12.07.2015 Views

CR4311 AC Current-to-Voltage Transducer 0-10Vdc Output

CR4311 AC Current-to-Voltage Transducer 0-10Vdc Output

CR4311 AC Current-to-Voltage Transducer 0-10Vdc Output

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>CR4311</strong> <strong>AC</strong> <strong>Current</strong>-<strong>to</strong>-<strong>Voltage</strong><strong>Transducer</strong>, 0-<strong>10Vdc</strong> outputThe CR431 series, <strong>Current</strong>-<strong>to</strong>-<strong>Voltage</strong> <strong>Transducer</strong>produces a 0-5 Vdc or 0-10 Vdc output signal that isdirectly proportional <strong>to</strong> the input <strong>AC</strong> current. The outputsignal is average-sensing, calibrated for RMS.This transducer is used with process control andindustrial instrumentation equipment. The DC outputsignal can be connected directly <strong>to</strong> a high impedanceanalog input of a computer or PLC without additionalsignal conditioning.The series will measure up <strong>to</strong> 200% of full scale on ashort time basis (1 minute or less) and 150% on acontinuous basis at its rated accuracy.To protect external circuits from damage caused byshort circuits or mo<strong>to</strong>r inrush currents.•••••FeaturesPermanently calibrated<strong>Output</strong> overload protectedFully isolated10 different rangesSelf-powered, requires no externalpower sourceSpecificationsAccuracy:Depends on the range and load resistance, seePart Numbers tableRipple:1% Max. peak ripple on outputCalibrated Signal Out:0-5 Vdc for CR43100-10 Vdc for <strong>CR4311</strong>Response Time:250 ms max., 10-90% FSMax. Signal Out:16 Vdc for CR431033 Vdc for <strong>CR4311</strong>Frequency:50/60 HzContinuous Thermal <strong>Current</strong> Rating Fac<strong>to</strong>r:2.50 @ 30°CShort Time Thermal <strong>Current</strong> Rating Fac<strong>to</strong>r:60 x Full Scale (For 1 Second)Insulation Class:600 V, BIL 10 kV Full WaveOperating Temperature Range:-30°C <strong>to</strong> +60°CS<strong>to</strong>rage Temperature Range:-55°C <strong>to</strong> +85 °CShipping Weight:1.5 pounds (.68 kg.)®E1542356Part NumbersCR431❑ - ❑ ❑ ❑ CURRENT TO VOLTAGE TRANSDUCER5101520305075100150200Range in <strong>AC</strong>Amps0-50-100-150-200-300-500-750-1000-1500-2000 0-5 Vdc Out1 0-10 Vdc OutAccuracy% FS *1.00.750.750.50.50.50.50.50.50.5* For <strong>to</strong>tal load resistance of:1.0 megohm or higher for CR4310150 K ohm or higher for <strong>CR4311</strong>WHERE-TO-BUY http://WWW.JDGASTORE.COM• <strong>Transducer</strong> Selection Guide: transducer.html• Application Sheet: pdf/ancr4310.pdf, pdf/ancr4310-2• Pricing: pricing/4310.html• External <strong>Current</strong> Transformers: cts.html


Call 972-699-9976Application Notes#10-32SCREWS2.69 (68.3)1.69 (42.9) .50 (12.7).25 (6.4)2.00 (50.8)2.36 (59.9).93 (23.6) DIA.<strong>Output</strong> Volts, DC35302520151050<strong>CR4311</strong>CR43100 50 100 150 200 250 300 350 400Percentage Full Scale (FS)CONTROL VOLTAGE OUT vs FULL-SCALE INPUT CURRENT2.75 (69.9)OUTLINE DRAWING.15 (3.8)0-5 Vdc for CR43100-10 Vdc for <strong>CR4311</strong>TOTAL LOAD RESISTANCE- +I INPUTINTERCONNECTRESISTANCEINSTRUMENTATIONRESISTANCEin (mm)TYPICAL CONNECTIONSTypical ApplicationsEXTERNAL CURRENT TRANSFORMERAn external current transformer may be used with the transducer byrouting the secondary leads through the window opening. Use theCR4310-5 or <strong>CR4311</strong>-5 current transducer with a 5 Amp secondaryinstrument grade current transformer. For additional details on currenttransformers, see page 25.3-PHASE SYSTEMSThree-phase systems may be moni<strong>to</strong>red by attaching three transducersin series. The <strong>to</strong>tal output voltage will be the sum of each individualtransducer. If each transducer is sized for the full-scale current, theoutput voltage will be 0-15 Vdc for the CR4310 Series (0-30 Vdc for the<strong>CR4311</strong> Series) at 0 <strong>to</strong> 100% full-scale. As an alternate, each transducermay be sized for three times the full-scale current, then the outputvoltage for the CR4310 will be 0-5 Vdc for 0 <strong>to</strong> 100% full-scale.Web: http://www.jimdgrayassoc.comEmail: jimgray@jimdgrayassoc.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!