CRILAT D117UNIT VALUE METHOD1. SUPPLY SPECIFICATIONSSolid content % 46±1 MVPF 01Brookfield viscosity (1) mPa.s 4 . 000±1 . 500 UNI EN ISO 2555pH 9.0±0.5 ISO 9762. TYPICAL VALUESMinimum film-<strong>for</strong>ming temperature °C +9 UNI 8490-14Particle size distribution μm 0.1÷0.2 MVANS 20Density at 23°C Kg/dm³ 1.06 MVPF 18Glass transition temperature °C 18±1 MVANS 01(1) RVT 20 rpm, 23°C, spindle 3FINISHING VEILED WITH DECORATIVE EFFECTRif. 03 040ECOMPONENTS w. % FUNCTION SUPPLIERSWater 65.40Ethylene glycol 0.60 Co-solvent VariousTexanol 1.00 Coalescent EastmanTego Foamex 1488 0.20 Defoamer EvonikActicide SPX 0.20 Biocide ThorTego Phobe 1650 7.00 Siloxane binder EvonikCrilat D117 22.00 Binder VinavilRheothec 2000 3.20 Thickener CoatexTego Foamex 1488 0.10 Defoamer EvonikAMP 90 0.30 Neutralizing agent AngusTotal 100.00Add the pigment pasta to get the desired colour.25