12.07.2015 Views

Programma SVERKER 750/760 Relay Test Sets - Surgetek

Programma SVERKER 750/760 Relay Test Sets - Surgetek

Programma SVERKER 750/760 Relay Test Sets - Surgetek

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Programma</strong><strong>SVERKER</strong> <strong>750</strong>/<strong>760</strong> <strong>Relay</strong> <strong>Test</strong> <strong>Sets</strong>Extra measurementsPower factor and phase angle measurementsRange Resolution AccuracyPower factor cos -0.99 (cap) to 0.01 ±0.04+0.99 (ind)Phase angle (°) 000 – 359° 1° ±2°Impedance and power measurementsACZ (Ω and °), Z (Ω), R and X (Ω and Ω), P(W), S (VA), Q (VAR)DCR (Ω), P (W)RangeUp to 999 kX (X= unit)Make/Break contactMax. current 1 AMax. voltage 250 V AC or 120 V DCReclosing testItems measuredDisplayTripping and reclosing timesAfter test is finished a list of all timesappears in displayBreaker state feedback The Make/Break contact can be used tofeed back the breaker stateMax. number of 49reclosingsMax. testing time999 s<strong>Sets</strong> of resistors and a capacitorResistors0.5 Ω to 2.5 kΩCapacitor 110µF, max voltage 450 V AC1- Measurement intervals longer than 100 ms. 2- <strong>SVERKER</strong> <strong>750</strong>OutputsCurrent outputs – ACRange No-load Full-load Full-load Load/unloadvoltage voltage current times(min) (min) (max) On (max)/Off (min)0 – 10 A 90 V 75 V 10 A 2/15 minutes0 – 40 A 25 V 20 V 40 A 1/15 minutes0 – 100 A 10 V 8 V 100 A 1/15 minutes0 – 100 A 10 V - 250 A 1 sec/5 minutesSpecifications Current and Voltage Source (CSU20A)Specifications are valid at nominal input voltage and an ambienttemperature of +25° C, (77° F). Specifications are subject tochange without notice.Operating temperature: -20° C to +50° C (-4° F to +122° F)Voltage:115 / 230 V AC, 50 / 60 HzThermal protection: Built-inDimensions: 280 x 178 x 246 mm (11” x 7” x 9.7”)Weight:5.9 kg (13 lbs) excl. transport caseCurrent measurements: Current shunt 0.1 A/1 V, ±2%Output, AC20 A setting Output voltage (min) Load timeIdle/non-load 26 V Continuous5 A 25 V Continuous10 A 22 V Continuous20 A 18 V 2 min10 A setting Output voltage (min) Load timeIdle/non-load 52 V Continuous3 A 50 V Continuous5 A 47 V Continuous10 A 41 V 10 minOutput, DCDC currentAs above, less the voltage dropover the rectifying diodesSpecifications Phase Selector Switch (PSS<strong>750</strong>)Specifications are valid at nominal input voltage and an ambienttemperature of +25° C, (77° F). Specifications are subject tochange without notice.Max input voltage 250 V AC / 3 AMax input currentMax resistor loading6 A / 250 V AC200 V AC / 200 mA(0.5 A during 5 seconds)Dimensions 200 x 120 x 85 mm (7.9” x 4.7” x 3.3”)Weight1.3 kg (2.9 lbs)Voltage outputs – AC/DCRange No-load Full-load Full-load Load/unloadvoltage voltage current times(min) (min) (max) On (max)/Off (min)0 – 250 V AC 290 V AC 250 V AC 3 A 10 min/45 min0 – 300 V DC 320 V DC 250 V DC 2 A 10 min/45 minSeparate AC voltage source<strong>SVERKER</strong> <strong>750</strong>Range No-load Full-load Full-loadvoltage voltage current(min) (min) (max)0 – 60 V AC 70 V 60 V 0.25 A60 – 120 V AC 130 V 120 V 0.25 ABoth ranges are divided into voltage steps of 10 V that aresteplessly variable.<strong>SVERKER</strong> <strong>760</strong>Range No-load Full-load Full-loadvoltage voltage current(min) (min) (max)0 – 130 V AC 140 V 130 V 0.25 A cont.0.35 A, 1 minutePhase angle Resolution Inaccuracy0 – 359° 1° ±2°Auxiliary DC outputRange Voltage Max. current20 – 130 V DC 20 V DC 130 V DC 300 mA400 mA130 – 220 DC 130 V DC 220 V DC 235 mA400 mAPhase Selector Switch (PSS<strong>750</strong>)


<strong>Programma</strong><strong>SVERKER</strong> <strong>750</strong>/<strong>760</strong> <strong>Relay</strong> <strong>Test</strong> <strong>Sets</strong>ORDERING INFORMATIONItem (Qty)<strong>SVERKER</strong> <strong>750</strong> 115 V Mains voltage<strong>SVERKER</strong> <strong>750</strong> 230 V Mains voltageComplete with:<strong>Test</strong> lead setTransport case<strong>SVERKER</strong> <strong>760</strong> 115 V Mains voltage<strong>SVERKER</strong> <strong>760</strong> 230 V Mains voltageComplete with:<strong>Test</strong> lead setTransport caseCat. No.CD-11190CD-12390GA-00030GD-00182CD-21190CD-22390GA-00030GD-00182Item (Qty)Optional accessoriesCat. No.<strong>SVERKER</strong> Win PC SoftwarePlease specify the <strong>SVERKER</strong> serial number when ordering.<strong>SVERKER</strong> Win contains software,a copy-protection key and a cableused to connect the PC to <strong>SVERKER</strong>.Note that the software key can beinstalled on a single <strong>SVERKER</strong>.The software itself, however, can beinstalled on an unlimited number of PCs. CD-8102X<strong>SVERKER</strong> Win UpgradeCD-8101XPROM* update, done by MeggerCD-89010PROM* update, done by customerCD-89011* <strong>SVERKER</strong> Win requires PROM-version R04A or higherCSU20AComplete with cables and transport case115 V Mains voltage BF-41190CSU20AComplete with cables and transport case230 V Mains voltage BF-42390Phase selector switch, PSS<strong>750</strong>CD-90020UKArchcliffe Road, DoverCT17 9EN EnglandT +44 (0) 1 304 502101F +44 (0) 1 304 207342UKsales@megger.comUNITED STATES4271 Bronze WayDallas, TX 75237-1019 USAT 1 800 723 2861 (USA only)T +1 214 333 3201F +1 214 331 7399USsales@megger.comOTHER TECHNICAL SALES OFFICESTäby SWEDEN, Norristown USA,Sydney AUSTRALIA, Toronto CANADA,Trappes FRANCE, Kingdom of BAHRAIN,Mumbai INDIA, Johannesburg SOUTHAFRICA, and Chonburi THAILANDRegistered to ISO 9001:2000 andISO 14001:2004Cert. no. GBG0005937<strong>SVERKER</strong>_<strong>750</strong>_DS_en_V01www.megger.comMegger is a registered trademark

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!