<strong>Air</strong> <strong>to</strong> WaterFUTURE SOLUTION OF DOMESTIC HEATING


Efficient and comfortable heating solution<strong>Air</strong> <strong>to</strong> Water Heat PumpWATERSTAGE is a safe, comfortable, andefficient water heating system by adopting heatpump technology that utilizes <strong>the</strong> heat in <strong>the</strong> air.This system provides support for space heating and water heating.This WATERSTAGE uses very little electric energy <strong>to</strong> efficiently absorb heat from <strong>the</strong>atmosphere by adopting an inverter heat pump. A small environmental load heat sourcesystem can be economically realized by using this heat energy <strong>to</strong> produce hot water forradia<strong>to</strong>r, floor heating or domestic hot water.Flexible and comfortable heating solutionfor new building and refurbishment houseRadia<strong>to</strong>rDomestic hot waterDomestic hotwater tankHot water supplyIndoor unitUnder floor heatingTake <strong>the</strong>rmal energyfrom atmosphereOutdoor unitHeat Pump is most efficiency systemAbsorbing <strong>the</strong> free energy from atmosphere.Heat pump system requires only 1kW ofelectricity <strong>to</strong> generate 3 <strong>to</strong> 5 kW <strong>the</strong>rmal<strong>Air</strong> <strong>to</strong> Water configurationOutdoor airOutdoor unitIndoor unitWater heat exchangerimproves heating efficiencyUnder floor heatingsystemenergy.2~4 kWhAmbient airRefrigerantHeat PumpEvapora<strong>to</strong>rCompressorPumpHot water1 kWh electicity 3~5 kWh of heat


Indoor unitOutdoor unitWSYA050DAWSYA065DAWSYA080DAWSYA095DAWSYA128DAWSYA155DAAOYA18LALLAOYA24LALLAOYA30LBTLAOYA45LBTLAOY54LJBYLHigh EfficiencyHigh COP<strong>Air</strong> <strong>to</strong> water heat pumps work with much more efficiency andsave more energy than a traditional heating system.Highly efficient water heat exchangerDouble-pipe water heat exchanger withbuilt-in tank <strong>to</strong> reduce lossCOP (Coefficient of Performance)Fuel boiler0.85*The data refer <strong>to</strong> 6kW typeCondition : Outdoor Temp.7°C Heating Temp 35°C.Warmrefrigerant flowElectric heater1.00WATERSTAGE4.00Heated waterTechnology DC inverter with R410ALow ambient temperature performanceHighTemperatureConstantAchieves excellent heatingperformance even at an outdoorair temperature of -15ºC.TimeV-PAM invertertechnologySmoothcapacity controlHigh ReliabilityHigh Clean and Durability•Corrosion protected•No fouling through heat exchanger construction•Hot water is permanently available•Heating until -15°CStainless steel buffer tankOptimum co-axial heat exchangerAntifreeze is unnecessary


<strong>Air</strong> <strong>to</strong> WaterIntelligent Control SystemIntelligent regulationIntelligent operation system of WATERSTAGE system is provided <strong>to</strong> regulate <strong>the</strong>efficient and comfortable temperature according <strong>to</strong> your needs.•Au<strong>to</strong>matic temperature regulation in accordance with heatingcurve (depends on terminal and outdoor temperature).•2 Zone individual control (2 under floor heating zones or underfloor heating + radia<strong>to</strong>r zone, etc.)*OutdoorunitIndoor unit*Optional parts are required.2nd Circuit KitPumpValve2 Zone individual controlPumpRadia<strong>to</strong>rFloor heating~50°C~40°C•Water temperatureregulation can becombined with Room<strong>the</strong>rmostat.*•Additional electric heater control forbackup•Domestic hot water management withhot water tank*•Boiler docking is possible*•Cooling operation is possible*•Swimming pool heating*•Anti legionella functionRoom ThermostatUTW-C55XASmart operation•Simple design system•Hourly, Daily, Weekly programmingoperation•Holiday operation mode•Operation status display•Error display / Error his<strong>to</strong>ryDesign VersatilityInstallation exampleThe water heating system can be freely constructed for a wide range of applications from floor heating <strong>to</strong> hot water showers.Single heating systemUnder floor heatingIndoor unit2 system simultaneous heating (Individual control)Under floor heating +Indoor unitRadia<strong>to</strong>rOutdoorunitOutdoorunitValvePumpPumpRadia<strong>to</strong>rUnder floor heatingUnder floor heating3 types of heat distribution System for low outdoor air temperaturesUnder floor heating + Radia<strong>to</strong>r + Sanitary hot water(additional heating boiler connection)Under floor heating + Radia<strong>to</strong>r + Sanitary hot waterIndoor unitHot water showerIndoor unitTankBoilerTankValveValveHot water showerPumpValvePumpOutdoorunitValvePumpRadia<strong>to</strong>rOutdoorunitValvePumpRadia<strong>to</strong>rUnder floor heatingUnder floor heating


LineupCapacity range (kW)56 8 10 13 16Indoor unitModel nameWSYA050DAWSYA065DA WSYA080DA WSYA095DA WSYA128DA WSYA155DAOutdoor unitAOYA18LALLAOYA24LALLAOYA30LBTLAOYA45LBTLAOY54LJBYLOptional parts2nd Circuit KitBoiler Connection KitBalancing VesselUTW-KZSXAUTW-KBSXAUTW-TEVXADHW KitDHW Tank200LDHW Tank300LHigh Flow RateCirculating Pump KitUTW-KDWXAUTW-T20XAUTW-T30XAUTW-PHFXASwimming Pool KitHeat exchangerfor swiming poolCooling KitCooling Kit (High flow rate)UTW-KSPXAUTW-ESPXAUTW-KCLXAUTW-KCHXARemote ControlRoom ThermostatUTW-C75XAUTW-C55XA


<strong>Air</strong> <strong>to</strong> WaterDimensionsModels: WSYA050DA / WSYA065DA / WSYA080DAWSYA095DA / WSYA128DA / WSYA155DA(Unit : mm)4501034100088 235480Ø M 26x34ØM26x34SpecificationsCapacity (kW)5Heating capacity50006500W+7ºC/+35ºC floor heating Input power11601630COP4.304.00Heating capacity48005600W-7ºC/+35ºC floor heating Input power17502240COP2.752.50Heating capacity41505400W+7ºC/+45ºC radia<strong>to</strong>rsInput power11501610COP3.603.35Heating capacity40505100W-7ºC/+45ºC radia<strong>to</strong>rsInput power17202320COP2.352.20Electric heaterW 2 x 1500 2 x 1500Indoor unitModel name WSYA050DA WSYA065DADimensions H x W x DmmNet weight / filld weightkgHydaulic characteristicsBuffer tank capacityIExpansion Vessel capacityIWater flow rate (min./max.) 4°C ΔT°CI/h 540 / 1100 600 / 1400Electrical connectionsPower sourceCircuit breaker A 1616Outdoor unitModel nameAOYA18LALLPower sourceRated currentA 5.16 7.25Circuit breaker A16Dimensions H x W x D mm578 x 790 x 300Weight kg40Noise level *1 dBA39Operation range°CRefrigerantCooling characteristicsConnection pipe diameterLiquidmmGasØ12.7Refrigerant chargeg1250Min. / max. length m5 / 15Max. height difference m15Max. pipe length (chargeless) m15Additional charge amount per 1mg206 8 10 13 16800018804.25700025402.76620018803.30590026202.252 x 1500WSYA080DA860 / 17001034 x 450 x 48052.5 / 77.52581Ø 230V~, 50Hz1630AOYA24LALL AOYA30LBTL1Ø 230V~, 50Hz8.2716578 x 790 x 3154440-15~24R410A17005 / 15151520*1. Sound pressure level measured at distance of 5m from <strong>the</strong> device and at a height of 1.5m above ground in free field950023704.00810035202.30790023903.30790035902.202 x 3000WSYA095DA1000 / 205010.416830 x 900 x 330645522005 / 202020401280031204.101100037902.90970031303.10830046101.802 x 3000WSYA128DA1380 / 270030AOYA45LBTL13.7251290 x 900 x 330985533505 / 202020501550038804.001380053002.601330040903.251100053702.052 x 3000WSYA155DA1670 / 330030AOY54LJBYL17.1321290 x 900 x 33010555.5Ø6.35 Ø6.35Ø9.52 Ø9.52 Ø9.52Ø15.88 Ø15.88 Ø15.88 Ø15.8834005 / 202020401116, Suenaga, Takatsu-ku, Kawasaki 213-8502, JapanURL : http://www.fujitsu-general.com7NF000-0902EPrinted in Japan