XAD250 104555 1PMC2PSC2PN2N2NS2550 140 x 270 NZM3 NZM3-XAD550 104556 1PMC3PSC3PN3N3Terminal Space Cover NZM• NZM2-XKR4:For device combination NZM2 use with theauxiliary type +NZM2-XKR4O or +NZM2-XKR4USpecial Features: to cover the connection to thesystem at the top/bottom• NZM3-XKR13:For device combination NZM3 use with the auxiliarytype NZM3-XKR13OSpecial Features: to cover the connection to thesystem at the top• Rated Operating Voltage 690 VMax. Adaptor Utilisation Designation Article No. UnitsRated Width per PackageOper. CurrentI e [A][mm]VT18706250 – NZM2 NZM2-XKR4 281666 1PMC2PSC2PN2N2NS2550 – NZM3 NZM3-XKR13 281668 1PMC3PSC3PN3NTechnical data page 281) To be snapped onto the voltage-free busbar.2) Thanks to the combi-base it can be adjusted to a bar width of both 5 and 10 mm, cross-section of conductor 6 x 9 x 0.8.17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!