12.07.2015 Views

Modular Housings - Kube Engineering

Modular Housings - Kube Engineering

Modular Housings - Kube Engineering

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Repeater Power SuppliesIsolation AmplifiersTransmittersIndicatorsProcess AnalyticsPortable MetersLaboratory MetersSensorsFittingsSpecifications (continued)Transmission behaviorl–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Gain error Current output < 0.1% meas. val.Voltage output < 0.2% meas. val.l–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Response time< 2 msl–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Communication 2)Bidirectional transmission of FSK signals according to the HART ® specification between(output 4 ... 20 mA)output and current loopPower supplyl––––––––––––––––––––––––––Power supplyl–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––24 V DC (±15 %), approx. 1 WThe power supply can be routed from one device to another via cross-connections.Isolationl–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Galvanic isolation3-port isolation between current loop, output, and power supplyl–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Test voltage2.5 kV AC current loop against output/power supply510 kV AC output against power supplyl–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Working voltageUp to 600 V AC/DC across current loop and output/power supply with overvoltage(basic insulation)category II and pollution degree 2, up to 100 V AC/DC across output and power supplywith category II and degree 2 according to EN 61010-1.For applications with high working voltages, you should ensure there is sufficient spacingor isolation from neighboring devices and protection against electric shocks.l–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Protection againstSafe Isolation according to EN 61140 by reinforced insulation in accordance withelectric shock EN 61010-1.Up to 300 V across current loop and output/power supply with overvoltage category IIand pollution degree 2.For applications with high working voltages, you should ensure there is sufficient spacingor isolation from neighboring devices and protection against electric shocks.Standards and approvalsl–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––EMC 3) Product standard: EN 61326Emitted interference: Class BImmunity to interference: Industryl–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Approval cURus, File No. E 220033, Standards: UL 508 and CAN/CSA 22.2 no. 14-952) HART ® attenuation

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!