12.07.2015 Views

Condensing - Grant UK

Condensing - Grant UK

Condensing - Grant UK

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

General InformationInstallation and commissioningInstallation must comply with the current British Standards andThe Building Regulations. Comprehensive technical informationcan be found in the installation manual, supplied with everyboiler.As with all oil-fired appliances, <strong>Grant</strong> Vortex <strong>Condensing</strong>Boilers require commissioning at the time of installation.This simple process ensures that the boiler is workingat peak efficiency which, in turn, will result in lower runningcosts and long term reliability.Pluming<strong>Condensing</strong> boilers operate at extremely high efficiency levels,producing cool flue gas temperatures, resulting in a ‘plume’ ofvapour being visible at the flue terminal. This plume (steam) is anormal condition of condensing boiler operation and indicatesthat the appliance is working efficiently.Low level balanced, high level, or vertical flue kits are available,which moves the plume to a higher level. Alternatively, it ispossible to convert an existing low level balanced flue to anexternal high level or vertical arrangement using <strong>Grant</strong>’s PlumeDiverter.GuaranteesThe unique heat exchanger on <strong>Grant</strong> Vortex <strong>Condensing</strong> Boilersis covered by a 5-year guarantee. All other component parts ofthe boiler are guaranteed for 2 years from the date of purchase(excluding consumable items), subject to being installed inaccordance with the manufacturers instructions. There are alsooptional annual, or 3-year extended warranty schemes available.On completion of the installation all <strong>Grant</strong> Vortex <strong>Condensing</strong>Boilers must be commissioned and the guarantee registrationform completed online.After sales serviceFor peace of mind, all <strong>Grant</strong> central heating boilers are backedby a national network of independent service engineers. In theunlikely event of a problem occurring, your installer shouldtelephone our Customer Service Department on: 01380 736920Standard Assessment Procedure (SAP)SEDB<strong>UK</strong> was developed by the Government alongside boilermanufacturers, under their ‘Energy Efficiency Best PracticeProgramme’. It was designed as a fair basis for comparisons ofboiler energy performance when installed in a typical domesticsituation in the <strong>UK</strong>.To determine boiler efficiencies, a ‘Standard AssessmentProcedure’ more commonly known as SAP, is used. SAP is theGovernment’s standard method for energy rating. SAP ratingsenable the comparison of energy efficiencies and demonstrate thelikely effect of improvements to a property in terms of energy use.Since SEDB<strong>UK</strong> was introduced in 1999, it has undergone manychanges, the most recent being the move from SAP 2005 to SAP2009. The changes focus on improving the accuracy of the waythe efficiencies are worked out.SAP 2009 incorporates a key revision in the assumed carbonemissions per kWh of oil used by the boiler. It may appear that theefficiencies of boilers have reduced with SAP 2009, but it isimportant to understand that the new methodology gives a morerealistic estimate of the average annual boiler efficiency wheninstalled in typical conditions, based on evidence from recentindependent testing and field trials.FuelThe burner on all <strong>Grant</strong> Vortex boilers is supplied factory set at thestated output for use on standard grade kerosene - Class C2.<strong>Grant</strong> Vortex <strong>Condensing</strong> Boilers manufactured from May 2011onwards, however, will have a new ‘bio compatible’ burner fittedwhich is also suitable for biokerosene at a 30% blend, known asB30.To use B30 fuel, it will be necessary to change the oil feed line andensure that other components used during installation e.g oil tank,etc. are suitable. <strong>Grant</strong> Vortex <strong>Condensing</strong> Boilers must not beused with Class D gas oil.This leaflet is accurate at the time of printing but as <strong>Grant</strong> <strong>UK</strong> has a policy of continual improvement itmay be superseded. We reserve the right to amend specifications without prior notice. The statutoryrights of the consumer are not affected.All products manufactured under I.S. EN ISO 9001 and ISO 14001.THE GRANT ‘EZ-FIT FLUE’ SYSTEM is a Trade Mark of <strong>Grant</strong> Engineering Limited.®<strong>Grant</strong> Aerona, <strong>Grant</strong> Spira, <strong>Grant</strong> Vecta, <strong>Grant</strong> Vortex, <strong>Grant</strong> Solar, <strong>Grant</strong> Aurora, <strong>Grant</strong> Sahara,<strong>Grant</strong> CombiSOL, <strong>Grant</strong> WinterSOL, <strong>Grant</strong> MonoWave, <strong>Grant</strong> DuoWave, <strong>Grant</strong> ThermaWave,Euroflame and Multi Pass are registered trade marks of <strong>Grant</strong> Engineering Limited. The contents ofthis leaflet are fully protected by copyright and nothing may be reproduced without permission from<strong>Grant</strong> <strong>UK</strong>.GRANT ENGINEERING (<strong>UK</strong>) LTDHOPTON HOUSE, HOPTON INDUSTRIAL ESTATE,DEVIZES, WILTSHIRE, SN10 2EUT: 01380 736920 F: 01380 736991E: SALES@GRANT<strong>UK</strong>.COM W: WWW.GRANT<strong>UK</strong>.COMGRANTEZ FIT FLUE SYSTEMVCB 11/11 <strong>UK</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!