<strong>GigaLine</strong><strong>®</strong> trunk, breakout cable, preassembled on both sides<br />
Cable type<br />
KL-I-V(<strong>ZN</strong>)<strong>HH</strong><br />
Construction:<br />
• Up to 12 breakout elements under one sheath<br />
• Strain relief of aramid yarns<br />
• Sheath: halogen free compound;<br />
Colour: orange for multimode, yellow for singlemode<br />
• Patch element ∅ 2.1mm; minimum length 55cm<br />
• Dust protected<br />
Fibre quality:<br />
2.5B600/0.7F1200 GBE750/2000<br />
Inkjet printing:<br />
<strong>LEONI</strong> <strong>GigaLine</strong> I-V(<strong>ZN</strong>)<strong>HH</strong> n $fiber type$ $core type$<br />
$2x ac symbol$ $charge no$ $reel no$ $meter sign$<br />
Application:<br />
Suitable for direct connection and for splicing.<br />
Particularly suitable for horizontal cabling for installation in<br />
conduits and ducts.<br />
Other characteristics:<br />
PM/HWt/12.10 Subject to misprints, errors and technical modifications<br />
<strong>LEONI</strong> Kerpen GmbH·Zweifaller Str. 275-287 ·D-52224 Stolberg ·Telefon +49/2402/17-1 ·Telefax +49/2402/75154 ·http://www.leoni-infrastructure-datacom.com ·E-Mail infrastructure-<br />
datacom@leoni.com<br />
Fibre type<br />
Insertion<br />
loss<br />
Return loss<br />
Temperature range:<br />
Transport and storage -25°C to +70°C<br />
During installation -5°C to +50°C<br />
After installation -10°C to +50°C<br />
Bending radius:<br />
After installation 10 x outer diameter<br />
During installation 15 x outer diameter<br />
Fire performance:<br />
Flameretardancy IEC 60332-1<br />
IEC 60332-3-24<br />
Smoke density IEC 61034<br />
Halogen free acc. IEC 60754-2<br />
Connector<br />
both sides<br />
<strong>LEONI</strong> P/N<br />
G50/125 OM2e 25 dB SC-simplex 9Vxxx127<br />
xxx=length in meter
<strong>GigaLine</strong> <strong>®</strong> trunk, breakout cable, preassembled on both sides<br />
Singelmode OS2<br />
Fibers: SC ST E2000 E2000HRL FC-PC LC<br />
2 9Vxxx11C 9Vxxx11H 9Vxxx11M 9Vxxx11R 9Vxxx11W 9Vxxx121<br />
4 9Vxxx11D 9Vxxx11I 9Vxxx11N 9Vxxx11S 9Vxxx11X 9Vxxx122<br />
6 9Vxxx11E 9Vxxx11J 9Vxxx11O 9Vxxx11T 9Vxxx11Y 9Vxxx123<br />
8 9Vxxx11F 9Vxxx11K 9Vxxx11P 9Vxxx11U 9Vxxx11Z 9Vxxx124<br />
12 9Vxxx11G 9Vxxx11L 9Vxxx11Q 9Vxxx11V 9Vxxx120 9Vxxx125<br />
Multimode OM2e<br />
Fibers: SC ST E2000 FC-PC LC<br />
2 9Vxxx126 9Vxxx12B 9Vxxx12G 9Vxxx12L 9Vxxx12Q<br />
4 9Vxxx127 9Vxxx12C 9Vxxx12H 9Vxxx12M 9Vxxx12R<br />
6 9Vxxx128 9Vxxx12D 9Vxxx12I 9Vxxx12N 9Vxxx12S<br />
8 9Vxxx129 9Vxxx12E 9Vxxx12J 9Vxxx12O 9Vxxx12T<br />
12 9Vxxx12A 9Vxxx12F 9Vxxx12K 9Vxxx12P 9Vxxx12U<br />
Multimode OM3<br />
Fibers: SC E2000 LC<br />
2 9Vxxx 9Vxxx 9Vxxx<br />
4 9Vxxx 9Vxxx 9Vxxx<br />
6 9Vxxx 9Vxxx 9Vxxx<br />
8 9Vxxx 9Vxxx 9Vxxx<br />
12 9Vxxx 9Vxxx 9Vxxx<br />
Multimode OM4<br />
Fibers: SC E2000 LC<br />
2 9Vxxx 9Vxxx 9Vxxx<br />
4 9Vxxx 9Vxxx 9Vxxx<br />
6 9Vxxx 9Vxxx 9Vxxx<br />
8 9Vxxx 9Vxxx 9Vxxx<br />
12 9Vxxx 9Vxxx 9Vxxx<br />
Multimode OM1e<br />
Fibers SC ST E2000 FC-PC LC<br />
2 9Vxxx14T 9Vxxx14Z 9Vxxx155 9Vxxx15B 9Vxxx15H<br />
4 9Vxxx14U 9Vxxx150 9Vxxx156 9Vxxx15C 9Vxxx15I<br />
6 9Vxxx14V 9Vxxx151 9Vxxx157 9Vxxx15D 9Vxxx15J<br />
8 9Vxxx14W 9Vxxx152 9Vxxx158 9Vxxx15E 9Vxxx15K<br />
12 9Vxxx14Y 9Vxxx154 9Vxxx15A 9Vxxx15G 9Vxxx15M<br />
xxx=length in meters, measured from connector point A to connector point B<br />
if required other connectors are available<br />
Description for <strong>Trunk</strong>s:<br />
<strong>GigaLine</strong> <strong>®</strong> <strong>Trunk</strong> $fibre type$ $connector type 1$ $connector type 2$ $cable type$ $protection class$ $length$ m<br />
Example: Gigaline <strong>®</strong> <strong>Trunk</strong> OM4 LC-LC I-V(<strong>ZN</strong>)<strong>HH</strong> IP67, 30m<br />
PM/HW/02.2011 Subject to misprints, errors and technical modifications<br />
<strong>LEONI</strong> Kerpen GmbH·Zweifaller Str. 275-287 ·D-52224 Stolberg ·Telefon +49/2402/17-1 ·Telefax +49/2402/75154 ·http://www.leoni-kerpen.com ·E-Mail Info@leoni-kerpen.com