12.07.2015 Views

NM230-F Form-fit damper actuator 8 Nm - Belimo

NM230-F Form-fit damper actuator 8 Nm - Belimo

NM230-F Form-fit damper actuator 8 Nm - Belimo

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

NM24-F <strong>Form</strong>-<strong>fit</strong> <strong>damper</strong> <strong>actuator</strong> 8 <strong>Nm</strong>2. NM/E2-2Dampers up to approx. 1.5m 2Open/Close <strong>actuator</strong>(AC/DC 24V)ReversibleImproved functional safetyThe <strong>damper</strong> <strong>actuator</strong> has no limit switchesand is overload-proof. It stops automaticallywhen it reaches the <strong>damper</strong> or<strong>actuator</strong> end stop.p0023707Easy functional checkA functional check of <strong>damper</strong> operation issimplicity itself: the gearing can be disengagedby simply pressing a pushbuttonon top of the case. While the pushbuttonremains depressed, the <strong>damper</strong> can beoperated by hand.Wiring diagramSimple installationThe NM24-F, with its hollow shaft, isplaced over the 8mm square spindle ofthe <strong>damper</strong> and secured by two screws.Single-wire controlT~- +AC 24 VDC 24 V!Connect via safetyisolating transformer.2-wire controlAC 24 V- + DC 24 VT~Electrical accessoriesSN1, SN2 Auxiliary switchesImportantRead the notes about the use and torquerequirements of the <strong>damper</strong> <strong>actuator</strong>s onpage 3 in the documentation 2. NM-….1 2 31 2 3NM24-FParallel connection of several<strong>actuator</strong>s is possible. Powerconsumption must be observed.NM24-Fw0507807Technical dataNM24-FNominal voltageAC 24V 50/60Hz, DC 24VNominal voltage range AC/DC 19.2...28.8 VFor wire sizing3.5 VAPower consumption 2 WConnecting cable 1m long, 3 x 0.75 mm 2Direction of rotation selected with L / R switchTorquemin. 8 <strong>Nm</strong> (at rated voltage)Angle of rotationmax. 95° (adjustable by mechanical stops)Running time75...150 s (0...8 <strong>Nm</strong>)Sound power level max. 35 dB(A)Position indicationmechanicalProtection classIII (safety low voltage)Degree of protection IP 54 (cable entry down)Ambient temperature range –20...+50 °CNon-operating temperature –40...+80 °CHumidity test to EN 60335-1Dimensions221554338 103 958EMCMaintenanceWeightCE according to 89/336/EEC and 92/31/EECmaintenance free800 g30d00148075.281


<strong>NM230</strong>-F <strong>Form</strong>-<strong>fit</strong> <strong>damper</strong> <strong>actuator</strong> 8 <strong>Nm</strong>Dampers up to approx. 1.5m 2Open/Close <strong>actuator</strong> (AC 230V)Control by single-pole contact(single-wire control)Improved functional safetyThe <strong>damper</strong> <strong>actuator</strong> has no limit switchesand is overload-proof. It stops automaticallywhen it reaches the <strong>damper</strong> or<strong>actuator</strong> end stop.p0024707Easy functional checkA functional check of <strong>damper</strong> operation issimplicity itself: the gearing can be disengagedby simply pressing a pushbuttonon top of the case. While the pushbuttonremains depressed, the <strong>damper</strong> can beoperated by hand.Wiring diagramAC 230 VN L1To isolate from the main power supply, the systemmust incorporate a device which disconnects the phaseconductors (with at least a 3 mm contact gap).Simple installationThe <strong>NM230</strong>-F, with its hollow shaft, isplaced over the 8mm square spindle ofthe <strong>damper</strong> and secured by two screws.Electrical accessoriesSN1, SN2 Auxiliary switchesImportantRead the notes about the use and torquerequirements of the <strong>damper</strong> <strong>actuator</strong>s onpage 3 in the documentation 2. NM-….1 2 3<strong>NM230</strong>-FParallel connection of several <strong>actuator</strong>swith 1-wire control is possible. Powerconsumption must be observed.w0508807Technical data<strong>NM230</strong>-FNominal voltageAC 230 V 50/60 HzNominal voltage range AC 198…264 VFor wire sizing18 VAPower consumption 2 WConnecting cable 1m long, 3 x 0.75 mm 2Direction of rotation selected with L / R switchTorqueAngle of rotationRunning timeSound power levelPosition indicationProtection classDegree of protectionAmbient temperature range –20...+50 °CNon-operating temperature –40...+80 °CHumidity test to EN 60335-1min. 8 <strong>Nm</strong> (at rated voltage)max. 95° (adjustable by mechanical stops)75...150 s (0...8 <strong>Nm</strong>)max. 35 dB(A)mechanicalII (all insulated)IP 54 (cable entry down)Dimensions221554338 103 958EMCMaintenanceWeightCE according to 89/336/EEC and 92/31/EECmaintenance free800 g30d00148075.281


Mounting instructions for <strong>Form</strong>-<strong>fit</strong> <strong>damper</strong> <strong>actuator</strong>s NM…-Fm0036807min. 10mm81 2ENG-93238-10.98 · Printed in Switzerland · ZSD · Subject to technical changes

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!