12.07.2015 Views

SAVE VTR 150/K & 200/B - Systemair

SAVE VTR 150/K & 200/B - Systemair

SAVE VTR 150/K & 200/B - Systemair

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Fans | Air handling units | Air distribution products | Fire safety | Air curtains and heating products | Tunnel fans<strong>SAVE</strong> <strong>VTR</strong> <strong>150</strong>/K & <strong>200</strong>/BResidential air handling units


2 | <strong>SAVE</strong> <strong>VTR</strong> <strong>150</strong>/K, <strong>200</strong>/B<strong>SAVE</strong> <strong>VTR</strong> <strong>150</strong>/K, <strong>200</strong>/BNew ventilation system for smaller dwellings• High efficient rotary heat exchanger• Energy efficient Radical-fans, withmodern EC-technology• Separate settings of supply andextract air flow• Start-up wizard for easy commissioning• Modern design with integratedcooker hood – <strong>VTR</strong> <strong>150</strong>/K• Automatic change to summer operation(without heat recovery)• Demand control regulation• Low sound levelThe new air handling units <strong>SAVE</strong> <strong>VTR</strong><strong>150</strong>/K and <strong>SAVE</strong> <strong>VTR</strong> <strong>200</strong>/B fulfillthe high demands on the marketon low energy consumption andsound levels. The EC technologyensure the fans are energy efficientand contribute to a low SFPvalue. The rotary heat exchangeroperates at a high efficiency at anycondition. The units are operatedand monitored by a modern controlsystem and the status of the unitcan easily be surveyed.<strong>SAVE</strong> <strong>VTR</strong> <strong>150</strong>/K has an integratedcooker hood and should be placedabove the hob. The unit has beenadapted to suit different kitchenenvironments, with a modern design.The customer has the oportunity tochoose between a white or stainlesssteel front. The unit is regulated by aseparate control panel.<strong>SAVE</strong> <strong>VTR</strong> <strong>200</strong>/B is a white paintedmodel with an integrated controlpanel in the front door. The optionfor connecting one or more externalcontrol panels is also available. Connectionto an external cooker hood isavailable on the top of the unit. Thismakes the unit well suited for apartmentbuildings where the extract airfrom the cooker hood is challenging<strong>SAVE</strong> <strong>VTR</strong> <strong>150</strong>/K and <strong>SAVE</strong> <strong>VTR</strong><strong>200</strong>/B is adapted for ventilation ofsmaller houses and apartments withan area of 100 m² and 140 m². Theextract air from the cooker hood isby-passed, hence the heat exchangeris not being exposed to extract airfrom the kitchen. The units are insulatedagainst condensation.With the release of <strong>SAVE</strong> <strong>VTR</strong> <strong>150</strong>/Kand <strong>SAVE</strong> <strong>VTR</strong> <strong>200</strong>/B, <strong>Systemair</strong> israising the quality of ventilation forresidential buildings.


SFP 2,5SFP 2,0SFP 1,5SFP 1,2SFP 1,2<strong>SAVE</strong> <strong>VTR</strong> <strong>150</strong>/K, <strong>200</strong>/B | 3Supply airExtract airSFP 2,5SFP 2,0SFP 1,5<strong>SAVE</strong> <strong>VTR</strong> <strong>150</strong> right hand version470**)598*)348<strong>SAVE</strong> <strong>VTR</strong> <strong>200</strong> right hand version59842836671027501331911247720759834020878160198285428CVVXkombi grilleLDCsilencerIGKwall gridVBC 1180heating battery598CDcontrol panel416774720799*)incl. door596191 29384 99237**)incl bracket*)29Supply air627Exhaust airOutdoor airExtract airConnection dim.: Ø125* extract air from cooker hood982*


www.systemair.com<strong>Systemair</strong> · In house studio · November 2012 · E8228

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!