Transmitter Sens NH3-1000-HL Article-No.: 211204 Features ...

Transmitter Sens NH3-1000-HL Article-No.: 211204 Features ...

Transmitter Sens NH3-1000-HL Article-No.: 211204 Features ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Transmitter</strong> <strong>Sens</strong> <strong>NH3</strong>-<strong>1000</strong>-<strong>HL</strong><strong>Article</strong>-<strong>No</strong>.: <strong>211204</strong>105 mm 65 mm138 mm<strong>Features</strong>Measured Gas : Ammonia (NH 3 )Measuring Range: 0 to <strong>1000</strong> ppmMeasuring Principle: SemiconductorOperation Temperature : -25 °C to +50 °CHumidity: 10 r. H. to 95 r. H. (Please avoid condensation)Pressure: 900 hPa to 1100 hPaResponse Time t 90 : 120 sMechanical <strong>Features</strong>Dimensions: 138 mm x 105 mm x 65 mm (Length x Width x Height)Weight: approx. 0.5 kgMaterial: Cast aluminium (lacquered) / stainless steelEnclosure Rating: IP 54 (with the exception of gas inlet)Installation: Wall mounting, installation in pipes with adaptor (optional)Storage Temperature : -25 °C to +60 °CElectrical <strong>Features</strong>Power Supply: 24 ± 6 V DCPower Consumption: 80 mA / 2 WInterface : 4-20 mA (linear)Max. Load: 500 ΩCable Gland: M 16 x 1.5 (diameter of cable 5-9 mm)ConformityEC-Directives : 89/336/EEC (EMC)Measuring Function : Designed according to EN 45544-1 to EN 45544-3ExTox GmbH ● Hildebrandstraße 5 ● D-44319 Dortmund ● Tel. +49 231 589 409-0 ● Fax +49 231 589 409-10Internet: www.extox.de ● mail to: info@extox.de<strong>Sens</strong>_<strong>NH3</strong>-<strong>1000</strong>-<strong>HL</strong>_<strong>211204</strong>_e_V5.doc,03/06/2004,Seite 1 von 2


<strong>Transmitter</strong> <strong>Sens</strong> <strong>NH3</strong>-<strong>1000</strong>-<strong>HL</strong><strong>Article</strong>-<strong>No</strong>.: <strong>211204</strong>InstallationPlace: When monitoring working place concentrations installation at eyelevel,otherwise near to the floor or close to sources of release.Position : sensor opening to be placed downwardsFixing : drilling jig as Download on our ExTox HomepageTerminal Assignment :4-20 mAGNDU+U+ Power supply 24 VGND Ground (Power supply and current output)4-20 mA Current output 4-20 mALine Length : max 1,000 m when using ExTox-Cable 3 x 0.8 mm(corresponds to a wire resistance of 9 Ω)Time of Stabilisation : approx. 10 min (90%), approx. 12 h (99%)UseDescription of the MeasuringPrinciple: A chemisorption of the measured gas takes place at the heatedsurface of a semi-conducting metal oxide. With that the metal oxidelayer changes its electrical conductivity depending on theconcentration of measured gasCross <strong>Sens</strong>itivity : ▪ Semiconductor sensors react upon every type of flammablegases and vapours as well as upon other gases, such as forexample some refrigerants. The relative sensitivity variesdepending on gas type.▪ Hydrogen leads to a clear measuring signal even at ppmconcentrations.▪ Reducing gases, such as NO 2 could cause negative measuringsignals.Special Influences : ▪ Considerable changes of humidity or of the oxygen contentshould be avoided.▪ Alarm levels from 50 ppm to approx. 500 ppm▪ Lower limit of measuring range 25 ppm (acc. to EN 45544)<strong>Sens</strong>or Lifetime : typical: 2-5 years, depending on operation conditionsMaintenanceIntervals : Minimum every half year.We recommend to keep EN 45544-4 and national regulations (orGerman BG Chemie-Information BGI 836)Test Gas (Zero Point) : Ambient air (free from measured gas) or synthetic air (moistened)Test Gas (<strong>Sens</strong>itivity) : Ammonia in air (moistened),Concentration in the middle of measuring range or slightly abovehighest alarm levelTest Gas Application: 0.5 to 1 l/min by means of ExTox-Calibration Adapter for minimum180 s<strong>Sens</strong>or Element,<strong>Article</strong> <strong>No</strong>. 620013ReplacementFurther Information : EN 45544-4, BG Chemie-Information BGI 836 (German version only)This Data Sheet is at the same time a type specific supplementto the Instruction Manual ExTox <strong>Transmitter</strong> Ex<strong>Sens</strong>/<strong>Sens</strong>.(Subject to technical change)ExTox GmbH ● Hildebrandstraße 5 ● D-44319 Dortmund ● Tel. +49 231 589 409-0 ● Fax +49 231 589 409-10Internet: www.extox.de ● mail to: info@extox.de<strong>Sens</strong>_<strong>NH3</strong>-<strong>1000</strong>-<strong>HL</strong>_<strong>211204</strong>_e_V5.doc,03/06/2004,Seite 2 von 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!