12.07.2015 Views

Programma SVERKER 750/760 Relay Test Sets - Surgetek

Programma SVERKER 750/760 Relay Test Sets - Surgetek

Programma SVERKER 750/760 Relay Test Sets - Surgetek

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Programma</strong><strong>SVERKER</strong> <strong>750</strong>/<strong>760</strong> <strong>Relay</strong> <strong>Test</strong> <strong>Sets</strong>Extra measurementsPower factor and phase angle measurementsRange Resolution AccuracyPower factor cos -0.99 (cap) to 0.01 ±0.04+0.99 (ind)Phase angle (°) 000 – 359° 1° ±2°Impedance and power measurementsACZ (Ω and °), Z (Ω), R and X (Ω and Ω), P(W), S (VA), Q (VAR)DCR (Ω), P (W)RangeUp to 999 kX (X= unit)Make/Break contactMax. current 1 AMax. voltage 250 V AC or 120 V DCReclosing testItems measuredDisplayTripping and reclosing timesAfter test is finished a list of all timesappears in displayBreaker state feedback The Make/Break contact can be used tofeed back the breaker stateMax. number of 49reclosingsMax. testing time999 s<strong>Sets</strong> of resistors and a capacitorResistors0.5 Ω to 2.5 kΩCapacitor 110µF, max voltage 450 V AC1- Measurement intervals longer than 100 ms. 2- <strong>SVERKER</strong> <strong>750</strong>OutputsCurrent outputs – ACRange No-load Full-load Full-load Load/unloadvoltage voltage current times(min) (min) (max) On (max)/Off (min)0 – 10 A 90 V 75 V 10 A 2/15 minutes0 – 40 A 25 V 20 V 40 A 1/15 minutes0 – 100 A 10 V 8 V 100 A 1/15 minutes0 – 100 A 10 V - 250 A 1 sec/5 minutesSpecifications Current and Voltage Source (CSU20A)Specifications are valid at nominal input voltage and an ambienttemperature of +25° C, (77° F). Specifications are subject tochange without notice.Operating temperature: -20° C to +50° C (-4° F to +122° F)Voltage:115 / 230 V AC, 50 / 60 HzThermal protection: Built-inDimensions: 280 x 178 x 246 mm (11” x 7” x 9.7”)Weight:5.9 kg (13 lbs) excl. transport caseCurrent measurements: Current shunt 0.1 A/1 V, ±2%Output, AC20 A setting Output voltage (min) Load timeIdle/non-load 26 V Continuous5 A 25 V Continuous10 A 22 V Continuous20 A 18 V 2 min10 A setting Output voltage (min) Load timeIdle/non-load 52 V Continuous3 A 50 V Continuous5 A 47 V Continuous10 A 41 V 10 minOutput, DCDC currentAs above, less the voltage dropover the rectifying diodesSpecifications Phase Selector Switch (PSS<strong>750</strong>)Specifications are valid at nominal input voltage and an ambienttemperature of +25° C, (77° F). Specifications are subject tochange without notice.Max input voltage 250 V AC / 3 AMax input currentMax resistor loading6 A / 250 V AC200 V AC / 200 mA(0.5 A during 5 seconds)Dimensions 200 x 120 x 85 mm (7.9” x 4.7” x 3.3”)Weight1.3 kg (2.9 lbs)Voltage outputs – AC/DCRange No-load Full-load Full-load Load/unloadvoltage voltage current times(min) (min) (max) On (max)/Off (min)0 – 250 V AC 290 V AC 250 V AC 3 A 10 min/45 min0 – 300 V DC 320 V DC 250 V DC 2 A 10 min/45 minSeparate AC voltage source<strong>SVERKER</strong> <strong>750</strong>Range No-load Full-load Full-loadvoltage voltage current(min) (min) (max)0 – 60 V AC 70 V 60 V 0.25 A60 – 120 V AC 130 V 120 V 0.25 ABoth ranges are divided into voltage steps of 10 V that aresteplessly variable.<strong>SVERKER</strong> <strong>760</strong>Range No-load Full-load Full-loadvoltage voltage current(min) (min) (max)0 – 130 V AC 140 V 130 V 0.25 A cont.0.35 A, 1 minutePhase angle Resolution Inaccuracy0 – 359° 1° ±2°Auxiliary DC outputRange Voltage Max. current20 – 130 V DC 20 V DC 130 V DC 300 mA400 mA130 – 220 DC 130 V DC 220 V DC 235 mA400 mAPhase Selector Switch (PSS<strong>750</strong>)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!