Dr. Matthias Dräger BayCovin™ Instruments - Agilent Technologies
Dr. Matthias Dräger BayCovin™ Instruments - Agilent Technologies
Dr. Matthias Dräger BayCovin™ Instruments - Agilent Technologies
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong>
Bridging the Gap between Logistics<br />
and Laboratory Systems<br />
BayCovin <strong>Instruments</strong><br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger • Bayer Business Services GmbH
BayCovin <strong>Instruments</strong><br />
Agenda<br />
� About us<br />
� Product Structure and Key Features<br />
� Workflow and Data Structure<br />
� System Architecture and Device Integration<br />
� Integration of Chromatography Data Systems (CDS)<br />
� Examples for small / medium / large Installations<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong>
Bayer AG -<br />
Strategic Management Landscape<br />
Bayer<br />
HealthCare<br />
Holding<br />
Working Areas<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
Bayer AG<br />
Bayer<br />
CropScience<br />
Board<br />
Bayer<br />
Polymers<br />
Corporate Center<br />
Bayer<br />
Chemicals<br />
Service Areas<br />
Bayer<br />
Business Services<br />
Bayer<br />
Technology Services<br />
Bayer<br />
Industry Services<br />
Independent Bayer Business Services in a broad corporate enterprise.
Bayer Business Services<br />
Focus Areas<br />
� Service offerings are organized in the following subject<br />
categories:<br />
� Business Enabling &<br />
Consulting<br />
� Finance & Accounting<br />
� Human Resources Services<br />
� IT Operations<br />
� Law & Patents<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
� Logistics Solutions<br />
� Pensions<br />
� Procurement<br />
� Science & Technology<br />
� Training &<br />
Development
A Competent and Reliable Partner for<br />
Business Process Outsourcing<br />
BBS supports their customers<br />
along the entire value chain with:<br />
Business Services,<br />
Administrative Services,<br />
IT-Services.<br />
From consulting to delivery of complete business processes.<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong>
BayCovin <strong>Instruments</strong><br />
History and Implementation Roadmap<br />
First tests for<br />
laboratory<br />
automation<br />
Pilot project and<br />
development for<br />
Bayer HealthCare<br />
1995 1996 1998 2000 2001 2003 2004<br />
Instrument<br />
connection to<br />
commercial LIMS<br />
Instrument<br />
connection<br />
to SAP R/3<br />
Laboratory<br />
automation for<br />
chemical industry<br />
Connection to<br />
<strong>Agilent</strong> Cerity and<br />
Chemstation<br />
Go-live quality control<br />
for pharmaceutical<br />
active ingredients
BayCovin <strong>Instruments</strong><br />
Agenda<br />
� About us<br />
� Product Structure and Key Features<br />
� Workflow and Data Structure<br />
� System Architecture and Device Integration<br />
� Integration of Chromatography Data Systems (CDS)<br />
� Examples for small / medium / large Installations<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong>
BayCovin <strong>Instruments</strong><br />
Information and Product Structure<br />
�mySAP <br />
�mySAP <br />
PLM QM<br />
�Instrument<br />
Server<br />
�Laboratory<br />
Instrument<br />
Client<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
Enterprise Level<br />
Laboratory Level<br />
Device Control Level<br />
Device Level<br />
Level of Detail<br />
Master Data / Results<br />
BayCovin<br />
<strong>Instruments</strong>
BayCovin <strong>Instruments</strong><br />
Key Features<br />
� Efficient<br />
– Flexible integration of laboratory devices with mySAP PLM QM<br />
– Fully automated result entry, data acquisition,<br />
support of formula calculations<br />
– Configurable authentication and workflow for result validation<br />
– Workflow control and result entry using a barcode reader<br />
� Lean<br />
– Add-on for quality management in mySAP PLM<br />
– Small implementation projects and reduction of support costs<br />
� Validatation Capable<br />
– Compliant with current ISO, GxP regulations & FDA 21 CFR Part 11<br />
– Authentication and electronic signatures using biometrics<br />
– Certified interface with mySAP PLM QM<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong>
BayCovin <strong>Instruments</strong> - A Lower Cost LIMS Alternative<br />
Benefits<br />
� Cost reduction / resource optimization<br />
– Single point of master data maintainance<br />
– Non-redundant data storage<br />
– No data synchronization<br />
– Less complexity - lean system architecture<br />
� Increased throughput speed and time saving<br />
– Cross-system workflow<br />
– Reduction of work steps (depending on LIMS)<br />
– Electronic documentation<br />
� Integration with the BayCovin product family<br />
– BayCovin Specifications – BayCovin Control<br />
– BayCovin Complaint – BayCovin Process<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong>
BayCovin <strong>Instruments</strong><br />
Agenda<br />
� About us<br />
� Product Structure and Key Features<br />
� Workflow and Data Structure<br />
� System Architecture and Device Integration<br />
� Integration of Chromatography Data Systems (CDS)<br />
� Examples for small / medium / large Installations<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong>
BayCovin <strong>Instruments</strong><br />
Workflow and Data Structure<br />
mySAP <br />
PLM QM<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
BayCovin<br />
<strong>Instruments</strong> Server<br />
BayCovin<br />
<strong>Instruments</strong> Client<br />
Inspection lot creation<br />
in mySAP PLM QM<br />
• Goods receipt from<br />
production / for<br />
external procurement<br />
• Audit inspections<br />
• Manual inspection<br />
lots
BayCovin <strong>Instruments</strong><br />
Workflow and Data Structure<br />
mySAP <br />
PLM QM<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
Insp. lots<br />
Catalogs<br />
BayCovin<br />
<strong>Instruments</strong> Server<br />
BayCovin<br />
<strong>Instruments</strong> Client<br />
Selection and<br />
Download to<br />
BayCovin<br />
<strong>Instruments</strong> Server<br />
• For relevant work<br />
centers and inspection<br />
methods only<br />
• Asynchronously -<br />
no permanent on-line<br />
connection to SAP<br />
required<br />
– periodically<br />
– event-driven<br />
– manually<br />
• Architecture allows<br />
multiple servers<br />
connected to multiple<br />
SAP systems (n:m)
BayCovin <strong>Instruments</strong><br />
Workflow and Data Structure<br />
mySAP <br />
PLM QM<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
Insp. lots<br />
Catalogs<br />
BayCovin<br />
<strong>Instruments</strong> Server<br />
BayCovin<br />
<strong>Instruments</strong> Client<br />
Add characteristics to<br />
BayCovin<br />
<strong>Instruments</strong> inspection<br />
method<br />
• BayCovin<br />
<strong>Instruments</strong><br />
characteristics are<br />
added to mySAP PLM QM<br />
characteristics<br />
• Defined by mySAP PLM QM inspection<br />
method<br />
• Catalog download<br />
for qualitative<br />
characteristics
BayCovin <strong>Instruments</strong><br />
Workflow and Data Structure<br />
mySAP <br />
PLM QM<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
Insp. lots<br />
Catalogs<br />
BayCovin<br />
<strong>Instruments</strong> Server<br />
Work list<br />
BayCovin<br />
<strong>Instruments</strong> Client<br />
Intermediate<br />
results<br />
Result entry and<br />
data acquisition<br />
• Work list selection by<br />
inspection lot, work<br />
center, method or free<br />
selection<br />
• insp. lot centered or<br />
insp. characteristic<br />
centered result entry<br />
• Automatic data<br />
acquisition or manual<br />
result entry<br />
• Data validation by user<br />
ID & password or<br />
biometrics<br />
• Audit trail and audit<br />
remark whenever data<br />
is changed
BayCovin <strong>Instruments</strong><br />
Workflow and Data Structure<br />
mySAP <br />
PLM QM<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
Insp. lots<br />
Catalogs<br />
BayCovin<br />
<strong>Instruments</strong> Server<br />
Calculation<br />
Work list<br />
BayCovin<br />
<strong>Instruments</strong> Client<br />
Intermediate<br />
results<br />
Formula calculation<br />
(event-driven)
BayCovin <strong>Instruments</strong><br />
Workflow and Data Structure<br />
mySAP <br />
PLM QM<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
Insp. lots<br />
Catalogs<br />
End results<br />
BayCovin<br />
<strong>Instruments</strong> Server<br />
Calculation<br />
Work list<br />
BayCovin<br />
<strong>Instruments</strong> Client<br />
Intermediate<br />
results<br />
Final result<br />
confirmation<br />
• Intermediate result<br />
validation (4-eye<br />
principle)<br />
• Validated final<br />
result is transmitted<br />
back to mySAP <br />
PLM QM<br />
• Result data origin<br />
is set to „Copied<br />
from subsystem<br />
using QM-IDI“
BayCovin <strong>Instruments</strong><br />
Workflow and Data Structure<br />
mySAP <br />
PLM QM<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
Insp. lots<br />
Catalogs<br />
7<br />
End results<br />
BayCovin<br />
<strong>Instruments</strong> Server<br />
Calculation<br />
Archiving<br />
Work list<br />
Archiv<br />
BayCovin<br />
<strong>Instruments</strong> Client<br />
Intermediate<br />
results<br />
Reports<br />
Archiving and<br />
Reporting
BayCovin <strong>Instruments</strong><br />
Agenda<br />
� About us<br />
� Product Structure and Key Features<br />
� Workflow and Data Structure<br />
� System Architecture and Device Integration<br />
� Integration of Chromatography Data Systems (CDS)<br />
� Examples for small / medium / large Installations<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong>
BayCovin <strong>Instruments</strong><br />
Laboratory Instrumentation<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
BayCovin<br />
<strong>Instruments</strong> Client<br />
• RS-232<br />
• Parallel<br />
• Manual<br />
• LAN<br />
• CDS
BayCovin <strong>Instruments</strong><br />
Laboratory Instrumentation (Dev. stage 1)<br />
� Analytical Balances<br />
– Mettler AE 160/9<br />
– Mettler AE 240<br />
– Mettler AT 250<br />
– Mettler AT 261 Delta Range<br />
– Mettler AX 205<br />
– Sartorius R 160 P<br />
� Precision Balances<br />
– Mettler PG 300<br />
– Mettler PG 5002 SDR<br />
– Mettler PR 503<br />
– Mettler PR 503 Delta Range<br />
– Mettler PR 1203<br />
– Sartorius U 6100 S<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
� <strong>Dr</strong>y Balances<br />
– Sartorius MA 40<br />
� pH-Meter<br />
– Knick pH-Meter 764<br />
– Knick pH-Meter 765<br />
– Metrohm 691 pH-Meter<br />
� Autotitrators<br />
– Mettler DL 67<br />
– Mettler DL 70<br />
– Metrohm 633 (Karl-Fischer)<br />
– Mettler DL35 (Karl-Fischer)<br />
� Melting Point Determination<br />
– Büchi 545
BayCovin <strong>Instruments</strong><br />
Laboratory Instrumentation (Dev. stage 2)<br />
� Analytical Balances<br />
– Mettler AE200<br />
– Mettler AT200<br />
– Mettler AT201<br />
– Mettler AT260<br />
– Mettler AT400<br />
– Mettler PC4400<br />
– Mettler PE200<br />
– Mettler PM3000<br />
– Mettler PM4600<br />
– Mettler PM480DR<br />
– Mettler PM6000<br />
– Mettler PR5002<br />
– Sartorius 1402<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
� pH-Meter<br />
– Metrohm 691<br />
– Metrohm 713<br />
� Photometer<br />
– Jena Optic Specord 200PC<br />
– <strong>Agilent</strong> 8452A<br />
– Perkin Elmer Lambda 40<br />
– Perkin Elmer Lambda 2<br />
� Autotitrators<br />
– Metrom701 KF<br />
– Mettler DL70ES<br />
– Metrohm Titroprozessor<br />
� ...
BayCovin <strong>Instruments</strong><br />
Laboratory Instrumentation (Dev. stage 3)<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
� HPLC/GC (Q1/2004)<br />
– <strong>Agilent</strong> 1100<br />
– <strong>Agilent</strong> 1050<br />
– <strong>Agilent</strong> 5890<br />
– Cerity<br />
– ChemStation<br />
� IR/NIR<br />
– Bühler VIS1035 IR<br />
– Bruker IFS<br />
� Capillary electrophoresis<br />
– HP-3D CECE<br />
� ...
BayCovin <strong>Instruments</strong><br />
Extensive Experience in Device Integration<br />
� AccuPyc 1330 Micromeritics<br />
� Alliance Waters<br />
� Barcode printer 9200 PC Brother<br />
� BIEGE-Automat Zwick<br />
� Cerity NDS (for QA/QC) <strong>Agilent</strong><br />
� ChemStation GC/HPLC <strong>Agilent</strong><br />
� ChromCard ThermoFinnigan<br />
� CO2-Analyser Wösthoff GmbH<br />
� ComServer Wiesemann + Theis<br />
� Dataflash Datacolor<br />
� Dataflash Datacolor<br />
� Dosimat 402 Gilson ZWICK<br />
� EDOS Pipette Eppendorf<br />
� Color Analysis BYK Gardner<br />
� Solid Material Analysis Smart System 5 CEM<br />
� FTIR Spectrometer Nicolet<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
� Reflectivity Analysis BYK Gardner<br />
� Habscanner 3200 Welch Allyn<br />
� Rigidity Analysis Helmut Fischer<br />
� HDT-Automat COESFELD<br />
� Hot Disk C3 Analysentechnik<br />
� HPLC-Pump M302 Gilson<br />
� HPLC-Pump M305 Gilson<br />
� HPLC-Pump M306 Gilson<br />
� Interface M506 Gilson<br />
� Interface M606 Gilson<br />
� IR Waage LJ16 Mettler<br />
� KF-Titrino 701 Metrohm<br />
� Lab Balances PM460 Mettler<br />
� Lab Balances PM480 Mettler<br />
� LabX Mettler<br />
� Conductivity Analysis Knick
BayCovin <strong>Instruments</strong><br />
Extensive Experience in Device Integration<br />
� LICO 200 <strong>Dr</strong>LANGE<br />
� Liquidhandler LH215 Gilson<br />
� Liquidhandler LH222 Gilson<br />
� Multiple Way Valves Kronlab<br />
� Optical Measuring Device Heidenhain<br />
� MI-ROBO 89.92 Göttfert<br />
� Optical Measuring System Keyence<br />
� pH-Meter 761 Knick<br />
� pH-Meter 762 Knick<br />
� pH-Meter 765 Knick<br />
� ph-Meter Delta 345 Mettler<br />
� Photometer Knauer<br />
� Photometer Gilson<br />
� Automated Pipetter LISSY Zinsser<br />
� Refractometer GPR-11 THG <strong>Instruments</strong><br />
� Sammler Foxy ISCO<br />
� Layer Thickness Analysis BYK Gardner<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
� Layer Thickness Analysis Magna-Mike<br />
� Layer Thickness Analysis OnoSokki<br />
� Servomotor Mitsubishi<br />
� Nitrogen Analysis Abimed<br />
� TECAN 200 u. 300 TECAN<br />
� Thermostat Julabo<br />
� Thermostat Winkler<br />
� Thermostat H + P<br />
� Balances PM4800 Mettler<br />
� Titrator Schott<br />
� Titrator 756 Metrohm<br />
� Titrator CA06 Mitsubishi<br />
� Titrator DL 35 Mettler<br />
� Titrator DL 70 Mettler<br />
� Titrino 785 Metrohm<br />
� Titroprozessor Metrohm 672 Metrohm
BayCovin <strong>Instruments</strong><br />
Extensive Experience in Device Integration<br />
� Titroprozessor Metrohm 686 Metrohm<br />
� TOC 5050 A Shimatsu<br />
� TotalChrom GC PE Intruments<br />
� Transmission Analysis HUNTER<br />
� <strong>Dr</strong>y Balances MA30 Satorius<br />
� <strong>Dr</strong>y Balances MA30 Satorius<br />
� <strong>Dr</strong>y Balances YTC1L Satorius<br />
� VICAT-Automat COESFELD<br />
� VIDEO-CHECK-IP 400 Werth<br />
� VISCOROBO Göttfert<br />
� Viscosity Analysis Mooney Alpha Tec<br />
� Balances Satorius<br />
� Balances AG 245 Mettler<br />
� Balances AT 200 Mettler<br />
� Balances AT 260 Mettler<br />
� Balances AT 261 Mettler<br />
� Balances AT 261 Mettler<br />
� Balances AX 200 Mettler<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
� Balances PM Mettler<br />
� Balances PM 1200 Mettler<br />
� Balances PM 400 Mettler<br />
� Balances PR 2002 Mettler<br />
� Balances PR 2003 Mettler<br />
� Weighing- und Pipetting Device Zinsser<br />
� Weighing Device Bohdan<br />
� Decay Testing Erweka<br />
� Tension Analysis Zwick<br />
� Zwicki Pressure Analysis Zwick
BayCovin <strong>Instruments</strong><br />
Extensive Experience in Device Integration<br />
� Connection to<br />
– AJ Blome<br />
– APV<br />
– AutoChem-DB<br />
– Blomesystem<br />
– ChemLMS<br />
– COVIN <strong>Instruments</strong><br />
– El. Lab journal with Oracle-DB<br />
– KISS<br />
– ParaSynVE; AutoChem-DB<br />
– SAP R/3 QM<br />
– Thermo LabSystems<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
� Connection using<br />
– RS-232<br />
– analog<br />
– Datasystem<br />
– Keyboard Switch<br />
– Ethernet<br />
– GIA-RS484/RS-232 Adapter<br />
– GSIOC-Bus<br />
– INTEG-Box; RS-232-Interface<br />
– Mesuring Unit HDHx8 of K&S; RS-<br />
232
BayCovin <strong>Instruments</strong><br />
Agenda<br />
� About us<br />
� Product Structure and Key Features<br />
� Workflow and Data Structure<br />
� System Architecture and Device Integration<br />
� Integration of Chromatography Data Systems (CDS)<br />
� Examples for small / middle / large Installations<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong>
BayCovin <strong>Instruments</strong><br />
Cerity-Integration – Dataflow<br />
BayCovin<br />
<strong>Instruments</strong> Server<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
Work list<br />
BayCovin<br />
<strong>Instruments</strong> Client<br />
Intermediate<br />
results<br />
Analysis<br />
results<br />
Sequence<br />
Cerity<br />
Cerity as device<br />
• Work list selection by<br />
inspection lot, work<br />
center, method or free<br />
selection<br />
• Sequence organization<br />
as XML-File<br />
• Download to Cerity<br />
• Measurement in Cerity<br />
• Authorization<br />
• Four-eye principle<br />
• Upload of XML data<br />
• Assignment of analysis<br />
results to inspection<br />
lots
BayCovin <strong>Instruments</strong><br />
Cerity-Integration<br />
� Real-time addition of sample data<br />
– samples to be measured<br />
• net weight • average weight<br />
• density • material specific factors, e.g. dosage<br />
– Calibration samples<br />
• Calibration level • Net weight per component on<br />
calibration on the calibration level<br />
– No transfer as yet to Cerity (limitations of the interface)<br />
• Manual entry of net weight data in Cerity<br />
� Sequence transfer to Cerity as XML-File<br />
– File-Export to transfer log<br />
– No initiation as yet of sequence import into Cerity from outside<br />
(limitations of the interface)<br />
• Manual data import into Cerity<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong>
BayCovin <strong>Instruments</strong><br />
Cerity-Integration<br />
� Sequence Processing in Cerity<br />
– Sequence start<br />
– Data acquisition and evaluation<br />
– Results authorization (four-eyes-principle)<br />
• Values are ok � accepted<br />
• Values need rework � rework<br />
• Values are unacceptable� rejected<br />
� Import of the Results in BayCovin <strong>Instruments</strong><br />
– Start of „Sequence Result Data Export“ module by the customer<br />
– OOS-treatment of rejected values if necessary<br />
– Addition of samples added manually in Cerity if necessary<br />
– Reaction on cancelled sequences if necessary<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong>
BayCovin <strong>Instruments</strong><br />
Agenda<br />
� About us<br />
� Product Structure and Key Features<br />
� Workflow and Data Structure<br />
� System Architecture and Device Integration<br />
� Integration of Chromatography Data Systems (CDS)<br />
� Examples for small / middle / large Installations<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong>
BayCovin <strong>Instruments</strong><br />
Configuration Examples<br />
mySAP <br />
PLM QM<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
BayCovin<br />
<strong>Instruments</strong> Server<br />
BayCovin<br />
<strong>Instruments</strong> Client<br />
Small Installations<br />
• One mySAP PLM<br />
QM System<br />
• One BayCovin<br />
<strong>Instruments</strong> Server<br />
• One or several<br />
BayCovin<br />
<strong>Instruments</strong> Clients<br />
•Typically one<br />
customer per lab<br />
working space<br />
• e.g. for the<br />
integration of CDS<br />
into mySAP PLM<br />
QM<br />
•Mixed application<br />
of CDS and<br />
additional devices<br />
possible
BayCovin <strong>Instruments</strong><br />
Configuration Examples<br />
mySAP <br />
PLM QM<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
BayCovin<br />
<strong>Instruments</strong> Server<br />
BayCovin<br />
<strong>Instruments</strong> Client<br />
Medium to large<br />
installations<br />
• One mySAP PLM<br />
QM System<br />
• Several BayCovin<br />
<strong>Instruments</strong> Server<br />
• Typically one server<br />
per location<br />
• Distribution of tests<br />
to several locations<br />
• Several BayCovin<br />
<strong>Instruments</strong> Clients<br />
• Typically one client<br />
per lab working<br />
space<br />
• Each client belongs<br />
to only one server
BayCovin <strong>Instruments</strong><br />
Configuration Examples<br />
mySAP <br />
PLM QM<br />
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong><br />
BayCovin<br />
<strong>Instruments</strong> Server<br />
BayCovin<br />
<strong>Instruments</strong> Client<br />
Special case:<br />
Installation for service<br />
laboratory<br />
• Several mySAP PLM QM systems<br />
• One or more<br />
BayCovin<br />
<strong>Instruments</strong> Server<br />
• Typically one server<br />
per location<br />
• Data processing for<br />
several customers<br />
• Several BayCovin<br />
<strong>Instruments</strong> Clients<br />
• Typically one client<br />
per lab work place
<strong>Dr</strong>. <strong>Matthias</strong> <strong>Dr</strong>äger<br />
BayCovin <strong>Instruments</strong>