13.07.2015 Views

MDP Series Megger Distribution Profilers - Surgetek

MDP Series Megger Distribution Profilers - Surgetek

MDP Series Megger Distribution Profilers - Surgetek

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MDP</strong> <strong>Series</strong><strong>Megger</strong> <strong>Distribution</strong> <strong>Profilers</strong>APPLICATIONSThe <strong>Profilers</strong> are quickly installed at any point on thedistribution line. An arrow on the back of the <strong>MDP</strong> unitshould point towards the load. Since all units aremechanically identical and weigh less than 4.6 lbs (2.1 kg),they are easily mountable to many readily available clampsticks for installation on live lines. Cable diameters from0.2 in. to 1.2 in. (.5 cm to 3.0 cm) can be accommodated.The <strong>Profilers</strong> are quickly installed at any point on thedistribution line and are mountable to many readilyavailable clamp sticksFEATURES AND BENEFITS■ Virtually unlimited data recording — Depending onthe RMS storage interval selected, the Profiler can recordfor days, weeks, or even months. The unit offersvirtually unlimited data recording/storage capacity withno potential loss, even with battery failure.■ Wide range of data recording options — Recordnecessary data ranging from a simple survey study to acomplete circuit analysis including conductor sizing andcapacitor placement.■ Effective performance and protection — EachProfiler performs effectively when in direct exposureto all weather conditions. The molded unit offersthe greatest protection against water ingress, a majorissue encountered by power utilities using other linerecording devices.■ Easy battery replacement and plug-in access —Lightweight, durable unit with simple plug-in access andtrouble-free battery replacement.■ Easy installation — The light weight of the Profilerallows for quick and easy installation on live lines. It iseasily mountable to many readily available clamp sticks.SPECIFICATIONSAll specifications at 25° C unless otherwise specifiedConductor Size0.2 in. to 1.2 in. (.5 cm to 3.0 cm) cable outside diameterCurrent Range10 to 1000 Amps: 1% ± 2AConductor Voltage4 kV to 35 kVData Retention10 years with no powerReal Time Clock Accuracy0.005% over one yearOperational Temperature-40º F to +140º F (-40° C to +60° C)Storage Temperature-58º F to 185º F (-50° C to +85° C)Operating Humidity0 to 90% noncondensingStorage Humidity0 to 95% noncondensingAccuracyHarmonics analyzed out to the 32nd harmonicCurrent accuracy: ±1% of reading ±2 AElectric field accuracy: relative voltagePhase angle accuracy, low ranges: ±1% from 50 to 200 A,±2% from 10 to 50 APhase angle accuracy, high ranges: ±1% from 200 to 1000 A,±2% from 50 to 200 ACurrent THD accuracy, low ranges: 10 to 25 A ±5%25 to 40 A ±2%>40 A ±1%Current THD accuracy, high ranges: 10 to 20 A ±10%20 to 50 A ±5%50 to 80 A ±2%>80 A ±1%Voltage THD accuracy: >4000 V ±1%Frequency Range40 Hz to 2 kHzFundamental Frequencies50 Hz to 60 HzSample Rate128 samples/cycleStatistics StoredRMS current, electric field values, waveform data, internal batteryInput Power6 V dc to 30 mA MAXCommunicationsAll <strong>MDP</strong>s have both a standard high speed USB 2.0 channel and aconventional RS-232 serial data channel for legacy computersMemoryStorage Capacity: 8 Meg flashData Storage Modes: stop when memory full or wrap aroundEMFIEC61326:2002SafetyIEC61010Min. Distance between Conductors (lines) or Units3 ft (914 mm)EncapsulationWeatherproof/UV stableBatteryAny 4 commercial “AA” batteries. For extended temperatureapplications (below 0º and above +40º C) Lithium high range“AA” batteries are recommendedPhysicalDimensions: 12 H x 5 L x 3 W in. (30 H x 13 L x 8 W cm)Weight: 4.6 lbs (2.1 kg)


<strong>MDP</strong> <strong>Series</strong><strong>Megger</strong> <strong>Distribution</strong> <strong>Profilers</strong><strong>MDP</strong> METROSOFT ® SOFTWAREA new version of Metrosoft has been designed for usewith these <strong>Profilers</strong>. This newest version of Metrosoft iscompletely menu-driven and includes many powerfulfeatures. The new Metrosoft is compatible with the new<strong>MDP</strong> and other older <strong>Megger</strong> <strong>Distribution</strong> <strong>Profilers</strong>,allowing customers with legacy units to view old data filesusing the newest software.Software FeaturesThis software offers many powerful features specificallydesigned to save time. Features include:■ Easy, fill-in-the-form instrument setup and configuration■ Data retrieval from up to 4 <strong>Profilers</strong> at a specific site,merged into one data file■ Specific data file location using the integrated searchfunction■ Voltage/current and demand data chart access■ Harmonic and waveform analysis■ Individual harmonics, THD, frequency andimbalance charting■ Zoom/unzoom on specific graphical areas of interest■ Several built-in analysis reportsQuick Recorder SetupWith Metrosoft, all <strong>Profilers</strong> can be set up for different testconditions in a matter of seconds. By simply filling in aform, you choose which parameters will be recorded.Parameters include current, voltage, phase angle,waveform capture, response interval and storage interval.The software is smart enough to know what the specific<strong>MDP</strong> is capable of measuring and will automatically limitthe configurations available. A unique scheduled runfeature allows the <strong>Profilers</strong> to be pre-set to automaticallystart recording and then stop recording at specified datesand times.As an added convenience, the software computes therecording time, based on the selections made.Harmonic AnalysisThis new software also graphically charts and reportsharmonic data including:■ Charts of actual waveforms recorded■ Bar Chart of the harmonics magnitude and signature forany selected waveform cycle through the 32nd harmonic■ Harmonic Analysis Report for the selected waveformcycle■ Harmonic Trending – Total Harmonic Distortion(THD) and all individual harmonic voltages andcurrents through the 32nd orderCreate Detailed ReportsMetrosoft provides comprehensive reports of all recordeddata which can be viewed, printed, or exported as textfiles.■ Summary and Setup Report lists the instrument setupinformation and overall data summaries.■ Tabular Report: Power – includes all power recordedfor each phase and total.■ Tabular Report: Voltage and Current – includes alltrended true RMS values throughout the test.■ Total Harmonic Distortion (THD) Summary Reportincludes the THD for each input as a percentage offundamental for the first cycle of each waveformcapture snap shot.Chart Load Profiles and Identify ProblemsMetrosoft allows you to generate graphical chartpresentations of all measured values, providing loadprofiles for the entire test in one graph. Power trends andpossible network problems are quickly identified. Evenview load profiles from several different locationssimultaneously. This is a very useful tool for comparingmagnitude against power factor.An exceptional graphing feature is the ability to zoom-inand enlarge specific time periods of the graph for a closerlook. A scan line feature lets you move a line across thegraph and the software instantly displays the values for thespecific date/time on the graph. This gives you exactnumbers and eliminates the need to approximate. Allgraphs can be printed out for hard copy reports on anyprinter supported by Windows.


<strong>MDP</strong> <strong>Series</strong><strong>Megger</strong> <strong>Distribution</strong> <strong>Profilers</strong>Following are a few of the charts (waveform, bar) that you can access using the <strong>MDP</strong> Metrosoft software.RMS CurrentHarmonics Analysis Bar ChartTotal Harmonic DistortionWaveform


<strong>MDP</strong> <strong>Series</strong><strong>Megger</strong> <strong>Distribution</strong> <strong>Profilers</strong>PARAMETERS MEASURED<strong>MDP</strong>1 <strong>MDP</strong>2 <strong>MDP</strong>3Recording controlsStorage Interval 2 sec to 6 hours 2 sec to 6 hours 2 sec to 6 hoursResponse Interval 10 to 60 cycles 10 to 60 cycles 10 to 60 cyclesValues RecordedCurrent MeasurementRange 10-200 / 200-1000 10-200 / 200-1000 10-200 / 200-1000A to D Resolution Low Range 0.165703125 0.165703125 0.165703125A to D Resolution Low Range 0.828515625 0.828515625 0.828515625Recorded Resolution 1 A 1 A 1 ACurrent Accuracy 1% ± 2 A 1% ± 2 A 1% ± 2 AVoltage None Relative RelativeVoltage Range NA 4 kV to 35 kV 4 kV to 35 kVPhase Angle None Yes YesResolution NA 0.1º 0.1ºAccuracy 10-50 A NA 2% 2%Accuracy >50 A NA 1% 1%PowerNoneKW NA Yes YesKVAR NA Yes YesKVA NA Yes YesPF NA Yes YesOther Values RecordedWaveform Capture None None YesTHD None None YesHarmonic Analysis None None YesImbalance Yes Yes YesInternal Battery Voltage Yes Yes YesRS-232USB CableBattery ConnectionEasy plug-in access allows for quick data retrieval viaRS-232 and USB cable ports. The battery compartment isspecifically designed for simple removal and installationStarter Kit shown consists of 3 <strong>MDP</strong> <strong>Profilers</strong>, ac adapter,nylon carrying case, Phase ID label kit, RS-232/com port cable,USB cable,“AA” batteries, Metrosoft software, and instruction manual<strong>MDP</strong> with battery pack removed


<strong>MDP</strong> <strong>Series</strong><strong>Megger</strong> <strong>Distribution</strong> <strong>Profilers</strong>ORDERING INFORMATIONItem (Qty)Single Channel 1000 Amp <strong>Distribution</strong> ProfilerCE approved; isolated, single channel recordingProfiler for distribution line primary up to 35 kV ac.Hot-stick mountable. Unit records time stampedvalues of current magnitude with 1 amp resolutionfor days, weeks or months depending upon datastorage interval. True RMS through the50th harmonic.Single Channel 1000 Amp <strong>Distribution</strong> ProfilerCE Approved; same as <strong>MDP</strong>1 in addition torecording relative voltage RMS magnitude,power factor and powerSingle Channel 1000 Amp <strong>Distribution</strong> ProfilerCE approved; same as <strong>MDP</strong>1 in addition torecording RMS magnitude and waveformcapture, relative voltage RMS magnitude andwaveform capture, power factor and power,harmonics and THDNote: An RS-232 computer interface cable or USB cableand AC adapter are required for individual units.Cat. No.<strong>MDP</strong>1<strong>MDP</strong>2<strong>MDP</strong>3Item (Qty)Cat. No.Options and AccessoriesBattery holder 36164RS-232/com port cableCA-RS232Nylon carrying case for up tothree <strong>Profilers</strong> and accessories 36133Phase ID label kit; includes 2 sets of 3 labels,Alpha A, B & C / Numeric 1, 2 & 3 35863USB 2.0 A-B cableCA-USB"AA" battery (4 required) 23415Metrosoft Software for Windows 32-bit applicationssoftware for IBM and compatible computers.Programs unit, provides data retrieval, generates graphs,reports and data files, compatible with Excel software,and saves recorder setup files. Compatible withWindows NT, WIN2000 and XP 36175-1Instruction manualAVTM<strong>MDP</strong>Starter KitsConsists of 3 <strong>MDP</strong>1 <strong>Profilers</strong>, (1) AC adapter,(1) nylon carrying case, Phase ID label kit,(1) RS-232/com port cable, (1) USB 2.0 A-B cable,(12) “AA” batteries, Metrosoft software,(1) instruction manual SK-<strong>MDP</strong>1Same as SK-<strong>MDP</strong>1 except includes3 <strong>MDP</strong>2 <strong>Profilers</strong> instead of <strong>MDP</strong>1 <strong>Profilers</strong> SK-<strong>MDP</strong>2Same as SK-<strong>MDP</strong>1 except includes 3<strong>MDP</strong>3 <strong>Profilers</strong> instead of <strong>MDP</strong>1 <strong>Profilers</strong> SK-<strong>MDP</strong>3UKArchcliffe Road, DoverCT17 9EN EnglandT +44 (0) 1 304 502101F +44 (0) 1 304 207342UKsales@megger.comUNITED STATES4271 Bronze WayDallas, TX 75237-1019 USAT 1 800 723 2861 (USA only)T +1 214 333 3201F +1 214 331 7399USsales@megger.comOTHER TECHNICAL SALES OFFICESNorristown USA, Sydney AUSTRALIA,Toronto CANADA, Trappes FRANCE,Kingdom of BAHRAIN, Mumbai INDIA,Johannesburg SOUTH AFRICA, andConjure THAILANDISO STATEMENTRegistered to ISO 9001:2000 Cert. no. 10006.01<strong>MDP</strong>_DS_en_V01www.megger.com<strong>Megger</strong> is a registered trademark

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!