12.07.2015 Views

UNINTERRUPTIBLE POWER SUPPLY (UPS) Cat UPSB125

UNINTERRUPTIBLE POWER SUPPLY (UPS) Cat UPSB125

UNINTERRUPTIBLE POWER SUPPLY (UPS) Cat UPSB125

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>UNINTERRUPTIBLE</strong><strong>POWER</strong> <strong>SUPPLY</strong> (<strong>UPS</strong>)<strong>Cat</strong> ® <strong>UPS</strong>B12550 Hz60 kVA – 120 kVA(54 kW – 108 kW)<strong>Cat</strong>erpillar is leading the power generationmarketplace with Power Solutions engineered todeliver unmatched flexibility, expandability,reliability, and cost effectiveness.Image shown may not reflect actual product.FEATURESPRODUCT FEATURES Double conversion topology Integrated battery management system Batteries provide 5 minutes to 8 hours back-up Small footprint Up to 94% total system efficiency Power factor corrected input Transient protection High-speed voltage regulation Bottom cable entry Low input current distortion Simple installation Low maintenance Quiet operation Parallel up to six unitsRELIABLE <strong>POWER</strong> PROTECTION FORCRITICAL APPLICATIONS<strong>Cat</strong> ® double conversion battery <strong>UPS</strong> systems utilizeIGBT based technology to provide clean, stable powerto sensitive loads, ensuring critical power protection,optimum performance, and extended life of theprotected equipment.HIGH AVAILABILITYThe <strong>UPS</strong> has been designed for continuousoperation. Redundant components and cooling areavailable for increased reliability, and the <strong>UPS</strong> isfault tolerant with built in 100% rated static bypassswitch.FLEXIBLE AND UPGRADEABLEThe <strong>UPS</strong> is field expandable from 100 to 120 kVA.Further capacity can be added by parallelingmultiple <strong>UPS</strong>. The <strong>UPS</strong> has an intuitiveman/machine interface with a large high definitiondisplay and animated mimic display. With theaddition of optional communication cards, it can beeasily integrated into networking and monitoringsystems using common protocols such as Modbusor SNMP.WORLDWIDE PRODUCT SUPPORT<strong>Cat</strong> dealers provide extensive post sale supportincluding maintenance and repair agreements.Factory qualified technicians are trained to supportevery aspect of your <strong>Cat</strong> <strong>UPS</strong> system.SUPERIOR DESIGNSuperior system design and the use of robust digitalcomponents throughout the system yield a reliable andtrouble-free <strong>UPS</strong> system.LEHE0137-06


<strong>UNINTERRUPTIBLE</strong><strong>POWER</strong> <strong>SUPPLY</strong> (<strong>UPS</strong>)FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENTSTANDARD EQUIPMENT Network Management Card Front Panel DisplaySNMP protocol over 10/100MB EthernetLCD displayconnection, plus web interface and directLED mimic diagramemail/pager/SMS notification.Event logging with date-time stamping of over2000 events Single inputProvision converting unit to a single source input. Advanced Monitoring provides intelligent batterymanagement that automatically tests the batterysystem and provides life cycle monitoring of remainingbattery life expectancy. Alarm Relay CardDry contacts provide six (6) normally open contactsrated at 2.0A (250 VDC/30 VDC) for remotemonitoring of <strong>UPS</strong> operation. Default parameters are:<strong>UPS</strong> on line, load on bypass, <strong>UPS</strong> on battery, lowbattery warning, battery fault, and general alarm. Alsoincludes two (2) inputs to remotely turn the <strong>UPS</strong>inverter off and on.OPTIONAL EQUIPMENT RS232/RS485 CardJBus or Modbus protocol for use with third partyBuilding Management Systems (BMS) to monitordetailed three phase information. Second Alarm Relay CardDry contacts provide six (6) normally open contactsrated at 2.0A (250 VDC/30 VDC) for remotemonitoring of <strong>UPS</strong> operation. Default parameters are:<strong>UPS</strong> on line, load on bypass, <strong>UPS</strong> on battery, lowbattery warning, battery fault, and general alarm. Alsoincludes two (2) inputs to remotely turn the <strong>UPS</strong>inverter off and on. Battery Circuit BreakerProvides circuit breaker disconnect for batterypower source for use with customer suppliedbatteries TransformerProvides galvanic isolation for the output of the<strong>UPS</strong>. Top cable entryProvides auxiliary cabinet for top cable entry. Backfeed protectionProvides disconnect of the <strong>UPS</strong> from the inputsource on <strong>UPS</strong> discharge External syncProvides controls to synchronize the outputs oftwo <strong>UPS</strong> modules.LEHE0137-06 2


<strong>UNINTERRUPTIBLE</strong><strong>POWER</strong> <strong>SUPPLY</strong> (<strong>UPS</strong>)TECHNICAL DATARated Power kVA (kW) 60 (54) 80 (72) 100 (90) 120 (108)Normal AC InputInput Voltage (V)FrequencyPower FactorCurrent Distortion (THDI)380V - 400V - 415V 3 Wire+Ground*50 Hz ±5%


<strong>UNINTERRUPTIBLE</strong><strong>POWER</strong> <strong>SUPPLY</strong> (<strong>UPS</strong>)ONE LINE DRAWINGOptionalBackfeedProtectionELEVATION DRAWING850 mm(33.5 in)712 mm(28 in)1900 mm(74.8 in)Information contained in this publication may be considered confidential. Discretion is recommended when distributing.Materials and specifications are subject to change without notice.CAT, CATERPILLAR, their respective logos, “<strong>Cat</strong>erpillar Yellow,” the “Power Edge” trade dress as well as corporateand product identity used herein, are trademarks of <strong>Cat</strong>erpillar and may not be used without permission.www.<strong>Cat</strong>-ElectricPower.comLEHE0137-06 (06 6-11)4©2011 <strong>Cat</strong>erpillarAll rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!