From IPC – Now Part of Grace Construction ProductsFS <strong>1900</strong>SERIESSEALANTINTUMESCENT,ELASTOMERICFIRESTOPFlameSafe ® FS <strong>1900</strong> Series Sealant —Dynamic Movement Approved (Patent Pending)General DescriptionFlameSafe ® FS <strong>1900</strong> is a high-performance, <strong>elastomeric</strong>and <strong>intumescent</strong> <strong>sealant</strong>. It is a highsolids,water-based compound engineered to provideexceptional adhesive and <strong>elastomeric</strong> properties forthe demanding <strong>firestop</strong> requirements of pipe, cable,sprinkler penetrations and construction joints in environmentssubjected to frequent expansion and contraction.FS <strong>1900</strong> is highly <strong>intumescent</strong>. It expands up to 7 times(700%) its original volume to fill the void created by themelting and burning of PVC, CPVC, cc-PVC, ABS,cc-ABS, PEX, insulated pipe, and plastic-coated cables.FS <strong>1900</strong> does not contain solvents. As a result, it is nottoxic and cannot damage plastic pipes or cable jackets.Physical PropertiesColorOdorVehicleWeightRed*Faint LatexWater-based10.0 lbs/gal(1.2 kg/L)pH 10-11Volume Expansion 700%Installation Temp. (40° to 90° F)/(4°to 32° C)Storage Temp. (40° to 90° F)/(4°to 32° C)ASTM C719Flame Spread 0(ASTM E84)Smoke Developed 5(ASTM E84)* Prior to 5/15/97, FS<strong>1900</strong> was blue/gray.PassedFEATURES• UL Approved• Factory Mutual certified• Warnock Hersey listed• Up to 3 hour fire-rating• UL 1 and 2 hour fire-rated systemsfor CPVC• Tested to UL 1479 (ASTM E814),UL 2079 (ASTM E1399), ASTMC719, ASTM E84 (UL 723)• Used in bus and HVAC ducts,through-penetrations with mixedpenetrants, metallic or non-metallicpipes, and construction joints• Wood joist and chase wallfloor-ceiling assemblies• Excellent adhesion• Water-based, high-solids• No solvents• No silicones, no outgassing• Caulkable or trowelable• Two-stage <strong>intumescent</strong> system• Highly <strong>intumescent</strong> – 700%• Elastomeric• Sandable/paintable• Easily repaired or repenetrated


Figure 1CPVC & PVC SystemUL System WL 2038 – 1 & 2 HourFigure 2Metallic Pipe PenetrationUL System CAJ1235 – 3 HourFigure 3Wood Joist and Chase Wall Floor-CeilingUL System FC2082 – 1 HourGYPSUM WALLBOARD5/8" TWO LAYERSFlameSafe ® FS <strong>1900</strong>1 1/4" DEEPFlameSafe ® FS<strong>1900</strong>. FOR 3 HR. FIRE-RATING,APPLY A MIN. 1 IN. THICK FLUSH WITH THEFLOOR. APPLY A 3/8 IN. CROWN AT THE POINTOF CONTACT.MIN. 4-1/2 IN. CONCRETE FLOOR.MIN. 1 IN. THICK (BACKER ROD)POLYURETHANE BACKING.MAX. 2" DIA. PVC, CPVC,OR NON-METALLIC CONDUITNOMINAL 6 IN. DIAMETER OR SMALLER COP-PER PIPE. MAX. 24 IN. DIAM. OR SMALLERSTEEL OR CAST IRON PIPE. MAX. 4 IN. DIAM. ORSMALLER EMT CONDUIT OR 6 IN. DIAM. ORSMALLER STEEL CONDUIT.FlameSafe ® FS <strong>1900</strong>. At floor surfaceapply a 3/4" depth with a 3/8" crown.Nom. 2" x 6" or parallel 2" x 4"lumber plates.Min. 3/4" lumber or plywood subfloor.Max. 4-3/4" opening.Nom. 2" x 10" lumber joists.One layer of gypsum wallboardceiling capable of providing a 1 hr.F rating.Double top plate consisting of two2" x 6" or two sets of2" x 6" or double 2" x 4" lumberstuds.Max. 4" diameter or smaller PVC(solid or cellular core) and CPVCpiping as an open (vented) or closedsystem.Nom. 1/8" annular space.Apply a 3/4" depth of FS <strong>1900</strong> at thebottom plate. Apply a 3/8" crown.Applicable StandardsFlameSafe ® FS <strong>1900</strong> is classified by UnderwritersLaboratories Inc., and Underwriters Laboratoriesof Canada for 1, 2 and 3 hour rated systems,in accordance with ASTM E814 (UL1479/CAN4-S115M), Fire Tests of Through-Penetration Firestops. FS <strong>1900</strong> is Factory Mutualapproved and listed by Warnock Hersey. It hasbeen tested to and passed ASTM C719, Adhesion/Cohesionof Elastomeric Joint Sealant forCyclic Movement (UL 2079, Standard for FireTests of Joint Systems). In addition, the FS <strong>1900</strong>is accepted by the city of New York (MEA), thecity of Los Angeles, and ICBO.Systems are available for: metallic and nonmetallicpipe, cable, conduit, cable tray and ductpenetrations through typical wall and floor construction;expansion joints; construction jointssuch as wall to wall, floor to floor, wall to floorand curtain wall; concrete, masonry, fluted deckand gypsum substrates; wood joist floor-ceilingand chase wall assemblies.ApplicationsFlameSafe ® FS <strong>1900</strong> is used to seal openings infire-rated structures where burning plastic pipe,insulated pipe, or coated cables may compromisethe rated system. It also can be used in busand HVAC ducts and through-penetrations withmetallic pipes and mixed penetrants. It is usedin conjunction with mineral wool boards in safingapplications to prevent smoke, fire and toxicgases from spreading through perimeter jointsand floor slabs, openings between fluted roofand floor decks, tops of fire-rated walls, woodjoist and chase wall floor-ceiling assemblies andother construction/seismic joints. See Figures1–4 for examples of typical details.FS <strong>1900</strong> is particularly suited for use in applicationswhere system vibration and buildingmovement are concerns.InstallationAll contact surfaces must be free of loose dirt,scale, oil or other foreign materials. Installationprocedures and material used may vary accordingto the size of opening being protected andthe type of penetrant. Material may be installedusing a standard or powered caulk gun, or troweledinto place using a mason’s trowel or puttyknife. FS <strong>1900</strong> is a water-based <strong>sealant</strong> thatdries through evaporation. Time required fordrying will vary according to environmentalconditions. When dry, FS <strong>1900</strong> remains<strong>elastomeric</strong>, indefinitely.


MaintenanceApplications using FS <strong>1900</strong> are maintenancefree, however, installations should be inspectedperiodically for accidental damage, and repairedusing FS <strong>1900</strong> as per the original approveddesign.Technical SupportGrace Construction Products provides Toll-FreeTechnical Support for all its products includingFlameSafe ® FS <strong>1900</strong>. Please call 1-800-898-7976 for assistance in product selection and fordetailed specifications and approvals. We provideengineering analysis for unique <strong>firestop</strong>pingapplications, including system designdrawings suitable for submittals.Material Safety Data Sheets are also available.You can also reach us at our Web site:http://www.flamesafe.com.FS <strong>1900</strong> can be used in joints between roof/floor decks (above) anddrywall or masonry walls, or, power caulked into construction jointapplications (below).WarrantyAll statements, technical information, and recommendationscontained herein are based ontests we believe to be reliable. However, sincethe conditions of use and applications arebeyond our control, Grace ConstructionProducts shall not be liable for any damage,direct or consequential, resulting from the use ofthis material or design. Grace ConstructionProduct’s only warranty shall be to replace anyof its products found to be defective.AvailabilityFlameSafe ® FS <strong>1900</strong> is available throughauthorized Grace Construction Products distributorsin the following quantities:Description Cat. No. Volume Std. PackCaulk Tube FS <strong>1900</strong> 19.0 cu. in. 1210.3 oz. (305 ml) (312 cu. cm.)Caulk Tube* FS 1929 57 cu. in. 631 oz. (.92L) (934 cu. cm.)Poly Pail FS 1901 231.0 cu. in. 41 gal. (3.8L) (3,788 cu. cm.)Poly Pail FS 1905 1,155 cu. in. 15 gal. (19.0L) (18,942 cu. cm.)* For use with powered caulk gun only. Call Grace ConstructionProducts for tool recommendation.Figure 4Roof/Wall (Fluted Steel Deck) AssemblyWHI System PSV 1095 – 2 HourWHI System PSV 1097 – 1 HourMINERAL WOOL INSULATIONFlameSafe ® FS <strong>1900</strong>Sealant: 5/8" DEEPGYPSUM WALLBOARD,1 or 2 HR. RATEDTWO 5/8" THICK LAYERS