12.07.2015 Views

Modular Housings - Kube Engineering

Modular Housings - Kube Engineering

Modular Housings - Kube Engineering

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Isolation Amplifiersfor Standard SignalsIsolation AmplifiersTransmittersIndicatorsProcess AnalyticsPortable MetersLaboratory MetersSensorsFittingsSpecifications (continued)Output data (continued)l––––––––––––––––––––––––––Offsetl––––––––––––––––––––––––––Residual rippleTransmission behaviorl––––––––––––––––––––––––––Gain errorl––––––––––––––––––––––––––Cut-off frequencyl––––––––––––––––––––––––––Temperature coefficient 2)l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––20 µA or 10 mVl–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––< 10 mVrmsl–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––< 0.08 % meas.val. (DC)l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––> 10 kHz, –3 dB, P 15000 F1/H1 switchable to < 10 Hz, –3 dBl–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––0.005 %/K full scale (reference temperature 23 °C)Power supplyl–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Power supply 20 ... 253 V AC/DC AC 48 ... 62 Hz, approx. 2 VADC approx. 0.9 WIsolationl–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Galvanic isolation3-port isolation between input, output and power supplyl–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Test voltage4 kV AC input against output against power supplyl–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Working voltage1000 V AC/DC with overvoltage category II and pollution degree 2 according to(basic insulation) EN 61010-1.For applications with high working voltages, you should ensure there is sufficient spacingor isolation from neighboring devices and protection against electric shocks.l–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Protection againstSafe Isolation according to EN 61140 by reinforced insulation in accordance withelectric shock EN 61010-1.Working voltages up to 300 V AC/DC across input and output and power supplywith overvoltage category II and pollution degree 2.For applications with high working voltages, you should ensure there is sufficient spacingor isolation from neighboring devices and protection against electric shocks.Standards and approvalsl–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Surge withstand 5 kV, 1.2/50 µs, according to IEC 255-4l–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––EMC 3) European EMC regulations; EN 61326l–––––––––––––––––––––––––– l–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Approvals CUL: File No. E 216767, Standards UL 3101-1, CSA-C22.2-95, No. 10101-1GL: No. 14593-99 HHKTA 3503/35073) Slight deviations are possible while there is interference2) Average TC in specified operating temperature range –10 ºC ... +70 ºC49

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!